TAITEC
Filter
Showing 61–90 of 91 results
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | Shake-LR / Shake-XR |
| Timer Range | 1 min – 99 h 59 min |
| Oscillation Speed | 15–160 rpm (Shake-LR), 15–100 rpm (Shake-XR) |
| Amplitude | 25 mm (Shake-LR), 20 mm (Shake-XR) |
| Temperature Operating Range | 0°C to +50°C |
| Platform Configuration | Single or dual platforms |
| Platform Dimensions | 300 × 200 mm |
| Max Load Capacity | ~2 kg (including platform and fixtures) |
| Display | Optional digital speed display |
| Power Supply | AC 100 V, 0.5 A |
| Dimensions (LR) | 300 × 270 × 152 mm |
| Dimensions (XR) | 300 × 235 × 155 mm |
| Weight | 7.8 kg (LR), 7.7 kg (XR) |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Distributor Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | Shaker (LR, XR, Mix-VR, EVR, Wave-PR, SI, SI Slim, E-36, PR-12, NR-1 to NR-5100, SR-1/2DS/2DW, TS-10/20, SR-10, VIX-100) |
| Timing Range | 0–99 h 59 min |
| Oscillation Frequency | 5–2500 rpm |
| Oscillation Amplitude | 10–70 mm |
| Temperature Control | None |
| Platform Configuration | Single or dual-layer flat platforms |
| Key | Brand: TAITEC |
|---|---|
| Origin | Japan |
| Model | Shaker-LR |
| Oscillation Mode | Reciprocal / Rotary (switchable) |
| Speed Range | 20–160 rpm |
| Amplitude | 25 mm |
| Platform Dimensions | 300 × 200 mm |
| Operating Temperature Range | 0–50 °C |
| Max Load Capacity | ~2 kg (excl. platform & fixtures) |
| Power Supply | AC 100 V, 0.5 A |
| Weight | ~7.8 kg |
| Dimensions (W×D×H) | 300 × 270 × 152 mm |
| Key | Brand: TAITEC |
|---|---|
| Origin | Japan |
| Model(s) | SM-05N, SJ-07N, SP-12N |
| Temperature Range | RT+5°C to +85°C (SM-05N), RT+5°C to +95°C (SJ-07N), RT+5°C to +100°C (SP-12N) |
| Temperature Stability | ±0.1°C |
| Control Method | PID with Thermistor Sensor |
| Circulation Type | Internal Recirculation Only |
| Heating Power | 500 W (SM-05N), 700 W (SJ-07N), 1200 W (SP-12N) |
| Bath Volume Capacity | Not Specified (Compatible with Optional Polyethylene C-type Bath: 6 L nominal) |
| Stirring Mechanism | Adjustable Jet Flow |
| Timer Functions | Set-Time Alert Timer (1 min–99 h 59 min), Auto-Off Timer (1 min–99 h 59 min) |
| Safety Features | Dry-run Prevention Float Switch, Over-Temperature & Low-Water Alarms, Sensor Fault Detection, Non-Volatile Memory Error Logging, Heater Guard Enclosure, Circuit Protection (8 A / 10 A / 15 A), Fuse (2 A) |
| Power Supply | AC 100 V, 50/60 Hz |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | SP-12R |
| Instrument Type | Circulating Constant-Temperature Bath |
| Circulation Mode | Internal Circulation |
| Temperature Control | Refrigeration & Heating Capable |
| Bath Volume | 1.7 L |
| Temperature Range | 0–100 °C |
| Temperature Stability | ±0.1 °C |
| Heating Power | 1.2 kW |
| Display Resolution | 0.1 °C |
| Dimensions (Bath Cavity) | 130 × 85 × 145 mm (W × D × H) |
| Unit Dimensions | 130 × 164 × 315 mm (W × D × H) |
| Weight | ~5 kg |
| Power Supply | AC 100 V, 13 A |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | SR-1 |
| Oscillation Mode | Reciprocating |
| Speed Range | 50–250 rpm |
| Amplitude | 50 mm (fixed, optional 35 mm) |
| Timer Range | 60 min |
| Platform Options | 4 interchangeable platforms (A, B, C, E) |
| Max Load Capacity | ~7 kg (including platform) |
| Display | Digital speed readout |
| Power Supply | AC 100 V, 1 A |
| Dimensions | 570 × 435 × 247 mm (W × D × H) |
| Weight | ~45 kg |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | SR-10 |
| Oscillation Mode | Horizontal reciprocating |
| Speed Range | 50–250 rpm |
| Amplitude | 45 mm (fixed) |
| Timer Range | 1 min – 99 h 59 min |
| Platform Capacity | 1–3 stackable decks |
| Max Load per Deck | ~10 kg (excluding deck weight) |
| Dimensions (3-deck) | 740 × 438 × 435 mm (H) |
| Weight | ~70 kg |
| Power Supply | AC 100 V, 1 A |
| Standard Platform | C-type for 32 × 50 mL centrifuge tubes |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | SR-2ES |
| Timer Range | 1 min – 99 h 59 min |
| Oscillation Frequency | 50–300 rpm |
| Oscillation Amplitude | 40 mm |
| Capacity | Up to 192 tubes |
| Load Capacity | ~7.5 kg |
| Noise Level | ≤45 dB(A) |
| Power Supply | AC 220 V, 0.5 A |
| Dimensions (W×D×H) | 410 × 585 × 500 mm |
| Weight | ~49 kg |
| Oscillation Mode | Reciprocating (vertical/horizontal switchable) |
| Display | Digital speed & timer readout |
| Timing Modes | Continuous, Interval, Delay-start |
| Brand | TAITEC |
|---|---|
| Origin | China (Beijing) |
| Manufacturer Status | Authorized Distributor |
| Product Type | Separatory Funnel Shaker |
| Model | SR-2EW / SR-2ES / SR-2DW / SR-2DS |
| Timing Range | 1 min – 99 h 59 min |
| Oscillation Frequency | 50–300 rpm |
| Oscillation Amplitude | 40 mm |
| Number of Funnel Positions | 10 (dual-side configuration) |
| Noise Level | ≤45 dB(A) |
| Load Capacity per Side | 7.5 kg (including platform) |
| Dimensions (SR-2ES) | 410 × 585 × 500 mm |
| Dimensions (SR-2EW) | 410 × 760 × 500 mm |
| Weight (SR-2ES) | 49 kg |
| Weight (SR-2EW) | 57 kg |
| Power Supply | AC 220 V, 0.5 A |
| Brand | Taitec |
|---|---|
| Origin | Japan |
| Model | SX-10N, SH-10N |
| Temperature Range | RT+5°C to +105°C (SX-10N), RT+5°C to +180°C (SH-10N) |
| Temperature Stability | ±0.05°C (SX-10N), ±0.1°C (SH-10N) |
| Control Type | Heating-Only, Platinum Pt100 PID Controller |
| Circulation | Internal Jet-Type Flow |
| Stirring Adjustment | Continuously Variable Flow Knob |
| Timer Functions | Set-Time Alert Timer (1 min–99 h 59 min), OFF Timer (1 min–99 h 59 min), Temperature-Transition Timer |
| Temperature Memory | 1 Preset Slot |
| Safety Features | Dry-run Prevention (Float-Type for SX-10N, Flow-Sensing for SH-10N), Over-Temp/Under-Temp Alarm, Low-Level Detection, Sensor Fault Detection, Non-Volatile Memory Error Monitoring, Heater Guard, Circuit Protection (10A/15A), Dual Fuses (2A) |
| Power Supply | AC100V, 50/60Hz, 5.5A (SX-10N), 11A (SH-10N) |
| Weight | 3.4 kg (SX-10N), 5.0 kg (SH-10N) |
| Compliance | RoHS Directive |
| Brand | Taitec |
|---|---|
| Origin | Japan |
| Model | TC-8F / TC-8G |
| Instrument Type | Automated Quantitative Vacuum Concentrator |
| Temperature Range | Ambient to +60 °C |
| Temperature Control Accuracy | ±0.2–0.3 °C |
| Sample Capacity | 8 × 50 mL tubes (TC-8F requires full 8-tube loading |
| Heating Power | 150 W |
| Vacuum Requirement | Compatible with Q-1 water aspirator pump (6–7 L/min, ultimate vacuum 3.2–38.7 kPa depending on solvent and coolant temperature) |
| Dimensions (TC-8F) | 190 × 285 × 355 mm (W×D×H) |
| (TC-8G) | 230 × 285 × 355 mm |
| Weight | ~10.5 kg |
| Power Supply | AC 220 V, 1 A |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | TS-10 |
| Oscillation Mode | Reciprocating |
| Speed Range | 50–250 rpm |
| Amplitude | 45 mm (fixed) |
| Max Load Capacity | 10 kg (excluding platform) |
| Timer Function | Dual-stage timer (start time + runtime |
| Platform Compatibility | Interchangeable platforms for PE bottles, test tubes, flasks, vials, and mesh supports |
| Power Consumption | 70 W |
| Dimensions | 740 × 439 × 459 mm (H) |
| Weight | ~70 kg |
| Voltage | AC 100 V |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | TS-20 |
| Oscillation Mode | Reciprocating |
| Speed Range | 25–200 rpm |
| Amplitude | 10–50 mm (continuously adjustable) |
| Max Load Capacity | ~20 kg (excluding platform and clamping rods) |
| Timer Function | Dual independent timers (start time + runtime), up to 300 h total |
| Platform Configuration | Multi-plate compatible |
| Power Supply | AC 100 V, 1 A |
| Power Consumption | 70 W/h |
| Dimensions | 820 × 601 × 591 mm (H) |
| Weight | ~100 kg |
| Standard Accessories | Long clamping rods (×4), short clamping rods (×4), timer adjustment wrench |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | uT-48 |
| Instrument Type | Cryogenic Ball Mill |
| Sample Compatibility | Frozen biological and hard materials (tissues, bone, teeth, polymers, rubber, asbestos) |
| Output Particle Size | < 0.01 mm |
| Oscillation Mode | Vertical reciprocating |
| Speed Range | 0–2500 rpm |
| Capacity | Up to 48 × 2.0 mL microcentrifuge tubes or 4 × stainless-steel heavy-duty vessels |
| Sample Load per Tube | 100–200 mg (microtubes), 1–2 g (stainless-steel vessels) |
| Timer | 1–999 s (digital display) |
| Temperature Monitoring | −196 °C to +50 °C (measured at tube holder base) |
| Safety Features | Lid interlock, rack mounting confirmation switch |
| Dimensions | 220 × 310 × 315 mm (W × D × H) |
| Weight | ~10 kg |
| Power Supply | AC 100 V |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | V·BR-36 |
| Instrument Type | Air-jacketed incubated orbital shaker |
| Timer Range | 60 min |
| Oscillation Speed | 50–500 rpm |
| Amplitude | 20 mm |
| Temperature Range | Ambient + 5°C to +60°C |
| Number of Platforms | 1 |
| Platform Dimensions | 240 × 200 mm |
| Internal Height | 165 mm |
| Max Load Capacity | 1 kg (including platform) |
| Heating Power | 80 W |
| Temp. Control Accuracy | ±0.3–1.0°C (at 25°C ambient) |
| Safety Features | Overheat protection, circuit breaker, lid-activated brake, sensor diagnostics |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | VA-120 |
| Cooling Temperature | −35 °C (at 27 °C ambient) |
| Condensate Capacity | ~30 mL per cycle (with TB-115 trap bottle) |
| Cooling Method | Multi-stage thermoelectric (Peltier) module |
| Cold Trap Chamber Dimensions | Φ50 × 100 mm (~200 mL volume) |
| Power Supply | AC 100 V, 3 A |
| Dimensions (W × D × H) | 244 × 330 × 285 mm |
| Weight | ~12 kg |
| Safety Features | Overcurrent fuse, thermal cut-off fuse |
| Additional Outlets | Two 3-pin sockets (5 A total) |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | VA-140S |
| Instrument Type | Benchtop Cryo-Cold Trap |
| Application | Laboratory-Scale Condensation & Solvent Capture |
| Cooling Temperature | –65 °C (at no load, 20 °C ambient, 500 mL methanol) |
| Operating Temperature Range | –10 °C to –55 °C (temperature control accuracy ±2.0 °C) |
| Condensate Capacity | ~300 mL per cycle (with GC-025 glass condenser) |
| Cooling Bath Volume | ~960 mL (Φ120 × 80 mm) |
| Stirring Function | Integrated magnetic stirrer |
| Refrigeration System | 40 W Stirling-cycle helium cooler (zero ODP, zero GWP) |
| Power Supply | AC 100 V, 1 A (up to 7 A with auxiliary socket) |
| Dimensions | 233 × 330 × 392 mm (W × D × H) |
| Weight | ~10 kg |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | VA-140S Freeze Dryer System |
| Instrument Type | Manifold Freeze Dryer |
| Application Scope | Laboratory Use |
| Shelf Area Equivalent | 1 L |
| Ultimate Vacuum | < 50 Pa |
| Condensate Capacity | 120 mL per cycle |
| Cold Trap Temperature | −60 °C |
| Dimensions (W×D×H) | 255 × 351 × 740 mm |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | VA-250F / VA-500R / VA-800R |
| Cooling Temperature Range | –45°C to –75°C |
| Condensate Capacity (per cycle) | ~200 mL (VA-250F) to ~1000 mL (VA-500R/800R) |
| Cooling Method | Direct-immersion refrigerated bath with internal condenser coil |
| Power Supply | AC 100 V, 5–13 A |
| Weight | 35–82 kg |
| Compliance | Designed for GLP-compliant laboratory environments |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | VC-15S |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | +55 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Capacity | 100 mL |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | VC-15S/SP |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Up to +55 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Rotational Speed | Fixed at ~2000 rpm |
| Vacuum Performance | Built-in diaphragm pump (VC-15SP): ~−80 kPa, ~4 L/min |
| Vacuum Gauge | 0 to −100 kPa (Bourdon tube) |
| Chamber Material | SUS304 stainless steel with PTFE coating |
| Lid Material | Tempered glass |
| Timer | 60-minute analog timer (extendable manually) |
| Safety Features | Overheat protection, thermal fuse, lid-open braking (simultaneous halt of heating and rotation) |
| Dimensions | 171 × 236 × 175 mm (W × D × H) |
| Weight | ~3 kg |
| Power Supply | AC 100 V, 1 A |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | VC-36R / VC-96R |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | +4°C to +70°C |
| Temperature Control Accuracy | ±0.1°C |
| Sample Capacity | 2.0 mL × 96 (VC-96R) |
| Rotational Speed | 300–2000 rpm (max 440 × g with 36A rotor) |
| Vacuum Range | 0 to –0.1 MPa |
| Timer | 1 min to 99 h 59 min (digital) |
| Chamber Material | SUS304 stainless steel with PTFE coating |
| Lid Material | PVC |
| Vacuum & Vent Nozzle Diameters | Exhaust Φ14 mm, Vent Φ6 mm, Cooling Water Φ12 mm |
| Safety Features | Overcurrent protection, automatic shutdown upon lid opening (heater/rotor/vacuum pump), real-time thermal and motor diagnostics with non-volatile memory logging |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | VC-96W |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Room Temperature +5°C to +65°C |
| Temperature Control Accuracy | ±0.1°C |
| Maximum Sample Capacity | 200 mL |
| Rotational Speed | 100–2600 rpm (up to 800 × g with 96S swing rotor) |
| Timer Range | 1–99 min |
| Chamber Material | SUS316 stainless steel with PTFE coating |
| Lid Material | PVC |
| Vacuum Gauge | 0 to –0.1 MPa (Bourdon tube) |
| Vacuum Release | Manual |
| Heating Method | Far-infrared heater |
| Safety Features | Lid interlock power cutoff, independent overheat protection sensor, motor circuit breaker, real-time anomaly display (power failure, rotation error, lid open) |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | VD-250R |
| Instrument Type | Manifold Freeze Dryer |
| Application | Laboratory-Scale Lyophilization |
| Shelf Area | 11.7 L (chamber volume) |
| Ultimate Vacuum | <50 Pa |
| Condensate Capacity | 2000 mL per 24 h |
| Cold Trap Temperature | ≤ −75 °C |
| Dimensions (W×D×H) | 490 × 600 × 805 mm |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | VIX-100 |
| Timer Range | 15 min |
| Oscillation Speed | up to 2000 rpm |
| Platform Configuration | Single or Dual Shaking Plates |
| Operating Temperature | Ambient |
| Applicable Vessels | 20 mL glass vials (100 units), capped tubes up to 180 mm in length |
| Platform Dimensions | 325 × 325 mm |
| Power Supply | AC 100 V, 2 A |
| Weight | ~32 kg |
| Compliance | Designed for GLP-compliant sample preparation workflows |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | VP-050N / VP-300N |
| Output Power | 50 W (VP-050N), 300 W (VP-300N) |
| Frequency Range | 19.5–20.5 kHz (VP-050N), 19–21 kHz (VP-300N) |
| Transducer Interface | Integrated horn-type piezoelectric converter with auto-tuning |
| Control | Digital LCD interface with real-time % output, current, temperature (*optional sensor), timer (1 s–120 min), and pulse mode (ON/OFF: 0.1–60 s) |
| Probe Options | Φ2 mm, Φ3 mm, Φ6 mm stepped microprobes (VP-050N) |
| Dimensions (W×D×H) | 122×288×283 mm (VP-050N), 143×360×283 mm (VP-300N) |
| Weight | 4.5 kg (VP-050N), 6.7 kg (VP-300N) |
| Power Supply | AC 100 V, 1 A (VP-050N), AC 100 V, 5 A (VP-300N) |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | Wave-PR / Wave-SI / Wave-SI Slim |
| Oscillation Frequency | 5–50 rpm (Wave-PR), 10–60 rpm (Wave-SI & Wave-SI Slim) |
| Oscillation Angle | 2°–6° (adjustable, Wave-PR), 2°–10° (adjustable, Wave-SI), 6° (fixed, Wave-SI Slim) |
| Operating Temperature Range | 0 °C to +50 °C |
| Platform Quantity | 1 |
| Platform Dimensions | 300 × 200 mm (Wave-PR), 180 × 120 mm (Wave-SI), 180 × 130 mm (Wave-SI Slim) |
| Max Load Capacity | ~2 kg (excluding platform and fixtures) |
| Power Supply | AC 100 V, 0.5 A |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | XY-80 |
| Instrument Type | Temperature-Controlled Oscillating Water Bath |
| Circulation | Internal Recirculation |
| Temperature Control | Heating-Only |
| Bath Volume | 10 L |
| Temperature Range | RT + 5 °C to 80 °C |
| Temperature Stability | ±0.02–0.1 °C |
| Oscillation Modes | Reciprocating, Orbital, Figure-Eight |
| Amplitude | 30 mm |
| Speed Range | 20–160 rpm (closed-loop feedback control) |
| Platform Dimensions | 400 × 300 mm |
| External Dimensions (W×D×H) | 900 × 520 × 470 mm |
| Weight | 76 kg |
| Power Supply | AC 100 V, 15 A |
| Heating Power | 1.3 kW |
| Safety Features | Overtemperature Cut-off, Dry-Run Protection, Sensor Fault Detection, Dual-Temperature Display (Set vs. Actual) |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | μT-01 |
| Disruption Principle | Horizontal umbrella-shaped oscillation |
| Speed Range | 2,500–4,600 rpm (6 preset steps) |
| Sample Volume | 2 mL |
| Sample Capacity | 1 tube per run |
| Compatible Beads | Glass, zirconia, stainless steel beads (φ0.15–6 mm), metal mortars |
| Operating Temperature | +5 to +35 °C |
| Vibration Frequency | 40–78 Hz |
| Timer Range | 5–60 s (6 presets) |
| Safety Features | Lid interlock stop, overload current protection |
| Dimensions | 172 × 280 × 160 mm (W × D × H) |
| Weight | ~5 kg |
| Power Supply | AC 100 V, 0.5 A |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | μT-12 |
| Instrument Type | Bead Mill Cell Disruptor |
| Operating Frequency | 53 Hz |
| Sample Capacity | 12 × 5.0 mL tubes |
| Throughput | 12 samples per run |
| Speed Range | 1,800–3,200 rpm (8-step digital adjustment) |
| Timer | 1–300 s (1-s increment, memory for 2 speed/time presets) |
| Safety Features | Lid-interlock shutdown, overload current protection |
| Dimensions | 310 × 400 × 200 mm (W × D × H) |
| Weight | ~15 kg |
| Power Supply | AC 100 V, 4 A |
| Ambient Operating Range | +5 °C to +35 °C |
| Tube Compatibility | Standard threaded 1.5/2.0 mL and 5.0 mL microtubes (e.g., Watson 1392-200, 2332-105) |
| Bead Compatibility | Stainless steel (SUS), zirconia, glass beads |