Radiant Zemax
Filter
Showing all 13 results
| Brand | Radiant ZEMAX |
|---|---|
| Origin | USA |
| Model | IS-LI |
| Type | Near-Field Imaging Measurement System for Angular Radiometric and Photometric Characterization |
| Application Scope | LED Light Sources, Flat Panel Displays (FPD), Diffusing Materials, Optical Films, Surface Scatter Analysis |
| Brand | Radiant Zemax |
|---|---|
| Origin | USA |
| Model | NFMS0400 / FPMS0400 |
| Type | Near-Field Measurement System for Luminaires |
| Compliance | Supports IESNA LM-79, CIE S 025, ISO/CIE 19476 |
| Software Platform | TrueTest™ v7.0+ |
| Detector Options | ProMetric® Y-series (luminance) and I-series (chromaticity) imaging photometers |
| Angular Range | ±90° in azimuth, ±90° in elevation |
| Spatial Resolution | Up to 9M pixels per image |
| Dynamic Range | ≥1,000,000:1 (typical with HDR acquisition) |
| Calibration Traceability | NIST-traceable luminance & chromaticity standards |
| Brand | Radiant Zemax |
|---|---|
| Origin | USA |
| Model | PM-1200 Series |
| Sensor Type | 12-bit CCD with CIE-matched optical filters |
| Measurement Capabilities | Luminance (cd/m²), Illuminance (lux), Radiance (W/sr·m²), Irradiance (W/m²), Luminous Intensity (cd), Radiant Intensity (W/sr) |
| Spatial Resolution | Up to 2.3 megapixels (configurable by model variant) |
| Dynamic Range | >1,000,000:1 (with electronic exposure control) |
| Compliance | ISO/CIE-compliant photometric and radiometric calibration traceable to NIST |
| Software Platform | ProMetric® v3.x or later (supports ASTM E308, CIE 15:2018, IEC 62368-1, and MIL-STD-3009 NVIS requirements) |
| Brand | Radiant Zemax |
|---|---|
| Origin | USA |
| Model | PM-1400F Series |
| Sensor Resolution | 768×512 / 1536×1024 / 3072×2048 pixels |
| ADC Dynamic Range | 14 bits (16,384 gray levels) |
| Luminance Range | 0.001 to 10¹⁰ nit (with ND filters) |
| Photometric Accuracy | Illuminance ±3%, Luminance (Y) ±3%, Chromaticity (x,y) ±0.003 |
| Short-Term Repeatability | Illuminance <±0.5%, Luminance <±0.5%, Chromaticity ±0.0006 |
| FOV Options | 1°–26° / 3°–50° / 5°–87° |
| Measurement Time (at 100 cd/m²) | 1.8–25 s depending on resolution |
| Interface | USB 2.0 |
| Dimensions | 154 × 242 × 200 mm |
| Weight | 4.8 kg |
| Operating Temperature | 0–30 °C |
| Operating Humidity | 20–70% RH (non-condensing) |
| Photometric Units | cd/m², cd/cm², fL, nit, mnit, W/sr/m², lux, fc, W/m², cd/sr, CIE (x,y), (u′,v′), CCT (K) |
| Brand | Radiant Zemax |
|---|---|
| Origin | USA |
| Model | PM-1600F Series |
| Detector Type | TE-Cooled Scientific CCD |
| Resolution | 512 × 512 or 1024 × 1024 pixels |
| Dynamic Range | 16-bit (65,536 gray levels) |
| Minimum Luminance | 0.0005 cd/m² |
| Maximum Luminance (with ND filters) | 10¹⁰ cd/m² |
| Photometric Accuracy | ±3% for luminance (Y) and illuminance |
| Chromaticity Accuracy | ±0.003 in CIE x,y |
| Short-Term Repeatability | <±0.5% for luminance, ±0.0006 in CIE x,y |
| Measurement Time (at 100 cd/m²) | 2–9 sec depending on resolution and binning |
| FOV Range | 2°–38° (512×512), 5°–80° (1024×1024) |
| Interface | USB 2.0 |
| Dimensions | 154 mm (H) × 242 mm (W) × 200 mm (D) |
| Weight | 4.8 kg |
| Operating Temperature | 0–30 °C |
| Operating Humidity | 20–70% RH (non-condensing) |
| Software | ProMetric® v5.x or later |
| Compliance | ASTM E308, ISO/CIE 11664, CIE 15:2018, USP <1058>, FDA 21 CFR Part 11 (audit trail & electronic signature support) |
| Brand | Radiant ZEMAX |
|---|---|
| Origin | USA |
| Model | ProSource 10 |
| Application Domain | Illumination Engineering & Non-Sequential Optical Design |
| File Format Support | RSM (Radiant Source Model), IESNA LM-63 (.ies), EULUMDAT (.ldt), UGR-compliant output |
| Ray Set Capacity | Up to 2 billion rays per export |
| Data Representation | Full-field luminance images with spatial, angular, and spectral resolution |
| Export Compatibility | Zemax OpticStudio (non-sequential mode), ASAP, LightTools, TracePro, FRED, CODE V |
| Brand | Radiant Zemax |
|---|---|
| Origin | USA |
| Model | RSM |
| Type | Near-Field Source Characterization Data Format |
| Compatibility | ASAP, FRED, LightTools, SimuLux, SPEOS, TracePro, Zemax OpticStudio |
| Measurement Basis | Radiant SIG & PM-NFMS Near-Field Goniophotometers |
| Data Content | Spatial-Angular Luminance Maps, Chromaticity Images (CIE x,y or u′,v′), Spectral Power Distribution (SPD) per Solid Angle |
| Sampling Method | Weighted Importance Sampling (WIS) |
| Regulatory Alignment | Supports ISO/CIE-compliant photometric reporting, GLP-aligned measurement traceability, FDA 21 CFR Part 11–ready audit trails in ProSource v5.3+ |
| Brand | Radiant Zemax |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SIG-300 |
| Pricing | Upon Request |
| CCD Type | Full-frame, thermoelectrically cooled CCD |
| CCD Dynamic Range | 16-bit (65,536:1) |
| Resolution Options | 512 × 512 or 1024 × 1024 pixels |
| FOV (Standard) | 2 mm, 4 mm, 8 mm (512×512) |
| FOV (Micro Extension) | 0.5 mm, 1.2 mm |
| FOV (Large Extension) | 40 mm, 80 mm |
| Color Filter Set | CIE 1931 XYZ tristimulus filters |
| Neutral Density Filters | ND0 to ND5 |
| Polar Rotation Range | −10° to +370° |
| Azimuthal Tilt Limit | ±24° from lamp axis |
| Angular Step Resolution | 0.10°/min |
| Mechanical-Optical-Software Runout | < 0.025 mm |
| System Dimensions | 120 cm × 77 cm × 177 cm |
| Minimum Operating Footprint | 120 cm × 120 cm |
| Mass | 360 kg |
| Structural Frame | Welded steel cast housing with thermal stability design |
| Software Platform | SIG 2.0 — supports luminance, illuminance, chromaticity (CIE x,y |
| Brand | Radiant Zemax |
|---|---|
| Origin | USA |
| Model | SIG-310 |
| CCD Type | Full-frame, thermoelectrically cooled CCD |
| Dynamic Range | 16-bit (65,536:1) |
| Resolution Options | 512 × 512 or 1024 × 1024 pixels |
| FOV (Standard) | 6–160 mm (512×512) |
| FOV (Macro) | 300 mm (512×512 only) |
| Color Filters | CIE 1931 XYZ tristimulus with ND filters (ND0–ND5) |
| Polar Rotation | −10° to +370° |
| Azimuthal Tilt | ±20° from lamp axis |
| Angular Step Resolution | 0.10°/min |
| Mechanical-Optical-Software Runout | ≤0.100 mm |
| System Dimensions | 145 cm × 133 cm × 204 cm |
| Operating Footprint | 343 cm × 312 cm |
| Weight | 640 kg |
| Structural Frame | Welded steel cast body with thermal-stability design |
| Software | SIG 2.0 — supports luminance, illuminance, chromaticity (CIE x,y |
| Brand | Radiant Zemax |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SIG-400 |
| Pricing | Upon Request |
| Brand | Radiant Zemax |
|---|---|
| Origin | USA |
| Model | SIG300 / SIG310 / SIG400 |
| Application Scope | Near-field luminance, chromaticity, and angular intensity distribution measurement of LEDs, lamp modules, and compact light sources |
| Compliance Framework | Supports ASTM E308, CIE 127, IES LM-79, ISO/CIE 11664 (colorimetry), and FDA/ISO 13485-aligned quality documentation workflows |
| Software Integration | Fully compatible with ProSource® v10+ for RSM generation, ray set export (IES, EULUMDAT, ASAP, LightTools, TracePro), GLP/GMP audit trail logging, and 21 CFR Part 11–compliant user access control |
| Brand | Radiant Zemax |
|---|---|
| Origin | USA |
| Model | VisionCAL |
| Type | Imaging Colorimeter-Based Display Calibration System |
| Application | Pixel-Level Luminance & Chromaticity Calibration of LED Displays |
| Compliance | Designed for ISO 11664, CIE S 014-2/E:2022, and ASTM E308-23 workflows |
| Software Architecture | Windows-based, FDA 21 CFR Part 11–ready audit trail support (optional), GLP/GMP-compatible data logging |
| Brand | Radiant Zemax |
|---|---|
| Origin | USA |
| Model | ZEMAX 13 |
| Type | Optical Design & Illumination Simulation Software |
| Compliance | ASTM E284, ISO/CIE 11664 (Colorimetry), USP <1059>, FDA 21 CFR Part 11 (via optional audit trail module) |
| CAD Integration | Native bidirectional sync with SolidWorks®, Autodesk Inventor®, Creo Parametric® |
| File Formats | STEP, SAT, IGES, STL, IES, LDT, ZMX, FRED, ASAP, LightTools® import/export |
| Programming Interface | ZPL (Zemax Programming Language), MATLAB® interoperability, COM/ActiveX, .NET API, user-defined DLL support |
| Optical Engine | Hybrid sequential/non-sequential ray tracing engine with physical optics propagation (Gaussian, Laguerre-Gaussian, TEM modes), BSDF material modeling, GRIN media, polarization & thin-film stack analysis |
| License Type | Perpetual or subscription-based floating/network license |