Thermo Fisher
Filter
Showing 31–60 of 376 results
| Brand | Thermo Fisher |
|---|---|
| Origin | Mexico |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Instrument |
| Model | Aquion |
| Pump Pressure Rating | 5000 psi |
| Flow Rate Range | 0.00–5.00 mL/min |
| Eluent Flow Rate | 0.00–5.00 mL/min |
| Maximum Operating Pressure | 5000 psi |
| Column Oven Temperature Range | 30–60 °C |
| Temperature Reproducibility | ±0.5 °C |
| Eluent Concentration Range | 0.1–100 mM (dependent on eluent chemistry) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Mexico |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | Aquion RFIC |
| Instrument Type | Laboratory |
| Maximum Pump Pressure | 5000 psi |
| Flow Rate Range | 0.00–5.00 mL/min |
| Eluent Flow Rate Range | 0.00–5.00 mL/min |
| Maximum Operating Pressure | 5000 psi |
| Operating Temperature Range | Ambient +5°C to 60°C |
| Temperature Reproducibility | ±0.05°C |
| Eluent Concentration Range | 0.1–100 mM |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | AS-AP |
| Instrument Category | Multifunctional Autosampler |
| Sample Capacity | Up to 1152 positions (microtiter plate) / 81 vials (10 mL) |
| Injection Cycle Time | <30 s for 5 µL injection |
| Precision | RSD <0.3% |
| Fluidic Path | Full PEEK™ construction |
| Needle Design | Moving-needle architecture |
| Temperature Control | 4–60 °C sample tray cooling |
| Integrated Pre-injection Analysis | Conductivity & pH measurement |
| Automation Capabilities | Automated internal standard addition, on-line dilution, pre-column derivatization, matrix removal, analyte preconcentration, fraction collection, re-injection, and sample ejection |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | AS-DV |
| Instrument Category | Multifunctional Autosampler |
| Fluidic Path Material | PEEK™ |
| Compatible Systems | All Dionex ICS Ion Chromatography Systems |
| Sample Vial Capacity | 5.0 mL and 0.5 mL polymer vials |
| Valve Options | Optional 6-port or 10-port switching valves |
| Software Control | Thermo Scientific Chromeleon CDS (v7.3 or later) |
| Audit Trail & Electronic Signatures | Compliant with 21 CFR Part 11 |
| Dual-IC System Operation | Supported |
| Sample Overlap Injection | Enabled |
| Filtration Option | Available with filter cap accessory |
| Detection Limit Enhancement | Via automated on-line preconcentration and matrix elimination |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | AS-HV |
| Instrument Category | Multifunctional Autosampler |
| Sample Capacity | Up to 250 mL |
| Syringe/Pump Options | Syringe, Peristaltic, or Piston Pump |
| Rack Compatibility | 21-position (50 mL vials, 30 mm O.D.), 24-position (26 mL vials, 24 mm O.D.), 40-position (15 mL vials, 20 mm O.D.), 60-position (10 mL vials, 16 mm O.D.), or 21-position (60/40 mL ASE™ Collection Vials) |
| Fluid Path Material | All-PEEK™ |
| Loading Mode | Programmable “push” or “pull” |
| Arm Motion | High-speed, high-precision robotic positioning |
| Footprint | Compact benchtop design |
| Optional Integration | Dionex AutoPrep™ system, RFIC™-ESP platform, trace analysis cover |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ASE 150 |
| Instrument Type | Solid-Phase Extraction System (ASE) |
| Operating Temperature Range | Up to 200 °C |
| Maximum Pressure | 1500 psi |
| Pump Flow Rate | 70 mL/min |
| Sample Capacity | 1–100 g |
| Extraction Cell Volumes | 1, 5, 10, 22, 34, 66, and 100 mL |
| Solvent Consumption Reduction | 50–90% vs. Soxhlet or Ultrasonic Extraction |
| Fluid Path Material | Dionium™ (chemically inert, acid- and base-resistant) |
| Integrated Filtration | On-line filtration and in-cell cleaning capability |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | ASE 350 |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model | ASE+Rocket |
| Instrument Type | Accelerated Solvent Extractor (ASE) with Integrated Rotary Evaporation |
| Price Range | USD 42,000 – 70,000 (FOB US Port) |
| Extraction Principle | High-Temperature/High-Pressure Static-Dynamic Solvent Extraction |
| Brand | Thermo Fisher |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC-manufactured) |
| Model | Dionex Easion Ion Chromatography System |
| Instrument Type | Laboratory Benchtop IC System |
| Application Scope | General-Purpose Anion/Cation Analysis |
| Pump Pressure Range | 0–35 MPa |
| Flow Rate Range | 0.00–5.00 mL/min (single-pump-head design) |
| Maximum Operating Pressure | 10 MPa |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | ICS-1100 |
| Instrument Type | Laboratory Benchtop System |
| Maximum Pump Pressure | 6000 psi |
| Operating Pressure Range | Up to 5000 psi |
| Column Oven Temperature Range | 4–40 °C |
| Eluent Concentration Range | 0–100 mM (KOH), adjustable per eluent chemistry |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ICS-1600 |
| Instrument Type | Laboratory Benchtop System |
| Maximum Pump Pressure | 6000 psi |
| Operating Pressure Range | Up to 5000 psi |
| Column Oven Temperature Range | 4–40 °C |
| Eluent Concentration Range | 0–100 mM KOH (varies with eluent chemistry) |
| Eluent Generation Compatibility | RFC-30 Electrolytic Eluent Generator |
| Suppressor Type | AutoSuppression™ Electrolytic Micro-Membrane Suppressor |
| Software Platform | Chromeleon™ 7.3 or later |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Instrument |
| Model | ICS-4000 |
| Pump Pressure Rating | 6000 psi |
| Flow Rate Range | 0.001–0.100 mL/min |
| Eluent Flow Rate | 0.001–0.100 mL/min |
| Maximum Operating Pressure | 6000 psi |
| Operating Temperature Range | 10°C–40°C |
| Temperature Reproducibility | ±0.2°C |
| Eluent Concentration Range | 0–100 mM (KOH), dependent on eluent chemistry |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | ICS-4000 CD |
| Instrument Category | Laboratory Benchtop Ion Chromatograph Detector |
| Detection Principle | Suppressed/Unsuppressed Conductivity Detection |
| Dynamic Range | 0–15,000 µS/cm |
| Cell Volume | 0.02 µL (Capillary Mode) |
| Temperature Control | Independent, Microprocessor-Regulated Detector Thermostat |
| Interface | Plug-and-Play Auto-Recognition via Chromeleon™ CDS |
| Mounting | Tool-Free Snap-In Mechanism |
| Compatible Configurations | Series or Parallel Dual-Detector Setup |
| Flow Path Options | Capillary, Analytical (Standard-Bore and Microbore) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ICS-5000+ CD |
| Application Environment | Laboratory-Based Ion Chromatography System |
| Configuration Options | Capillary and Analytical (Standard-Bore & Microbore) Flow Paths |
| Detector Architecture | Digital Signal Processing (DSP)-Enabled, Thermally Stabilized Conductivity Detection Module |
| Dynamic Range | 0–15,000 µS/cm |
| Cell Volume (Capillary Mode) | 0.02 µL |
| Installation Interface | Tool-Free Snap-In Mounting with Auto-Detection via Chromeleon™ CDS |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ICS-5000+ ED |
| Application | Laboratory-Based Ion Chromatography |
| Detection Principle | Pulsed Amperometric Detection (PAD), DC Amperometry, Integrated Amperometry, and Cyclic Voltammetry |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ICS-600 |
| Instrument Type | Laboratory |
| Pump Pressure Rating | 5000 psi |
| Flow Rate Range | 0.00–5.00 mL/min |
| Eluent Flow Rate | 0.00–5.00 mL/min |
| Maximum Operating Pressure | 5000 psi |
| Operating Temperature Range | Ambient +5°C to 60°C |
| Temperature Reproducibility | ±0.1°C |
| Eluent Concentration Range | 0–100 mM (KOH), dependent on eluent chemistry |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ICS-6000 |
| Pump Pressure Rating | 6000 psi |
| Flow Rate Range | 0.001–22.4 mL/min |
| Eluent Flow Rate Range | 0.001–22.4 mL/min |
| Maximum Operating Pressure | 10 MPa |
| Operating Temperature Range | 10°C–70°C |
| Temperature Reproducibility | ±0.05°C |
| Eluent Concentration Range | 0.1–200 mM |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ICS-900 Starter Line IC System |
| Pump Pressure Rating | 6000 psi |
| Maximum Operating Pressure | 5000 psi |
| Operating Temperature Range | 4–40 °C |
| Eluent Concentration Range | 0–100 mM (KOH), dependent on eluent chemistry |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Instrument |
| Model | ICS-VWD |
| Wavelength Range | 190–900 nm |
| Data Acquisition Rate | Up to 100 Hz |
| Light Sources | Deuterium Lamp + Tungsten Lamp |
| Software Control | Thermo Scientific Dionex Chromeleon Chromatography Data System (CDS) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | Dionex Inuvion |
| Instrument Type | Laboratory |
| Application Scope | General-purpose |
| Pump Pressure Rating | 5000 psi |
| Flow Rate Range | 0–5 mL/min |
| Maximum Operating Pressure | 5000 psi |
| Operating Temperature Range | 10–60 °C (±0.5 °C) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Dionex Inuvion |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | DXR3xi |
| Instrument Category | Confocal Micro-Raman Spectrometer |
| Spectral Range | 50–9000 cm⁻¹ |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution | 350 nm |
| Excitation Wavelength | 455 nm (optional lasers available) |
| Spectral Reproducibility | ±0.1 cm⁻¹ |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | EPD MK2 |
| Instrument Category | Dose/Dose Rate Meter |
| Form Factor | Portable |
| Measured Radiation Types | X-ray, γ-ray, and β-particle radiation |
| Detector Type | Multi-stage solid-state detector |
| Measurement Quantities | Ambient dose equivalent H*(10), personal dose equivalent Hp(10) (deep/body), and Hp(0.07) (shallow/skin) |
| Compliance Standards | IEC 61283, IEC 61526, ANSI N13.11, ANSI N13.27, ANSI N42.20 |
| Data Retention | 10 years without battery power |
| Power Supply | Two AA 1.5 V alkaline batteries (8 weeks continuous operation) or one 3.6 V lithium battery (5 months continuous operation) |
| Communication Interface | High-speed infrared (IR) port |
| Alarm Capability | Configurable dose and dose rate thresholds with audible alert |
| Memory Security | Password-protected dose log storage |
| Certification Status | Only electronic personal dosimeter to pass all IAEA 2007 performance tests |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | EPD-N2 |
| Instrument Category | Dose Rate Meter / Personal Dosimeter |
| Form Factor | Portable |
| Radiation Types Measured | Gamma and Neutron |
| Detector Technology | Multi-stage Solid-State Detector |
| Energy Range | 25 keV – 10 MeV (photons), Thermal neutrons – 15 MeV (neutrons) |
| Dose Quantity Displayed | Ambient and Personal Dose Equivalent Hp(10) |
| Compliance | IEC 61526 Ed. 4.0 (2018), ANSI N42.20, ISO 15265:2022 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Evolution Pro |
| Instrument Configuration | Double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | Selectable 0.5, 1.0, 1.5, 2.0, or 4.0 nm |
| Wavelength Accuracy | ±0.20 nm at 546.07 nm (Hg emission line) |
| Wavelength Repeatability | Standard deviation <0.05 nm over 10 consecutive measurements |
| Stray Light | ≤0.4% T at 198 nm (KCl), ≤0.032% T at 220 nm (NaI), <0.01% T at 340 nm (NaNO₂) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Exactive™ GC Orbitrap™ GC-MS |
| Instrument Type | Orbitrap Mass Spectrometer |
| Chromatography Type | Gas Chromatography |
| Mass Range | Not Specified |
| Resolution | 60,000 (FWHM) at m/z 200 |
| Sensitivity | <6 fg OFN (Octafluoronaphthalene) |
| Scan Speed | Not Specified |
| Ionization Modes | Electron Ionization (EI) / Chemical Ionization (CI) |
| Ion Source | Thermo Scientific™ ExtractaBrite™ with Vacuum Lock |
| Brand | Thermo Fisher |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | EXTREVA™ ASE™ Accelerated Solvent Extractor |
| Instrument Type | Solid-Liquid Extraction (not Liquid-Liquid) |
| Temperature Range | 40–200 °C |
| Pressure Range | 200 bar (corrected from erroneous "200 Pa") |
| Extraction Cell Volumes | 1, 5, 10, 22, 34, 66, and 100 mL |
| Extraction Time | 2–300 min |
| Dimensions (W×D×H) | 100 × 65.2 × 86.6 cm |
| Sample Capacity | Dual trays, 16 positions total |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | F6000-60 / F30400-60 |
| Temperature Range | 100–975 °C |
| Chamber Volume | 15 L or 45 L |
| Air Flow Control | 0–80 L/min (adjustable via front-mounted flowmeter) |
| Temperature Stability at 750 °C | ±3 °C |
| Heating Rate | 8 °C/min (≤500 °C), 6 °C/min (500–750 °C) |
| Compliance | ASTM D3174 |
| Gas Inlet Ports | 1 × 0.95 cm thermocouple port, 1 × 0.635 cm or 0.876 cm soft-hose barb for inert gas supply |
| Control Options | B1 (single-setpoint), C1 (8-segment single program), D1 (16-segment × 4 programs, RS232 interface) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | FB1300 / FB1400 |
| Temperature Range | 100–1100 °C |
| Chamber Volume | 1.3 L / 2.1 L |
| Insulation | Ceramic Fiber |
| Heating Element Layout | Top + Dual Side Mounting |
| Door Operation | Downward-Opening Hinged Door |
| Safety Interlock | Integrated Door-Activated Power Cut-off |
| Thermocouple Fault Protection | Automatic Heater Disengagement |
| Rear Port | 0.95 cm Diameter for External Sensor Integration |
| Control System | Digital Single-Setpoint Controller with Dual-Mode Display (Actual/Setpoint Temperature) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | FH 40 G NBR |
| Instrument Category | Dose Rate Meter |
| Form Factor | Portable |
| Radiation Type | X-ray and Gamma (γ) |
| Detector Architecture | Dual-detector (NaI(Tl) scintillator + plastic scintillator) with NBR (Natural Background Reduction) patented technology |
| Measurement Range | 1 nSv/h – 100 µSv/h |
| Sensitivity | 2000 s⁻¹/µSv/h |
| Energy Response Range (Probe FHZ 672E-10) | 48 keV – 6 MeV |
| Detection Limit | <20% of typical natural background dose rate |
| Host Unit (FH 40 GL-10) | Energy Range: 30 keV – 4.4 MeV |
| Host Measurement Range | 10 nSv/h – 100 mSv/h |
| Host Sensitivity | 2 s⁻¹/µSv/h |
| Host Weight (excl. batteries) | 410 g |
| Battery Life | >250 h (standalone), >30 h (with FHZ 672E-10 connected) |
| Data Handling | Onboard storage, USB interface, PC configuration & data download capability |
| Signal Processing | ADF (Advanced Digital Filtering) adaptive algorithm |