| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | EPD-G |
| Instrument Category | Dose/Dose Rate Meter |
| Instrument Type | Portable |
| Measured Radiation | X-ray and Gamma (γ) Radiation |
| Detector Type | Multi-stage Solid-State Detector |
| Dose Equivalent Range | 1/64 µSv to 16 Sv |
| Dose Rate Range | 1/64 µSv/h to 16 Sv/h |
| Accuracy | ±10% (referenced to Cs-137, 662 keV) |
| Energy Response | 15 keV – 10 MeV |
| Power Supply | Two AA 1.5 V alkaline batteries (8 weeks continuous operation) or one 3.6 V lithium battery (5 months continuous operation) |
| Data Retention | 10 years without power |
| Memory Capacity | Adjustable logging interval down to 1 s |
| Security | Password-protected data storage area |
| Compliance | Designed for use in accordance with IEC 61526:2010 (Radiation protection instrumentation — Measurement of personal dose equivalents Hp(10) and Hp(0.07) for X, gamma, neutron and beta radiations) and meets requirements for routine occupational monitoring under ISO 4037 and ANSI N42.20 |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic |
| Model | Evolution 200 Series |
| Instrument Architecture | Double-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Selection |
| Spectral Bandwidth | Variable at 1 nm or 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <0.05% T at 220 nm and 340 nm |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Imported |
| Model | Evolution 260 |
| Optical Design | Double-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.8 nm |
| Spectral Bandwidth | 1.0 nm and 2.0 nm |
| Stray Light | ≤1% T |
| Automation | Motorized Wavelength Selection |
| Light Source | Xenon Flash Lamp |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Exactive LC/MS – Benchtop FT Orbitrap High-Resolution LC-MS |
| Instrument Category | Ion Trap |
| Price Range | USD 140,000 – 280,000 (based on configuration and regional duties/taxes) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | Exactive |
| Instrument Type | Orbitrap-based LC-MS |
| Price Range | USD 130,000 – 260,000 (estimated FOB) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Exactive Plus (EMR) Orbitrap LCMS |
| Instrument Type | Orbitrap-based LC-MS |
| Mass Range | Extended up to 6,000 m/z (with EMR option) |
| Resolution | Up to 140,000 FWHM @ m/z 200 |
| Mass Accuracy | < 3 ppm RMS (internal calibration), < 5 ppm RMS (external calibration) |
| Sensitivity | Sub-femtomole level for peptides (S/N ≥ 10 in full-scan mode) |
| Exact Mass Measurement | Yes, with real-time internal lock mass correction |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Exactive Plus EMR LC-MS System |
| Price Range | USD 140,000 – 280,000 (estimated FOB US port) |
| Instrument Type | Orbitrap-based Liquid Chromatography Mass Spectrometer |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | FirstDefender RM |
| Instrument Category | Portable/Handheld Raman Spectrometer |
| Spectral Range | 250 cm⁻¹ to 2875 cm⁻¹ |
| Spectral Resolution | 7–10.5 cm⁻¹ |
| Spatial Resolution | 1 µm (lateral), 1 µm (axial) |
| Minimum Wavenumber | 250 cm⁻¹ |
| Spectral Repeatability | ≤ ±0.5 cm⁻¹ |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | FirstDefender RMX |
| Instrument Category | Portable/Handheld Raman Spectrometer |
| Spectral Range | 250 cm⁻¹ to 2875 cm⁻¹ |
| Spectral Resolution | 7–10.5 cm⁻¹ (FWHM) |
| Minimum Wavenumber | 250 cm⁻¹ |
| Spectral Repeatability | ≤ ±0.5 cm⁻¹ |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Flash 2000HT |
| Price Range | USD 420,000 – 700,000 |
| Instrument Type | Stable Gas-Source Isotope Ratio Mass Spectrometry (IRMS) Interface System |
| Analytical Precision | High-precision δ-value reproducibility (typical 1σ < 0.2‰ for δ¹³C, δ¹⁵N, δ³⁴S, δ²H, δ¹⁸O) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model | Scientific™ Forma™ |
| Effective Capacity | 368 L |
| Interior Dimensions (mm) | 1308 × 584 × 490 |
| Exterior Dimensions (mm) | 1979 × 846 × 836 |
| Power Supply | 230 V / 50 Hz |
| Rated Power | 400 W |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Handheld Dual-Mode Spectrometer (Raman + FTIR) |
| Model | Gemini |
| Spectral Range (Raman) | 250–2875 cm⁻¹ |
| Spectral Resolution (Raman) | 7–10.5 cm⁻¹ (FWHM, full range) |
| Spectral Resolution (FTIR) | 4 cm⁻¹ |
| Minimum Wavenumber (Raman) | 250 cm⁻¹ |
| Minimum Wavenumber (FTIR) | 650 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.5 cm⁻¹ shift across three consecutive scans of identical sample under fixed acquisition conditions |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Genesys 10s |
| Instrument Architecture | Double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Speed | Up to 4200 nm/min |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.3 nm |
| Stray Light | <0.05% T at 220 nm and 340 nm |
| Light Source | Pulsed Xenon Flash Lamp (3-year warranty) |
| Grating | Holographic Master Grating |
| Cuvette Changer | Integrated 6-position Auto-Changer |
| Data Storage | USB flash drive support |
| Compliance | Designed to support USP <85>, EP 2.2.25, and JP 17 UV-Vis validation protocols |
| Software Options | GENESYS Instrument Control Software (PC-based), optional FDA 21 CFR Part 11-compliant audit trail module |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | GENESYS 150 |
| Optical Design | Double-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Selection | Manual |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <1.0%T at 198 nm (KCl), <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO₂) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | MARS iQ |
| Instrument Category | Rotational Rheometer |
| Bearing Type | Mechanical Ball Bearing |
| Minimum Rotational Speed | 0.01 rpm |
| Maximum Rotational Speed | 2000 rpm |
| Frequency Range | 0.01–20 Hz |
| Maximum Torque | 125 mN·m |
| Torque Resolution | 2.0 µN·m |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Rotational Rheometer Coupling Module |
| Model | Rheonaut |
| Motor Bearing | Air Bearing |
| Minimum Rotational Speed | 1 × 10⁻⁸ rpm |
| Frequency Range | 10⁻⁶ – 100 Hz |
| Maximum Rotational Speed | 4500 rpm |
| Maximum Torque | 200 mN·m |
| Torque Resolution | 0.1 nN·m |
| ATR Crystal Material | Diamond (Single-Reflection) |
| Temperature Control Options | Peltier (0–120 °C) or Electric Heating (RT–400 °C) |
| Detector | DTGS |
| Polarization Options | Manual/Automatic Dual-Axis Polarizers |
| Compliance | ASTM D3835, ISO 6721-10, USP <1043>, GLP/GMP-ready data audit trail support |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Harshaw TLD |
| Instrument Category | Radiation Dosimetry / Dose Rate Meter |
| Form Factor | Personal/Environmental Wearable |
| Measured Radiation Types | Photons, Beta Particles, Thermal Neutrons, Fast Neutrons |
| Detector Material | LiF:Mg,Cu,P |
| LiF | Mg,Ti |
| Dosimetric Quantities | Hp(10), Hp(3), Hp(0.07), H*(10), H′(0.07), Neutron Fluence-to-Dose Conversion |
| Window Thickness | 3.3 mg/cm² (beta), 42 mg/cm² (photon), 7 mg/cm² (TLD-100/H/700H), 100 mg/cm² (TLD-100 for high-energy photon attenuation) |
| Element Dimensions | 3 mm × 0.4 mm (neutron-sensitive chips) |
| Compliance | ANSI N545-1993, ANSI N13.32-1995, ANSI N13.37 (draft), DOELAP, NVLAP-accredited testing protocols |
| Software | Integrated dose calculation software with ANSI/ISO traceable algorithms |
| Packaging | Hermetically sealed, barcoded, contamination-resistant encapsulation |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Multi-Collector Static Vacuum Noble Gas Isotope Ratio Mass Spectrometer |
| Model | HELIX MC Plus |
| Isotopes Measured | Ne, Ar, Kr, Xe (up to 5 simultaneously) |
| Mass Range | Full noble gas isotopic range (1–132 amu) |
| Resolution | >750 (10% valley, standard receivers), >1,500 (10% valley, high-resolution receivers) |
| Detector Configuration | Faraday cups + CCD multi-collector array with configurable amplifier gains (10¹⁰ Ω, 10¹¹ Ω, 10¹² Ω, 10¹³ Ω) |
| Dynamic Range | >12 orders of magnitude (Faraday + CCD hybrid detection) |
| Application Focus | High-precision noble gas isotope ratio analysis in geochronology, cosmochemistry, nuclear forensics, and mantle geochemistry |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Rare Gas Isotope Ratio Mass Spectrometer |
| Model | HELIX SFT |
| Measurement Range | Full mass range for noble gases (He, Ne, Ar, Kr, Xe) |
| Resolution | >700 at low mass (e.g., m/z 3), enabling baseline separation of ³He from HD⁺ and H₃⁺ interferences |
| Abundance Sensitivity | <1 ppb at m/z 4 relative to m/z 3 |
| Internal Volume | ~1400 cm³ |
| Amplifier Options | 10¹⁰ Ω, 10¹¹ Ω, 10¹² Ω, and 10¹³ Ω Faraday cup amplifiers |
| Detection Modes | Simultaneous multi-collection (e.g., ³He/⁴He) and peak-jumping for full noble gas isotope systems |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | iCAP MSX ICP-MS |
| Price | Upon Request |
| Application Environment | Laboratory |
| Mass Range | 2–290 u |
| Resolution (Unit Mass Resolution) | User-Configurable |
| Detection Limits (ng·L⁻¹) | ⁹Be < 0.3, ¹¹⁵In < 0.1, ²⁰⁹Bi < 0.1 |
| Sensitivity (Mcps / mg·L⁻¹) | Standard Mode — ⁷Li: 80, ⁵⁹Co: 290, ¹¹⁵In: 600, ²⁰⁹Bi: 500, ²³⁸U: 850 |
| He KED Mode — ⁵⁹Co | 70 |
| Short-Term Stability (RSD, 10 min) | < 2% |
| Long-Term Stability (RSD, 2 h) | < 3% |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | iCAP MTX ICP-MS |
| Application | Laboratory-based elemental and isotopic analysis |
| Mass Range (amu) | 2–290 u (m/z >225 available only with intelligent Mass Resolution [iMR] enabled) |
| Resolution (Unit Mass Resolution, amu) | User-configurable |
| Detection Limits (ng·L⁻¹) | ⁹Be <0.3, ¹¹⁵In <0.1, ²⁰⁹Bi <0.1 |
| TQ-O₂ mode | ³²S (as SO⁺) <50, ³¹P (as PO⁺) <15, ⁷⁸Se (as SeO⁺) <1, ²⁸Si (as SiO⁺) <50 |
| Sensitivity (Mcps/mg·L⁻¹) | Standard Mode: ⁷Li 65, ⁵⁹Co 180, ¹¹⁵In 400, ²⁰⁹Bi 340, ²³⁸U 550 |
| KED Mode | ⁵⁹Co 60 |
| Short-term Stability (RSD, 10 min) | <2% |
| Long-term Stability (RSD, 2 h) | <3% |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | iCAP RQ |
| Instrument Type | Quadrupole ICP-MS |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Instrument Type | Quadrupole ICP-MS |
| Model | iCAP RQ |
| Vacuum System | High-vacuum dual-stage turbomolecular pumping |
| RF Generator | Solid-state, 27.12 MHz, auto-tuning |
| Collision/Reaction Cell | Quadrupole-based with KED (Kinetic Energy Discrimination) mode |
| Detection Range | Li (m/z 6) to U (m/z 238) |
| Detection Limit | Sub-pg/L (ppt) for low-mass elements in He KED mode |
| Sample Introduction | Compatible with standard nebulizers, microflow systems, and laser ablation interfaces |
| Regulatory Compliance | Designed for EPA Method 6020B, ISO/IEC 17025, USP <232>/<233>, FDA 21 CFR Part 11 support via Qtegra ISDS software |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | iCAP RQplus ICP-MS |
| Price | Upon Request |
| Application Environment | Laboratory |
| Mass Range (amu) | 2–290 |
| Unit Mass Resolution (amu) | 2–290 |
| Instrument Detection Limits (ng·L⁻¹) | Be < 0.5, In < 0.1, Bi < 0.1 |
| Sensitivity (Mcps / mg·L⁻¹) | Li > 65, Co > 110, In > 270, U > 400 |
| Short-Term Stability (RSD, 10 min) | < 2% |
| Long-Term Stability (RSD, 2 h) | < 3% |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Thermo Scientific™ iCAP™ TQ ICP-MS |
| Instrument Type | Triple Quadrupole ICP-MS |
| Price Range | USD 420,000 – 700,000 (approx. based on exchange rate and configuration) |
| Software Platform | Thermo Scientific Qtegra ISDS v3.x or later |
| Brand | Thermo Fisher |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Flame AAS |
| Monochromator | Plane Grating (1800 lines/mm) |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal Method |
| Wavelength Range | 190–900 nm |
| Focal Length | 270 mm |
| Slit Widths | 0.2, 0.5, 1.0, 2.0 nm (motorized) |
| Lamp Holder | 6-position, fully automated, independent lamp power supplies |
| Burner Head | Titanium alloy, finned design, optional 50 mm or 100 mm length |
| Nebulizer Chamber | Inert PTFE-nozzle & Pt/Ir capillary |
| Gas Control | Binary-valve digital pneumatic system for air/acetylene and N₂O/acetylene |
| Brand | Thermo Fisher |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | iCE 3400 |
| Instrument Type | Graphite Furnace AAS |
| Monochromator | Echelle Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Zeeman Electro-Magnetic Field Correction |
| Brand | Thermo Fisher |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | iCE 3500 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Echelle Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal (Auto-Absorption) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Instant Connect ECD |
| Instrument Type | Electron Capture Detector |
| Price Range | USD 2,700 – 6,800 (FOB Italy) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | NPD Detector |
| Instrument Category | Element-Selective Chromatographic Detector |
| Compatibility | Designed for Thermo Scientific TRACE 1300/1310 GC and ISQ EC/LSQ MS platforms |