Empowering Scientific Discovery

Bruker AXS Inc. (X-ray Products and Electron Microscopy Analytical Instruments)

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelS1 TITAN
ApplicationHandheld / Portable
Industry TypeGeneral Purpose
Elemental RangeMg–U
Quantification Rangeppm to %
Energy Resolution145 eV
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
ModelS8 TIGER (3rd Generation)
Instrument TypeFloor-standing WDXRF Spectrometer
X-ray Tube Power3 kW / 4 kW
Analyzable ElementsBe to Am
ConfigurationSimultaneous/Sequential Multi-channel
Detector SystemHighSense™ XE + SensorBoost™ Signal Processing
Operating Voltage Range20–60 kV
Sample Capacity84-position EasyLoad™ Autoloader with AI Vision
Vacuum SystemDual-chamber sealed vacuum with high-transmission beryllium window
Crystal Options8-position analyzing crystal changer
Collimator Options4-position collimator changer
Filter Options10-position filter changer
Aperture Mask Options5-position mask changer
DetectorsFlow-proportional counter & scintillation counter
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
ConfigurationBenchtop/ Floor-standing
ModelS2 POLAR
ComplianceASTM D7220, ASTM D4294, ASTM D6481, ASTM D7751, ASTM D8252, ISO 13032, ISO 20847, ISO 8754, IP 336, IP 496, IP 532, JIS K2541-4
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
ModelM4 TORNADO PLUS
ConfigurationBenchtop
Element RangeC–U (Z = 6–92)
Energy Resolution<140 eV
DetectorDual Large-Area Silicon Drift Detectors (SDD) with Light-Element Windows
X-ray SourceRh-target Microfocus Tube
Aperture Management System (AMS)Integrated
Sample CompatibilityFlat & Topographically Irregular Surfaces
ComplianceASTM E1598, ISO 22073, IEC 62471 (LED/X-ray Safety), GLP/GMP-Ready Data Audit Trail
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
ModelM6 JETSTREAM
ConfigurationBenchtop/Floor-Standing
Application TypeGeneral Purpose
Elemental RangeNa–U
Quantification Rangeppm to wt%
Energy Resolution<140 eV
DetectorXFlash® Silicon Drift Detector (SDD)
Sample OrientationHorizontal & Vertical
Spot Size Adjustment5-step variable microfocus
SafetyIntegrated X-ray interlock & ultrasonic collision avoidance
PortabilityModular design—disassembles into four transportable components
ComplianceDesigned per IEC 61000-6-3, IEC 61000-6-4, and EN 62471 for radiation safety and EMC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
ModelM4 TORNADO
Form FactorBenchtop/Floor-Standing
Application SectorGeology & Mining
Elemental RangeNa–U
Detection Rangeppm to wt%
Energy Resolution≤130 eV at Mn Kα
ExcitationDual X-ray Tube (Cr & Rh) + 6-Position Filter Wheel
DetectorSilicon Drift Detector (XFlash®)
Spatial Resolution<25 µm (spot size)
Sample ChamberVacuum-Compatible, Motorized XYZ Stage with Zoom Camera Navigation
QuantificationStandardless Bulk & Multilayer Analysis
ComplianceCE, RoHS, ISO/IEC 17025-ready workflow support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
Instrument TypePowder X-ray Diffractometer
ModelD8 ENDEAVOR
DetectorLYNXEYE XE-T Energy-Resolving Array Detector
Sample Handling66-position or 72-position automated sample changer (Ø 51.5 mm and Ø 40 mm formats)
Automation ModesBelt-driven or robotic integration
ComplianceDesigned for GLP/GMP environments with audit-trail-ready software architecture
Regulatory ContextFully compatible with FDA 21 CFR Part 11–compliant data management workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
ModelD8 QUEST
Instrument TypeSingle-Crystal X-ray Diffractometer
Power200 W (0.0002 MW)
DetectorPHOTON III MMPAD Hybrid Photon Counting Detector
Source OptionsMicrofocus Rotating Anode (Cu/Mo), Liquid Metal Jet (Ga/In), Dual-Target Auto-Switching
SoftwareAPEX3 / PROTEUM3
ComplianceISO 17025-ready, GLP/GMP-supportive data audit trails, FDA 21 CFR Part 11 compliant modules available
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
ModelS8 TIGER
Instrument TypeFloor-standing
X-ray Tube Power1–4.2 kW
Elemental RangeBe (4) to Am (95)
Instrument ConfigurationScanning-type WDXRF
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
ModelELIO
ApplicationPortable/Field-Deployable
Element RangeNa–U
Detection Rangeppm to wt%
Energy Resolution<140 eV (Mn Kα)
DetectorLarge-Area Silicon Drift Detector (SDD) with CUBE Technology
Excitation Source50 kV Microfocus X-ray Tube
Spot Size1 mm (laser-guided)
Weight (Measurement Head)2.1 kg
ComplianceCE, RoHS, IEC 61000-6-3
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
ModelD8 VENTURE
Instrument TypeSingle-Crystal X-ray Diffractometer
Power200 W (0.0002 MW)
DetectorPHOTON III MMPAD Hybrid Photon-Counting Detector
X-ray Source Optionsmicrofocus sealed-tube (Incoatec IμS 3.0), liquid-metal-jet (MetalJet), dual-target auto-switching
SoftwareAPEX4 (successor to APEX3/PROTEUM3)
ComplianceFully compatible with CIF deposition standards, supports IUCr-compliant data reduction and structure refinement workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginUSA
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelTRACER 5
ApplicationHandheld / Portable
Industry UseGeneral-Purpose
Elemental RangeF to U
Quantification Rangeppm to wt%
Energy Resolution145 eV
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
ModelS2 PICOFOX
Detector4th-generation XFlash® silicon drift detector (SDD) with Peltier cooling
Energy resolution160 eV at Mn Kα (100 kcps)
Elemental rangeAl (13) to U (92)
Sample volume1–50 µL (liquid/suspension), ≤10 µg (powder)
Automation options1-position or 25-position autosampler
ComplianceFully compliant with ISO 8258 (control charts), ISO/IEC 17025 (testing laboratories), and supports GLP/GMP data integrity requirements per FDA 21 CFR Part 11
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
ModelD8 DISCOVER
Instrument TypePowder X-ray Diffractometer
Power Rating0.0001 kW
ComplianceFully Compliant with ISO 17025, ASTM E975, and IEC 61000-6-3 for Electromagnetic Compatibility
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelD8 ADVANCE
Instrument TypePowder X-ray Diffractometer
Power0.0001° angular resolution
2θ Range−110° to +168°
X-ray Tube TargetsCr / Co / Cu (standard-size)
Detector OptionsLYNXEYE Array Detector, LYNXEYE XE-T Energy-Dispersive Detector
Dimensions1868 × 1300 × 1135 mm
Weight770 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
ModelD6 PHASER
Instrument TypePowder X-ray Diffractometer
Generator Power600 W or 1200 W
2θ Calibration Accuracy±0.01°
DetectorLYNXEYE XE-T Energy-Resolving Detector
Beam OptimizationDynamic Beam Optimization (DBO)
CoolingAir-Cooled (No External Water Chiller Required)
FootprintCompact Benchtop Design
Measurement GeometriesBragg–Brentano Reflection, Transmission, Grazing-Incidence XRD (GIXRD), X-ray Reflectivity (XRR), Residual Stress Analysis, Texture Analysis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
ModelS8 LION
Instrument TypeFloor-standing
X-ray Tube Power3–4 kW
Analyzable ElementsC (6) to U (92)
Instrument ConfigurationSimultaneous Multi-channel
ComplianceDIN EN ISO 9001:2008, CE, TÜV/PTB certified, radiation dose < 1 µSv/h (H*)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelCTX
ApplicationPortable/Benchtop
Industry TypeGeneral-Purpose
Elemental RangeMg to U
Quantification Rangeppm to %
Energy Resolution145 eV
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
ModelS6 JAGUAR
Instrument TypeBenchtop
Instrument KindScanning
X-ray Tube Power400 W
Analyzable ElementsF to Am (Fluorine to Americium)
DetectorHigh-sensitivity solid-state detector (HighSense XE™)
Optical ConfigurationCompact WDXRF optical path with up to 4 collimators, up to 4 analyzing crystals, and dual high-sensitivity detectors
Software PlatformSPECTRA.ELEMENTS with SMART-QUANT WD fundamental parameters quantification
Automation InterfaceAXSCOM-compatible
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
ModelS2 PUMA Series 2
Configuration OptionsBenchtop / Floor-standing
Elemental RangeC (Z=6) to Am (Z=95)
X-ray Tube Power50 W
DetectorHighSense™ Silicon Drift Detector (SDD)
Sample Chamber Dimensions450 × 420 × 100 mm
Autochanger CapacityUp to 20 positions (XY Autochanger) or 12–18 samples (Carousel)
Mapping ResolutionDown to 1 mm
Spot Size1–34 mm (with collimator masks)
SoftwareSPECTRA.ELEMENTS with SMART.QUANT FP
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
ModelS4 TSTAR
TechniqueTotal Reflection X-Ray Fluorescence (TXRF)
Detection LimitSub-ppb for liquid, solid, and thin-film samples
Sample FormsLiquids, suspensions, dried residues, wafers, microscope slides, quartz carriers, membranes, filters, and nanoparticle layers
Compliance ContextSupports ISO 17025-compliant workflows
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0