| Brand | Qilin |
|---|---|
| Model | QL-5800A |
| Instrument Type | Floor-standing |
| Excitation Method | Spark discharge |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 750 mm |
| Grating Groove Density | 2400 lines/mm |
| Wavelength Range | 130–600 nm |
| Number of Channels | 32 |
| Operating Environment | Argon-purged optical chamber |
| Optical Stability | Thermostatically controlled at 38 °C ±0.2 °C |
| Dimensions (L×W×H) | 1120 × 750 × 920 mm |
| Net Weight | 266 kg |
| Brand | Qilin |
|---|---|
| Model | QL-CS30D |
| Analysis Method | Carbon – Gas Volumetric Method |
| Measurement Range | C: 0.02–6.00 wt% |
| S | 0.005–0.300 wt% |
| Sample Mass Options | 0.25 g / 0.5 g / 1.0 g (auto-range compensation) |
| Analysis Time | 65 s (with DL1A arc furnace), 85 s for dual-absorption mode |
| Detection Principle | Differential pressure transducer (C) |
| Readout | Direct digital display of mass fraction (%) with thermal printer output |
| Accuracy Compliance | Carbon per GB/T 223.69–1997 |
| Balance Interface | RS232, supports 0–100 g × 0.001 g analytical balance (optional 0.0001 g) |
| Operating Environment | 0–40 °C, 90.658–106.658 kPa |
| Power Supply | AC 220 V ± 10%, 50 Hz |
| Brand | Qilin |
|---|---|
| Model | QL-BS3B |
| Origin | Jiangsu, China |
| Type | Benchtop Optical Emission Analyzer (Cold Light Source) |
| Measurement Principle | Photometric Colorimetry with Dual-Wavelength Compensation |
| Elements Measured | Si, Mn, P, Cr, Mo, Mg (expandable via interchangeable light sources) |
| Range | Mn 0.10–15.00%, Si 0.10–5.00%, P 0.005–0.80%, Cr 0.010–25.0%, Mo 0.010–6.00%, Mg 0.010–0.99% |
| Detection Method | Solid-state photodiode (imported silicon photovoltaic cell) |
| Calibration | Auto-zero and auto-full-scale calibration |
| Curve Storage | 15 preloaded calibration curves |
| Interface | Touch-sensitive membrane keypad with audible feedback |
| Sample Preparation | External fusion (crucible-based), no fluidic valves or tubing |
| Compliance | Designed for ISO/IEC 17025-aligned metallurgical QC labs |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Brand | Qilin |
|---|---|
| Model | QL-CS3000A |
| Analysis Method | Carbon – Gas Volumetric Method |
| Measurement Range | C: 0.02–6.00 wt% |
| S | 0.005–0.300 wt% |
| Sample Mass Options | 0.25 g, 0.5 g, or 1.0 g (auto-adjusted range mapping) |
| Analysis Time | 65 s (with DL1A arc furnace) |
| Detection Principle | Differential pressure transduction (C) |
| Compliance | GB/T 223.69–1997 (C) |
| Operating Environment | 0–40 °C |
| Interface | RS-232 to PC |
| Brand | Qilin |
|---|---|
| Model | QL-CS3000A |
| Origin | Jiangsu, China |
| Analysis Method | CO₂ Gas Volumetry (C), Iodometric Titration (S) |
| C Range | 0.02–6.00 wt% |
| S Range | 0.005–0.300 wt% |
| Sample Mass Options | 0.25 g / 0.5 g / 1.0 g (auto-optimized per range) |
| Analysis Time | 65 s (with DL1A arc furnace), 85 s for dual-absorption mode |
| Compliance | GB/T 223.69–1997 (C), GB/T 223.68–1997 (S) |
| Operating Environment | 0–40 °C, 90.658–106.658 kPa |
| Brand | Qilin |
|---|---|
| Origin | Jiangsu, China |
| Model | QL-HW2000DF |
| Measurement Principle | Infrared Absorption |
| Heating System | High-Energy Arc Furnace |
| Carbon Range | ω(C) 0.0010–10.00% |
| Sulfur Range | ω(S) 0.0005–0.500% |
| Analysis Time | Adjustable 20–60 s (typical 35 s) |
| Weighing Precision | 0.0001 g (0.1 mg) |
| Compliance | GB/T 223.69–1997 (C), GB/T 223.68–1997 (S) |
| Power Supply | Switching-mode, EMI-hardened |
| Brand | Qilin |
|---|---|
| Model | QL-TS-2 |
| Measurement Range (Fast) | 500–1999 °C |
| Continuous Range | 200–1999 °C |
| Thermocouple Type | S, B, R, WRe3/25 |
| Display | 3.5-digit, 5-inch high-brightness red LED (digit height: 127 mm) |
| Operating Temperature | 0–55 °C |
| Storage Temperature | −40–85 °C |
| Humidity (Operating) | <85% RH |
| Humidity (Storage) | <95% RH |
| Power Supply | AC 220 V / 50 Hz, 20 W |
| Dimensions (Single-Side) | 400 × 300 × 110 mm |
| Dimensions (Dual-Side) | 400 × 300 × 130 mm |
| Wireless Band | 868 MHz ISM |
| Line-of-Sight Transmission Distance | ≤200 m |
| Sampling Interval | 20 ms |
| Data Storage | 200 records |
| Output Interfaces (Configurable) | RS485, RS232, isolated BCD, 4–20 mA analog, DC12V audio alarm, thermal printer port |
| Brand | Qilin |
|---|---|
| Model | TS-3 |
| Origin | Jiangsu, China |
| Measurement Time | 240 s |
| CE Range | 3.2–4.8 wt% (±0.1%) |
| C Range | 2.8–4.2 wt% (±0.05%) |
| Si Range | 0.9–3.0 wt% (±0.08%) |
| Display Height | 50 mm |
| Temperature Compensation | 0–40 °C |
| Cup Types | S, R, B, K |
| Compliance | EN 50081-2, EN 50082-2 |
| Temperature Unit | Selectable (°C/°F) |
| Status Indicators | Green (Ready), Yellow (Measuring), Red (Complete) |