PSI (Czech Republic)
Filter
Showing 31–36 of 36 results
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | PlantScreen-R |
| Type | Mobile Field-Deployable Plant Phenotyping Platform |
| Standard Imaging Modules | RGB (5 MP), FluorCam Chlorophyll Fluorescence (35 × 35 cm FOV) |
| Optional Modules | VNIR/SWIR Hyperspectral Imaging, NIR Imaging (900–1700 nm), Thermal IR Imaging (640 × 480, 30 mK sensitivity), 3D Laser Scanning |
| Max Plant Height Capacity | 100 cm |
| Frame | Adjustable Aluminum Rover Chassis with Motorized Drive Wheels |
| Compliance | Designed for GLP-aligned field phenotyping workflows, compatible with ISO 22057 (Plant Phenotyping — Terminology and Functional Requirements), ASTM E2912 (Standard Guide for In Situ Spectral Reflectance Measurements) |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | Rod-Type Smart LED Light Source |
| Light Output Range | 0–2000 µmol(photon)·m⁻²·s⁻¹ (at 50 cm, customizable) |
| Spectral Options | Standard 5700 K Cool White + Optional Blue, Red, Far-Red LEDs |
| Dimming Control | 5–100% continuous, channel-specific |
| IP Rating | IP65 |
| Cooling | Passive (LED bars), Active (control cabinet, optional) |
| Power Supply | AC 90–305 V, 50/60 Hz |
| Dimensions (Std.) | 998 × 160 × 965 mm |
| Weight (Std.) | 24 kg |
| Operating Temperature | −20 to +40 °C |
| Interface | 1× Power Input, 2× RS485 ports |
| Optional Sensors | Quantum Sensor (PAR), Temperature Probe |
| Software | Light Studio 485, Light Manager (LAN/internet-enabled) |
| Max. Stages per Program | 224 (optional) |
| Compliance | CE, RoHS, IEC 60529 (IP65), IEC 61000-6-3 (EMC) |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | SL3500 |
| Light Output | 0–3,000 µmol(photon)·m⁻²·s⁻¹ at 20 cm |
| Spectral Range | UVA to Far-Red (e.g., 447 nm, 617 nm, 627 nm, 530 nm, 735 nm) |
| LED Array Size Options | 13×13 cm (SL3500-A), 20×20 cm (SL3500-B/C), 30×20 cm (SL3500-D/E) |
| LED Count | 72–240 + 4 far-red LEDs (SL3500-E) |
| Control Precision | 1–100% continuous intensity modulation |
| Temporal Resolution | 50 µs flash pulses (with LC 500 controller) to multi-hour cycles |
| Communication Interface | I²C |
| Power Consumption | 75–300 W |
| Input Voltage | 90–240 V AC |
| LED Lifetime | 60,000–70,000 h |
| Cooling | Integrated active thermal management |
| Software | Light Studio 485 |
| Optional Controllers | LC 100 (4-channel, microsecond pulse), LC 500 (multi-channel, programmable waveform synthesis) |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | SpectraPen LM510 |
| Spectral Range | UVIS 340–780 nm or NIR 640–1050 nm (configurable) |
| FWHM | 7 nm |
| Stray Light | −30 dB |
| Wavelength Repeatability | ±0.5 nm |
| Integration Time | 5 ms – 10 s |
| Detector | 256-pixel linear CCD |
| Cosine Corrector | Integrated, orientation-selectable (H or V) |
| Display | 240×320 pixel color touchscreen |
| Memory | 16 MB (≥4,000 spectra) |
| GPS | Built-in |
| Connectivity | USB + Bluetooth |
| Battery Life | Up to 48 h continuous operation |
| Dimensions | 180 × 75 × 40 mm |
| Weight | 300 g |
| IP Rating | Splash-resistant housing |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −20–70 °C |
| Data Output | Irradiance (μW·cm⁻²·nm⁻¹), Photosynthetic Photon Flux Density (PPFD) spectrum (μmol·m⁻²·s⁻¹·nm⁻¹), Illuminance (lux), PAR (μmol·m⁻²·s⁻¹), CIE 1931 chromaticity coordinates, CCT, CRI, vCIE, user-defined spectral integrals |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | SpectraPen SP110 |
| Spectral Range | SP110-UVIS: 340–780 nm |
| SP110-NIR | 640–1050 nm |
| Spectral Resolution (FWHM) | UVIS: 9 nm, NIR: 8 nm |
| Wavelength Repeatability | ±0.5 nm |
| Detector | 256-pixel linear CCD array |
| A/D Conversion | 16-bit |
| Dynamic Range | 1:4300 (high gain), 1:13000 (low gain) |
| Integration Time | 5 ms – 10 s |
| Display | 240×320 pixel TFT touchscreen (65,535 colors) |
| Onboard Memory | 16 MB (≥4000 spectra) |
| Power | Rechargeable Li-ion battery, USB-charged |
| Battery Life | Up to 48 h continuous operation |
| Dimensions | 150 × 75 × 40 mm |
| Weight | 300 g |
| Enclosure | Splash-resistant housing |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −20–70 °C |
| Connectivity | USB 2.0 + Bluetooth 4.0 |
| Optical Interface | SMA905 connector, 0.22 NA single-fiber probe |
| Stray Light | −30 dB |
| Compliance | CE, RoHS |
| Optional Accessories | Cosine corrector (for irradiance measurement), 1-m fiber optic probe |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | SpectraPen mini |
| Spectral Range | 340–850 nm |
| Spectral Resolution (FWHM) | 15 nm |
| Wavelength Repeatability | ±0.5 nm |
| Integration Time | 1 ms – 5 s |
| ADC Resolution | 16-bit |
| Connectivity | Bluetooth 4.2 |
| Operating System | Android 5.0+ |
| Dimensions | 50 × 70 × 28 mm |
| Weight | 60 g |
| IP Rating | Splash-resistant housing |
| Battery | 650 mAh Li-ion, USB-rechargeable |
| Operating Temperature | 5–55 °C |
| Storage Temperature | −20–70 °C |