testo
Filter
Showing 121–150 of 184 results
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 735-1 |
| Input Channels | 1 × Pt100 + 2 × Thermocouple (Type K, J, T, N, S, R, B, E, L, U) |
| System Accuracy (with optional high-precision Pt100 probe) | ±0.05 °C |
| Resolution | 0.001 °C |
| Display | Dual-line LCD with simultaneous 3-channel readout |
| Alarm | Audible limit alarm |
| Data Logging | Internal storage for min/max/avg/ΔT |
| Print Output | Optional infrared printer interface with programmable cycle (1 min – 24 h) |
| Protection Rating | IP65 |
| Calibration | Full-scale system adjustment capability |
| Compliance | Designed to support GLP/GMP traceability workflows |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0590 7450 |
| AC Voltage Range | 12–1000 V |
| Operating Temperature | −10 to +50 °C |
| Storage Temperature | −15 to +60 °C |
| Relative Humidity | 0–80 % RH (non-condensing) |
| Weight | 63 g |
| Dimensions | 155 × 25 × 23 mm |
| Protection Rating | IP67 |
| Safety Category | CAT IV 600 V / CAT III 1000 V |
| Compliance | EN 61010-1, EN 61326-1 |
| Power Supply | 2 × AAA batteries |
| Integrated LED Illumination | Yes |
| Alarm Type | Visual (dual-color LED) + Audible (buzzer) |
| Sensitivity Modes | 2-level (Phase Detection / Voltage Presence Confirmation) |
| High-Frequency Interference Rejection | Built-in filter circuit |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0590 7450 |
| AC Voltage Range | 12–1000 V |
| Operating Temperature | −10 to +50 °C |
| Storage Temperature | −15 to +60 °C |
| Relative Humidity | 0–80 % RH |
| Weight | 63 g |
| Dimensions | 155 × 25 × 23 mm |
| Protection Rating | IP67 |
| Safety Category | CAT IV 600 V / CAT III 1000 V |
| Compliance | EN 61010-1, EN 61326-1 |
| Battery | 2 × AAA |
| Integrated LED Illumination | Yes |
| Alarm Type | Visual (LED) and Audible |
| Sensitivity Levels | 2-stage (Phase Detection / Voltage Presence Indication) |
| Interference Rejection | Built-in High-Frequency Noise Filter |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0590 7601 |
| Type | True RMS Digital Multimeter |
| Safety Rating | CAT III 600 V / CAT IV 300 V |
| Display | 6000-count LCD with backlight |
| Auto Power Off (APO) | Yes |
| Low-Pass Filter (LPF) | Yes |
| Measurement Functions | AC/DC Voltage, AC/DC Current, Resistance, Continuity, Diode Test, Capacitance, Frequency, Duty Cycle, Temperature (via optional probe) |
| Compliance | IEC/EN 61010-1, IEC/EN 61326-1 (EMC) |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0590 7701 |
| Measurement Type | True RMS AC/DC Clamp Multimeter |
| Voltage Range | 600 V AC/DC |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | testo 810 |
| Type | Portable Infrared Thermometer |
| Infrared Temperature Range | -30 to +300 °C |
| Air Temperature Range (NTC) | -10 to +50 °C |
| IR Accuracy | ±2.0 °C (-30 to +100 °C), ±2 % of reading (remaining range) |
| NTC Accuracy | ±0.5 °C |
| Optical Resolution | 6:1 |
| Emissivity Adjustment | 0.10–1.00 (adjustable in 0.01 steps) |
| Display | Backlit LCD with ΔT calculation |
| Laser Targeting | Single-point |
| IP Rating | IP40 |
| Weight | 90 g (incl. batteries and protective sleeve) |
| Dimensions | 119 × 46 × 25 mm (with sleeve) |
| Operating Temperature | -10 to +50 °C |
| Battery | 2 × AAA, ~50 h life (backlight off) |
| Response Time | 0.5 s (both channels) |
| Resolution | 0.1 °C (both IR and NTC) |
| Data Functions | Max/Min/Hold |
| Brand | testo |
|---|---|
| Model | testo 816-1 |
| Compliance | IEC 61672-1 Class 2, ANSI S1.4 Type 2, JJG 188, GB/T 3785.2–2010 |
| Measurement Range | 30–130 dB |
| Frequency Range | 20 Hz–8 kHz |
| Accuracy | ±1.4 dB (at 94 dB, 1 kHz) |
| Resolution | 0.1 dB |
| Time Weighting | FAST (125 ms), SLOW (1 s) |
| Frequency Weighting | A, C |
| Dynamic Range | 100 dB |
| Microphone | 0.5-inch electret condenser |
| Display | Backlit HD LCD with bar graph, time stamp, and data logging indicators |
| Data Storage | 99 manual entries, 31,000 continuous records, up to 99,999 via PC software |
| Power | 4 × AA batteries |
| Operating Temperature | 0–+40 °C |
| Storage Temperature | −10–+60 °C |
| Dimensions | 272 × 83 × 42 mm |
| Weight | 390 g |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | testo 826-T2 |
| Type | Portable Infrared Thermometer |
| Optical Resolution | 6:1 |
| Temperature Range | -50 to +300 °C |
| Accuracy | ±1.5 °C (-20 to +100 °C), ±2 °C or ±2 % of reading (remaining range) |
| Measurement Speed | 0.5 s per reading |
| Resolution | 0.1 °C |
| Display | Single-line LCD |
| Weight | 80 g |
| Dimensions | 148 × 34.4 × 19 mm |
| Operating Temperature | -20 to +50 °C |
| Storage Temperature | -40 to +70 °C |
| Power Supply | 2 × AAA batteries |
| Battery Life | Approx. 20 h |
| IP Rating | IP67 (with protective sleeve) |
| Compliance | EN 13485 |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | testo 826-T4 |
| Instrument Type | Portable |
| Optical Resolution | 6:1 |
| Laser Targeting | Single-point |
| IR Temperature Range | −50 to +300 °C |
| IR Accuracy | ±1.5 °C (−20 to +100 °C), ±2 °C or ±2 % of reading (remaining range) |
| NTC Probe Range | −50 to +230 °C |
| NTC Accuracy | ±0.5 °C (−20 to +99.9 °C), ±1 °C or ±1 % of reading (remaining range) |
| IR Measurement Speed | 0.5 s |
| NTC Measurement Speed | 1.25 s |
| Resolution | 0.1 °C (both modes) |
| Display | Single-line LCD |
| IP Rating | IP67 (with protective sleeve) |
| Weight | 80 g |
| Dimensions | 148 × 34.4 × 19 mm |
| Operating Temperature | −20 to +50 °C |
| Storage Temperature | −40 to +70 °C |
| Power Supply | 2 × AAA batteries |
| Battery Life | Approx. 20 h |
| Compliance | EN 13485, HACCP-ready |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 826-T4 |
| Type | Portable Dual-Mode Thermometer |
| Infrared Temperature Range | −50 to +300 °C |
| NTC Probe Temperature Range | −50 to +230 °C |
| IR Accuracy | ±1.5 °C (−20 to +100 °C), ±2 °C or ±2 % of reading (remaining range) |
| NTC Accuracy | ±0.5 °C (−20 to +99.9 °C), ±1 °C or ±1 % of reading (remaining range) |
| IR Resolution | 0.1 °C |
| NTC Resolution | 0.1 °C |
| IR Measurement Time | 0.5 s |
| NTC Measurement Time | 1.25 s |
| Optical Resolution | 6:1 |
| Laser Targeting | Single-point |
| IP Rating | IP67 (with protective sleeve) |
| Dimensions | 148 × 34.4 × 19 mm |
| Weight | 80 g |
| Operating Temperature | −20 to +50 °C |
| Storage Temperature | −40 to +70 °C |
| Power Supply | 2 × AAA batteries |
| Battery Life | Approx. 20 h |
| Display | Monochrome LCD, single-line |
| Compliance | EN 13485, HACCP-aligned |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | testo 830-S1 |
| Type | Portable Infrared Thermometer |
| Housing Material | Anodized Aluminum |
| Laser Targeting | Single-Point |
| Alarm Function | Adjustable Upper/Lower Limit with Audible Alert |
| Measurement Principle | Non-Contact Infrared Pyrometry (8–14 µm Spectral Range) |
| Emissivity Adjustment | Fixed at 0.95 (optimized for common industrial surfaces) |
| Distance-to-Spot Ratio | 12:1 |
| Operating Temperature Range | 0 to 50 °C |
| Storage Temperature Range | -20 to 70 °C |
| Relative Humidity Limit | ≤95 % RH (non-condensing) |
| Power Supply | 2 × AAA batteries |
| Battery Life | Approx. 10 hours continuous use |
| Display | Backlit LCD with hold function |
| Compliance | CE, RoHS, ISO/IEC 17025 traceable calibration options available |
| Brand | testo |
|---|---|
| Model | 830-T1 |
| Type | Portable Infrared Thermometer |
| Temperature Range | -30 to +400 °C |
| Accuracy | ±1.5 °C or ±1.5 % of reading (0.1 to +400 °C) |
| Optical Resolution | 10:1 |
| Response Time | 0.5 s |
| Resolution | 0.1 °C |
| Emissivity Adjustment | 0.10–1.00 (adjustable in 0.01 steps) |
| Measurement Frequency | 2 Hz |
| Display | Backlit LCD with Max/Min/Hold functions |
| Alarm | Dual user-defined limit thresholds with audible and visual alert |
| Weight | 200 g |
| Dimensions | 190 × 75 × 38 mm |
| Operating Temperature | -20 to +50 °C |
| Storage Temperature | -40 to +70 °C |
| Housing Material | ABS |
| Power Supply | 9 V alkaline battery |
| Battery Life | Approx. 15 hours |
| Brand | testo |
|---|---|
| Model | 830-T1 |
| Type | Portable Infrared Thermometer |
| Measuring Range | -30 to +400 °C |
| Accuracy | ±2 °C or ±2 % of reading (-30 to 0 °C), ±1.5 °C or ±1.5 % of reading (0.1 to +400 °C) |
| Optical Resolution | 10:1 |
| Response Time | 0.5 s |
| Temperature Resolution | 0.1 °C |
| Measurement Frequency | 2 Hz |
| Emissivity Adjustment | 0.10–1.00 (adjustable in 0.01 steps) |
| Display | Backlit LCD |
| Operating Temperature | -20 to +50 °C |
| Storage Temperature | -40 to +70 °C |
| Weight | 200 g |
| Dimensions | 190 × 75 × 38 mm |
| Power Supply | 9 V alkaline battery |
| Battery Life | Up to 15 hours |
| Housing Material | ABS |
| Brand | testo |
|---|---|
| Model | 830-T1 |
| Type | Single-point laser infrared thermometer |
| Distance-to-Spot Ratio | 10:1 |
| Temperature Range | -30 to +400 °C |
| Resolution | 0.5 °C |
| Accuracy | ±1.5 °C or ±1.5% of reading (for +0.1 to +400 °C), ±2 °C (for -30 to 0 °C) |
| Emissivity Adjustment | 0.2–1.0 (adjustable) |
| Dimensions | 190 × 75 × 38 mm |
| Weight | 200 g |
| Power Supply | 9 V alkaline battery (IEC 6LR61) |
| Brand | testo |
|---|---|
| Model | 830-T2 |
| Type | Portable Infrared Thermometer |
| Optical Resolution | 12:1 |
| Laser Targeting | Dual-point |
| Emissivity Adjustment | Yes |
| Temperature Range (IR) | –30 °C to +400 °C |
| Temperature Range (Contact Probe) | –50 °C to +500 °C |
| IR Accuracy | ±1.5 °C or ±1.5 % of reading (whichever is greater) from 0.1 °C to 400 °C |
| Contact Probe Accuracy | ±0.5 °C + 0.5 % of reading |
| IR Resolution | 0.1 °C |
| Contact Resolution | 0.1 °C |
| IR Response Time | 0.5 s |
| Contact Response Time | 1.75 s |
| Probe Type | K-type (NiCr–Ni) thermocouple |
| Display | Backlit LCD |
| Alarm Function | Dual user-defined high/low limits with audible and visual alert |
| Data Hold & Min/Max Tracking | Yes |
| Housing Material | ABS |
| Weight | 200 g |
| Dimensions | 190 × 75 × 38 mm |
| Operating Temperature | –20 °C to +50 °C |
| Storage Temperature | –40 °C to +70 °C |
| Power Supply | 9 V battery (included) |
| Battery Life | ~15 hours |
| Brand | testo |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | testo 830-T4 |
| Instrument Type | Portable |
| Distance-to-Spot Ratio | 30:1 |
| Emissivity Adjustment | Adjustable (0.10–1.00) |
| Laser Aiming | Dual-point |
| Measurement Frequency | 2 Hz |
| IR Temperature Range | –30 to +400 °C |
| IR Accuracy | ±1.5 °C (–20 to 0 °C), ±2 °C (–30 to –20.1 °C), ±1 °C or ±1 % of reading (remaining range) |
| IR Resolution | 0.1 °C |
| Response Time (IR) | 0.5 s |
| Contact Probe Input | Type K thermocouple (–50 to +500 °C, ±0.5 °C + 0.5 %, resolution 0.1 °C, response time 1.75 s) |
| Display | Backlit LCD |
| Operating Temperature | –20 to +50 °C |
| Storage Temperature | –40 to +70 °C |
| Weight | 200 g |
| Dimensions | 190 × 75 × 38 mm |
| Power Supply | 9 V alkaline battery |
| Battery Life | ~15 h |
| Brand | testo |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 0563 8314 |
| Instrument Type | Portable |
| Distance-to-Spot Ratio | 30:1 |
| IR Temperature Range | -30 to +400 °C |
| IR Accuracy | ±1.5 °C (-20 to 0 °C), ±2 °C (-30 to -20.1 °C), ±1 °C or ±1 % of reading (remaining range) |
| IR Resolution | 0.1 °C |
| IR Response Time | 0.5 s |
| Contact Probe Type | Spring-loaded surface probe (Type K thermocouple, 0602 0393) |
| Contact Range | -50 to +500 °C |
| Contact Accuracy | ±0.5 °C + 0.5 % of reading |
| Contact Resolution | 0.1 °C |
| Contact Response Time | 1.75 s |
| Display | Backlit LCD |
| Laser Aiming | Dual-point |
| Emissivity Adjustment | Adjustable (0.10–1.00) |
| Alarm Function | Two user-defined limits with audible/visual alert |
| Data Hold & Min/Max Tracking | Yes |
| Operating Temperature | -20 to +50 °C |
| Storage Temperature | -40 to +70 °C |
| Dimensions | 190 × 75 × 38 mm |
| Weight | 200 g |
| Power Supply | 9 V battery |
| Battery Life | ~15 h |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 8351 |
| Type | Portable Infrared Thermometer |
| IR Temperature Range | –30 to +600 °C |
| IR Accuracy | ±2.5 °C (–30.0 to –20.1 °C), ±1.5 °C (–20.0 to –0.1 °C), ±1.0 °C (0.0 to +99.9 °C), ±1 % of reading (remaining range) |
| Optical Resolution | 50:1 |
| Emissivity Adjustment | 0.10–1.00 (20 preset values stored) |
| Contact Temperature Input | Type K thermocouple (–50 to +600 °C, ±0.5 °C + 0.5 % of reading) |
| Display | Backlit dot-matrix LCD |
| Data Storage | 200 measurement values |
| Interface | USB for PC connectivity |
| Power | 3 × AA batteries (25 h typical runtime, laser & backlight off) |
| Weight | 514 g |
| Dimensions | 193 × 166 × 63 mm |
| Operating Temperature | –20 to +50 °C |
| Storage Temperature | –30 to +50 °C |
| Compliance | EN 61326-1:2006 (EMC), CE-marked |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 8352 |
| Type | Portable Infrared Thermometer |
| IR Temperature Range | –10 to +1500 °C |
| IR Accuracy | ±2.0 °C or ±1 % of reading |
| Optical Resolution | 50:1 |
| Laser Aiming | 4-point visible laser |
| Emissivity Table | 20 pre-stored values |
| Data Storage | 200 measurements |
| Contact Probe Input | Type K thermocouple (–50 to +1000 °C) |
| Display | Backlit dot-matrix LCD |
| Weight | 514 g |
| Dimensions | 193 × 166 × 63 mm |
| Operating Temperature | –20 to +50 °C |
| Battery | 3 × AA (25 h typical, no backlight/laser) |
| Compliance | EN 61326-1:2006 |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | testo 865 |
| Price | Upon Request |
| Spectral Response | Mid-Wave Infrared (MWIR) |
| Detector Type | Scanning Focal Plane Array (FPA) |
| Application | Temperature Measurement |
| Measurement Method | Non-Contact |
| Detector Cooling | Uncooled |
| Frame Rate | 9 Hz @ 160 × 120 |
| Accuracy | ±2 °C or ±2% of reading (whichever is greater) |
| Temperature Range | −20 °C to +280 °C |
| Infrared Resolution | 160 × 120 pixels |
| Spectral Band | 7.5–14 µm |
| Thermal Sensitivity (NETD) | < 0.12 °C |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 865 |
| Detector Type | Scanning Focal Plane Array |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 160 × 120 pixels |
| Enhanced Resolution (via IR SuperResolution) | 320 × 240 pixels |
| Thermal Sensitivity (NETD) | < 0.12 °C |
| Temperature Range | –20 to +280 °C |
| Accuracy | ±2 °C or ±2% of reading |
| Measurement Method | Non-contact infrared radiometry |
| Frame Rate | 9 Hz @ 160 × 120 |
| Operating Mode | Uncooled microbolometer |
| Wavelength Band | Mid-wave infrared (MWIR) |
| Total Measurement Points | 19,200 per frame |
| Image Export Format | JPEG |
| Software Included | testo IRSoft |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 8650 |
| Detector Type | Uncooled Microbolometer FPA (Scanning-type not applicable — corrected per technical reality) |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 160 × 120 pixels |
| SuperResolution (testo Ultra-Pixel) | 320 × 240 pixels |
| Thermal Sensitivity (NETD) | ≤0.12 °C |
| Frame Rate | 9 Hz |
| Temperature Range | −20 °C to +280 °C |
| Accuracy | ±2 °C or ±2 % of reading (whichever is greater) |
| IFOV | 3.4 mrad |
| Spatial Resolution (Ultra-Pixel mode) | 2.1 mrad |
| Field of View | 31° × 23° |
| Minimum Focus Distance | <0.5 m |
| Display | 3.5″ LCD, 320 × 240 px |
| Storage | 2.8 GB internal memory |
| Image Formats | .bmt, .jpg, .bmp, .png, .xls, .csv |
| Video Output | USB 2.0 Micro-B streaming |
| Operating Temp. | −15 °C to +50 °C |
| Storage Temp. | −30 °C to +60 °C |
| Humidity | 20–80 % RH (non-condensing) |
| IP Rating | IP54 |
| Dimensions | 219 × 96 × 95 mm |
| Weight | 510 g |
| Battery Life | ~4 h (Li-ion, rechargeable) |
| Power Supply | AC adapter included |
| Emission Adjustment | 0.01–1.00 (user-selectable) |
| Software | testo IRSoft (Windows 10/8/7, free download) |
| Compliance | EMC Directive 2014/30/EU, RoHS, CE |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 8650 |
| Detector Type | Uncooled Microbolometer |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 160 × 120 pixels (enhanced to 320 × 240 via testo SuperResolution) |
| Thermal Sensitivity (NETD) | ≤0.12 °C |
| Temperature Range | −20 to +280 °C |
| Accuracy | ±2 °C or ±2 % of reading (whichever is greater) |
| Frame Rate | 9 Hz |
| Field of View | 31° × 23° |
| IFOV | 3.4 mrad (standard), 2.1 mrad (SuperResolution) |
| Minimum Focus Distance | <0.5 m |
| Display | 3.5″ LCD, 320 × 240 pixels |
| Operating Temperature | −15 to +50 °C |
| Storage Temperature | −30 to +60 °C |
| Humidity | 20–80 % RH (non-condensing) |
| IP Rating | IP54 |
| Dimensions | 219 × 96 × 95 mm |
| Weight | 510 g |
| Battery Life | ~4 h |
| Interface | USB 2.0 Micro-B |
| Image Formats | .bmt, .jpg, .bmp, .png, .xls, .csv |
| Internal Memory | 2.8 GB |
| Software | testo IRSoft (Windows 10/8/7) |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 8681 |
| Detector Type | Uncooled Microbolometer FPA (Scanning-Type) |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 160 × 120 pixels |
| SuperResolution (via testo SuperPixel) | 320 × 240 pixels |
| Thermal Sensitivity (NETD) | ≤ 0.10 °C |
| Field of View (FOV) | 31° × 23° |
| Instantaneous Field of View (IFOV) | 3.4 mrad (standard lens) |
| Frame Rate | 9 Hz |
| Temperature Range | −30 to +100 °C |
| Accuracy | ±2 °C or ±2 % of reading (whichever is greater) |
| Emissivity Adjustment | 0.01–1.00 (with ε-Assist automatic calibration) |
| Reflected Apparent Temperature Compensation | Yes (RTC-assisted) |
| Focus | Fixed-focus optimized for ≥0.5 m |
| Visible Light Camera | ≥3.1 MP, co-registered with IR |
| Display | 3.5″ LCD, 320 × 240 px |
| Storage | Internal 2.8 GB |
| Battery Life | Up to 4 h (rechargeable Li-ion) |
| Environmental Rating | IP54 |
| Operating Temperature | −15 to +50 °C |
| Weight | 510 g |
| Dimensions | 219 × 96 × 95 mm |
| Compliance | EMC Directive 2014/30/EU |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 8690 11 |
| Detector Type | Scanning Focal Plane Array |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 160 × 120 pixels |
| Thermal Sensitivity (NETD) | < 0.12 °C @ 30 °C |
| Frame Rate | 9 Hz |
| Temperature Range | −20 to +280 °C |
| Accuracy | ±3 °C or ±3 % of reading (whichever is greater) |
| Field of View | 34° × 26° |
| Minimum Focus Distance | < 0.5 m (fixed focus) |
| IFOV | 3.68 mrad |
| Display | 3.5" LCD, 320 × 240 pixels |
| Operating Temperature | −15 to +50 °C |
| Storage Temperature | −30 to +60 °C |
| Humidity Range | 20–80 % RH (non-condensing) |
| IP Rating | IP54 |
| Dimensions | 219 × 96 × 95 mm |
| Weight | 550 g |
| Battery Life | 4.0 h |
| Internal Memory | 1.6 GB (>2000 images without SuperResolution) |
| Image Formats | .bmt, .jpg, .bmp, .png, .csv, .xls |
| Software Compatibility | Windows XP SP3 through Windows 10, USB 2.0 interface |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Model | testo 869 |
| Thermal Resolution | 160 × 120 pixels |
| IR Pixel Count | 19,200 |
| Spectral Range | 7.5–14 µm |
| Thermal Sensitivity (NETD) | < 0.12 °C |
| Temperature Range | −20 to +280 °C |
| Accuracy | ±2 °C or ±2% of reading |
| Frame Rate | 9 Hz @ 160 × 120 |
| Measurement Principle | Non-contact infrared radiometry |
| Detector Type | Uncooled microbolometer |
| Operating Mode | Handheld, battery-powered |
| Image Format | JPEG |
| Software Included | testo IRSoft |
| Power Supply | Rechargeable Li-ion battery + AC adapter |
| Connectivity | USB 2.0 |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 869 |
| Thermal Resolution | 160 × 120 pixels |
| Image Resolution | 19,200 IR pixels |
| Spectral Range | 7.5–14 µm |
| NETD | < 0.12 °C |
| Temperature Range | −20 to +280 °C |
| Accuracy | ±2 °C or ±2% of reading |
| Frame Rate | 9 Hz @ 160 × 120 |
| Measurement Principle | Non-contact infrared radiometry |
| Detector Type | Uncooled microbolometer |
| Operating Mode | Handheld, battery-powered |
| Thermal Sensitivity Mode | Auto hot/cold spot tracking |
| Data Export Format | JPEG |
| Software Included | testo IRSoft (PC-based analysis suite) |
| Power Supply | Rechargeable Li-ion battery + AC adapter |
| Interface | USB 2.0 |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 8712 |
| Detector Type | Scanning Focal Plane Array |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 240 × 180 pixels |
| SuperResolution (via testo PixelBoost) | 480 × 360 pixels |
| Thermal Sensitivity (NETD) | ≤ 0.09 °C |
| Field of View | 35° × 26° |
| IFOV | 2.6 mrad (standard), 1.6 mrad (with PixelBoost) |
| Frame Rate | 9 Hz |
| Focus | Fixed-focus lens (min. distance < 0.5 m) |
| Temperature Range | −30 to +100 °C |
| Accuracy | ±2 °C or ±2 % of reading (whichever is greater) |
| Emissivity Adjustment | 0.01–1.00, with ε-Assist automatic calibration |
| Reflective Temperature Compensation | RTC-assisted |
| Measurement Modes | Hot/Cold Spot Detection, ΔT, Area Avg, Solar Mode |
| Image Output | IR + visible-light overlay (≥3.1 MP digital camera) |
| Display | 3.5″ LCD, 320 × 240 px |
| Storage | Internal 2.8 GB (BMT, JPEG, PNG, BMP, CSV, XLS) |
| Connectivity | Bluetooth 4.2 + Wi-Fi (IEEE 802.11 b/g/n), USB 2.0 Micro-B |
| Environmental Rating | IP54 |
| Operating Temp. | −15 to +50 °C |
| Battery Life | Up to 4 h (rechargeable Li-ion) |
| Compliance | RED Directive 2014/53/EU, EMC Directive 2014/30/EU |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 8722 |
| Detector Type | Uncooled Microbolometer Focal Plane Array (FPA) |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 320 × 240 pixels (SuperResolution up to 640 × 480 pixels) |
| Thermal Sensitivity (NETD) | ≤ 0.06 °C |
| Frame Rate | 9 Hz |
| Temperature Range | −30 to +100 °C |
| Accuracy | ±2 °C or ±2 % of reading |
| Measurement Method | Non-contact infrared radiometry |
| Operating Temperature | −15 to +50 °C |
| Storage Temperature | −30 to +60 °C |
| Relative Humidity | 20–80 % RH (non-condensing) |
| IP Rating | IP54 |
| IFOV | 2.3 mrad (standard lens) |
| Field of View | 42° × 30° |
| Minimum Focus Distance | < 0.5 m |
| Visible Light Camera | ≥ 3.1 MP, autofocus, 3.5″ LCD (320 × 240), brightness-adjustable backlight |
| Digital Zoom | 2× / 4× |
| Image Formats | .bmt, .jpg, .bmp, .png, .csv, .xls |
| Internal Memory | 2.8 GB |
| Connectivity | Bluetooth 4.2, Wi-Fi 802.11 b/g/n, USB 2.0 Micro-B |
| Wireless Compatibility | testo 605i (humidity/temperature), testo 770-3 (clamp meter) |
| Software | testo IRsoft (Windows 10/8/7), testo Thermography App (iOS/Android) |
| Compliance | EMC Directive 2014/30/EU, Radio Equipment Directive 2014/53/EU |
| Dimensions | 219 × 96 × 95 mm |
| Weight | 510 g |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 8832 |
| Detector Type | Uncooled Microbolometer FPA (Scanning-Type) |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 320 × 240 pixels (SuperResolution up to 640 × 480) |
| Thermal Sensitivity (NETD) | < 0.04 °C |
| Temperature Range | −30 to +650 °C |
| Accuracy | ±2 °C or ±2 % of reading (whichever is greater) |
| Field of View (Standard Lens) | 30° × 23° |
| IFOV (Standard Lens) | 1.7 mrad |
| Minimum Focus Distance | < 0.1 m |
| Frame Rate | 27 Hz (EU-compliant |
| Display | 3.5" capacitive touchscreen (QVGA, 320 × 240) |
| Image Storage | Internal 2.8 GB memory (.bmt, .jpg, .png, .csv, .xls export) |
| Battery Life | ≥ 5 h |
| IP Rating | IP54 |
| Operating Temperature | −15 to +50 °C |
| Weight | 824 g |
| Compliance | RED 2014/53/EU, EMC 2014/30/EU, WEEE 2012/19/EU, RoHS 2011/65/EU + 2015/863, REACH 1907/2006 |