Thermo Fisher
Filter
Showing 331–360 of 1004 results
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestically Assembled (China) |
| Model | Orbitrap Exploris™ 120 |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Orbitrap Fusion Lumos |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thermo Orbitrap Fusion Tribrid High-Resolution Mass Spectrometer |
| Price | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Orbitrap ID-X™ |
| Instrument Type | Orbitrap-based Tribrid™ Mass Spectrometer |
| Configuration | Integrated with Quadrupole, Linear Ion Trap, and Orbitrap™ Analyzers |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Orbitrap IQ-X Tribrid |
| Instrument Type | Orbitrap-based Tribrid Mass Spectrometer |
| Application Specificity | Dedicated for Small Molecule and Biomolecule Characterization |
| Sensitivity | 1,000,000 (1M) at m/z 200 (S/N ≥ 50:1 for reserpine) |
| Resolution | Up to 1,000,000 at m/z 200 (with optional ultra-high-resolution acquisition) |
| Key | Brand: Thermo Fisher |
|---|---|
| Origin | USA |
| Part Number | 07884 |
| Category | Mass Spectrometry Component |
| Import Status | Imported OEM Part |
| Distributor Type | Authorized Third-Party Distributor |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | 3-Star |
| Price | Upon Request |
| DO Range | 0.00–90.0 mg/L |
| DO Resolution | 0.1 / 0.01 mg/L |
| % Saturation Range | 0.0–600% |
| % Saturation Resolution | 1 / 0.1% |
| DO Accuracy | ±0.5% ±1 digit |
| Salinity Compensation | 0–45 ppt |
| Barometric Pressure Range | 450–850 mmHg |
| Calibration Methods | Air-saturated water, Water-saturated air, Winkler titration, Zero-point |
| Electrode Type | Polarographic membrane electrode |
| Temperature Range | −5 to 105 °C |
| Temperature Resolution | 0.1 °C (−5 to 99.9 °C), 1.0 °C (>99.9 °C) |
| Temp Accuracy | ±0.1 °C |
| Temp Compensation | Automatic or manual |
| Display | Backlit LCD with icon-driven interface |
| Input Interfaces | pH-BNC, temperature-miniDIN, stirrer-Phono-jack (benchtop only) |
| Communication | Bidirectional RS232, optional USB cable |
| Data Logging | 1000 readings |
| Calibration History | Last 10 calibrations |
| Method Storage | 10 user-defined methods |
| Password Protection | Up to 10 user accounts |
| Power | 4×AA batteries |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45 °C, 5–85% RH (non-condensing) |
| IP Rating | Benchtop—IP54 |
| Dimensions (Benchtop) | 9.4 × 17.0 × 22.4 cm (H×W×L) |
| (Portable) | 4.8 × 9.7 × 21.3 cm (H×W×L) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | 3-Star |
| Price | Upon Request |
| pH Range | -2.000 to 19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| Calibration Points | 1–5-point with US/NIST, DIN, or Custom Buffers |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| Temperature Range | -5 to 105 °C |
| Temperature Resolution | 0.1 °C (-5 to 99.9 °C), 1.0 °C (>99.9 °C) |
| Temperature Accuracy | ±0.1 °C |
| Temperature Compensation | Automatic or Manual |
| Display | Backlit LCD |
| Electrode Interface | pH – BNC |
| Communication | Bidirectional RS232, optional USB cable |
| Data Logging | 1000 readings |
| Calibration History | Last 10 calibrations |
| Method Storage | 10 user-defined methods |
| Password Protection | 10 user accounts |
| Power | 4×AA batteries |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45 °C, 5–85% RH (non-condensing) |
| IP Rating | Benchtop – IP54 |
| Dimensions (Benchtop) | 9.4 × 17.0 × 22.4 cm (H×W×L) |
| Dimensions (Portable) | 4.8 × 9.7 × 21.3 cm (H×W×L) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | 5-Star |
| Price | Upon Request |
| pH Range | −2.000 to 19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| pH Calibration | 1–5 points, US/NIST, DIN, or user-defined buffers |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| Ion Concentration Range | 0–19999 |
| Ion Resolution | 1–3 significant digits |
| Ion Units | M, mg/L, %, ppb, or unitless |
| Conductivity Range | 0.000–3000 mS/cm |
| Conductivity Resolution | down to 0.001 µS/cm (4-digit effective) |
| Conductivity Accuracy | ±0.5% ±1 digit or ±0.01 µS/cm (whichever is greater) |
| Resistivity Range | 0.0001–100 MΩ·cm |
| Salinity Range | 0.01–80.0 ppt NaCl |
| TDS Range | 0–19999 mg/L |
| Cell Constant Range | 0.001–199.9 cm⁻¹ |
| Reference Temperatures | 5, 10, 15, 20, or 25 °C |
| Electrode Compatibility | 2-electrode, 4-electrode, and planar conductivity cells |
| Conductivity Calibration | 1–5 points (manual) or 1–3 points (auto) |
| DO Range | 0.00–90.0 mg/L (0.0–600%) |
| DO Resolution | 0.01 mg/L / 0.1% |
| DO Accuracy | ±0.5% ±1 digit |
| Salinity Compensation | 0–45 ppt |
| Barometric Pressure Range | 450–850 mmHg |
| DO Calibration Methods | air-saturated water, water-saturated air, Winkler titration, zero-point |
| DO Sensor Type | polarographic membrane electrode |
| Temperature Range | −5 to 105 °C |
| Temperature Resolution | 0.1 °C (−5 to 99.9 °C), 1.0 °C (>99.9 °C) |
| Temperature Accuracy | ±0.1 °C |
| Temp Compensation | automatic or manual |
| Display | backlit LCD with icon-driven interface |
| Input Interfaces | pH–BNC, temperature–miniDIN, stirrer–phono jack (benchtop only) |
| Communication | bidirectional RS232, optional USB cable |
| Data Logging | 500 measurements |
| Calibration History | last 10 calibrations |
| Method Storage | 10 user-defined methods |
| Password Protection | 10 user accounts |
| Power | 4×AA batteries (portable) |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45 °C, 5–85% RH (non-condensing) |
| IP Rating | benchtop–IP54 |
| Dimensions (benchtop) | 9.4 × 17.0 × 22.4 cm (H×W×L) |
| (portable) | 4.8 × 9.7 × 21.3 cm (H×W×L) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Portable |
| Measurement Principle | Amperometric Electrochemical Sensor |
| Measurable Parameters | Free Chlorine, Total Chlorine, pH, Chlorine Dioxide, Cyanuric Acid |
| Free Chlorine Range | 0.02–4.0 mg/L (US EPA Validated Range: 0.03–2.0 mg/L) |
| Total Chlorine Range | 0.02–4.0 mg/L (US EPA Validated Range: 0.03–2.0 mg/L) |
| Chlorine Dioxide Range | 0–9 mg/L |
| pH Range | 5.9–8.2 |
| Cyanuric Acid Range | 5–90 mg/L |
| Sample Volume | 10 mL |
| Display | LCD |
| Power | 4×AAA batteries (≥3000 measurements, auto-off) |
| Ingress Protection | IP67 |
| Operating Environment | 0–50 °C, 0–90% RH (non-condensing at 30 °C) |
| Compliance | CE, TÜV, FCC Part 15 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Analyzer |
| Model | AQ3700 |
| Measurement Parameters | Total Phosphorus (TP), Total Nitrogen (TN), Chemical Oxygen Demand (COD) |
| Measurement Principle | Spectrophotometry |
| Measurement Range | 0.5–150 mg/L (TP/TN) |
| Accuracy | ≤ ±5% of reading |
| Detection Limit | 0.01 mg/L |
| Resolution | 0.001 mg/L |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable (not online) |
| Model | AQ3700-2 |
| IP Rating | IP67 |
| Operating Temperature | 0–50 °C |
| Relative Humidity | 0–90% RH (non-condensing at 30 °C) |
| Light Source | LEDs at 430, 530, 560, 580, 610, 660 nm |
| Photometric Accuracy | ±2% of full scale |
| Photometric Resolution | ±0.005 Abs |
| Zero Calibration | Deionized water |
| Sample Volume | 10 mL |
| Data Storage | 1000 measurements with timestamp |
| Power | Rechargeable battery (>3000 measurements per charge) |
| Communication | Infrared (IR) |
| Auto Power-Off | 20 min inactivity |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Benchtop/Field Water Quality Analyzer |
| Model | AQ4000 |
| Wavelengths | 420 nm, 520 nm, 580 nm, 610 nm |
| Wavelength Accuracy | ±2 nm |
| Photometric Linearity | ±0.002 A (0–1 A) |
| Photometric Repeatability | ±0.005 A (0–1 A) |
| Photometric Accuracy | ±0.005 A at 1.0 ABS |
| Stray Light | <1.0% at 400 nm |
| Light Source | LED |
| Detector | Photodiode |
| Bandwidth | 10 ± 2 nm |
| Operating Temperature | 0.0–50.0 °C |
| Relative Humidity | ≤90% at 50.0 °C |
| Ingress Protection | IP67 |
| Power Supply | 4 × AA alkaline batteries (2500 h) or lithium batteries (10,000 h) |
| Data Storage | 100 test records |
| Interface | RS232 |
| Sample Cell Compatibility | 13 mm, 16 mm, 24 mm cuvettes |
| Auto-ID™ Support | 13 mm barcoded vials only |
| Preloaded Methods | 190 |
| User-Defined Methods | 10 |
| Display | LCD with unit support (g/L, mg/L, ppm, %T, Abs) |
| Auto-Zero & Blank Correction | Yes |
| Standby Mode | Yes |
| Firmware Update Capability | Yes |
| Memory Retention on Power Loss | Yes |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | AQ4001 COD |
| Instrument Category | Portable |
| COD Range | 0–150 / 0–1500 / 0–15000 mg/L |
| Detection Limits | 1.5 / 15 / 150 mg/L |
| Detector | Photodiode |
| Wavelength Selection | 420, 520, 580, 610 nm (auto-selected) |
| Cuvette Sizes | 13 mm, 16 mm, 24 mm |
| Units | mg/L, ppm, Absorbance, % Transmittance |
| Ingress Protection | IP67 |
| Digestion Unit | AQUAfast COD165 |
| Power Supply | 100–220 V, 50–60 Hz |
| Heating Power | 400 W |
| Weight | 3.6 kg |
| Dimensions (L×W×H) | 155 × 95 × 275 mm |
| Temperature Control | PID microelectronic controller |
| Sensor | Pt100 Class A |
| Digestion Temperatures | 100, 120, 150, 160, 165 °C |
| Digestion Times | 30, 60, 120 min or continuous |
| Ramp Time | 10 min (20 → 165 °C) |
| Temp. Stability | ±0.5 °C |
| Temp. Accuracy | ±1 °C |
| Digestion Well Diameter | 16 mm |
| Number of Wells | 25 |
| Over-Temperature Protection | Yes |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | AutoTration-500 |
| Price | Upon Request |
| Sample Capacity | 48 × 50 mL beakers or 28 × 150 mL beakers |
| Interface | RS232 |
| Operating Voltage | 90–240 V, 50/60 Hz |
| Positioning Accuracy | ±1.0 mm (all axes) |
| X-axis Travel / Accuracy | 510 mm / <0.1 mm |
| Y-axis Travel / Accuracy | 270 mm / <0.1 mm |
| Z-axis Travel / Accuracy / Zero Offset | 160 mm / <0.1 mm / 140 mm |
| Environmental Operating Range | 5–45 °C, 20–80 % RH |
| Certifications | CE |
| Power Consumption | 100 VA |
| Compatible Instruments | Thermo Fisher Orion Star Series Meters |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Dual Star |
| Pricing | Available Upon Request |
| Ammonia Electrode | 9512BNWP |
| Measurement Range | 0.01–17,000 ppm (as N) |
| Temperature Range | 0–50 °C |
| Electrode Slope | −54 to −60 mV/decade (at 25 ± 4 °C, ΔT < ±1 °C between solutions) |
| Repeatability | ±2% |
| Ion Concentration Resolution | 1–3 significant digits |
| pH Range | −2.000 to 19.999 |
| pH Accuracy | ±0.001 |
| ORP Range | ±1999.9 mV |
| Temperature Accuracy | ±0.1 °C |
| Data Storage | 1000 sets with timestamp |
| GLP Compliance | Yes |
| Communication | RS232 and optional USB |
| Enclosure Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | D10P-02 |
| Electrode | 9502BNWP CO₂ Gas-Sensing Electrode |
| CO₂ Range | 4.4–440 ppm |
| pH Operating Range | 4.8–5.2 |
| Temperature Range | 0–50°C |
| Reproducibility | ±2% |
| Electrode Dimensions | 151 mm (L) × 17 mm (body Ø) × 22 mm (cap Ø) |
| Cable Length | 75 cm |
| Dual Channel Meter | pH/ISE Mode |
| pH Range | −2.000 to 19.999 |
| pH Resolution | 0.001 |
| pH Accuracy | ±0.001 |
| ISE Range | 0–19999 (units: ppm, mg/L, M, %, or unitless) |
| ISE Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| ORP Range | ±1999.9 mV |
| Temperature Range | −5 to 105°C |
| Temp Accuracy | ±0.1°C |
| Data Storage | 1000 sets with timestamp |
| GLP Compliance | Yes |
| Interface | Dual RS232 & optional USB |
| IP Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | D10P-06 |
| Instrument Category | Sodium Ion Analyzer |
| Form Factor | Benchtop |
| Measurement Range | 0–19999 (in user-selectable units) |
| Detection Limit | 0.1 ppb (with 8411BNWP electrode and flow cell) |
| Response Time | < 30 s (t₉₀, typical) |
| Accuracy | ±0.1 mV (potential) or ±0.05% of reading (whichever is greater) |
| Temperature Range | −5 to 105 °C |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model | D10P-16 |
| Pricing | Upon Request |
| Electrode | 9616BNWP Ag⁺/S²⁻ Combination Electrode |
| Measurement Range (Ag⁺) | 0.003–32,100 ppm |
| pH Range | 2–12 |
| Temperature Range | 0–80°C (continuous), 80–100°C (intermittent) |
| Reproducibility | ±2% for Ag⁺, ±4% for S²⁻ |
| Electrode Dimensions | 110 mm length, 13 mm body diameter, 16 mm cap diameter, 1 m cable |
| Main Unit | Dual-channel pH/Ion Meter with GLP compliance, RS232 & USB connectivity, IP54 rating, 1000-data storage, 20 method memories |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | D10P-16N |
| Pricing | Upon Request |
| Electrode | 9616BNWP Ag⁺/S²⁻ Combination Electrode |
| Measurement Range (S²⁻) | 0.003–32,100 ppm |
| pH Range | 2–12 |
| Temperature Range | 0–80°C (continuous), 80–100°C (intermittent) |
| Reproducibility | ±4% for S²⁻, ±2% for Ag⁺ |
| Sample Type | Aqueous solutions |
| Electrode Dimensions | 110 mm length × 13 mm body diameter × 16 mm cap diameter |
| Cable Length | 1 m |
| Dual Channel Capability | pH + ISE simultaneously |
| Ion Measurement Range | 0–19,999 units |
| Resolution | 1–3 significant digits |
| Relative Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| Units | ppm, mg/L, M, %, or unitless |
| Calibration Points | 2–6 |
| pH Range | −2.000 to 19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| Temperature Range | −5 to 105°C |
| Temperature Accuracy | ±0.1°C (−5 to 99.9°C) |
| Display | Dual-channel LCD |
| Interfaces | Two BNC, two reference electrode ports, two MiniDIN (for ATC probes) |
| Method Storage | 20 user-defined methods |
| Password Protection | Yes |
| Data Storage | 1,000 readings with timestamp |
| GLP Compliance | Yes (audit trail, calibration history, operator ID) |
| Data Transfer | Bidirectional RS232 |
| Enclosure Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45°C, 5–85% RH (non-condensing) |
| Power | 4×AA batteries or universal AC adapter |
| Dimensions | 9.4 cm (H) × 17.0 cm (W) × 22.4 cm (D) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | D10P-17 |
| Instrument Category | Chloride Ion Analyzer |
| Electrode | 9617BNWP Chloride Composite Electrode |
| Measurement Range (Electrode) | 1.8–35,500 ppm Cl⁻ |
| pH Range | 2–12 |
| Temperature Range | 10–100 °C |
| Repeatability | ±2% |
| Minimum Sample Volume | 3 mL |
| Electrode Dimensions | 110 mm length × 13 mm body diameter × 16 mm cap diameter |
| Cable Length | 1 m |
| Main Unit | Dual Channel pH/ISE Meter |
| ISE Range | 0–19,999 (ppm, mg/L, M, %, or unitless) |
| ISE Resolution | 1–3 significant digits |
| ISE Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| pH Range | −2.000 to +19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| pH Calibration Points | 1–6 |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±0.1 mV or ±0.05% |
| Temperature Range | −5 to +105 °C |
| Temp Resolution | 0.1 °C (−5 to 99.9 °C), 1.0 °C (>99.9 °C) |
| Temp Accuracy | ±0.1 °C |
| Display | Dual-channel LCD |
| Inputs | Two BNC, two reference electrode ports, two MiniDIN (for ATC probes) |
| Method Storage | 20 user-defined methods |
| Password Protection | Yes |
| Data Storage | 1,000 readings with timestamp |
| GLP Compliance | Yes (audit trail, calibration history, operator ID support) |
| Data Interface | Bidirectional RS232, optional USB cable |
| Enclosure Rating | IP54 |
| Safety Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45 °C, 5–85% RH (non-condensing) |
| Power | 4×AA batteries or universal AC adapter |
| Dimensions | 9.4 cm (H) × 17.0 cm (W) × 22.4 cm (D) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | D10P-19 |
| Instrument Category | Multi-Ion Analyzer |
| Electrode | 9719BNWP Potassium Composite Electrode |
| Measurement Range (K⁺) | 0.04–39,000 ppm |
| pH Compatibility | 2.5–11 |
| Temperature Range | 0–40 °C |
| Repeatability | ±2% |
| Electrode Dimensions | 110 mm length × 13 mm body diameter × 16 mm cap diameter |
| Cable Length | 1 m |
| Main Unit Ion Range | 0–19,999 (units: ppm, mg/L, M, %, or unitless) |
| Ion Resolution | 1–3 significant digits |
| Ion Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| pH Range | −2.000 to 19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| Temperature Range (instrument) | −5 to 105 °C |
| Temperature Accuracy | ±0.1 °C |
| Display | Dual-channel LCD |
| Interfaces | Dual BNC, dual reference electrode ports, dual MiniDIN (for ATC probes) |
| Method Storage | 20 methods |
| Data Storage | 1,000 entries with timestamp |
| GLP Compliance | Yes (audit trail, user passwords, method-level access control) |
| Connectivity | RS232 (bidirectional), optional USB cable |
| Enclosure Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Power | 4×AA batteries or universal AC adapter |
| Dimensions | 9.4 cm H × 17.0 cm W × 22.4 cm D |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | D10P-26 |
| Pricing | Available Upon Request |
| Electrode | 9606BNWP Cyanide Ion-Selective Electrode |
| Measuring Range (Cyanide) | 0.2–260 ppm |
| pH Range | 0–14 |
| Temperature Range | 0–80 °C |
| Repeatability | ±2% |
| Electrode Dimensions | Length 110 mm, Body Diameter 13 mm, Cap Diameter 16 mm, Cable Length 1 m |
| Main Unit Ion Concentration Range | 0–19999, Resolution: 1–3 significant digits, Accuracy: ±0.1 mV or ±0.05% (whichever is greater) |
| pH Range | −2.000 to 19.999, Resolution: 0.1/0.01/0.001, Accuracy: ±0.001 pH |
| ORP Range | ±1999.9 mV, Resolution: 0.1 mV |
| Temperature Measurement | −5 to 105 °C, Accuracy: ±0.1 °C |
| Data Storage | 1000 sets with timestamp |
| GLP Compliance | Yes |
| Connectivity | Dual RS232 (bidirectional), optional USB |
| Enclosure Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | D10P-29 |
| Price | Upon Request |
| Electrode | 9629BNWP Copper ISE |
| Measurement Range | 6.4×10⁻⁴ – 6354 ppm Cu²⁺ |
| pH Range | 2–12 |
| Temp. Range | 0–80°C continuous / 80–100°C intermittent |
| Reproducibility | ±4% |
| Electrode Dimensions | 110 mm length, 13 mm body dia., 16 mm cap dia., 1 m cable |
| Instrument Resolution | 1–3 sig. fig. (ion), 0.001 pH |
| Accuracy | ±0.001 pH |
| Calibration Points | 2–6 (ion), 1–6 (pH) |
| Data Storage | 1000 entries with timestamp |
| GLP Compliance | Yes |
| Connectivity | RS232, optional USB |
| IP Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | D10P-32 |
| Pricing | Upon Request |
| Electrode System | 9332BNWP Hardness Half-Cell Electrode + 900100 Single-Junction Reference Electrode |
| Measurement Principle | Potentiometric Ion-Selective Electrode (ISE) Detection of Ca²⁺ and Mg²⁺ |
| pH Range | 7–10 |
| Temperature Range | 0–40 °C |
| Repeatability | ±4% |
| Ion Concentration Range | 6 × 10⁻⁶ M to 1 M (as CaCO₃ equivalent) |
| pH Range (Meter) | −2.000 to 19.999 |
| ORP Range | ±1999.9 mV |
| Temperature Accuracy | ±0.1 °C |
| Data Storage | 1000 entries with timestamp |
| GLP Compliance | Yes (audit trail, password protection, method locking) |
| Connectivity | RS232 and optional USB |
| Enclosure Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | D10P-35 |
| Price | Upon Request |
| Electrode | 9635BNWP Bromide Composite Electrode |
| Bromide Range | 0.2–79,900 ppm |
| pH Range | 0–14 |
| Temperature Range | 0–80 °C |
| Repeatability | ±2% |
| Electrode Dimensions | 110 mm length, 13 mm body diameter, 16 mm cap diameter, 1 m cable |
| Meter Resolution | 1–3 significant digits (ion mode) |
| Accuracy | ±0.001 pH |
| Calibration Points | 2–6 (ion), 1–6 (pH) |
| Method Storage | 20 methods |
| Data Storage | 1,000 records with timestamp |
| GLP Compliance | Yes (audit trail, password protection, user-defined methods) |
| Connectivity | Dual RS232, optional USB |
| IP Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | D10P-48 |
| Price | Upon Request |
| Electrode | 9648BNWP Cd²⁺ Composite Electrode |
| Cd²⁺ Measurement Range | 0.01–11,200 ppm |
| pH Range | 2–12 |
| Temp. Range (Continuous) | 0–80°C |
| Temp. Range (Intermittent) | 80–100°C |
| Reproducibility | ±4% |
| Electrode Dimensions | 110 mm (L) × 13 mm (body Ø) × 16 mm (cap Ø) |
| Cable Length | 1 m |
| Ion Concentration Resolution | 1–3 significant digits |
| Relative Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| pH Range | −2.000 to 19.999 |
| pH Accuracy | ±0.001 |
| ORP Range | ±1999.9 mV |
| Temp. Accuracy | ±0.1°C |
| Data Storage | 1000 entries with timestamp |
| GLP Compliance | Yes |
| Communication | RS232 (bidirectional), optional USB |
| Enclosure Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | D10P-53 |
| Pricing | Upon Request |
| ISE Electrode | 9653BNWP |
| Iodide Measurement Range | 0.005–127,000 ppm |
| pH Range | 0–14 |
| Temperature Range | 0–80 °C |
| Reproducibility | ±2% |
| Electrode Dimensions | 110 mm length × 13 mm body diameter × 16 mm cap diameter |
| Cable Length | 1 m |
| Dual-Channel Meter Resolution | 1–3 significant digits |
| Relative Accuracy (Ion) | ±0.1 mV or ±0.05% (whichever is greater) |
| Ion Units | ppm, mg/L, M, %, or unitless |
| Calibration Points | 2–6 |
| pH Range | −2.000 to 19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| Temperature Range | −5 to 105 °C |
| Temp Accuracy | ±0.1 °C |
| Data Storage | 1000 sets with timestamp |
| GLP Compliance | Yes |
| Connectivity | RS232 (bidirectional), optional USB |
| Enclosure Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Power | 4×AA batteries or universal AC adapter |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | D10P-82 |
| Price | Upon Request |
| Electrode | 9682BNWP Lead Ion-Selective Electrode |
| Measurement Range (Electrode) | 0.2–20,700 ppm Pb²⁺ |
| pH Range | 4–7 |
| Temperature Range | 0–80°C (continuous), 80–100°C (intermittent) |
| Repeatability | ±4% |
| Sample Type | Aqueous solutions |
| Electrode Dimensions | 110 mm length, 13 mm body diameter, 16 mm cap diameter |
| Cable Length | 1 m |
| Instrument Resolution (Ion Mode) | 1–3 significant digits |
| Ion Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| Ion Units | ppm, mg/L, M, %, or unitless |
| Calibration Points | 2–6 |
| pH Range | −2.000 to 19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| Temperature Range | −5 to 105°C |
| Temp. Accuracy | ±0.1°C |
| Display | Dual-channel LCD |
| Inputs | Two BNC, two reference electrode, two MiniDIN (for ATC probes) |
| Method Storage | 20 methods |
| Password Protection | Yes |
| Data Storage | 1000 data sets with timestamp |
| GLP Compliance | Yes (audit trail, user ID, calibration history) |
| Connectivity | RS232 (bidirectional), optional USB cable |
| Enclosure Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45°C, 5–85% RH (non-condensing) |
| Power | 4×AA batteries or universal AC adapter |
| Dimensions | 9.4 × 17.0 × 22.4 cm (H×W×L) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Laboratory BOD Analyzer |
| Model | 310D-24A |
| Measurement Principle | Polarographic & Luminescent (RDO) Dissolved Oxygen Detection |
| DO Range (Polarographic) | 0–90 mg/L |
| DO Resolution (Polarographic) | 0.1 / 0.01 mg/L |
| DO Accuracy (Polarographic) | ±0.2 mg/L |
| DO Range (RDO) | 0–50 mg/L |
| DO Accuracy (RDO) | ±0.1 mg/L (0–8 mg/L), ±0.2 mg/L (8–20 mg/L), ±10% of reading (20–50 mg/L) |
| Saturation Range (Polarographic) | 0–600% |
| Saturation Range (RDO) | 0–500% |
| Saturation Accuracy | ±2% |
| Temperature Range | 0–50 °C |
| Temperature Accuracy | ±0.1 °C |
| Atmospheric Pressure Compensation | 450.0–850.0 mmHg |
| Salinity Compensation | 0–45 ppt (automatic with conductivity module or manual) |
| Calibration Modes | Saturated air/water, Winkler titration, zero-oxygen water |
| Data Storage | 2000 GLP-compliant entries |
| Interface | 9-pin mini-DIN DO probe port, RS232, USB |
| Power | AC adapter (100–240 V AC) or 4 × AA batteries |
| IP Rating | IP54 |