Orton
Filter
Showing all 9 results
| Brand | Orton |
|---|---|
| Origin | USA |
| Model | ANS800 Series |
| Max Operating Temperature | 800 °C or 1000 °C |
| Compliance | ASTM C336 |
| Temperature Control | PID-controlled, automated |
| Measurement Principle | LVDT-based fiber elongation monitoring under controlled cooling |
| Data Processing | Automated calculation of annealing point (AP) and strain point (SP) per ASTM C336 |
| Accuracy | ±1 °C (for glass fiber samples) |
| Software | Orton proprietary control & analysis suite with real-time plotting, statistical reporting, and audit-ready data logging |
| Brand | Orton |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | High-Temperature Viscometer |
| Model | BBV 1000 Series |
| Temperature Range | Up to 1000°C / 1200°C / 1600°C (configurable) |
| Control Method | PID-controlled programmable heating |
| Standards Compliance | ASTM C-598 (Annealing & Strain Point), ASTM C-1350M (Viscosity vs. Temperature) |
| Viscosity Range | 10⁹–10¹⁴ P (Poise) |
| Sample Span | Standard 50 mm (customizable) |
| Sample Cross-Section | 2.5–5.0 mm diameter rod |
| Measurement Principle | Beam bending deflection under constant load at elevated temperature |
| Detection | LVDT-based real-time deformation monitoring |
| Accuracy | ±1 °C for annealing/strain point determination on geometrically regular glass rods |
| Software | Orton proprietary control, acquisition, and analysis suite with automated reporting |
| Brand | Orton |
|---|---|
| Origin | USA |
| Model | DIL 2000 Series |
| Max Operating Temperature | 1000 °C (DIL 2010), 1200 °C (DIL 2020), 1600 °C (DIL 2030) |
| Low-Temp Capability | Down to –196 °C (with LN₂ cooling option, DIL 2010C) |
| Sample Dimensions | Up to 50 mm length × 20 mm diameter |
| Repeatability | ±0.004 PLC |
| Heating Rate | 1–30 °C/min |
| Temperature Resolution | 0.1 °C |
| Atmosphere Control | Optional inert/vacuum/oxidizing gas environments |
| Calibration Standards | Included (fused quartz, α-alumina, NIST-traceable reference materials) |
| Brand | Orton |
|---|---|
| Origin | USA |
| Model | DIL2010C |
| Temperature Range | –170 °C to 500 °C (or RT to 1000 °C with standard configuration) |
| Max Sample Size | 50 mm length × 10 mm diameter |
| Furnace Type | Split-tube (clamshell) quartz tube furnace |
| Sample Holder & Pushrod | Fused silica |
| Thermocouple | Type N (sample & control) |
| Heating Rate | 1–30 °C/min |
| LVDT Linear Range | ±2.54 mm |
| LVDT Resolution | 0.02 µm |
| Contact Force | Adjustable |
| Cryogenic Assembly | Stainless-steel cold stage with vertical transfer tube, Dewar reservoir mounted above furnace |
| Ambient Protection | Acrylic enclosure with dry inert gas purge |
| Compliance | ASTM E228, ISO 11359-1/-2, USP <631>, GLP-ready data logging |
| Brand | Orton |
|---|---|
| Origin | USA |
| Equipment Type | Horizontal Tube Furnace |
| Model | GTF-MD Series |
| Maximum Temperature | 1600 °C |
| Gradient Zone Length | 12 in (300 mm) or 16 in (405 mm) |
| Gradient Options | 10 °C/in or 20 °C/in |
| Corresponding ΔT Across Gradient Zone | 120 °C, 160 °C, 240 °C, or 320 °C |
| Compliance | ASTM C829A & C829B |
| Brand | Orton |
|---|---|
| Origin | USA |
| Model | PPV-1000/1200/1600 Series |
| Max Operating Temperature | 1600 °C |
| Viscosity Range | 10⁵–10⁹ Poise |
| Compliance | ASTM C1351M |
| Control Interface | RS-232 or USB |
| Load Application | Adjustable dead-weight system with triple-mass configuration |
| Displacement Sensing | LVDT (±2.5 mm full scale) |
| Sample Geometry | 44 mm diameter × ~1.5–3 mm thick glass disc |
| Heating System | Vertical tube furnace with sintered alumina or fused quartz support structure |
| Temperature Sensing | “S”-type thermocouple positioned adjacent to sample |
| Sample Fixturing | Dual 44 mm × 6 mm high-temperature alloy plates with 40 mm × 0.001″ platinum foil interlayers |
| Brand | Orton |
|---|---|
| Origin | USA |
| Model | RSV-1600, RSV-1700 |
| Viscosity Range | 10–3×10⁵ Poise |
| Max Operating Temperature | 1600 °C or 1700 °C |
| Compliance | ASTM C-965 (Method A), ASTM C-1276, ISO 7884-2 |
| Measurement Principle | Constant Angular Velocity (Couette Flow) |
| Sample Environment Options | Air, Vacuum, Inert Gas (N₂, Ar) |
| Crucible Capacity | 20–1000 g |
| Rotor & Crucible Materials | Pt/Rh alloy, Alumina, Graphite |
| Control System | PID Programmable Temperature Controller with Over-Temp Protection |
| Data Acquisition | Real-time torque, viscosity, temperature logging via VISCO software |
| Calibration Traceability | NIST SRM 717A certified reference glass |
| Brand | Orton |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SP-3A |
| Pricing | Upon Request |
| Max Temperature | 1000 °C |
| Temperature Accuracy | ±1 °C |
| Heating Rate | 25 °C/min |
| Probe Travel Range | 0–3 mm |
| Probe Resolution | 0.0025 mm |
| Brand | Orton |
|---|---|
| Origin | USA |
| Model | SP900D / SP1000D |
| Temperature Range | Up to 900°C or 1000°C |
| Heating Rate Control | Programmable PID, 5°C/min standard per ASTM C338 |
| Sample Geometry | Glass fiber, Ø0.65 mm × 235 mm |
| Softening Detection Method | Laser-based axial elongation tracking at 1 mm/min under self-weight |
| Compliance | ASTM C338 (Littleton softening point) |
| Data Acquisition | Real-time PC software with automated calculation, statistical reporting, and audit-ready output |
| Accuracy | ±1°C (repeatability on identical fibers) |
| Software Features | Mode selection, heating profile customization, GLP-compliant data logging, export to CSV/PDF |