Thermo Fisher
Filter
Showing 181–210 of 1004 results
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | GENESYS™ 180 UV-Vis Spectrophotometer (Domestically Manufactured) |
| Quotation | Upon Request |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 2 nm |
| Optical Design | Double-Beam |
| Photometric Accuracy | ±0.002 A at 0.5 A, ±0.004 A at 1.0 A, ±0.008 A at 2.0 A |
| Photometric Range | –2 A to +3.5 A |
| Photometric Display Range | –3 A to +5 A |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ±0.2 nm |
| Wavelength Data Interval | 0.1, 0.2, 0.5, 1, 2, or 5 nm |
| Baseline Flatness | ±0.002 A |
| Stray Light | <1.0%T @ 198 nm (KCl), <0.05%T @ 220 nm (NaI), <0.03%T @ 340 nm (NaNO₂) |
| Noise (RMS, 60 readings @ 500 nm) | ≤0.00020 A at 0 A, ≤0.00030 A at 1 A, ≤0.00040 A at 2 A |
| Detector Type | Dual Silicon Photodiodes |
| Display | 7-inch HD color touchscreen (800 × 1280 px), tilt-adjustable |
| Sample Compartment | Standard 8-cell changer with swappable sample tower |
| Optional Accessories | 4-cell long-path changer (up to 100 mm pathlength), Peltier-controlled single-cell holder (20–60 °C), syringe autosampler, fiber optic probe coupler |
| Connectivity | Dual USB-A ports, Ethernet, Wi-Fi adapter support (optional), USB printing support |
| Dimensions (L × W × H) | 35.5 × 38.5 × 19.5 cm |
| Weight | 7.5 kg |
| Lamp Lifetime | >5 years (3-year limited warranty) |
| Power Supply | Auto-ranging AC/DC adapter (100–240 V, 50/60 Hz) |
| Scan Speed | Slow / Medium / Fast — up to 1600 nm/min |
| Compliance | Designed and validated per ISO 9001 manufacturing standards |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin Category | Domestically Manufactured |
| Model | GENESYS™ 40/50 Vis/UV-Vis Spectrophotometer (Domestically Manufactured) |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Thermo Fisher Genexus™ Integrated Sequencer |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Manufacturer | Thermo Fisher Scientific |
| Model | GenPure Pro |
| Purified Water Grade | ASTM Type I / ISO 3696 Grade 1 |
| Resistivity | 18.2 MΩ·cm at 25°C |
| TOC | 1–5 ppb |
| Microbial Count | < 0.001 EU/mL |
| Particles (>0.1 µm) | < 1 particle/mL |
| RNase | ≤ 0.003 ng/mL |
| DNase | ≤ 0.4 pg/µL |
| UV Wavelength | 185 nm / 254 nm |
| Conductivity Sensor Electrode Constant | 0.01 cm⁻¹ |
| Temperature Accuracy | ±0.1°C |
| Dispensing Accuracy | ±0.5% (0.01–65 L) |
| Data Logging | Last 4 weeks of system errors |
| Compliance | ASTM D1193, ISO 3696, CLSI, USP <645>, GLP |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | CTS Xenon |
| High Voltage Range | 2500 V |
| Low Voltage Range | 500 V |
| Pulse Count | 1–10 |
| Pulse Duration | 1–30 ms |
| Output Waveform | Square Wave |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Laboratory-Scale Twin-Screw Extruder |
| Model | Eurolab 16 |
| Screw Diameter | 16 mm |
| L/D Ratio | 25:1 to 40:1 (modular) |
| Motor Power | 1.25 kW or 2.5 kW |
| Speed Range | 50–1000 rpm |
| Max Operating Pressure | 200 bar |
| Barrel Temperature Zones | 6–10 |
| Max Barrel Temperature | 350 °C (optional 450 °C) |
| Throughput | 0.5–5 kg/h |
| Drive System | PLC-controlled servo motor with real-time torque & temperature monitoring |
| Control Interface | Color LCD touchscreen with embedded HAAKE PolyLab software |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Model | HAAKE Falling Ball |
| Instrument Type | Falling Ball Viscometer |
| Viscosity Range | 0.5 – 100,000 mPa·s |
| Temperature Range | −1 °C to +26 °C |
| Repeatability | < 0.5 % |
| Reproducibility | < 1 % |
| Measurement Tube Material | Borosilicate Glass (Tubes 1, 2, G) |
| Ball Materials | Nickel–Iron Alloy (Balls 3, 4, 5, 6) |
| Compliance | DIN 53015, ISO 120587 |
| Optional Accessories | Digital Stopwatch, Ball G (for gas viscosity), PT100 Temperature Sensor for HAAKE D50 Circulator |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Air Bearing |
| Minimum Rotational Speed | 1×10⁻⁸ rpm |
| Frequency Range | 1×10⁻⁶ – 100 Hz |
| Maximum Rotational Speed | 4500 rpm |
| Maximum Torque | 200 mNm |
| Torque Resolution | 0.1 nNm |
| Angular Displacement Resolution | 12 nrad |
| Normal Force Range | 0.01 – 50 N |
| Normal Force Resolution | 0.001 N |
| Vertical Travel | 240 mm |
| Gap Resolution | 0.5 µm |
| Minimum Vertical Speed | 0.02 µm/s |
| Maximum Vertical Speed | 20 mm/s |
| Temperature Range (with optional modules) | −150 °C to +600 °C |
| Dimensions (W×D×H) | 600 × 600 × 890 mm |
| Weight | 59 kg |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | MiniJet Pro |
| Maximum Injection Pressure | 1200 bar |
| Compressed Air Supply Pressure (Max) | 10 bar |
| Barrel Temperature Range | Up to 400 °C |
| Mold Temperature Range | Up to 250 °C |
| Sample Mass Capacity | 3–5 g per shot |
| Control Interface | Digital LCD Controller with Parameter Storage |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | 567-0021 |
| Configuration | Import |
| Distribution Type | Authorized Distributor |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Torque Rheometer |
| Model | PolyLab OS |
| Motor Bearing | Screw-driven |
| Minimum Speed | 1 rpm |
| Frequency Range | 0.1–115 rad/s |
| Maximum Speed | 250 rpm (up to 1100 rpm optional) |
| Maximum Torque | 120 mNm (dual-range: 120/400 Nm) |
| Torque Resolution | 0.01 / 0.1 Nm |
| Temperature Range | Up to 400 °C (optional 450–500 °C) |
| Heating/Cooling | Electric heating + compressed air cooling |
| Control Zones | 7–10 independent temperature zones |
| Pressure Capability | Up to 700 bar |
| Barrel Design | Modular, horizontally split |
| Screw Configurations | Single-screw (Ø19.05 mm), Conical counter-rotating twin-screw (Ø31.8/20 mm), Parallel co-rotating twin-screw (Ø16/24 mm), Banbury-type mixer (120/625 cm³ chamber volume) |
| Power Supply | 7 kW / 16 kW |
| L/D Ratios | 10:1, 25:1, 33:1 (single-screw) |
| 25 | 1 to 40:1 (twin-screw) |
| Extrusion Capacity | ~5 kg/h (polymer-dependent) |
| Compliance | DIN 1.4301 stainless steel (mixer), DIN 1.8550 nitrided steel (screws/barrels) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | PolyLab QC |
| Instrument Category | Torque Rheometer |
| Drive Bearing | Single-screw configuration |
| Minimum Speed | 1 rpm |
| Frequency Range | 1–21 rad/s |
| Maximum Speed | 200 rpm |
| Maximum Torque | 300 N·m |
| Torque Resolution | 0.1 N·m |
| Torque Accuracy | ±0.15% of full scale |
| Temperature Range | Up to 450 °C (heating via electric cartridge heaters |
| Screw Material | Nitrided stainless steel (DIN 1.8550) |
| Chamber Material | Stainless steel (DIN 1.4301) |
| Mixer Chamber Volume | 120 cm³ or 625 cm³ |
| Screw Diameter | 19.05 mm (single-screw unit) / 31.8 mm & 20 mm (conical counter-rotating twin-screw unit) |
| Screw L/D Ratio | 25 |
| Screw Length | 300 mm |
| Gear Ratio | 3:2 |
| Maximum System Pressure | 700 bar |
| Power Rating | 4 kW |
| Control Interface | USB or optional Ethernet (LAN) |
| Software Platform | HAAKE PolySoft v7.x (Windows-based) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported |
| Model | Process 11 |
| Drive Motor Power | 1.5 kW |
| Screw Diameter | 11 mm |
| L/D Ratio | 40 |
| Speed Range | 10–1000 rpm |
| Barrel Material | Nitrided Steel 1.7365 (EN 40B) |
| Max Operating Temperature | 350 °C (optional 450 °C) |
| Max System Pressure | 100 bar (with pressure monitoring) |
| Heating Zones | 7 × 5D electric heating (optional water cooling) |
| Dimensions (L×W×H) | 820 × 480 × 410 mm |
| Weight | 55 kg |
| Sample Requirement | ~20 g |
| Throughput | up to 2.5 kg/h |
| Barrel Opening | Horizontal split, two-piece design |
| Control Interface | Integrated color touchscreen |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Country of Origin | Imported |
| Model | TSE 24 |
| Price | Upon Request |
| Screw Diameter | 24 mm |
| L/D Ratio | up to 40:1 |
| Motor Power | 5.5–11 kW |
| Max Speed | 500–1000 rpm |
| Max Temperature | 400 °C |
| Max Pressure | 100 bar |
| Temperature Zones | 7–10 independently controlled |
| Throughput | 2–30 kg/h |
| Drive Type | DC or AC servo motor |
| Barrel Construction | Horizontal split, hinged modular segments |
| Screw Design | Intermeshing co-rotating, fully configurable |
| Control Interface | 10.4" color touchscreen with HAAKE PolyLab OS software |
| Data Export | Real-time CSV/Excel export via Ethernet/USB |
| Compliance | CE, ISO 9001, compliant with GLP/GMP documentation requirements for process development |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Rotational Viscometer |
| Model | VT C / VT D / VT E |
| Viscosity Range | 15 – 40,000,000 mPa·s |
| Accuracy | ±1 % FSD |
| Repeatability | 0.2 % FSD |
| Speed Range | 0.01 – 200 rpm |
| Compliance | ISO 2555, ASTM D1084/D2196/D2556/D2983/D3232, BS 6075/5350 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Viscotester D (R-Version) |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Rotational Viscometer |
| Model | HAAKE Viscotester D |
| Viscosity Range | 15 – 40,000,000 mPa·s |
| Compliance | ISO 2555 |
| Rotor Geometry | Standard Spindle (e.g., LV, RV, HA, HB series) |
| Shear Rate Range | Dependent on spindle geometry and rotational speed (typically 0.1–1000 s⁻¹) |
| Accuracy | ±1% of full scale (per ISO 2555 calibration requirements) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Rotational Rheometer |
| Motor Bearing | Air-bearing-free (direct-drive torque sensor) |
| Minimum Angular Velocity | 0.001 rad/s |
| Maximum Angular Velocity | 157 rad/s (≈1500 rpm) |
| Torque Range | 0.2–100 mN·m |
| Torque Resolution | 0.002 mN·m (0.2% of full scale) |
| Oscillation Frequency Range | 0.01–100 Hz (with optional oscillatory module) |
| Temperature Control | Peltier-based, -10 to +130 °C (with coaxial cylinder or cone/plate geometry) |
| Geometry Auto-Recognition | Yes |
| Interface | 7″ capacitive touchscreen + USB host/device + Ethernet |
| Software | HAAKE RheoApp (standalone on USB drive) and HAAKE RheoWin (PC-based, GLP-compliant) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Harshaw TLD 4500 |
| Instrument Category | Radiation Dosimetry System |
| Instrument Form Factor | Benchtop (Not Portable — Corrected per Technical Specification) |
| Measured Radiation Types | Photons (>1 keV), Neutrons (thermal to 100 MeV), Electrons (>70 keV) |
| Dynamic Range | 7 decades |
| Readout Time | <35 s (2-element card), <60 s (4-element card) |
| Linearity | ±1% deviation |
| Reference Light Stability | <1% variation over 10 consecutive reads |
| Glow Curve Heating Profile | Preheat 0–100 s, Ramp Rate 1–30 °C/s, Max Temp 300 °C (Teflon), 400 °C (Kapton), 600 °C (metal disk) |
| Dose Range (metal-disk heating) | 10 µGy–1 Gy (linear), 1–20 Gy (supralinear) |
| Reusability | 500 cycles (TLD-100 chips), 50 cycles (extremity rings) |
| Operating Temperature | 0–40 °C |
| Dimensions | 370 H × 460 W × 500 D mm |
| Weight | 35 kg |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Laboratory-Based TLD Reader |
| Model | Harshaw TLD 5500 |
| Detector Type | Cooled Photomultiplier Tube (PMT) |
| Sample Capacity | Up to 50 TLD chips per cycle |
| Heating Method | Gas-Heated Linear Ramp (TTP) |
| Max Temperature | 600 °C |
| Linearity | ±1% deviation |
| Dynamic Range | 7 decades |
| Preheat Time | 30 min |
| High Voltage Range | 500–1200 V |
| HV Stability | ±0.005% |
| Dose Units | nC, µGy, mGy, Gy, mrad, mrem, µSv, mSv, Sv |
| Dark Current Equivalent | <50 mGy (Cs-137) |
| MTBF | >10,000 hours |
| Operating Temp | 0–40 °C |
| Storage Temp | −10–60 °C |
| Compliance | Designed for ISO/IEC 17025-accredited dosimetry laboratories |
| Software | Harshaw TLD Analysis Suite with audit trail and 21 CFR Part 11 readiness |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Thermoluminescent Dosimeter (TLD) Reader |
| Model | Harshaw TLD 6600 |
| Detector Type | TLD Reader |
| Radiation Types Measured | Photons (X-rays, γ-rays), Neutrons |
| Measurement Scope | Personal Dose, Environmental Dose |
| Linear Dose Range | Up to 20 Sv |
| Compliance | IEC 61066, ISO 14146, ANSI N13.32 |
| Operating Mode | Benchtop (not portable — corrected per technical specification) |
| Calibration | Automated, Traceable to NIST Standards |
| Quality Control | Built-in QC routines with pass/fail reporting |
| Light Sensitivity | Immune to ambient light interference (non-OSL design) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported |
| Model | 250i |
| Temperature Range & Accuracy | 3 °C to 55 °C |
| Temperature Uniformity | ±0.1 °C |
| Humidity Control (at 37 °C) | >93% RH |
| Chamber Capacity | 255 L |
| O₂ Control Range | 1–21% (hypoxic) and 5–90% (hyperoxic) |
| Sterilization Cycle | 180 °C dry-heat, 6-log bioburden reduction |
| Air Filtration | ISO 5 certified HEPA, full-chamber air exchange every 60 s |
| Recovery Time (after door opening) | ≤10 min for all parameters |
| Humidity Recovery Rate | 5× faster than conventional water pan systems |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Manufacturer | Thermo Fisher Scientific |
| Model | 51026280 |
| Temperature Range & Accuracy | Ambient +3°C to 55°C |
| Temperature Uniformity | ±0.5°C |
| Humidity Control | >90% RH at 37°C |
| Chamber Volume | 150 L (5.3 cu. ft.) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Model Numbers | 51030476, 51030286, 50145503, 50145517 |
| Temperature Range & Accuracy | Ambient +3°C to 55°C |
| Temperature Uniformity | ±0.5°C |
| Humidity Control | >93% RH at 37°C |
| Capacity | 165 L (5.8 cu. ft.) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | BK 6160 |
| Capacity | 166 L |
| Temperature Range | 0 °C to 50 °C |
| Humidity Range | Up to 90% RH (with optional humidity pan) |
| Construction | Seamless stainless-steel interior with radius corners |
| Cooling/Heating System | External jacketed water bath with external air mixing and recirculation |
| Control System | Programmable temperature controller with ramp-soak and day/night light cycle simulation capability |
| Compliance | Designed for ISO 17025-compliant environmental testing labs |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Model | HERAfreeze (HFU & HFC Series) |
| Configuration | Upright & Horizontal |
| Temperature Range | –50 °C to –86 °C |
| Capacities | 220–630 L |
| Internal Insulation | 150 mm Polyurethane Foam |
| Control Precision | ±2.5 K |
| Sample Temperature Stability | <±0.1 K |
| Power Consumption | 11.2–18.8 kWh/24h |
| Noise Level | <56 dB(A) |
| Door Seal | Dual-layer Magnetic Silicone + PVC with Anti-condensation Heating |
| Optional Systems | CO₂ Backup Cooling, Water-Cooled Condenser |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model Numbers | 51029701, 51029702, 51029703, 51029704 |
| Instrument Category | Horizontal Laminar Flow Clean Bench |
| User Configuration | Single-Sided Operation |
| Internal Width Options | 900 mm, 1200 mm, 1500 mm, 1800 mm |
| Standard Work Height | 650 mm |
| Extended Work Height | 950 mm |
| Compliance | GOST, CE (2006/95/EC |
| 2006/121/EC), EN 61010-1 | 2011, EN 61326:2006 |
| Drive System | Brushless DC Motor |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | ECO 0.9 |
| Airflow Type | Vertical Laminar Flow |
| Cleanliness Class | ISO Class 5 (100-level) |
| Noise Level | <55 dB(A) |
| Rated User Capacity | 2 operators |
| Pre-filter | EN779 G3 coarse-to-medium dust filter |
| HEPA Filter | EN1822 H14 (≥99.995% @ 0.3 µm) |
| Work Surface Options | Melamine or 316 stainless steel |
| UV Lamp | Optional |
| Illumination | >1000 lx |
| Power Consumption | 270 W |
| Air Velocity Range | 0.15–0.25 m/s (low mode), 0.36–0.45 m/s (high mode) |
| Compliance | CE marked per 2006/95/EC (LVD), 2004/108/EC (EMC), 2011/65/EC (RoHS), 2006/121/EC (REACH) |
| EN 61010-1 | 2011, EN 61326:2006 |
| Certifications | GOST-R certified for CIS markets |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model Numbers | 51022481, 51022482, 51022483, 51022484 |
| External Dimensions (L×W×H) | 1100–2000 mm |
| Internal Dimensions (L×W×H) | 900–1800 mm |
| HEPA Filter Efficiency at MPPS | ≥99.995% |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Equipment |
| Model | IMP400 |
| Temperature Range | 5–70°C |
| Capacity | 178 L (benchtop) / 381 L (floor-standing with casters) |
| Temperature Uniformity | ±0.3°C at 20°C |
| Temperature Stability | ±0.1°C at 20°C |
| Power Consumption | 80 Wh/h (benchtop) / 150 Wh/h (floor-standing) |
| Insulation | CFC-free & HFC-free polyurethane foam |
| Door Heating | Intelligent energy-controlled glass door heating |
| Programming | Up to 10 programs, each with 10 steps (ramp, soak, cool-down) |
| Safety Class | Class 2.0 per DIN 12880 |
| Chamber Material | Stainless steel 1.4301 (ASTM 304), radius-cornered interior |
| Access Port | Standard Ø42 mm (1.65 in) for data monitoring probes |