- All
- Favorite
- Popular
- Most rated
| Brand | Jilin University–Xiaotian’e |
|---|---|
| Model | GDYQ-107S |
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | PRC |
| Detection Limit | 25.0 mg/kg |
| Measurement Range | 0.0–2000.0 mg/kg |
| Accuracy | ±5% |
| Analysis Time | ≤35 min per sample |
| Sample Processing | Integrated proprietary pretreatment kit and reagents |
| Brand | JiDa-Xiaotianshen |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (PRC) |
| Model | GDYQ-201SX |
| Instrument Type | Beer-Specific Formaldehyde Analyzer |
| Application | Laboratory Use |
| Dimensions (L × W × H) | 310 mm × 225 mm × 125 mm |
| Weight | 1.7 kg |
| Detection Limit | 1.0 mg/kg |
| Measurement Range | 0.0–100.0 mg/kg |
| Accuracy | ±2% |
| Method Reference | Modified GB/T 5009.49–2003 |
| Analysis Time | ≤15 minutes per sample |
| Display | Backlit LCD with Chinese UI |
| Control System | Embedded MCU with integrated data management functions |
| Sample Prep | Dedicated pretreatment kit + single-use reagent cartridges |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-4000S |
| Function Type | Single-Analyte Detection (Iodine) |
| Sample Versatility | Multi-Sample Compatible |
| Detection Limit | 2.0 mg/kg |
| Measurement Range | 0.0–80.0 mg/kg |
| Accuracy | ±2% |
| Analysis Time | ≤3 minutes per sample |
| Display | Backlit LCD with Chinese UI |
| Control System | Embedded MCU with data logging, parameter configuration, statistical processing, and RS232 communication |
| Sample Prep | Dedicated pretreatment kit + single-use reagent cartridges |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (PRC) |
| Model | GDYQ-900M |
| Price Range | USD 7,000–14,000 (FOB) |
| Functionality | Multi-analyte (simultaneous detection of >20 food safety parameters) |
| Sample Versatility | Universal for solid, liquid, and semi-solid food matrices |
| Optical Detection Range | 495–530 nm |
| Repeatability | ≤ ±5% CV or ±5 RLUs |
| Detection Channels | 16 independent optical/analytical channels |
| Power Supply | AC/DC dual-mode |
| Display | 10.1" capacitive touchscreen, 1024 × 768 resolution |
| Data Storage | Internal SSD (≥64 GB) |
| Connectivity | Wi-Fi 802.11 b/g/n, Ethernet (RJ45), USB 2.0 × 2 |
| Output | Integrated thermal printer + external printer support via USB/Ethernet |
| Operating System | Windows Embedded Standard 7 |
| Software | Proprietary modular detection platform with remote OTA and local USB firmware update capability |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GDYQ-100M (50 Parameters) |
| Price Range | USD 7,000 – 14,000 |
| Function Type | Multi-Analyte (Simultaneous Quantitative Screening) |
| Sample Applicability | Universal for Solid, Semi-Solid & Liquid Food Matrices |
| Optical Wavelength Range | 400 nm – 630 nm |
| Typical Analysis Time per Parameter | 3–10 minutes |
| Brand | Jilin University Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYN-308S |
| Pricing | Available Upon Request |
| Detection Principle | Acetylcholinesterase (AChE) Inhibition Assay |
| Target Analytes | Organophosphorus & Carbamate Pesticides |
| Sample Throughput | 8 samples per run |
| Detection Time | ≤13 minutes per batch |
| Detection Limit | 0.1–3.0 mg/kg |
| Inhibition Rate Range | 0–100% |
| Measurement Accuracy | ±10% (relative to reference standard) |
| Brand | JiDa Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYN-1012SD |
| Detection Methods | Enzyme Inhibition Assay, Thin-layer Chromatography (TLC) |
| Measurement Range | Organophosphates & Carbamates Inhibition Rate: 0–100% |
| Organochlorines | 0.0–40.0 mg/kg |
| Pyrethroids | 0.0–40.0 mg/kg |
| Number of Channels | 12 |
| Measurement Error | ±10% |
| LOD | Organophosphates & Carbamates: 0.01–3.0 mg/kg |
| Organochlorines | 0.3 mg/kg |
| Pyrethroids | 0.3 mg/kg |
| Light Sources | High-brightness LEDs at 405 nm and 254 nm |
| Absorbance Range | 0.000–2.000 Abs |
| Dimensions | 470 × 280 × 180 mm |
| Weight | 3.6 kg |
| Power Supply | AC 220 V ± 10%, 50 Hz ± 1 Hz |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYJ-201SY |
| Detection Limit | 5.00 mg/kg |
| Measurement Range | 0.00–500.00 mg/kg |
| Accuracy | ±5% |
| Compliance | GB/T 2912.1–1998, GB 18401–2001 |
| Analysis Time | ≤15 min per sample |
| Display | Backlit LCD with Chinese interface |
| Control System | Embedded microcontroller |
| Data Functions | Measurement logging, statistical processing, configuration, help, and RS232 communication |
| Sample Prep | Dedicated extraction apparatus + single-use reagent kits |
| Quantitative Output | mg/kg (formaldehyde content in fabric) |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYN-501MA |
| Detection Method | Thin-layer Chromatography (TLC) |
| Measurement Range | Organophosphates: 0.03–20 mg/kg |
| Carbamates | 0.03–20 mg/kg |
| Pyrethroids | 0.10–30 mg/kg |
| Organochlorines | 0.10–10 mg/kg |
| Light Source | 254 nm UV lamp |
| Warm-up Time | ≤5 min |
| Irradiance | ≥1000 µW/cm² |
| Lamp Lifetime | ≥12,000 h |
| Wavelength Repeatability | ±1 nm |
| Wavelength Accuracy | ±5 nm |
| Filter Transmittance | ≥95% |
| Spot Spacing | 5–30 mm |
| Sample Volume | 2.5–15 µL |
| Spot Diameter | ≤2.0 mm |
| Operating Temperature | 5–40 °C |
| Relative Humidity | 10–85% RH |
| Data Interface | USB 2.0 |
| Power Supply | 220 V ±22 V, 50 Hz ±1 Hz |
| Software Platform | Windows XP |
| Detection Modes | Transmission & Reflectance |
| Dimensions | 580 × 360 × 260 mm |
| Weight | 15.8 kg |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GDYN-1024SC |
| Price Range | USD 4,200 – 7,000 (FOB) |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% inhibition |
| Number of Channels | 24 |
| Measurement Error | ±6% |
| Limit of Detection (LOD) | 0.01–3.0 mg/kg |
| Light Source | Silicon Photodiode |
| Wavelength | 405 nm |
| Absorbance Range | 0.000–2.000 Abs |
| Inhibition Rate Range | 0–100% |
| Precision | ±6% |
| Detection Limit | 0.01–3.0 mg/kg |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GDYQ-110S2 |
| Function Type | Multi-analyte (Methanol + Ethanol) |
| Sample Format | Single-sample dedicated format |
| Wavelengths | 412 nm, 595 nm |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-110SF |
| Function Type | Single-Analyte Quantitative Detection |
| Sample Compatibility | Multi-Sample Universal Format |
| Detection Time | 10 minutes |
| Detection Limit | 0.1 mg KOH/g |
| Measurement Range | 0.0–30.0 mg KOH/g |
| Accuracy | ±5% (Relative Standard Deviation) |
| Reference Standard | GB/T 5009.37–2003 |
| Brand | Jilin University & Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYQ-110SH |
| Pricing | Available Upon Request |
| Detection Limit | Stale rice ≥3 years old |
| Measurement Range | 1–3 years storage duration |
| Accuracy | ±5% relative to reference standard methods |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYQ-103SC |
| Function Type | Single-Analyte Detection |
| Sample Versatility | Multi-Matrix (Solid & Liquid) |
| Optical Wavelength | 538 nm |
| Detection Limit | 10.0 mg/kg (solid), 1.00 mg/L (liquid) |
| Quantification Range | 0.0–600.0 mg/kg (solid), 0.0–60.0 mg/L (liquid) |
| Accuracy | ±5% |
| Power Supply | AC 220 V ±22 V, 50 Hz ±1 Hz |
| Dimensions | 310 × 225 × 125 mm |
| Weight | <1.7 kg |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (PRC) |
| Model | GDYQ-1000S |
| Function Type | Single-Analyte Dedicated Instrument |
| Sample Specificity | Soy Sauce Only |
| Detection Time | 30 minutes |
| Detection Range | 0.0–2.0 g/100 mL |
| Detection Limit | 0.1 g/100 mL |
| Accuracy | ±2% |
| Display | Backlit LCD with Chinese UI |
| Control System | Embedded MCU with Data Logging, Parameter Configuration, Statistical Processing, and RS232 Communication |
| Sample Prep | Integrated Dedicated Pretreatment Module + Single-Use Reagent Cartridge Kit |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYN-1016SD |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% inhibition rate |
| Number of Channels | 16 |
| Measurement Error | ±5% |
| Limit of Detection (LOD) | 0.01–3.0 mg/kg |
| Light Source | High-brightness LED |
| Wavelength | 405 nm |
| Optical Stability | ±0.005 A/20 min |
| Operating Temperature | 5–40 °C |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz / Built-in Rechargeable Li-ion Battery |
| Data Storage | 32 GB internal + MicroSD expansion |
| Connectivity | Micro-USB, Micro-HDMI, Wi-Fi, GPRS/EDGE |
| OS | Embedded Windows-based interface |
| Brand | Jilin University–Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYN-106SD |
| Detection Limit | 0.1–3.0 mg/kg |
| Inhibition Rate Range | 0–100% |
| Measurement Accuracy | ±10% |
| Sample Throughput | 6 samples per run |
| Assay Time | ≤13 minutes per batch |
| Compliance Standard | GB/T 5009.199–2003 |
| Display | Backlit LCD with Chinese UI |
| Control System | Embedded MCU with data logging and statistical processing |
| Sample Prep | Integrated dedicated pretreatment kit and single-use reagent cartridges |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYN-110SA |
| Detection Method | Enzyme Inhibition Assay |
| Number of Channels | 10 |
| Temperature Display Accuracy | ±0.5 °C |
| Colorimetric Timing Precision | ±1 s |
| Standard Reaction Time | 3 min |
| Input Voltage | 100–240 V AC |
| Rechargeable Battery Runtime | 100–150 min |
| Adjustable Incubation Time Range | 1–99 min |
| Operating Environment | Indoor & Vehicle-Mounted |
| Operating Temperature Range | 0–40 °C |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-210SD |
| Function Type | Single-Analyte Detection System |
| Sample Compatibility | Multi-Matrix Food Samples |
| Detection Limit | 50.0 mg/kg |
| Quantification Range | 0.0–2000.0 mg/kg |
| Measurement Accuracy | ±5% (relative standard deviation under controlled conditions) |
| Control System | Embedded MCU-based platform |
| Data Interface | RS-232 and USB 2.0 |
| Display | Backlit LCD with Chinese UI |
| Portability | Handheld form factor, <1.2 kg |
| Brand | JiDa-Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Manufacturer |
| Region Category | Domestic (China) |
| Model | GDYN-200S |
| Product Type | True Protein Analyzer |
| Measurement Principle | Colorimetric Protein Assay (Biuret-based) |
| Measurement Range | 0.5–4.0% (liquid milk) |
| Detection Limit | 0.5% (liquid milk) |
| Precision | ±3% RSD |
| Light Source | Silicon Photodiode |
| Operating Temperature | 15–35 °C |
| Power Supply | 220 V AC, 50 Hz |
| Interface | RS-232 / USB |
| Data Output | Integrated thermal printer + digital export |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-1100M |
| Price Range | USD 1,400 – 7,200 |
| Detection Parameters | Moisture (0.0–27.0%), Fructose + Glucose (0.0–76.0%), Sucrose (0.0–12.0%), Acidity (0.0–100.0 mL/kg), Hydroxymethylfurfural (HMF) (0.0–100.0 mg/kg), Diastase Activity (0.0–25.0 mL/(g·h)) |
| LOD | Moisture: 12.0%, Fructose + Glucose: 13.0%, Sucrose: 3.0%, Acidity: 4.0 mL/kg, HMF: 1.0 mg/kg, Diastase Activity: 1.0 mL/(g·h) |
| Accuracy | ±2% |
| Interface | RS-232 / USB |
| Display | Backlit LCD with Chinese UI |
| Data Handling | Onboard storage, PC connectivity, statistical analysis |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYQ-1400S |
| Function Type | Single-Analyte Immunoassay Platform |
| Sample Versatility | Multi-sample Compatible (Liquid Food Matrices) |
| Wavelength Range | 400–700 nm |
| Throughput | 96-well plate in 5 seconds |
| Optical Resolution | 0.001 A (display), 0.0001 A (internal calculation) |
| Photometric Linearity | ±1% (0.000–2.000 A) |
| Absorbance Measurement Range | 0.0000–4.0000 A |
| Plate Formats | Standard 96-well and 48-well microplates |
| Filter Positions | Fixed 405 nm, 450 nm, 492 nm, 630 nm + 4 configurable slots |
| Detection Methodology | Single-, Dual-, and Multi-wavelength ELISA photometry |
| Data Processing Algorithms | Linear, Semi-log, 4PL, 5PL, Polynomial, Parabolic, Spline Curve Fitting |
| Plate Shaking | Adjustable speed and duration |
| Interface | RS232 serial port, parallel port |
| Power Supply | AC 220 V / 110 V ±22 V, 50 Hz / 60 Hz ±1 Hz |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | GDYQ-6000S |
| Function Type | Single-Analyte Quantitative Detection |
| Sample Versatility | Multi-Sample Compatible |
| Optical Detection Wavelength | 400 nm |
| Detection Channels | 1 |
| Lower Detection Limit | 10.0 mg/kg |
| Quantification Range | 0.0–1000.0 mg/kg |
| Measurement Accuracy | ±2% |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYQ-110SU |
| Function Type | Single-Analyte Quantitative Detection |
| Sample Type | Dedicated to Wheat Flour Matrix |
| Wavelength | 538 nm |
| Detection Limit | 5.0 mg/kg |
| Measurement Range | 5.0–100.0 mg/kg |
| Accuracy | ±5% |
| Light Source | High-Brightness LED |
| Power Supply | DC 9 V |
| Dimensions | 190 × 110 × 95 mm |
| Weight | 0.4 kg |
| Included | Sample Pretreatment Kit (1 set), Reagent Kit (50 assays) |
Show next