VELP
Filter
Showing 1–30 of 33 results
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | AREC.T |
| Stirrer Type | Magnetic Stirrer |
| Max. Stirring Volume | 15 L (H₂O) |
| Speed Range | 0–1500 rpm |
| Temperature Range | Ambient to 550 °C |
| Heating Plate Diameter | 180 mm |
| Power Rating | 800 W |
| Display | LCD |
| Protection Class | IP42 (per CEI EN 60529) |
| Timer Range | 0–999 min |
| Housing Material | Corrosion-Resistant Construction |
| Weight | 3.3 kg |
| Dimensions | 203 × 94 × 344 mm |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | AREC.X |
| Stirring Capacity | 15 L (H₂O) |
| Speed Range | 0–1500 rpm |
| Temperature Range | Ambient to 550 °C |
| Heating Plate Diameter | 180 mm |
| Power | 800 W |
| Display | LCD |
| Protection Rating | IP42 (per CEI EN 60529) |
| Weight | 3.3 kg |
| Dimensions | 203 × 94 × 344 mm |
| Temperature Accuracy | ±0.5 °C (with VTF digital thermostat), ±1.0 °C (with external Pt100 probe) |
| Max External Probe Temp | 250 °C |
| Compatible Accessories | VTF digital thermostat, Pt100 probe holder, support rod, stirring bars (6×35 mm, 9.5×60 mm, 10×40 mm), flask heating blocks (250/500/1000 mL) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | BOD10 |
| Instrument Type | Laboratory |
| Measurement Principle | Pressure-based Respirometric Method (Mercury-Free Electronic Transducer) |
| Measurement Ranges | 90, 250, 600, 999 mg/L BOD₅ |
| Data Logging Interval | 24 h (5-point profile over standard 5-day incubation) |
| Operating Duration | Configurable from 1 to 28 days |
| Power Supply | Dual Lithium-Ion Batteries (2-year service life) |
| Safety Rating | IEC 61010-1 Class III |
| Ingress Protection | IP54 per EN 60529 |
| Operating Temperature | −20 °C to +65 °C |
| Weight | 80 g |
| Enclosure Material | Stainless Steel (316) with Chemical-Resistant Coating |
| Sample Capacity | Simultaneous monitoring of up to 10 samples (BOD Sensor System 10 configuration) |
| Alarm Function | Automatic out-of-range alert |
| Compliance | ASTM D5210, ISO 5815-1:2019, APHA 5210B, EU Directive 2000/60/EC (Water Framework Directive) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | CN802 |
| Detection Principle | High-Temperature Combustion (Dumas Method) coupled with NDIR CO₂ detection and TCD N₂ detection |
| Sample Throughput | Up to 30 samples unattended |
| Sample Form | Solid and liquid (up to 1 g) |
| Carrier Gases | Helium or Argon (switchable without hardware modification) |
| Compliance | AOAC, AACC, ASBC, ISO, DIN, IFFO, OIV, ASTM, EPA |
| Detection Technologies | NDIR for CO₂, LoGas™ TCD for N₂ |
| Moisture Removal | DriStep™ integrated desiccant system |
| Automation | 30-position autosampler (expandable to 90 positions with additional trays) |
| Software Platform | CNSoft™ + Ermes Cloud Connectivity |
| Regulatory Support | Audit trail, user management, electronic signatures (21 CFR Part 11 ready) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | CN802 |
| Analysis Principle | Dumas Combustion Method |
| Measurement Range | 0.001–200 mg N (equivalent to ppm–100% N in sample) |
| Sample Weight | 200 mg–1 g |
| Digestion/Combustion Time | 3–4 min per sample |
| Repeatability | RSD < 0.5% (verified with EDTA reference standard) |
| Detection Limits | 0.01 mg C, 0.001 mg N |
| Recovery Rate | >99.5% |
| Power Consumption | 1400 W |
| Dimensions (L×W×H) | 655 × 510 × 410 mm |
| Carrier Gas Options | Helium or Argon (dual-gas system, no hardware modification required) |
| Compliance | Designed for GLP/GMP environments |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | CSF 6 |
| Price Range | USD 13,500 – 27,000 |
| Brand | VELP |
|---|---|
| Country of Origin | Italy |
| Model | CSF6-GDE |
| Application Principle | Enzymatic-gravimetric method per AOAC 991.43 and AOAC 2009.01 |
| Sample Capacity | 6 independent positions (CSF6) + 6-position magnetic stirring (GDE) |
| Filtration System | Vacuum-assisted with adjustable vacuum control and gas-backflush |
| Digestion System | Immersion-heated water bath with ±0.2 °C temperature stability, programmable time/temperature profiles |
| Compliance | AOAC Official Methods 991.43 (Total Dietary Fiber), 2009.01 (Soluble/Insoluble Dietary Fiber), and ISO 13905 |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | DK 20 Digester System |
| Max Temperature | 450 °C |
| Temperature Uniformity | ±0.5 °C |
| Sample Capacity | 20 × 250 mL tubes (Ø42 mm) |
| Heating Block Material | Anodized aluminum |
| Housing Material | Stainless steel |
| Power Consumption | 13% lower than previous generation |
| Interface | 4-button digital control panel with tilted, chemically resistant front display |
| Optional Accessories | COD support rack, KS 1000 fume neutralizer |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | DKL Series |
| Instrument Type | Kjeldahl Digestion Unit |
| Max Operating Temperature | 450 °C |
| Temperature Accuracy | ±0.5 °C |
| Ramp Time to 450 °C | 22 min |
| Programmable Steps | 54 |
| Heating Module | Anodized Aluminum Block |
| Digestion Tube Compatibility | DKL8 (250 mL, Ø42 mm), DKL12 (250/400 mL, Ø42 mm), DKL20 (250 mL, Ø42 mm), DKL42 (100 mL, Ø26 mm) |
| Automation Level | Fully Automatic (Digestion + Cooling + End-of-Process Alert) |
| User Interface | Detached LCD Display |
| Unique Technology | VELP TEMS™ (Time, Energy, Money, Space Optimization) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | ECO |
| Instrument Type | Laboratory Digestion Block |
| Digestion Principle | Standard 2-hour Closed-Vessel Oxidation (DIN 38409-H41, ISO 6060, APHA 5220C) |
| Temperature Range | Ambient to 200 °C |
| Thermal Stability | ±0.5 °C (ECO 6/16), ±0.3 °C (ECO 8/25) at 150 °C |
| Heating Time Programmable | 0–199 min |
| Sample Volume Capacity | Up to 200 mL per vial (ECO 6) |
| Batch Capacity | 6 / 8 / 16 / 25 positions |
| Construction | Powder-coated steel housing with chemical-resistant epoxy finish |
| Safety Features | Dual independent overtemperature protection, auto-shutdown on cycle completion, audible end-of-cycle alarm |
| Compliance | Designed for use with EPA Method 410.4, ISO 6060, and DIN 38409-H41 workflows |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | EMA 502 |
| Detection Elements | C, H, N, S, O |
| Sample Forms | Solid, Paste, Liquid |
| Carrier Gases | Helium, Argon |
| Compliance | AOAC, AACC, ASBC, ISO, DIN, IFFO, OIV, ASTM, EPA |
| Software | EMASoft |
| Cloud Integration | VELP Ermes Platform |
| Automation | Optional Autosampler |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | FIWE |
| Sample Capacity | 6 positions (independent operation per sample) |
| Measurement Principle | Gravimetric difference method after sequential acid/alkali digestion (AOAC 978.10, ISO 5498, ISO 6865, EN ISO 13906) |
| Repeatability (RSD) | ±1% |
| Sample Mass Range | 0.5–3 g |
| Reagent Preheating Units | Dual independent RC2 heaters (RT to 370 °C) |
| Filtration & Backflush | Integrated air pump with three-way valve control |
| Waste Handling | Precision peristaltic pump for residue collection and effluent evacuation |
| Safety System | Self-diagnostic routine with audible/visual alarm timer |
| Construction | Stainless steel housing with chemical-resistant coating |
| Display | LCD interface with programmable time (0–99 min) and temperature settings |
| Power | 1200 W |
| Ambient Operating Temperature Control | Electronic PID regulation |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | FTC90 Series |
| Internal Volume | 64 L / 196 L |
| Temperature Range | 3–50 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Control System | Microprocessor-based PID control with forced-air circulation |
| Data Logging | PC connectivity via RS232/USB, compatible with VELP专用 software for time-temperature profiling and programmable cycles |
| Power Consumption | 350 W |
| Compliance | Designed for ISO 5815-1:2017, ISO 5815-2:2017, and APHA Standard Methods 5210B (BOD₅) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | GDE |
| Temperature Control Accuracy | ±0.2 °C |
| Max Operating Temperature | 105 °C |
| Bath Material | Transparent Polycarbonate |
| Stirring Configuration | 6-Position Magnetic Stirring |
| Water Bath Type | Deionized-Water-Compatible Constant-Temperature Bath |
| Automation | Programmable Timer for Unattended Operation |
| Compliance | Designed for AOAC 991.43, AACC 32-05, and ISO 13905 Enzymatic-Gravimetric Methods |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | GDE |
| Heating Power | 900 W |
| Temperature Range | Ambient to 105 °C |
| Temperature Accuracy | ±0.2 °C |
| Water Bath Chamber | Transparent Polycarbonate (Max Temp: 105 °C) |
| Dimensions (W×H×D) | 413 × 295 × 410 mm |
| Weight | 6.2 kg |
| Water Requirement | Deionized Water Recommended |
| Stirring | Integrated Magnetic Stirrer |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | GDE-CFS6 |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Mass Range | 0.5–3 g |
| Relative Error | ≤1% |
| Fiber Quantification Range | 0.1–99% |
| Batch Capacity | 6 samples |
| Housing | Epoxy-coated steel for chemical and mechanical resistance |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | HU6 |
| Sample Capacity | 6 positions |
| Temperature Range | Ambient to 200 °C |
| Programmable Methods | 20 |
| Power Rating | 1350 W |
| Weight | 14.5 kg |
| Voltage | 220 V, 50 Hz |
| Compliance | CE-marked, IEC 61010-1 safety certified |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | JLT6, FC6S |
| Construction | Epoxy-coated steel housing |
| Stirrer speed range (JLT6) | 10–300 rpm, 1 rpm resolution |
| Stirrer speed steps (FC6S) | 10, 15, 30, 45, 60, 90, 120, 150, 200 rpm |
| Microprocessor-controlled timer (JLT6) | 0–999 min or 0–99 h |
| Power consumption | 11 W (JLT6), 23 W (FC6S) |
| Net weight | 17 kg (JLT6), 18 kg (FC6S) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | NDA701 |
| Analysis Method | Dumas combustion |
| Automation Level | Fully automated |
| Detection Limit | 0.003 mg N |
| Reproducibility (RSD) | < 0.5% |
| Recovery | > 99.5% |
| Combustion Temperature | 1030 °C |
| Sample Weight Capacity | up to 1 g |
| Autosampler Capacity | up to 116 samples |
| Carrier Gas | Helium (99.999% purity, 3 bar) |
| Oxygen Supply | 99.999% purity, 3 bar |
| Auxiliary Gas | Compressed air or nitrogen (99.6%, oil- and water-free, 4 bar) |
| Power Consumption | 1400 W |
| Dimensions (W×H×D) | 655 × 510 × 410 mm (655 × 690 × 410 mm with autosampler) |
| Weight | 54 kg |
| Interfaces | USB, RS232 |
| Compliance | AOAC, AACC, ASBC, ISO 14891, OIV |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | NDA702 |
| Analysis Principle | Dumas Combustion Method |
| Carrier Gases | Helium or Argon (switchable without hardware modification) |
| Digestion/Combustion Time | 3–4 min per sample |
| Repeatability (RSD) | < 0.5% |
| Recovery Rate | > 99.5% |
| Detection Limit | 0.001 mg N (He), 0.01 mg N (Ar) |
| Combustion Temperature | 1030 °C |
| Power Consumption | 1400 W |
| Auto-sampler Capacity | Up to 117 positions (4 trays × 30 positions) |
| Dimensions (W×D×H) | 655 × 510 × 410 mm |
| Weight | 55 kg |
| Electrical Supply | 230 V / 50 Hz |
| Gas Purity Requirement | ≥99.999% for He/Ar and O₂ |
| Gas Pressure Requirement | 2 bar for carrier gas and O₂ |
| Detector | Calibrated Thermal Conductivity Detector (TCD), reference-gas-free operation |
| Sample Mass Range | Up to 1.0 g |
| Data Interfaces | USB, RS232 |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | NDA702 |
| Detection Principle | High-Temperature Combustion (Dumas Method) |
| Carrier Gases | Helium and Argon (switchable without hardware/software modification) |
| Analysis Time | ~3–4 min per sample |
| Automation Level | Fully Automated, Unattended Operation |
| Compliance | GLP-compliant architecture, TEMS™ certified design |
| Sample Forms | Solid and liquid matrices |
| Reagent Requirement | None (dry chemistry method) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | OXITEST |
| Instrument Type | Accelerated Oxidation Stability Analyzer |
| Pressure Range | 0–8 bar |
| Temperature Range | Ambient to 110 °C |
| Sample Volume | 100 mL per chamber |
| Power Consumption | 900 W |
| Voltage | 230 V / 50–60 Hz |
| Dimensions (L×W×H) | 365 × 190 × 485 mm |
| Weight | 16.5 kg |
| Safety Features | Integrated safety vacuum tube, visual over-temperature alarm, real-time fault indication |
| Compliance | CE-marked, IEC-compliant, ISO 9001 / ISO 14001 / ISO 45001 (formerly OHSAS 18001) certified |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | Radiation |
| Detection Principle | Geiger-Müller Tube with Mica End-Window |
| Measuring Ranges | 0.5–5.0–50 mR/h (three auto-ranging scales) |
| Alpha Energy Range | up to 2.5 MeV (≥80% detection efficiency at 3.5 MeV) |
| Beta Energy Threshold | ≥150 keV (75% efficiency) |
| Gamma/X-ray Sensitivity | ≥10 keV through mica window |
| Power Supply | 9 V alkaline battery (typical 2000 h operation) |
| Display | Analog needle meter with LED visual alarm and audible buzzer |
| Weight | 0.25 kg |
| Compliance | CE-marked, compliant with IEC 60846-1:2014 for portable radiation survey meters |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | ROTAX6.8 |
| Capacity | 6 × 2 L bottles or 8 × 1 L bottles |
| Rotation Speed | 0–30 rpm |
| Bottle Height Range | 205–270 mm |
| Max Bottle Diameter | 135 mm |
| Display | LCD |
| Power Consumption | 100 W |
| Net Weight | 30 kg |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | SER 158 |
| Configuration | 3-channel or 6-channel |
| Compliance | AOAC, ISO 1443, ISO 6497, EPA 907.1, APHA 2710B, UNI EN 14082 |
| Solvent Recovery Rate | >90% |
| Safety Certification | CE |
| Heating Control | PID-regulated electric heating elements with TEMS™ thermal energy management system |
| Sample Handling | Fully automated Randall extraction cycle with SafeEnd™ overheat protection and SolventXpress™ solvent delivery |
| Data Management | Onboard LCD touchscreen interface with audit-trail-capable result storage and GLP-compliant reporting |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | SER148 |
| Extraction Channels | 6 |
| Sample Capacity per Channel | 0.5–15 g |
| Reproducibility | ±1% |
| Solvent Volume Range | 30–100 mL |
| Solvent Recovery Rate | 50–75% |
| Temperature Control Range | 100–260 °C |
| Immersion Time | 0–999 min |
| Washing Time | 0–999 min |
| Power Consumption | 900 W |
| Net Weight | 40 kg |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | SER158 |
| Application Category | Fully Automated Protein and Fat Determination Instrument |
| Extraction Principle | Randall Continuous Extraction Technology |
| Compliance Standards | AOAC 920.39, ISO 1443, ISO 6496, EPA 3541, APHA 5520E, UNI EN ISO 1443 |
| Safety Certification | CE, IEC 61010-1 |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | TB1 |
| Type | Portable |
| Measurement Range | 0–1000 NTU |
| Repeatability | ±0.01 NTU or ±1% of reading (higher repeatability for gel samples) |
| Light Source | Infrared LED (850 nm) |
| Detection Angle | 90° (ISO 7027 compliant) |
| IP Rating | IP67 (waterproof) |
| Weight | 200 g |
| Dimensions | 68 × 50 × 155 mm |
| Calibration | Single-point using standard reference solutions (e.g., Formazin or StablCal) |
| Brand | VELP |
|---|---|
| Country of Origin | Italy |
| Model | UDK129 |
| Housing Material | Corrosion-Resistant Polymer |
| Display | LCD |
| Programmable Methods | User-Defined Protocols |
| NaOH Addition | Automated, 0–100 mL |
| Cooling Water Consumption | 0.5 L/min at 15°C, 1 L/min at 30°C |
| Distillation Time | ≤5 min for 100 mL water |
| Repeatability (RSD) | ≤1% |
| Nitrogen Recovery Rate | ≥99.5% (for N content 1–200 mg) |
| Detection Limit | ≥0.1 mg N |
| Power Rating | 2100 W |
| Voltage/Frequency | 230/115 V, 50/60 Hz |
| Dimensions (W×H×D) | 385 × 780 × 416 mm |
| Weight | 25 kg |
| Brand | VELP |
|---|---|
| Country of Origin | Italy |
| Model | UDK139 |
| Display | 3.5″ Color Touchscreen |
| Programmable Methods | 10 Custom Protocols |
| NaOH/H₂O Addition | Automatic (0–150 mL / 0–200 mL) |
| Steam Output Regulation | 10–100% |
| Cooling Water Consumption | 0.5 L/min at 15°C |
| Repeatability (RSD) | ≤1% |
| Nitrogen Recovery | ≥99.5% (for 1–200 mg N) |
| Detection Limit | ≥0.1 mg N |
| Distillation Time for 100 mL Water | 4 min |
| Power Rating | 2100 W |
| Voltage/Frequency | 230 V, 50–60 Hz |
| Dimensions (W×H×D) | 385 × 780 × 416 mm |
| Weight | 26 kg |
| Interface | 2×USB |
| Enclosure Material | Corrosion-Resistant Polymer Housing |
| Condenser | Titanium-Coated |
| Safety Sensors | Tube Presence, Safety Door Interlock, Alkali Container Guard Rod, Waste Tray Level, Condensate Flow, Reagent Volume Monitoring |