PP
Filter
Showing all 6 results
| Brand | PP |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LactiCheck Mini |
| Detection Parameters | Fat, SNF, Protein, Lactose, Density, Water Admixture, pH (optional) |
| Automation Level | Fully Automatic |
| Analysis Time | 60 s per sample |
| Channel Configuration | 3 independent flow-through channels (raw cow milk, goat milk, sheep milk) |
| Repeatability | ≤ ±0.1% for fat & protein |
| Accuracy | ±0.1% (fat), ±0.15% (protein, SNF), ±0.0005 g/cm³ (density), ±0.5% (lactose), ±3% (water admixture) |
| Sample Volume | <15 mL |
| Operating Temperature Range (sample) | 15–30 °C |
| Ambient Operating Conditions | 7–40 °C, 30–80% RH |
| Power Supply | 110/220 VAC (±10%/−15%), 50/60 Hz or 12 VDC (optional) |
| Max Power Consumption | 30 W |
| Dimensions (H×W×D) | 11 × 24 × 26 cm |
| Net Weight | 3.0 kg |
| Brand | PP |
|---|---|
| Origin | USA |
| Model | RR01 |
| Automation | Fully Automatic |
| Analysis Time | 40 s |
| Fat Range | 0.5–9% |
| Fat Precision | ±0.06% |
| Fat Repeatability | <0.5% |
| SNF Range | 6–15% |
| SNF Precision | ±0.2% |
| Protein Range | 2–7% |
| Protein Precision | ±0.2% |
| Lactose Range | 3–7% |
| Lactose Precision | ±0.2% |
| Density Range | 1.0260–1.0330 g/cm³ |
| Density Precision | ±0.0005 g/cm³ |
| Water Adulteration Detection Range | 0–60% |
| Water Adulteration Precision | ±5% |
| Brand | PP |
|---|---|
| Origin | USA |
| Model | RR02 |
| Automation | Fully Automatic |
| Analysis Time | 40 s |
| Fat Range | 0.3–9% (±0.06% repeatability, ±0.2% accuracy) |
| Protein Range | 2–5% |
| SNF Range | 2–12% |
| Density Range | 1.0260–1.0330 g/cm³ (±0.0005 g/cm³) |
| Lactose Range | 3–7% (±0.1%) |
| Water Adulteration Detection | 2–60% (±2%) |
| Sample Volume | 20.0 mL |
| Dimensions (W×D×H) | 95 × 230 × 250 mm |
| Net Weight | 3.3 kg |
| Power Supply | AC 110/220 V ±10/−15%, DC 12–14.2 V |
| Max Power Consumption | 30 W |
| Data Interface | RS-232 (USB optional) |
| Brand | PP |
|---|---|
| Origin | USA |
| Model | LactiCyte HD |
| Detection Time | <60 s per run (with 4 chips) |
| Measurement Range | 0.1–10,000,000 SCC/mL |
| Sample Volume | 100 µL |
| Throughput | 4 samples per run |
| Cell Size Detection Range | 5–25 µm (optimized for mammary epithelial cells and leukocytes) |
| Accuracy | ±5% at 100,000 SCC/mL |
| Carryover | 0% |
| Operating Temperature | 10–35 °C |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Power Consumption | <50 W |
| Dimensions (W×D×H) | 38 × 26 × 30 cm |
| Net Weight | 10 kg |
| Compliance | ASTM D7952-21, ISO 13366-1:2015, IDF 148:2017, compliant with EU Regulation (EC) No 853/2004 for raw milk quality monitoring |
| Brand | PP |
|---|---|
| Origin | USA |
| Model | P2MA-50 |
| Automation | Fully Automatic |
| Analysis Speed | ≤2 min per sample |
| Measurement Range | 0.5–50 g sample mass |
| Repeatability | ±0.5% (with 3 g sample) |
| Accuracy | ±0.01 g weight resolution |
| Heating Source | Halogen Infrared Lamp |
| Temperature Range | 50–160 °C |
| Display | Real-time moisture %, initial/final mass, temperature |
| Pan Diameter | 100 mm |
| Dimensions | 28.5 × 16 × 15 cm |
| Net Weight | 4.2 kg |
| Brand | PP |
|---|---|
| Origin | USA |
| Model | QC-TECH |
| Automation | Fully Automatic |
| Analysis Time | < 2 min |
| Freezing Point Range | 0 to –1000 m°C or m°H |
| Repeatability | ±0.002 m°H (or m°C) |
| Linearity | < ±0.5% |
| Resolution | 0.001 m°H (or m°C) |
| Bath Temperature | –6.0°C ±0.5°C |
| Calibration | Two-point (422 & 621 m°H / 408 & 600 m°C) |
| Power Consumption | 120 W |
| Input Voltage | 95–250 VAC, 50/60 Hz |
| Fuse | 3 A |
| Operating Environment | 15–40°C, 30–80% RH |
| Sample Volume | 2.5 mL |
| Sample Throughput | Single-sample per run |