PSI (Czech Republic)
Filter
Showing 1–30 of 36 results
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | AquaPen AP110 |
| Detection Limit | 0.5 µg Chl/L |
| Excitation Wavelengths | 455 nm (blue), 620 nm (red) for AP110-C |
| Emission Detection Range | 667–750 nm |
| Optical Configurations | AP110-C (cuvette-based, 4 mL volume, OD680 & OD720 capability), AP110-P (submersible probe) |
| Time Resolution | 10 µs (100,000 measurements/s) for OJIP kinetics |
| Fluorescence Parameters | >50 standard and derived parameters including F₀, Fₘ, Fᵥ/Fₘ, ΦPSII, NPQ, Rfd, Area, Mo, Sm, PI_ABS, ABS/RC, TR₀/RC, ET₀/RC, DI₀/RC, and 26 OJIP-specific indices |
| Light Sources | Measuring light (0.09 µmol photons/m²·s, 10–100% adjustable), Actinic light (10–1000 µmol photons/m²·s), Saturating pulse (up to 3000 µmol photons/m²·s, 11–100% adjustable) |
| Data Storage | 16 MB flash memory (≈149,000 data points) |
| Power | Rechargeable 2000 mAh Li-ion battery (48 h continuous operation) |
| Dimensions | 165 × 65 × 55 mm (body only), Weight: 290 g |
| Environmental Rating | 0–55 °C operating, 0–95% RH (non-condensing) |
| Connectivity | Dual-mode Bluetooth 5.0 (20 m range, 3 Mbps max) + USB 2.0 |
| Integrated GPS | Yes (1.5 m horizontal accuracy) |
| Software | FluorPen v1.1 (Windows 7+, Excel export, kinetic curve visualization, remote instrument control, audit-ready data logging) |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam GFP/Chl |
| Imaging Area | 40 mm × 40 mm |
| CCD Sensor | TOMI-2, 1360 × 1024 pixels, 16-bit A/D, 20 fps max |
| Excitation Wavelengths | 610–620 nm (Measuring Light), 440–450 nm (Actinic & Saturating Light), 735 nm (Far-Red Light) |
| Irradiance | Up to 4500 µmol(photon)·m⁻²·s⁻¹ (Saturating Light), 1200 µmol(photon)·m⁻²·s⁻² (Actinic Light) |
| Filter Options | Red Chlorophyll Fluorescence Filter, Green GFP-Specific Filter |
| Spectral Detection Range | 400–1000 nm |
| Weight | 2 kg |
| Dimensions | 194 × 182 × 280 mm |
| Power Supply | 100–240 V AC or Optional Field Battery Pack (≥10 h operation) |
| Operating Environment | 5–40 °C, 0–90% RH (non-condensing) |
| Compliance | Firmware-upgradable BIOS, GLP/GMP-ready data logging with timestamped auto-storage |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | Fluorcam |
| Image Resolution | 12-bit, 512 × 512 pixels |
| Frame Rate | 50 fps |
| Data Interface | USB 2.0 |
| Spatial Resolution | ~1 mm (macro mode) |
| Excitation Sources | High-power LED arrays (450 nm, 625 nm, white), optional halogen lamp with shutter/LCD for continuous actinic light and saturating pulses |
| Detection | High-sensitivity cooled CCD camera with spectral response optimized for chlorophyll *a* fluorescence (680–750 nm) |
| Software | FluorCam 7.x with programmable protocol engine, ROI-based kinetic analysis, multi-parameter false-color mapping, and GLP-compliant audit trail (optional FDA 21 CFR Part 11 module) |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model Variants | Desktop, Floor-standing, Large Floor-standing |
| Excitation Light Sources | UV–NIR LED Array (365 nm, 450 nm, 470 nm, 490 nm, 520 nm, 590 nm, 630 nm, 735 nm, White Cold LED) |
| Fluorescence Detection Channels | Adjustable via Motorized Filter Wheel (FRET-compatible filters for GFP, RFP, YFP, BFP, CFP, SYBR Green, DAPI, etc.) |
| Imaging Area | Up to 35 × 35 cm |
| Sample Height Range | 20–100 cm (motorized adjustable stage) |
| Measurement Modes | PAM-modulated chlorophyll fluorescence imaging, OJIP transient kinetics imaging, multicolor steady-state fluorescence imaging, chlorophyll distribution mapping, fluorescent protein expression profiling, secondary metabolite fluorescence profiling |
| Software | FluorCam 7.0 with automated protocol scheduling, time-stamped data archiving, GLP-compliant audit trail, and FDA 21 CFR Part 11-ready user access control |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam |
| Detector | High-sensitivity CCD (400–1000 nm, 512×512 px, 8.2×8.4 µm pixel size) |
| Frame Rate | Up to 50 fps |
| Fluorescence Parameters | F₀, Fₘ, Fᵥ, F₀′, Fₘ′, Fᵥ′, QY(II), NPQ, ΦPSII, Fᵥ/Fₘ, Fᵥ′/Fₘ′, Rfd, qN, qP, ETR, and >50 additional derived parameters |
| Actinic Light Sources | White, blue (450 nm), red (620 nm) |
| Measuring Light | 620 nm red LED, pulse width 10–100 µs adjustable |
| Far-Red Light | 735 nm IR LED |
| Uniform Illumination Area | 2.5 × 2.5 cm |
| Excitation Modes | Static or dynamic light regimes |
| Software-Controlled Protocols | Fᵥ/Fₘ, Kautsky induction kinetics, fluorescence quenching analysis, light-response curves, custom script-based experiments |
| Data Interface | USB 2.0 |
| Power Supply | AC adapter or rechargeable battery (field operation) |
| Weight | 1.8 kg |
| Optional Accessories | Handheld OJIP fluorometer module, rugged tablet-based industrial PC |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | PlantScreen Conveyor-Belt |
| Imaging Area | 35 × 35 cm |
| Conveyor Length | 400 cm |
| Positioning Accuracy | ±0.1 mm |
| Scan Speed | up to 150 mm/s |
| Fluorescence Imaging | Modulated Red LED (620 nm), Far-Red LED (735 nm), Dual-Color Actinic Light (Red + Blue / Red + Cool White) |
| CCD Options | 720 × 560 @ 50 fps (GFP-compatible) or 1360 × 1024 @ 20 fps |
| Fluorescence Parameters | Fo, Fo′, Fs, Fm, Fm′, Fv, NPQ, QY, Rfd, and >50 derived metrics |
| RGB Sensor | 2560 × 1920, 1/2.5″ CMOS, 2.2 µm pixel size |
| Thermal Imaging (optional) | 640 × 480, NETD < 0.05 °C @ 30 °C, 20–120 °C range |
| Software | PSI PhenotypeDB™ with automated protocol scheduling, GLP-compliant audit trail, remote web access, role-based user permissions, and real-time data visualization |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | PolyPen Aqua PA210 |
| Spectral Range (UVIS) | 380–790 nm |
| Spectral Range (NIR) | 640–1050 nm |
| Optical Resolution (FWHM) | 8 nm |
| Stray Light | −30 dB |
| Optical Aperture | 7 mm |
| Measurement Chamber Volume | 4 mL |
| Light Source | Pulsed Xenon Lamp |
| OD Wavelengths (UVIS) | 600, 680, 735, 750 nm |
| OD Wavelengths (NIR) | 680, 735, 750 nm |
| Display | 240 × 320 px TFT touchscreen (65,535 colors) |
| Onboard Memory | 16 MB (≥4,000 spectra) |
| ADC | 16-bit |
| Dynamic Range | 1:4,300 (high gain), 1:13,000 (low gain) |
| Scan Time | ~100 ms per spectrum |
| GPS Accuracy | <1.5 m (CE-certified module) |
| Dimensions | 150 × 75 × 40 mm |
| Weight | 300 g |
| Enclosure | IP54-rated splash-resistant housing |
| Battery | Rechargeable 2600 mAh Li-ion (USB charging) |
| Operating Time | Up to 48 h continuous measurement |
| Operating Temp. | 0–55 °C |
| Storage Temp. | −10–60 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | PolyPen RP-410 |
| Spectral Range (UVIS) | 380–790 nm |
| Spectral Range (NIR) | 640–1050 nm |
| Spectral Resolution (FWHM) | 8 nm |
| Stray Light | –30 dB |
| Optical Aperture | 7 mm |
| Scan Time | ~100 ms |
| Display | 240 × 320 pixel color touchscreen (65,535 colors) |
| Memory | 32 MB (≥8,000 spectra) |
| ADC | 16-bit |
| Dynamic Range | 1:4,300 (high gain), 1:13,000 (low gain) |
| GPS | Integrated |
| Connectivity | USB + Bluetooth |
| Power | Rechargeable Li-ion battery |
| Battery Life | Up to 48 h continuous operation |
| Dimensions | 150 × 75 × 40 mm |
| Weight | 300 g |
| Enclosure | Splash-resistant housing |
| Operating Temperature | 0–50 °C |
| Storage Temperature | –20–70 °C |
| Calibration Standard (optional) | >99% Lambertian reflectance, UV–VIS–NIR flat-field (±1%) |
| Brand | PSI (Czech Republic) |
|---|---|
| Model | AquaPen AP110 |
| Probe Types | AP110-C (cuvette-based) & AP110-P (immersion probe) |
| Excitation Wavelengths | 455 nm (blue), 620 nm (red) for fluorescence |
| Detection Limit | 0.5 µg Chl/L |
| Time Resolution | 10 µs (100,000 measurements/s) for OJIP kinetics |
| Data Storage | 16 MB (~149,000 data points) |
| Dimensions | 165 × 65 × 55 mm |
| Weight | 290 g |
| Operating Temperature | 0–55 °C |
| Humidity Range | 0–95% RH (non-condensing) |
| Power | Rechargeable Li-ion battery, 48 h continuous operation |
| Communication | Bluetooth + USB + integrated GPS |
| Software | FluorPen v1.1 (Windows 7+) |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam FC 00-C/1010GFP |
| Imaging Area | 13 × 13 cm uniform LED illumination |
| Camera Resolution | 1392 × 1040 pixels (optional: 640 × 480 or 512 × 512) |
| Temporal Resolution | up to 1 µs for fast fluorescence induction kinetics |
| Filter Wheel | motorized 8-position |
| Excitation Wavelengths | 384 nm (BFP), 395–397 nm (wtGFP), 488 nm (EGFP), customizable LED arrays |
| Emission Detection | configurable bandpass filters (e.g., 469/35 nm, 532/28 nm) |
| Software | FluorCam v7.x with automated dark adaptation, ROI-based kinetics, GLP-compliant audit trail, Excel export, barcode support |
| Compliance | Compatible with ASTM E2595-22 (fluorescence imaging standards), supports 21 CFR Part 11–compliant user access control and data integrity workflows |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam Large-Scale Plant Chlorophyll Fluorescence and Multispectral Imaging Platform |
| Imaging Area | 35 × 35 cm |
| CCD Resolution | 1360 × 1024 pixels |
| Frame Rate | up to 20 fps at full resolution |
| A/D Depth | 16-bit (65,536 gray levels) |
| Pixel Size | 6.45 µm × 6.45 µm |
| Excitation Wavelengths | 320–400 nm (UV-A), 450 nm (blue), 620 nm (red), white light, 735 nm (NIR) |
| Filter Wheel | 7-position motorized |
| Adjustable Imaging Height | 350–1350 mm |
| Compliance | ASTM E2912, ISO 17025-compatible workflow support, GLP/GMP-ready data audit trail (via software timestamping and protocol versioning) |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam Large-Scale Version |
| Imaging Area | 35 × 35 cm |
| CCD Resolution | 1360 × 1024 pixels |
| Frame Rate | up to 20 fps at full resolution |
| A/D Depth | 16-bit (65,536 gray levels) |
| Pixel Size | 6.45 µm × 6.45 µm |
| Adjustable Platform Height | 350–1350 mm |
| Excitation Sources | 620 nm red, dual-color (620 nm + cool white), optional blue/UV/IR LEDs |
| Filter Wheel | 7-position motorized |
| Standard Fluorescence Parameters | >50 chlorophyll fluorescence parameters (e.g., Fv/Fm, ΦPSII, NPQ, qP, Rfd) |
| Optional Modules | UV-induced multispectral fluorescence (F440, F520, F690, F740), GFP/YFP imaging, PAR absorption & NDVI imaging, IR thermography (640 × 512, -25 to +150 °C, 30 mK sensitivity) |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam Mobile |
| Imaging Area | 35 × 35 cm |
| Adjustable Height Range | 20–150 cm |
| CCD Sensor | 2/3″, 1392 × 1040 pixels (15 fps), pixel size 6.45 µm |
| Excitation Sources | Orange, white & NIR LEDs (72 × 72 cm panel, 3 × 64 LEDs) |
| Actinic Lights | Dual-color, 350 & 550 µmol photons·m⁻²·s⁻¹ |
| Saturation Pulse | Up to 3500 µmol photons·m⁻²·s⁻¹ |
| Fluorescence Parameters | >50 including F₀, Fₘ, Fᵥ/Fₘ, NPQ, QY, Rfd, qP, qN, ΦPSII, etc. |
| Data Acquisition | Time-stamped automated protocols, USB 2.0 (480 Mbit/s) |
| Power Supply | 380 V three-phase AC or optional DC generator unit |
| IP Rating | Optional waterproof housing for field use |
| Dimensions | 192 × 125 × 100 cm (H × W × D) |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam Mobile |
| Imaging Sensor | 1392×1040 CCD, 20 fps, 6.45 µm pixel size |
| Excitation Sources | 4+1 configurable LED array (red, cool white, UV 320–400 nm), optional blue/green/cyan/FAR LEDs |
| Filter Wheel | 7-position motorized, with Chl-F, MCF, GFP/YFP, F440/F520/F690/F740 filters |
| Fluorescence Parameters | >60 quantitative metrics including Fo, Fm, Fv/Fm, NPQ, QY, PARabs, Rfd, BGF, UV-Chl-F ratios |
| NDVI & PAR Absorption | Optional dual-wavelength (630/735 nm) LED module |
| Thermal Imaging (optional) | Uncooled VOx microbolometer, 640×512 pixels, 7.5–13.5 µm, -25 to 150 °C, sensitivity ≤30 mK @ 30 °C |
| RGB Imaging (optional) | 2592×1944 scientific-grade CMOS, 54 dB SNR, 1–40× zoom |
| Power Supply | 90–240 V AC |
| Compliance | CE-marked, ISO/IEC 17025-compatible data acquisition architecture, FDA 21 CFR Part 11-ready software audit trail (with optional configuration) |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam Open-Field Multispectral Fluorescence Imaging System |
| Imaging Area | 13 × 13 cm (Standard), 20 × 20 cm (Large Format) |
| CCD Resolution | 1392 × 1040 pixels, Pixel Size: 6.45 µm |
| Excitation Wavelengths | UV (320–400 nm), Blue (450 nm), Red (618 nm), Far-Red (735 nm), Green (530 nm), Cyan (490 nm) |
| Emission Detection Bands | F440, F520, F690, F740, GFP (509 nm), YFP (527 nm), Chl-F, BGF, PARabs, NDVI |
| Actinic Light Intensity | Up to 3000 µmol·m⁻²·s⁻¹ (configurable) |
| Saturation Flash | Up to 6000 µmol·m⁻²·s⁻¹ |
| Measurement Pulse Duration | 10–100 µs |
| Filter Wheel | 7-position motorized |
| Software | FluorCam v8.x with GLP-compliant audit trail, protocol editor, ROI-based quantification, dual averaging modes (signal-then-average / average-then-signal), time-stamped automated acquisition |
| Compliance | Designed for ISO/IEC 17025-aligned labs |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam Portable |
| Imaging Area | 40 mm × 40 mm |
| Sensor | TOMI-2 CCD, 1360 × 1024 pixels, 16-bit A/D, 20 fps @ full resolution |
| Excitation Light | 610–620 nm (measuring light), 5300 K white light (actinic & saturating light, up to 4500 µmol photons/m²·s), 710–740 nm far-red LEDs (for Fo′ determination) |
| Spectral Detection Range | 400–1000 nm |
| Weight | 2 kg |
| Dimensions | 194 × 182 × 280 mm |
| Power Supply | AC 100–240 V or optional field battery pack (≥10 h operation) |
| Operating Conditions | 5–40 °C, 0–90% RH (non-condensing) |
| Compliance | CE, RoHS, firmware-upgradable BIOS |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam-96 |
| Measurement Principle | Dual-modality chlorophyll fluorescence imaging + fiber-optic dissolved oxygen sensing |
| Throughput | 96 parallel samples |
| Fluorescence Parameters | >50 including Fo, Fm, Fv/Fm, ΦPSII, NPQ, qL, ETR, Rfd, QY_Ln |
| Oxygen Measurement | Fiber-optic sensor, ±0.1% O₂ @ 1% O₂, 0.01% O₂ resolution, 10–20 Hz sampling rate |
| Chamber Material | Sterilizable transparent polystyrene |
| Dimensions (O₂ module) | 162 × 102 × 32 mm |
| Weight (O₂ module) | 670 g |
| Temperature Sensor | 0–50 °C, ±0.5 °C accuracy, 0.012 °C resolution |
| Pressure Sensor | 300–1100 mbar, ±6 mbar accuracy, 0.11 mbar resolution |
| Software | FluorCam v7.x with GLP-compliant audit trail, protocol editor, ROI-based kinetic analysis, signal averaging mode for low-biomass samples |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam-MultiSpectral Modular Plant Phenotyping Imaging System |
| Thermal Imager | Uncooled VOx microbolometer, 640×512 px, 7.5–13.5 µm, −25 to +150 °C, NETD ≤ 0.03 °C @ 30 °C |
| Fluorescence Imaging | UV/Blue/Red excitation, F440/F520/F690/F740 detection, 1360×1024 CCD, 20 fps |
| RGB Imaging | 2592×1944 sensor, 1–40× zoom, FOV 6.1×7.9 mm (40×) to 20.8×25.4 mm |
| NDVI/PAR Module | 630 nm & 740 nm LEDs |
| Max Sample Height | 50 cm |
| Compliance | CE-marked, ISO/IEC 17025 traceable calibration documentation available |
| Software | FluorCam v7.x with GLP-compliant audit trail, FDA 21 CFR Part 11 optional modules |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FMT150 |
| Volume Options | 400 mL / 1000 mL / 3000 mL |
| Temperature Control Range | 5–75 °C (dependent on vessel type) |
| PAR Intensity | Up to 3000 µmol photons·m⁻²·s⁻¹ (configurable per wavelength) |
| Light Sources | Red, Blue, White LEDs (single/dual/multi-spectral) |
| Fluorescence Detection | Dual-modulation chlorophyll fluorometer (F₀, Fₘ, Fₘ′, QY, ΦPSII) |
| Optical Density | OD₆₈₀ & OD₇₂₀ via PIN photodiode + bandpass filter (665–750 nm) |
| Gas Control | Optional GMS high-precision gas mixing system (N₂, air, CO₂, O₂) |
| pH/DO/CO₂ Sensing | Optional calibrated electrochemical sensors |
| Pump Capacity | Up to 8 per unit (PP600 peristaltic pumps) |
| Software | PSI FMT150 Control Suite (Basic & Advanced editions, FDA 21 CFR Part 11–compliant audit trail optional) |
| Compliance | CE-marked |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | Fyto-A2/A3/B2/B3/C/MULTI Series |
| Light Source Type | Programmable Multi-Spectral LED Array |
| Active Area Options | 27 × 81 cm or 27 × 41 cm |
| Spectral Channels | Cool White (5000–6500 K), Deep Red (660 nm), Far-Red (735 nm), plus optional Blue (450 nm), Green (530 nm), IR (850 nm) |
| Photon Flux Density | Up to 1600 µmol(photon)·m⁻²·s⁻¹ (at 50 cm, MULTI configuration) |
| Intensity Control Range | 0–100% in 0.1% increments |
| Uniformity | ±5% across active area (measured per ASTM E2917-20) |
| LED Lifetime | 60,000–70,000 h at rated output |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Operating Temperature | 0–55 °C |
| Relative Humidity | 0–80% RH (non-condensing) |
| Control Interface | RS-485, USB, Ethernet (Light Studio v4.85) |
| Compliance | CE, RoHS, IEC 61000-6-3 (EMI), IEC 61000-6-2 (Immunity) |
| Software Features | Predefined diurnal cycles, cloud simulation, pulse modulation (µs–h), multi-channel spectral blending, GLP-compliant audit trail (optional) |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | Fyto-Panel |
| Dimensions | 27 × 81 cm or 27 × 41 cm |
| Maximum Photosynthetic Photon Flux Density (PPFD) | 2400 µmol·m⁻²·s⁻¹ at 50 cm |
| Spectral Channels | Cool White + Far-Red + Deep Red (standard) |
| LED Lifetime | 60,000–70,000 h |
| Power Consumption | 210 W (A), 360 W (B), 580 W (C), 600 W (MULTI) |
| Operating Temperature | 0–55 °C |
| Relative Humidity | 0–80% RH (non-condensing) |
| Control Interface | USB/RS-485 |
| Software Features | Programmable light regimes (duration, intensity, spectral composition, modulation waveforms), cloud cover simulation, dawn/dusk transition modeling, GLP-compliant audit trail (via Light Studio Pro) |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | Mobile PlantScreen Phenotyping Imaging Platform |
| Category | Import |
| Distribution Type | Authorized Distributor |
| Pricing | Upon Request |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | MP100 |
| Measurement Principle | Pulse-Amplitude-Modulated (PAM) Chlorophyll Fluorescence |
| OJIP Time Resolution | 10 µs (100,000 samples/s) |
| Fluorescence Parameters | >50 including F₀, Fₘ, Fᵥ/Fₘ, ΦPSII, NPQ, Rfd, PAR, PI_ABS, ABS/RC, Mo, Area, Sm |
| Light Sources | Adjustable blue LED (470 nm), optional multi-wavelength LEDs |
| Actinic Light Range | 0–1000 µmol(photon)·m⁻²·s⁻¹ |
| Saturation Pulse Intensity | 0–3000 µmol(photon)·m⁻²·s⁻¹ |
| Measuring Light Intensity | 0–0.09 µmol(photon)·m⁻²·s⁻¹ |
| PAR Sensor | Cosine-corrected, 400–700 nm, ±5% accuracy, output in µmol(photon)·m⁻²·s⁻¹ |
| Memory Capacity | 16 MB, up to 100,000 timestamped measurements |
| Power Options | Rechargeable 12 Ah lead-acid battery (operating range +10 to +40 °C) or non-rechargeable 5.5 Ah Li-SOCl₂ battery (–40 to +60 °C) |
| Waterproof Rating | IP68 (MP100-E: terrestrial |
| MP100-A | submersible up to 2 m standard, customizable to 10 m) |
| Dimensions | 135 × 65 × 33 mm |
| Display | 2×8 character LCD |
| Interface | USB, optional GSM/GPRS or LoRaWAN for remote data transmission |
| Software | FluorPen v1.1 (Windows 7+) for data export (CSV, Excel), kinetic curve visualization, and parameter batch analysis |
| Compliance | Designed for GLP-aligned long-term field deployment |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | PlantPen N110 |
| Measurement Principle | Dual-Wavelength Reflectance Spectroscopy (565 nm & 760 nm) |
| Derived Parameter | Normalized Difference Greenness Index (NDGI) and NDGI-Calibrated Leaf Nitrogen Content (%) |
| Preloaded Calibrations | Wheat, Barley, Maize |
| Detector | PIN Photodiode with Bandpass Filters |
| Spectral Range | 500–800 nm |
| Data Storage | >100,000 measurements (16 MB internal memory) |
| Display | Graphical LCD |
| Interface | Bluetooth 5.0 (up to 20 m, 3 Mbps) + USB-C |
| Integrated GPS | Yes (CEP ≤1.5 m) |
| Power | Rechargeable 2000 mAh Li-ion battery (70 h continuous operation, auto-shutdown after 5 min idle) |
| Operating Temp. | 0–55 °C |
| RH | 0–95 % non-condensing |
| Dimensions | 135 × 65 × 33 mm |
| Weight | 188 g |
| Software | FluorPen 1.1 (Windows 7+) — supports data export to Excel, statistical averaging, time-series plotting, and calibration curve management |
| Brand | PSI (Czech Republic) |
|---|---|
| Model | PlantPen PRI 210 / NDVI 310 |
| Measurement Principle | Dual-wavelength reflectance ratio spectroscopy |
| PRI Band | 531 nm & 570 nm (detection range: 500–600 nm) |
| NDVI Band | 635 nm (red) & 760 nm (NIR) (detection range: 620–750 nm) |
| PRI Calculation | (R₅₃₁ − R₅₇₀) / (R₅₃₁ + R₅₇₀) |
| NDVI Calculation | (Rₙᵢᵣ − Rᵣₑ ) / (Rₙᵢᵣ + Rᵣₑ ) |
| Data Storage | 100,000 measurements (16 MB internal flash) |
| Connectivity | Bluetooth 1.1 + USB 2.0 |
| GPS | Integrated |
| Display | Graphical LCD |
| Power | Rechargeable Li-ion battery (70 h continuous operation) |
| Dimensions | 135 × 65 × 33 mm |
| Weight | 188 g |
| Operating Temp. | 0–55 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| IP Rating | Sealed waterproof keypad |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | PlantScan |
| Import Status | Imported |
| Type | Automated Plant Phenotyping System with Chlorophyll Fluorescence, RGB 3D, Thermal, NIR, and Hyperspectral Imaging |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | PlantScreen Automated High-Throughput |
| Compliance | CE, ISO 9001-certified manufacturing |
| System Capacity | 2160 custom agar plates (129 × 129 × 16.5 mm) |
| Imaging Sensors | CMOS, 12.36 MP (4112 × 3006), global shutter, 12-bit depth, GigE interface |
| Chlorophyll Fluorescence Excitation | 620 nm, 5700 K white, 735 nm far-red |
| Multispectral Fluorescence Excitation | 365 nm UV, 445/470/505/530/590 nm LEDs |
| VNIR Hyperspectral Range | 350–900 nm, 2 nm FWHM resolution, 480 spectral bands, 45 fps |
| LED Growth Light | Adjustable R:FR ratio (0.5–0.82), max irradiance 400 µmol/m²·s at 30 cm |
| Stratification Cabinet | Precise 5 °C dark control, 720-plate capacity |
| Environmental Control | Optional GMO-compliant growth chamber with HEPA + UV-C sterilization |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | PlantScreen Conveyor Edition |
| Compliance | CE-marked, ISO 9001-certified manufacturing |
| Application Domain | Automated plant phenotyping, non-invasive physiological & structural imaging |
| Imaging Modalities | Chlorophyll fluorescence, RGB 3D, thermal IR, NIR water status, VNIR/SWIR hyperspectral |
| Throughput Capacity | Up to 200+ plants per day (standard tray configuration) |
| Enclosure Dimensions | 150 × 150 × 220 cm (L×W×H), light-isolated |
| Data Management | MySQL-based relational database with audit-trail logging, GLP-compliant metadata tagging |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | PlantScreen Conveyor Edition |
| Compliance | CE, EN 60529, EN 55011, 2006/42/EC, 2004/108/EC, 73/23/EEC |
| Data Storage Capacity | 12 TB MySQL Database |
| Imaging Throughput | Up to 100 plants per 100 minutes (protocol-dependent) |
| Conveyor Capacity | Standard 50 pots (expandable to 400) |
| Max Plant Height | 200 cm |
| Weighing Accuracy | ±0.2 g (small plants), ±2 g (large plants) |
| Irrigation Flow Rate | 3 L/min |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | PlantScreen SC |
| Mobility | Integrated casters for intra-greenhouse repositioning |
| Standard Plant Capacity | Up to 70 cm height, 50 cm canopy diameter |
| Core Imaging Modules | FluorCam chlorophyll fluorescence imaging + RGB 3D morphometric imaging |
| Optional Modules | 3D laser triangulation scanning, hyperspectral imaging (400–1000 nm), thermal infrared imaging (7.5–14 µm), NIR imaging |
| Sample Handling | Barcode-scanned standardized trays (5×4, 2×2, 1×2, 1×1 configurations |
| Environmental Monitoring | Integrated temperature & relative humidity sensors with time-synchronized logging |
| Software Suite | PSI PlantScreen Control & Analysis Suite (includes experiment scheduling, automated acquisition, batch processing, relational database management, GLP-compliant audit trail) |