| Brand | Pro-Oceanus |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CO2-Pro CV |
| Pricing | Upon Request |
| Brand | Pro-Oceanus |
|---|---|
| Origin | Canada |
| Model | CO2-Pro™ |
| Measurement Principle | Membrane Equilibration with NDIR Detection |
| Standard Range | 0–600 µatm (extendable to 0–2000 µatm) |
| Accuracy | ±0.5% of reading |
| Resolution | 0.01 ppm (equivalent to 0.01 µatm) |
| Response Time (t₆₃) | 2.5 min (with integrated pump) |
| Operating Depth | Up to 50 m |
| Housing Material | Acetal (POM) |
| Temperature Range | 0–30 °C (standard), –2–20 °C (polar), 15–40 °C (tropical) |
| Power Input | 10–18 VDC |
| Power Consumption | 4 W (10 W during warm-up, including SBE 3K pump) |
| Data Output | RS-232 (ASCII), optional 0–5 V analog or 4–20 mA |
| Sampling Interval | Configurable down to 1 s |
| Internal Storage | 2 GB microSD card |
| Weight | 6.5 kg in air / 0.5 kg in water |
| Dimensions | 33 cm length × 19 cm diameter |
| Pressure/Temperature/Humidity Compensation | Automatic and embedded |
| Zero Calibration | Automatic Zero Point Calibration (AZPC) with onboard CO₂ scrubber |
| Biofouling Resistance | Fully membrane-isolated optical path |
| Compliance | Designed for GLP-aligned long-term deployments |
| Brand | Pro-Oceanus |
|---|---|
| Origin | Canada |
| Model | Mini CH4™ |
| Measurement Principle | Membrane Inlet Non-Dispersive Infrared (NDIR) Spectroscopy |
| CH₄ Range | 0–1% v/v, 0–10% v/v, or 0–100% v/v (user-selectable) |
| TDGP Range | 0–2 bar |
| Accuracy | ±3% FS (CH₄), ±1% FS (TDGP) |
| Stabilization Time (t₆₃) | 8 min (with pump head) |
| Resolution | 0.1% FS |
| Depth Rating | 600 m (acetal housing), 6000 m (titanium housing) |
| Operating Temperature | −2 °C to 35 °C |
| Power Input | 7–24 VDC (digital), 12–24 VDC (analog) |
| Power Consumption | 0.45 W (digital), 0.6–0.9 W (analog) |
| Data Output | RS-232 (ASCII CSV), 0–5 V analog, or 4–20 mA |
| Sampling Interval | Configurable down to 2 s |
| Internal Storage | 2 GB microSD card |
| Housing Material | Acetal or Grade 5 Titanium (Ti-6Al-4V) |
| Weight in Air | 0.53 kg |
| Weight in Water | 0.06 kg |
| Dimensions | 28 cm L × 5.3 cm Ø |
| Brand | Pro-Oceanus |
|---|---|
| Origin | Canada |
| Model | Mini CO2 |
| Measurement Principle | Membrane Equilibration with NDIR Detection |
| CO₂ Range | 0–2000 ppm (extendable to 0–100% vol) |
| TDGP Range | 0–2 bar |
| Accuracy | ±2% of full scale (pCO₂), ±1% FS (TDGP) |
| Response Time (t₆₃) | 3 min |
| Resolution | 0.1% of full scale |
| Operating Depth | 600 m (acetal housing), 6000 m (titanium housing) |
| Dimensions | 28 cm × 5.3 cm (L × Ø) |
| Weight in Air | 0.53 kg |
| Weight in Water | 0.06 kg |
| Temperature Range | –2 °C to +35 °C |
| Power Input | 7–24 VDC (digital), 12–24 VDC (analog) |
| Power Consumption | 0.45 W (digital), 0.6–0.9 W (analog) |
| Data Output | RS-232 (ASCII CSV), 0–5 V or 4–20 mA |
| Sampling Interval | Configurable down to 2 s |
| Internal Storage | 2 GB microSD |
| Pressure/Temperature/Humidity Compensation | Automatic |
| Compliance | Designed for ASTM D5176, ISO 14687, and GLP-aligned long-term environmental monitoring deployments |
| Brand | Pro-Oceanus |
|---|---|
| Origin | Canada |
| Model | Solu-Blu CH4 |
| Measurement Principle | Membrane Inlet Non-Dispersive Infrared (NDIR) |
| CH₄ Range | 0–30 mg/L (switchable to 0–3 mg/L and 0–300 µg/L) |
| TDGP Range | 0–2 bar |
| Accuracy | ±3% of full scale (pCH₄), ±0.1% FS (TDGP) |
| Response Time (t₆₃) | 10 min |
| Resolution | 0.1% of full scale |
| Operating Depth | 0–50 m |
| Temperature Range | 0–35 °C |
| Power Input | 7–24 VDC |
| Power Consumption | 90 mW (RS-232 + 0–5 V), 300–600 mW (RS-232 + 4–20 mA) |
| Output | RS-232 (ASCII), 0–5 V analog, or 4–20 mA analog |
| Sampling Interval | Configurable down to 2 s |
| Dimensions | 19.68 cm (L, sensor only), 25.68 cm (L with connector) |
| Weight | 0.47 kg |
| Housing Material | Acetal (POM) |
| Standard Cable | 3 m integrated |
| Brand | Pro-Oceanus |
|---|---|
| Origin | Canada |
| Model | Solu-Blu CO2 |
| Measurement Principle | Membrane Equilibration with NDIR Detection |
| CO₂ Range | 0–50 mg/L |
| pCO₂ Range | 0–10,000 µatm |
| Accuracy | ±3% of full scale (pCO₂) |
| Response Time (t₆₃) | 4 min (pCO₂) |
| Operating Depth | 0–50 m |
| Temperature Range | 0–35 °C |
| Power Input | 7–24 VDC |
| Power Consumption | 90 mW (RS232 + 0–5 V), up to 60 mA max |
| Output Options | RS-232 (ASCII), 0–5 V analog, 4–20 mA analog |
| Sampling Interval | Configurable down to 2 s |
| Housing Material | Acetal |
| Dimensions | 19.68 cm (L) × 4.76 cm (Ø), 25.68 cm with connector |
| Weight | 0.47 kg |
| Pressure Compensation | Integrated |
| Temperature & Humidity Compensation | Automatic |
| Salinity Input | External compensation supported |
| Warm-up Time | 3 min |