- All
- Favorite
- Popular
- Most rated
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | S1 TITAN |
| Application | Handheld / Portable |
| Industry Type | General Purpose |
| Elemental Range | Mg–U |
| Quantification Range | ppm to % |
| Energy Resolution | 145 eV |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S8 TIGER (3rd Generation) |
| Instrument Type | Floor-standing WDXRF Spectrometer |
| X-ray Tube Power | 3 kW / 4 kW |
| Analyzable Elements | Be to Am |
| Configuration | Simultaneous/Sequential Multi-channel |
| Detector System | HighSense™ XE + SensorBoost™ Signal Processing |
| Operating Voltage Range | 20–60 kV |
| Sample Capacity | 84-position EasyLoad™ Autoloader with AI Vision |
| Vacuum System | Dual-chamber sealed vacuum with high-transmission beryllium window |
| Crystal Options | 8-position analyzing crystal changer |
| Collimator Options | 4-position collimator changer |
| Filter Options | 10-position filter changer |
| Aperture Mask Options | 5-position mask changer |
| Detectors | Flow-proportional counter & scintillation counter |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Configuration | Benchtop/ Floor-standing |
| Model | S2 POLAR |
| Compliance | ASTM D7220, ASTM D4294, ASTM D6481, ASTM D7751, ASTM D8252, ISO 13032, ISO 20847, ISO 8754, IP 336, IP 496, IP 532, JIS K2541-4 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | M4 TORNADO PLUS |
| Configuration | Benchtop |
| Element Range | C–U (Z = 6–92) |
| Energy Resolution | <140 eV |
| Detector | Dual Large-Area Silicon Drift Detectors (SDD) with Light-Element Windows |
| X-ray Source | Rh-target Microfocus Tube |
| Aperture Management System (AMS) | Integrated |
| Sample Compatibility | Flat & Topographically Irregular Surfaces |
| Compliance | ASTM E1598, ISO 22073, IEC 62471 (LED/X-ray Safety), GLP/GMP-Ready Data Audit Trail |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | M6 JETSTREAM |
| Configuration | Benchtop/Floor-Standing |
| Application Type | General Purpose |
| Elemental Range | Na–U |
| Quantification Range | ppm to wt% |
| Energy Resolution | <140 eV |
| Detector | XFlash® Silicon Drift Detector (SDD) |
| Sample Orientation | Horizontal & Vertical |
| Spot Size Adjustment | 5-step variable microfocus |
| Safety | Integrated X-ray interlock & ultrasonic collision avoidance |
| Portability | Modular design—disassembles into four transportable components |
| Compliance | Designed per IEC 61000-6-3, IEC 61000-6-4, and EN 62471 for radiation safety and EMC |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | M4 TORNADO |
| Form Factor | Benchtop/Floor-Standing |
| Application Sector | Geology & Mining |
| Elemental Range | Na–U |
| Detection Range | ppm to wt% |
| Energy Resolution | ≤130 eV at Mn Kα |
| Excitation | Dual X-ray Tube (Cr & Rh) + 6-Position Filter Wheel |
| Detector | Silicon Drift Detector (XFlash®) |
| Spatial Resolution | <25 µm (spot size) |
| Sample Chamber | Vacuum-Compatible, Motorized XYZ Stage with Zoom Camera Navigation |
| Quantification | Standardless Bulk & Multilayer Analysis |
| Compliance | CE, RoHS, ISO/IEC 17025-ready workflow support |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Powder X-ray Diffractometer |
| Model | D8 ENDEAVOR |
| Detector | LYNXEYE XE-T Energy-Resolving Array Detector |
| Sample Handling | 66-position or 72-position automated sample changer (Ø 51.5 mm and Ø 40 mm formats) |
| Automation Modes | Belt-driven or robotic integration |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready software architecture |
| Regulatory Context | Fully compatible with FDA 21 CFR Part 11–compliant data management workflows |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | D8 QUEST |
| Instrument Type | Single-Crystal X-ray Diffractometer |
| Power | 200 W (0.0002 MW) |
| Detector | PHOTON III MMPAD Hybrid Photon Counting Detector |
| Source Options | Microfocus Rotating Anode (Cu/Mo), Liquid Metal Jet (Ga/In), Dual-Target Auto-Switching |
| Software | APEX3 / PROTEUM3 |
| Compliance | ISO 17025-ready, GLP/GMP-supportive data audit trails, FDA 21 CFR Part 11 compliant modules available |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S8 TIGER |
| Instrument Type | Floor-standing |
| X-ray Tube Power | 1–4.2 kW |
| Elemental Range | Be (4) to Am (95) |
| Instrument Configuration | Scanning-type WDXRF |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | ELIO |
| Application | Portable/Field-Deployable |
| Element Range | Na–U |
| Detection Range | ppm to wt% |
| Energy Resolution | <140 eV (Mn Kα) |
| Detector | Large-Area Silicon Drift Detector (SDD) with CUBE Technology |
| Excitation Source | 50 kV Microfocus X-ray Tube |
| Spot Size | 1 mm (laser-guided) |
| Weight (Measurement Head) | 2.1 kg |
| Compliance | CE, RoHS, IEC 61000-6-3 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | D8 VENTURE |
| Instrument Type | Single-Crystal X-ray Diffractometer |
| Power | 200 W (0.0002 MW) |
| Detector | PHOTON III MMPAD Hybrid Photon-Counting Detector |
| X-ray Source Options | microfocus sealed-tube (Incoatec IμS 3.0), liquid-metal-jet (MetalJet), dual-target auto-switching |
| Software | APEX4 (successor to APEX3/PROTEUM3) |
| Compliance | Fully compatible with CIF deposition standards, supports IUCr-compliant data reduction and structure refinement workflows |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | TRACER 5 |
| Application | Handheld / Portable |
| Industry Use | General-Purpose |
| Elemental Range | F to U |
| Quantification Range | ppm to wt% |
| Energy Resolution | 145 eV |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S2 PICOFOX |
| Detector | 4th-generation XFlash® silicon drift detector (SDD) with Peltier cooling |
| Energy resolution | 160 eV at Mn Kα (100 kcps) |
| Elemental range | Al (13) to U (92) |
| Sample volume | 1–50 µL (liquid/suspension), ≤10 µg (powder) |
| Automation options | 1-position or 25-position autosampler |
| Compliance | Fully compliant with ISO 8258 (control charts), ISO/IEC 17025 (testing laboratories), and supports GLP/GMP data integrity requirements per FDA 21 CFR Part 11 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | D8 DISCOVER |
| Instrument Type | Powder X-ray Diffractometer |
| Power Rating | 0.0001 kW |
| Compliance | Fully Compliant with ISO 17025, ASTM E975, and IEC 61000-6-3 for Electromagnetic Compatibility |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | D8 ADVANCE |
| Instrument Type | Powder X-ray Diffractometer |
| Power | 0.0001° angular resolution |
| 2θ Range | −110° to +168° |
| X-ray Tube Targets | Cr / Co / Cu (standard-size) |
| Detector Options | LYNXEYE Array Detector, LYNXEYE XE-T Energy-Dispersive Detector |
| Dimensions | 1868 × 1300 × 1135 mm |
| Weight | 770 kg |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | D6 PHASER |
| Instrument Type | Powder X-ray Diffractometer |
| Generator Power | 600 W or 1200 W |
| 2θ Calibration Accuracy | ±0.01° |
| Detector | LYNXEYE XE-T Energy-Resolving Detector |
| Beam Optimization | Dynamic Beam Optimization (DBO) |
| Cooling | Air-Cooled (No External Water Chiller Required) |
| Footprint | Compact Benchtop Design |
| Measurement Geometries | Bragg–Brentano Reflection, Transmission, Grazing-Incidence XRD (GIXRD), X-ray Reflectivity (XRR), Residual Stress Analysis, Texture Analysis |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S8 LION |
| Instrument Type | Floor-standing |
| X-ray Tube Power | 3–4 kW |
| Analyzable Elements | C (6) to U (92) |
| Instrument Configuration | Simultaneous Multi-channel |
| Compliance | DIN EN ISO 9001:2008, CE, TÜV/PTB certified, radiation dose < 1 µSv/h (H*) |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CTX |
| Application | Portable/Benchtop |
| Industry Type | General-Purpose |
| Elemental Range | Mg to U |
| Quantification Range | ppm to % |
| Energy Resolution | 145 eV |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S6 JAGUAR |
| Instrument Type | Benchtop |
| Instrument Kind | Scanning |
| X-ray Tube Power | 400 W |
| Analyzable Elements | F to Am (Fluorine to Americium) |
| Detector | High-sensitivity solid-state detector (HighSense XE™) |
| Optical Configuration | Compact WDXRF optical path with up to 4 collimators, up to 4 analyzing crystals, and dual high-sensitivity detectors |
| Software Platform | SPECTRA.ELEMENTS with SMART-QUANT WD fundamental parameters quantification |
| Automation Interface | AXSCOM-compatible |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S2 PUMA Series 2 |
| Configuration Options | Benchtop / Floor-standing |
| Elemental Range | C (Z=6) to Am (Z=95) |
| X-ray Tube Power | 50 W |
| Detector | HighSense™ Silicon Drift Detector (SDD) |
| Sample Chamber Dimensions | 450 × 420 × 100 mm |
| Autochanger Capacity | Up to 20 positions (XY Autochanger) or 12–18 samples (Carousel) |
| Mapping Resolution | Down to 1 mm |
| Spot Size | 1–34 mm (with collimator masks) |
| Software | SPECTRA.ELEMENTS with SMART.QUANT FP |
| Compliance | Designed for GLP/GMP environments |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S4 TSTAR |
| Technique | Total Reflection X-Ray Fluorescence (TXRF) |
| Detection Limit | Sub-ppb for liquid, solid, and thin-film samples |
| Sample Forms | Liquids, suspensions, dried residues, wafers, microscope slides, quartz carriers, membranes, filters, and nanoparticle layers |
| Compliance Context | Supports ISO 17025-compliant workflows |
Show next