Empowering Scientific Discovery

Changchun Jida-Xiaotian'e Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiada Xiaotian’e
OriginJilin, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelGDYK-211S
Detection Limit0.05 mg/m³
Measurement Range0.00–4.00 mg/m³
Accuracy±5%
Power Supply9 V alkaline battery (≥40 h continuous operation)
Auto-power-off10 min inactivity
MethodColorimetric reaction with pre-packaged reagent cartridges
Dimensions & WeightCompact handheld design, <300 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiada Xiaotian'e
OriginJilin, China
Manufacturer TypeDirect Manufacturer
ModelGDYK-401RC
Detection PrincipleColorimetric Method
Measurement RangeFormaldehyde: 0.00–2.00 mg/m³
Ammonia0.00–5.00 mg/m³
Benzene & BTEX0.00–1.00 mg/m³
TVOC0.00–4.00 mg/m³
Resolution0.01 mg/m³
Repeatability≤ ±5%
Sampling MethodPump-aspirated
Response Time (Formaldehyde)22 min
Operating Temperature10–40 °C
Relative Humidity Range15–95% RH
Detection LimitsFormaldehyde: 0.01 mg/m³
Ammonia0.10 mg/m³
Benzene & BTEX0.05 mg/m³
TVOC0.05 mg/m³
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiada Xiaotian'e
OriginJilin, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelGDYS-101SA
Instrument TypePortable
Measurement PrincipleColorimetric Method (Nessler Reagent)
Measurement Range0.00–5.00 mg/L as N
Accuracy±5%
Detection Limit0.10 mg/L as N
Light Source Wavelength430 nm
Compliance StandardGB/T 5750.5–2006
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiada Xiaotian'e
OriginJilin, China
Manufacturer TypeDirect Manufacturer
Instrument TypePortable Analyzer
ModelGDYS-101SN2
Measurement PrincipleDPD Colorimetric Spectrophotometry
Measured ParameterFree Residual Chlorine
Measurement Range0.00–5.00 mg/L
Accuracy±5% of reading
Detection Limit0.05 mg/L
Analysis Time≤3 minutes per sample
Reagent FormatSingle-use, pre-calibrated DPD reagent vials
ComplianceDesigned for field-deployable water quality screening in accordance with standard methods aligned with APHA 4500-Cl G, ISO 7393-2, and EPA Method 334.0
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiada Xiaotianshe
OriginJilin, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelGDYS-102SL
PricingUpon Request
Detection Limit20.0 mg/L
Measurement Range0.0–500.0 mg/L
Accuracy±5%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJilin University Xiaotian’e
OriginJilin, China
Manufacturer TypeDirect Manufacturer
Origin CategoryDomestic (China)
ModelGDYS-102SY
Instrument TypePortable/HANDHELD Water Quality Analyzer
Target AnalytePhosphate
Detection Limit0.1 mg/L
Measurement Range0.0–1.0 mg/L
Accuracy±5%
Analysis Time≤15 minutes
Reagent FormatSingle-use, pre-packaged test kits
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiada Xiaotian'e
OriginJilin, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelGDYK-102S
Light SourceHigh-Brightness LED
Wavelength635 nm
Detection Limit0.005 mg/m³
Measurement Range0.000–0.100 mg/m³ (40 L sampling volume) or 0.000–0.800 mg/m³ (5 L sampling volume)
Accuracy±5%
Power SupplyAC 220 V ±22 V, 50 Hz ±1 Hz
Dimensions310 × 225 × 125 mm
Weight1.7 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJilin University Xiaotian’e
OriginJilin, China
Manufacturer TypeDirect Manufacturer
Origin CategoryDomestic (China)
ModelGDYS-101SI2
Price RangeUSD 280–1,400 (FOB)
Instrument TypePortable / Handheld Water Quality Analyzer
Measured ParameterCalcium (Ca²⁺)
Detection Limit0.10 mg/L
Measurement Range0.00–2.00 mg/L
Accuracy±3% of full scale
MethodCPPI (Colorimetric Photometric Procedure with Integrated Reagent)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiada Xiaotian'e
OriginJilin, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelGDYS-104SM
Light SourceHigh-brightness LED
Wavelength510 nm
Detection Limit5 mg/L
Measurement RangeLow Range: 5.0–500.0 mg/L
High Range0.05–65% (requires sample dilution)
Accuracy±5%
Power SupplyDC 9 V
Dimensions190 × 110 × 95 mm
Weight0.4 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJida Xiaotian'e
OriginJilin, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelGDYS-102SK
Price RangeUSD 280–1,400 (FOB)
Instrument TypePortable/Handheld Water Quality Analyzer
Measured ParameterPermanganate Index (COD<sub>Mn</sub>)
Detection Limit0.50 mg/L
Measurement Range0.00–8.00 mg/L
Accuracy±5% of reading
MethodMicro-titration with pre-packaged reagent kit
Analysis Time≤10 minutes per sample
Sample MatrixDrinking water and raw water sources with chloride concentration <300 mg/L (as Cl⁻)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiada Xiaotian’e
OriginJilin, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelGDYS-301S
Instrument TypePortable
Measurement PrincipleDPD Spectrophotometry
Measured ParametersResidual Chlorine, Chlorine Dioxide, Chlorite
Measurement RangesChlorine Dioxide: 0.00–3.00 mg/L
Residual Chlorine0.00–2.50 mg/L
Chlorite0.00–2.00 mg/L
Accuracy±5%
LODChlorine Dioxide: 0.02 mg/L
Residual Chlorine0.01 mg/L
Chlorite0.05 mg/L
Light SourceHigh-Brightness LED
Wavelength520 nm
Absorbance Range0.000–2.000 Abs
Stability≤0.005 Abs/h
Power Supply9 V Battery (Auto-Shutdown after 30 min
Operating Temperature0–50 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJilin University-Xiaotian'e
OriginJilin, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelGDYK-W100S
Price RangeUSD 700–1,400 (FOB)
Measurement PrincipleColorimetric Method
Measurement Range0.00–2.00 ppm
Resolution0.1 ppm
Repeatability≤ ±5%
Sampling MethodPump-Aspiration
Response Time5–15 minutes
Operating Temperature0–25 °C
Relative Humidity Range15–90% RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiada Xiaotian’e
ModelGDYK-201S
PrincipleColorimetric Method (Acetylacetone Derivatization)
Measurement Range0.00–1.00 mg/m³
Resolution0.01 mg/m³
Repeatability≤ ±5%
Sampling MethodPump-Aspiration with Flow Calibration
Response Time22 min
Operating Temperature10–40 °C
Relative Humidity Range15–95% RH
Light SourceHigh-Brightness LED @ 630 nm
Power SupplyDC 9 V (Alkaline Battery)
Auto-ShutdownAfter 30 min Inactivity
Built-in Calibration CurveYes
Sample Vessel19 mm Graduated Cuvette (Reaction + Measurement in One)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiada Xiaotianshe
OriginJilin, China
Manufacturer TypeDirect Manufacturer
Instrument TypePortable
Measurement PrinciplePotassium Dichromate Digestion Method (On-site Compatible)
Wavelengths410 nm and 630 nm
Measurement RangesRange 1: 0–100 mg/L
Range 250–1000 mg/L
Range 3500–3000 mg/L
Accuracy±5%
Detection Limit4 mg/L
Light SourceHigh-Brightness LED
Power SupplyDC 9 V
Dimensions200 × 105 × 95 mm
Weight0.4 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJilin University Xiaotian'e
OriginJilin, China
Manufacturer TypeDirect Manufacturer
Regional CategoryDomestic (China)
ModelMAI-50G
Price RangeUSD 1,400–7,000
Instrument TypeBenchtop Laboratory Analyzer
Measurement PrincipleInfrared Spectrophotometry (Dual-Wavelength Absorption at C–H Stretching Bands)
Measurement Range0.0–80.0 mg/L
Detection Limit0.2 mg/L
Accuracy≤1.5% RSD (at 10 mg/L)
Wavenumber Range3400–2400 cm⁻¹
Absorbance Range0.0000–2.0000 Abs
Wavenumber Accuracy±2 cm⁻¹
Wavenumber Repeatability±2 cm⁻¹
Baseline Drift≤±0.005 Abs / 30 min
Operating Temperature5–35 °C
Linearity Correlation CoefficientR > 0.999
Power SupplyAC 220 V ±10%, 50–60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiDa-Xiaotian'e
OriginJilin, China
Manufacturer TypeManufacturer
Region of OriginDomestic (China)
ModelGDYK-202S
Detection PrincipleColorimetric Method (MBTH-based spectrophotometry)
Measurement Range0.00–1.00 mg/m³ (at 10 L sampling volume)
Sampling MethodPump-aspiration
Light SourceHigh-brightness LED
Wavelength630 nm
Detection Limit0.01 mg/m³ (at 10 L sampling volume)
Accuracy±5%
Power Supply9 V rechargeable lithium battery
ComplianceGB/T 18204.2–2014
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJilin University Xiaotian’e
OriginJilin, China
Manufacturer TypeDirect Manufacturer
Origin CategoryDomestic (China)
ModelGDYS-101ST
PricingUpon Request
Detection Limit0.1 mg/L
Measurement Range0.0–3.0 mg/L
Accuracy±5%
Method StandardGB/T 5750.6–2006
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiada Xiaotian'e
ModelGDYS-302S
Instrument TypePortable/handheld water quality analyzer
Detection ParametersAmmonia nitrogen (NH₃-N), Nitrite nitrogen (NO₂⁻-N), Nitrate nitrogen (NO₃⁻-N)
Optical SourceHigh-brightness LED
Wavelengths430 nm, 538 nm
LODNH₃-N: 0.1 mg/L (as N), NO₂⁻-N: 0.01 mg/L (as N), NO₃⁻-N: 0.5 mg/L
Measurement RangesNH₃-N: 0.00–5.00 mg/L (as N), NO₂⁻-N: 0.00–0.40 mg/L (as N), NO₃⁻-N: 0.0–20.0 mg/L
Accuracy±5% FS
Power SupplyAC 220 V ±10%, 50 Hz ±2% or rechargeable Li-ion battery (7.4 V, 900 mAh)
Dimensions310 × 225 × 125 mm
Weight1.7 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiDa-Xiaotian'e
OriginJilin, China
ModelGDYS-MW400
Instrument TypePortable / Handheld Water Quality Analyzer
Detection ParametersTotal Phosphorus, Ammonia Nitrogen, Total Nitrogen, Chemical Oxygen Demand (COD) (High-Range & Low-Range)
Wavelengths380 / 430 / 470 / 520 / 538 / 595 / 630 nm
Photometric Stability±0.005 Abs/h
DetectorIntegrated Photodiode Sensor
Light SourceHigh-Brightness LED (100,000 h lifetime)
Sample Cells19 mm cylindrical glass cuvettes & 50 mm rectangular glass cuvettes
Power SupplyAC 220 V ±10 %, 50 Hz ±1 Hz / Rechargeable Li-ion battery (8.4 V, 1800 mAh)
Operating Temperature5–40 °C
Dimensions310 × 225 × 125 mm
Weight1.7 kg
Data InterfacesUSB 2.0, RS-232
ConnectivityBluetooth (for printer pairing), PC software for Excel export and report generation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJilin University Little Swan
OriginChangchun, Jilin, China
ModelGDYS-S7000
Instrument TypePortable Colorimetric Water Quality Analyzer
Dimensions85 mm × 200 mm × 95 mm
DisplayFull-color TFT Touchscreen
PowerRechargeable Lithium-ion Battery
Weight<1000 g
Detection ParametersFree Chlorine, Total Chlorine, Chlorine Dioxide, Ozone, Formaldehyde, Chlorite, Available Chlorine
CalibrationPre-stored Multi-point Calibration Curves
ConnectivityBluetooth-enabled for Thermal Printer Integration
Sample CellOptimized Long-Path Cuvette Design
ReagentsPre-formulated, Single-use Solid/Powdered Reagent Kits
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiada Xiaotianshe
OriginJilin, China
Manufacturer TypeDirect Manufacturer
Origin CategoryDomestic (China)
ModelGDYS-101SZ2
PricingAvailable Upon Request
Detection Limit0.5 NTU
Measurement Range0.0–60.0 NTU
Accuracy±5% of reading
ComplianceGB/T 5750.4–2006
Analysis Time≤3 minutes per sample
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiDa-Xiaotian'e
OriginJilin, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelGDYS-101SG
Instrument TypePortable/Handheld Water Quality Analyzer
Target AnalyteHexavalent Chromium (Cr(VI))
Detection Limit0.01 mg/L
Measurement Range0.00–1.00 mg/L
Accuracy±5%
Method ComplianceGB/T 5750.6–2006
Analysis Time≤3 minutes per sample
Reagent FormatSingle-use, pre-packaged test kit
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiDa-Xiaotianshen
OriginJilin, China
Manufacturer TypeOEM Manufacturer
Region of ManufactureDomestic (China)
ModelGDYS-301M
Price RangeUSD 1,400–4,200
Instrument TypeBenchtop Water Quality Analyzer
Test ParametersFree Chlorine, Total Chlorine, Chlorine Dioxide, Nitrate Nitrogen, Ozone, Ammonia Nitrogen, and 35 Total Parameters
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJilin University–Xiaotian’e
OriginJilin, China
Manufacturer TypeDirect Manufacturer
Regional CategoryDomestic (China)
ModelMAI-100G Infrared Oil Content Analyzer
Instrument TypeLaboratory Benchtop Analyzer
Measurement PrincipleInfrared Spectrophotometry (C–H Stretch Absorption at 2930 cm⁻¹, 2960 cm⁻¹, and 2850 cm⁻¹)
Measurement Range0.40–100 mg/L (using 4-cm pathlength cell, standard n-hexane extract, 1:1 extraction ratio)
Detection Limit< 0.1 mg/L (per JJG 950–2012 verification protocol)
Accuracy±5% RSD (at 40 mg/L standard solution)
ComplianceHJ 637–2018, JJG 950–2012 Class A requirements, ASTM D7066–22 (equivalent IR methodology), ISO 9377-2:2000 (Water quality — Determination of hydrocarbon oil index — Part 2: Infrared spectrometric method)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0