SURAGUS
Filter
Showing all 7 results
| Brand | SURAGUS |
|---|---|
| Origin | Germany |
| Model | SURAGUS 2530 |
| Measurement Principle | Non-contact Eddy Current |
| Max Scan Area | 300 × 300 mm (12 inch) |
| Sheet Resistance Range | 0.0001–10,000 Ω/□ (accuracy 2–8%) |
| Thickness Range (metal films) | 2 nm – 2 mm |
| Spatial Resolution | Adjustable scan pitch (1/2/5/10 mm) |
| Max Data Points | 1,000,000 per map |
| Measurement Speed | Up to 10,000 points in 5 min |
| Edge Compensation | ±2 mm exclusion zone |
| Sensor Gap Options | 2 / 5 / 10 / 25 mm |
| Brand | SURAGUS |
|---|---|
| Model | EddyCus TF Inline |
| Measurement Principle | Eddy Current |
| Sampling Rate | Up to 1000 Hz |
| Sheet Resistance Range | 0.1 mΩ/sq – 1 kΩ/sq |
| Metal Layer Thickness Range | 2 nm – 2 mm (material-dependent) |
| Resistivity Range | 0.1 mΩ·cm – 1 Ω·cm |
| Dielectric Moisture Detection | Yes |
| Substrate Compatibility | Glass, Foil, Paper, Silicon Wafers, Polymers, Ceramics |
| Operating Environment | Ambient or Vacuum |
| Standoff Distance | Up to 60 mm |
| Channel Capacity | 1–99 independent measurement channels |
| Software Interface | OPC UA, TCP/IP, analog/digital I/O |
| Compliance | Compatible with FDA 21 CFR Part 11 (audit trail via EC Control), GLP/GMP process logging |
| Brand | SURAGUS |
|---|---|
| Origin | Germany |
| Model | EddyCus TF inline |
| Measurement Principle | Non-contact eddy current metrology |
| Sample Environment | In-air and vacuum-compatible (up to 90 °C) |
| Sensor Configurations | Single- to 99-channel modular array |
| Sampling Rate | Up to 1000 Hz |
| Output Interfaces | UDP, TCP, Modbus, .NET libraries, analog/digital I/O |
| Thickness Range (metallic layers) | 2 nm – 2 mm |
| Sheet Resistance Range | 0.0001 – 100,000 Ω/□ (with accuracy 2–8% depending on range) |
| Sensor Options | M-type (80 × 100 × 66 mm), S-type (34 × 48 × 117 mm) |
| Gap Distance | 5 / 10 / 15 / 25 / 50 / 75 mm |
| Compliance | Designed for ISO/IEC 17025-aligned calibration workflows |
| Brand | SURAGUS |
|---|---|
| Origin | Germany |
| Manufacturer Type | OEM Instrument Manufacturer |
| Measurement Principle | Eddy Current Sensing |
| Sampling Rate | Up to 1000 Hz |
| Sheet Resistance Range | 0.1 mΩ/□ to 1 kΩ/□ |
| Metal Layer Thickness Range | 2 nm – 2 mm (material-dependent) |
| Resistivity Range | 0.1 mΩ·cm – 1 Ω·cm |
| Distance-to-Target Gap | Up to 60 mm |
| Compliance | CE, RoHS, ISO 9001-certified design |
| Environmental Operation | Ambient atmosphere or vacuum-compatible |
| Brand | SURAGUS |
|---|---|
| Origin | Germany |
| Model | TF lab 2020 |
| Measurement Principle | Eddy Current |
| Sheet Resistance Range | 0.0001–100,000 Ω/□ (3 accuracy tiers) |
| Thickness Range (e.g., Cu) | 2 nm – 2 mm |
| Max Sample Size | 204 × 204 mm (8″ square) |
| Sensor Gap Options | 1 / 2 / 5 / 10 / 25 mm |
| Accuracy | 1–8% depending on range |
| Dimensions (W×D×H) | 290 × 445 × 140 mm |
| Weight | 10 kg |
| Compliance | CE, RoHS, ISO/IEC 17025-compatible operation |
| Brand | SURAGUS |
|---|---|
| Origin | Germany |
| Model | EddyCus TF lab 2020 |
| Measurement Principle | Eddy Current-Based Non-Contact Resistivity & Thickness Profiling |
| Sample Platform | Open-Frame 204 × 204 mm (8-inch compatible) |
| Resistivity Range | 0.0001–100,000 Ω/□ (3 accuracy tiers: ±1–5% for low/mid range |
| Thickness Range (e.g., Cu) | 2 nm – 2 mm |
| Sensor Gap Options | 1 / 2 / 5 / 10 / 25 mm |
| Dimensions (W×D×H) | 290 × 445 × 140 mm |
| Weight | 10 kg |
| Compliance | Designed for ISO/IEC 17025-aligned lab environments |
| Brand | SURAGUS |
|---|---|
| Origin | Germany |
| Model | TF map 2530 |
| Measurement Principle | Non-Contact Eddy Current Sensing |
| Max Scan Area | 300 × 300 mm (12 inch) |
| Sheet Resistance Range | 0.0001–10,000 Ω/□ (with accuracy 2–8% depending on range) |
| Thickness Measurement | 2 nm – 2 mm (for conductive metal layers, e.g., Al, Cu) |
| Spatial Resolution | Adjustable scan step: 1 / 2 / 5 / 10 mm |
| Measurement Density | Up to 1,000,000 points per scan |
| Edge Exclusion | 2 mm standard |
| Max Sample Thickness / Sensor Gap | 2 / 5 / 10 / 25 mm |
| Typical Scan Time | 0.5–5 min (100 × 100 mm), 1.5–15 min (200 × 200 mm) |
| Compliance | ISO/IEC 17025-compatible operation, supports GLP audit trails |