Thermo Fisher
Filter
Showing 361–390 of 1004 results
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Star A215 |
| Price | Upon Request |
| pH Range | –2.000 to 19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| pH Calibration | 1–5 points, NIST/US, DIN, or user-defined buffers |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| Conductivity Range | 0.000 µS/cm to 3000 mS/cm |
| Conductivity Resolution | 4 significant digits, down to 0.001 µS/cm |
| Conductivity Accuracy | ±0.5% ±1 digit or ±0.01 µS/cm (whichever is greater) |
| Resistivity Range | 0.0001–100 MΩ·cm |
| Salinity | 0.01–80.0 ppt NaCl |
| TDS | 0–19999 mg/L |
| Cell Constant Range | 0.001–199.9 cm⁻¹ |
| Reference Temperatures | 5, 10, 15, 20, or 25 °C |
| Electrode Compatibility | Two-electrode, four-electrode, and planar conductivity cells |
| Temperature Range | –5 to 105 °C |
| Temperature Resolution | 0.1 °C (–5 to 99.9 °C), 1.0 °C (>99.9 °C) |
| Temperature Accuracy | ±0.1 °C |
| Temperature Compensation | Automatic or manual |
| Display | Backlit LCD with icon-driven interface |
| Connectivity | BNC (pH), miniDIN (temperature), phono-jack (stirrer control for benchtop), RS232 (bidirectional), optional USB cable |
| Data Storage | 750 measurements |
| Calibration History | Last 10 calibrations |
| Method Storage | 10 user-defined methods |
| Password Protection | Up to 10 user accounts |
| Power | 4×AA alkaline batteries (up to 2000 h in portable mode) |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| IP Rating | Benchtop — IP54 (dust-protected, splash-resistant) |
| Dimensions (Benchtop) | 9.4 × 17.0 × 22.4 cm (H×W×L) |
| (Portable) | 4.8 × 9.7 × 21.3 cm (H×W×L) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable |
| Measurement Principle | Polarographic & Luminescent (RDO) |
| DO Range | 0–90 mg/L (polarographic), 0–50 mg/L (RDO) |
| Accuracy | ±0.2 mg/L (polarographic), ±0.1–±0.2 mg/L + 10% (RDO) |
| Saturation Range | 0–600% (polarographic), 0–500% (RDO) |
| Temperature Range | 0–50 °C |
| Temp Accuracy | ±0.1 °C |
| Atmospheric Pressure Compensation | 450.0–850.0 mmHg |
| Salinity Correction | 0–45 ppt |
| Data Storage | 2000 datasets (GLP-compliant) |
| IP Rating | IP67 |
| Interface | 9-pin mini-DIN probe port, USB, RS232 |
| Power | 4 × AA batteries or AC adapter |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Orion Star T910 |
| Instrument Category | General-purpose Potentiometric Titrator |
| Measurement Range | pH: −2.000 to 20.000 |
| mV | −2000 to +2000 mV |
| Temperature | −5 to 100 °C |
| Meter Accuracy | ±0.2% of full scale |
| Meter Resolution | pH: 0.001 |
| mV | 0.1 mV |
| Temperature | 0.1 °C |
| Titration Accuracy | (±0.3 mV ±1 digit) over 3 h |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | VERSA STAR (VM-01 refers to base configuration) |
| Compliance | GLP, USP <645>, ASTM D1125, ISO 7888, ISO 5814, ISO 10523, FDA 21 CFR Part 11 (with optional audit trail software) |
| Data Storage | 2000 GLP-compliant entries |
| Connectivity | Dual USB + RS232 |
| Module Capacity | Up to 4 simultaneous modules |
| IP Rating | IP54 |
| Power | 90–260 V AC, 50–60 Hz |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Model | Orion™ 3106 COD |
| Instrument Type | Online Analyzer |
| Measurement Principle | Potassium Dichromate Digestion with Photometric Detection |
| Wavelength | 450 nm |
| Measurement Ranges | 20–200–800–2000 mg/L COD |
| Accuracy | ±5 mg/L (for values <50 mg/L) or ±10% (for values >50 mg/L) |
| Repeatability | ≤5% |
| Limit of Detection (LOD) | 4 mg/L |
| Cycle Time | 40 min per sample |
| Sample Throughput | 500 samples per batch |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | Orion™ 3106 COD |
| Instrument Type | Online Analyzer |
| Measurement Principle | Potassium Dichromate Oxidation Digestion (Online Mode) |
| Detection Wavelength | 450 nm |
| Measurement Ranges | 20–200–800–2000 mg/L (auto-ranging) |
| Accuracy | ±5 mg/L (for values <50 mg/L) or ±10% (for values >50 mg/L) |
| Repeatability | ≤5% RSD |
| Limit of Detection (LOD) | 4 mg/L |
| Cycle Time | 40 minutes per sample |
| Sample Throughput | Up to 500 samples per batch |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | ORPTestr 10 |
| Electrode Type | Double-Junction |
| Interface | BNC (ORPTestr 10 BNC variant) |
| Measurement Range | −999 to +1000 mV |
| Resolution | 1 mV |
| Accuracy | ±2 mV |
| Calibration | Single-point manual |
| Temperature Compensation | None |
| Operating Temperature | 0–50 °C |
| Display | Dual-line LCD (2.1 × 2.7 cm) |
| Power | 4 × 1.5 V button cells |
| Battery Life | >500 hours |
| Dimensions (Instrument Only) | 16.5 × 3.8 cm |
| Weight (Instrument Only) | 90 g |
| Packaging Dimensions | 18.5 × 6.5 × 5 cm |
| Package Weight | 200 g |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | pDR-1000AN |
| Measurement Principle | Optical Light Scattering (Forward Scatter at 50–90°) |
| Measured Parameters | PM₁₀, PM₂.₅ |
| Detection Range | 0.001–400 mg/m³ |
| Particle Size Response | 0.1–10 µm |
| Output | Analog Voltage & Digital Serial (RS-232), Optional Alarm Relay |
| Weight | 0.5 kg |
| Dimensions | Palm-sized (approx. 12.7 × 8.9 × 4.4 cm) |
| Power | AC Adapter or Optional Rechargeable Battery |
| Calibration Traceability | NIST-traceable gravimetric calibration using SAE test dust |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory-Scale Twin-Screw Extruder |
| Model | Pharma 11 |
| Minimum Throughput | 20 g/h |
| Maximum Throughput (GMP Mode) | 2.5 kg/h |
| Application Scope | Preclinical Formulation Development, Clinical Trial Material (CTM) Manufacturing, Scale-Up Studies |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Pharma 16 |
| Price | Upon Request |
| Screw Diameter | 15.6 mm |
| Barrel Diameter | 16 mm |
| L/D Ratio | 25:1 to 40:1 (modular) |
| Motor Power | 2.5 kW |
| Max Screw Speed | 1000 rpm |
| Free Volume | 6–109 cm³ |
| Voltage/Phase/Current | 400 V / 3-phase / 20 A |
| Throughput | 1–5 kg/h |
| Barrel Material | Pharmaceutical-grade stainless steel (e.g., AISI 316L) |
| Drive | Brushless AC inverter motor |
| Control System | Touchscreen HMI with PLC-based data acquisition |
| Compliance | Designed per EU GMP Annex 1 & ICH Q5A/Q5C principles |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Pharma 24 |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Country of Origin | Imported |
| Model | Pharma Mini |
| Motor Power | 400 W |
| Speed Range | 10–360 rpm |
| Screw Configuration | Conical Co-rotating or Counter-rotating |
| Max Operating Temperature | 280 °C |
| Heating Time (22–170 °C) | < 10 min |
| Free Volume | 3 g (4 mL) |
| Screw Material | Medical-Grade Stainless Steel 1.4112 (AISI 440B) |
| Barrel Material | High-Performance Pharmaceutical-Grade Stainless Steel M340 |
| IP Rating | IP54 |
| Production Capacity | Up to 100 g/h |
| Controller | Touchscreen with User-Level Access Control and Password Protection |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | picoSpin 45 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Form | Liquid Only |
| Sensitivity | ≥600:1 SNR for Single-Scan H₂O |
| Resolution | 2.25 Hz (measured on 1% ethylbenzene in CDCl₃) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | picoSpin 80 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Form | Liquid |
| Sensitivity | 18 ppb (at 1.44 Hz linewidth) |
| Resolution | 5000 (for H₂O, single-scan) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Imported |
| Models | PLR221, PLR1006, PLR386, PLF276 |
| Refrigeration Temperature Range | 1–12 °C (Factory-Set at 4 °C) |
| Effective Internal Volume | 1006 L |
| Internal Width | 58 cm |
| External Height | 120 cm |
| Cooling Method | Forced-Air Active Cooling |
| Temperature Uniformity | ±3 °C |
| Defrost Type | Automatic |
| Insulation | High-Density CFC-Free Polyurethane Foam |
| Door Configuration | Dual-Door (PLR1006), Double-Glazed Tempered Glass |
| Shelving | Adjustable, Heavy-Duty Steel |
| Security | Integrated Locking Mechanism |
| Mobility | Standard Swivel Casters with Brakes |
| Interface | Digital Temperature Display with Audible/Visual High/Low Alarms |
| Additional Features | Key Switch, Interior LED Lighting, 25 mm Pass-Through Port |
| Brand | Thermo Fisher |
|---|---|
| Model | PL8300 Series |
| Temperature Ranges | +2 °C to +8 °C (Refrigerator), −20 °C (Freezer) |
| Refrigerant | Hydrocarbon (R600a) |
| Compressor | Imported Inverter Compressor |
| Evaporator & Condenser | Copper-Fin Tube Design |
| Insulation | High-Density Polyurethane Foam with Cyclopentane Blowing Agent |
| Fan System | German EBM EC Fans (Evaporator & Condenser) |
| Noise Level | <50 dB(A) (Refrigerator), <52 dB(A) (Freezer) |
| Sensor Configuration | 6-Channel Independent Temperature Monitoring (e.g., Left/Right, Top/Middle/Bottom) |
| Alarms | High/Low Temperature, Sensor Failure, Power Failure, Door Ajar |
| Data Interface | USB Port (PDF Export), Optional RS485 |
| Certifications | Compliant with IEC 61000-6-3 (EMC), IEC 61000-6-2 (Immunity), ISO 13485-aligned Design Controls |
| Standard Features | Heated Glass Door (Refrigerator), Auto-Evaporating Drain Pan, LED Interior Lighting (Switchable), Adjustable Shelves/Drawers, Casters + Leveling Feet, Anti-Icing Heater (Freezer Door Seal) |
| Optional Accessories | Padlock Kit, Thermal Printer Module |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Circulating Water Bath |
| Models | TSCIR19 / TSCIR35 / TSCIR89 |
| Bath Capacity | 19 L / 35 L / 89 L |
| Temperature Range | +5 °C to 100 °C |
| Temperature Stability | ±0.1 °C (±0.05 °C at 70 °C) |
| Circulation Type | Internal Recirculation |
| Control System | Microprocessor-Based PID Controller |
| Display | Icon-Driven Graphical LCD |
| Safety Features | Low-Level Fluid Detection, Audible Alarm, Over-Temperature Protection |
| Construction | Stainless Steel Bath Chamber with Removable Perforated Lid and Diffuser Tray |
| Power Rating | 1200 W (TSCIR19), 1500 W (TSCIR35 & TSCIR89) |
| Working Chamber Dimensions (L × W × H) | 305 × 387 × 192 mm (TSCIR19), 305 × 692 × 192 mm (TSCIR35), 483 × 914 × 241 mm (TSCIR89) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Prima BT |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrumentation |
| Models | Prima PRO, Prima BT |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Czech Republic |
| Model | Prisma E SEM |
| Instrument Type | Floor-standing SEM |
| Electron Source | Tungsten Filament |
| Secondary Electron Resolution | 3.0 nm @ 30 kV (SE), 8.0 nm @ 3 kV (SE) |
| Backscattered Electron Resolution | 4.0 nm @ 3 kV (BSE), 10 nm @ 3 kV (SE) |
| Accelerating Voltage | 200 V – 30 kV |
| Magnification Range | 5× – 1,000,000× |
| Low Vacuum Range | up to 130 Pa |
| ESEM Mode Pressure | up to 2600 Pa (H₂O), 4000 Pa (N₂) |
| Sample Chamber Width | 340 mm |
| Expandable Ports | 12 total, including 3 EDS ports (2 at 180° opposing positions) |
| Stage | 5-axis motorized eucentric stage (X=110 mm, Y=110 mm, Z=65 mm, T=–15° to 90°, R=360° continuous) |
| Standard Detectors | ETD (high-vacuum SE), LVD (low-vacuum SE), GSED (ESEM SE), IR CCD camera in chamber |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ProFlex™ PCR System |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Q Exactive Orbitrap LCMSMS |
| Instrument Type | Orbitrap Hybrid Quadrupole–Orbitrap Mass Spectrometer |
| Price Range | USD 650,000 – 980,000 (FOB USA) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Real-Time Quantitative PCR Instrument |
| Model | QuantStudio 12K Flex |
| Sample Throughput | Supports OpenArray® plates, TaqMan® Array Cards, 384-well, 96-well, and Fast 96-well plates |
| Regulatory Compliance | FDA 21 CFR Part 11 (optional SAE module), GLP/GMP-ready architecture |
| Software Platform | Thermo Fisher Cloud with Applied Biosystems qPCR Analysis Module, ExpressionSuite v1.0, Genotyper v1.1, MeltDoctor™ HRM analysis |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin Classification | Domestically Manufactured |
| Model | QuantStudio 5 Real-Time PCR System (Domestically Manufactured) |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Canada |
| Model | Trace 2000 |
| Configuration | Dual Electron Capture Detectors (ECD), Split/Splitless (S/SL) Injector |
| Instrument Type | Gas Chromatograph (GC) |
| Age | 4–5 years |
| Warranty | 6 months |
| Certification | Refurbished & Factory-Tested |
| Compliance | Meets ASTM D3612, EPA Method 8081B/8270, ISO 10380, and USP <621> for residual solvent analysis |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | RadEye AB100 |
| Instrument Category | Dose Rate / Contamination Meter |
| Form Factor | Portable |
| Detector Type | Zinc-Loaded Plastic Scintillator |
| Active Detection Area | 69 mm × 145 mm (10,005 mm²) |
| Effective Sensitivity Area | 2500 px² (≈ 100 cm² equivalent in operational context) |
| Window Thickness | 0.87 mg/cm² aluminum-coated polymer foil |
| Alpha Efficiency (²⁴¹Am) | 36% |
| Beta Efficiency (⁶⁰Co) | 25% |
| Beta Efficiency (⁹⁰Sr/⁹⁰Y) | 49% |
| Gamma Response (¹³⁷Cs) | ~40 cps per µSv/h |
| Battery Life | Up to 1000 hours on NiMH rechargeable pack |
| Compliance | Meets ANSI N42.33, IEC 60846-1, and ISO 7503-1 for surface contamination monitoring |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | RadEye B20 |
| Instrument Type | Portable Radiation Survey Meter |
| Radiation Types Detected | Alpha, Beta, Gamma, and X-ray |
| Detector Type | Thin-window Geiger-Müller (GM) Tube with 44 mm Active Diameter and Adjustable Window Thickness (1.8–20 mg/cm²) |
| Dose Rate Range (γ) | 0–2 mSv/h (RadEye B20) |
| Count Rate Range (Contamination) | 0–10 kcps (B20) |
| Energy Response (with γ energy window) | 17 keV – 3 MeV |
| 2π Detection Efficiency | ²⁴¹Am: 28%, ⁶⁰Co: 25%, ⁹⁰Sr/⁹⁰Y: 36%, ¹⁴C: 19% |
| Calibration Source | 9 g Lutetium Oxide (Lu₂O₃) reference source, activity density 50 Bq/g (1.4 nCi/g) |
| Alarm Modes | Audible, Visual (LED), and Vibratory |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | RadEye G-10 |
| Instrument Category | Dose Rate Meter |
| Form Factor | Portable |
| Radiation Types Measured | X-ray and Gamma (γ) |
| Detector Type | Energy-Compensated Geiger-Müller (GM) Tube |
| Measurement Range | 0.5 µSv/h to 100 mSv/h |
| Energy Response Range | 50 keV to 3 MeV |
| Sensitivity (¹³⁷Cs) | 1.7 cps per µSv/h |
| Compliance | ANSI N42.33-2021, NATO AEP-117 Ed.3 |
| Battery Life | Up to 600 hours on two AAA alkaline cells |
| Environmental Robustness | Vibration-resistant housing, IP65-rated enclosure |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | RadEye G-EX |
| Instrument Category | Dose Rate Meter |
| Form Factor | Portable |
| Radiation Types Detected | Alpha, Beta, Gamma, Neutron |
| Measurement Range | 0.5 μSv/h – 100 mSv/h |
| Sensitivity (Cs-137, 662 keV) | ~1.7 cps/μSv/h |
| Ingress Protection | IP65 |
| ATEX Certification | II 2G Ex ia IIB T4, IBExU 10ATEX 1096 |
| Weight | 160 g |
| Display | Backlit High-Contrast LCD |
| Alarm Modes | Dual Adjustable Thresholds (Dose & Dose Rate) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Radiation Survey Meter |
| Instrument Category | Gamma and Neutron Dose Rate Meter |
| Model | RadEye GN |
| Detection Principle | Dual-channel scintillation detection (CsI:Tl for gamma, LiI(Eu) for thermal neutrons) |
| Gamma Energy Range | 30 keV–1.3 MeV |
| Neutron Sensitivity | Cf-252 source, 4.3 cps per 20,000 n/s |
| Gamma Dose Rate Range (H*(10), energy-compensated) | 0.01 μSv/h–250 μSv/h |
| Gamma Dose Rate Energy Compensation Range | 45 keV–1.3 MeV |
| Neutron Counting Rate | 0.1–1000 cps |
| Dimensions | 96 mm × 61 mm × 31 mm |
| Weight | 160 g |
| Gamma Efficiency | Am-241: 900 cps/(μSv/h), Cs-137: 130 cps/(μSv/h), Co-60: 60 cps/(μSv/h) |