- All
- Favorite
- Popular
- Most rated
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GDYK-401RC |
| Detection Principle | Colorimetric Method |
| Measurement Range | Formaldehyde: 0.00–2.00 mg/m³ |
| Ammonia | 0.00–5.00 mg/m³ |
| Benzene & BTEX | 0.00–1.00 mg/m³ |
| TVOC | 0.00–4.00 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Repeatability | ≤ ±5% |
| Sampling Method | Pump-aspirated |
| Response Time (Formaldehyde) | 22 min |
| Operating Temperature | 10–40 °C |
| Relative Humidity Range | 15–95% RH |
| Detection Limits | Formaldehyde: 0.01 mg/m³ |
| Ammonia | 0.10 mg/m³ |
| Benzene & BTEX | 0.05 mg/m³ |
| TVOC | 0.05 mg/m³ |
| Brand | Jilin University-Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYK-W100S |
| Price Range | USD 700–1,400 (FOB) |
| Measurement Principle | Colorimetric Method |
| Measurement Range | 0.00–2.00 ppm |
| Resolution | 0.1 ppm |
| Repeatability | ≤ ±5% |
| Sampling Method | Pump-Aspiration |
| Response Time | 5–15 minutes |
| Operating Temperature | 0–25 °C |
| Relative Humidity Range | 15–90% RH |
| Brand | Jiada Xiaotian’e |
|---|---|
| Model | GDYK-201S |
| Principle | Colorimetric Method (Acetylacetone Derivatization) |
| Measurement Range | 0.00–1.00 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Repeatability | ≤ ±5% |
| Sampling Method | Pump-Aspiration with Flow Calibration |
| Response Time | 22 min |
| Operating Temperature | 10–40 °C |
| Relative Humidity Range | 15–95% RH |
| Light Source | High-Brightness LED @ 630 nm |
| Power Supply | DC 9 V (Alkaline Battery) |
| Auto-Shutdown | After 30 min Inactivity |
| Built-in Calibration Curve | Yes |
| Sample Vessel | 19 mm Graduated Cuvette (Reaction + Measurement in One) |
| Brand | JiDa-Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GDYK-202S |
| Detection Principle | Colorimetric Method (MBTH-based spectrophotometry) |
| Measurement Range | 0.00–1.00 mg/m³ (at 10 L sampling volume) |
| Sampling Method | Pump-aspiration |
| Light Source | High-brightness LED |
| Wavelength | 630 nm |
| Detection Limit | 0.01 mg/m³ (at 10 L sampling volume) |
| Accuracy | ±5% |
| Power Supply | 9 V rechargeable lithium battery |
| Compliance | GB/T 18204.2–2014 |
| Brand | Jiada Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYJ-201MA |
| Detection Principle | Colorimetric Method (Acetylacetone-Based Chromogenic Reaction) |
| Measurement Range | Textiles: 0.00–500.00 mg/kg |
| Engineered Wood & Furniture | 0.00–5.00 mg/L |
| Adhesives | 0.00–0.50 g/kg |
| Coatings & Paints | 0.00–1.25 g/kg |
| Ambient Air | 0.00–1.00 mg/m³ |
| Detection Limit | Textiles: 5.00 mg/kg |
| Engineered Wood & Furniture | 0.05 mg/L |
| Adhesives | 5.0 × 10⁻³ g/kg |
| Coatings & Paints | 1.25 × 10⁻² g/kg |
| Air | 0.01 mg/m³ |
| Response Time | ≤15 min |
| Accuracy | ±5% of Full Scale |
| Display | Backlit LCD with Chinese UI |
| Control System | Embedded Microcontroller |
| Sample Prep | Integrated Pre-treatment Module + Single-Use Reagent Cartridges |
| Output | Direct Concentration Readout (mg/kg, mg/L, g/kg, or mg/m³) |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYK-211M |
| Detection Principle | Colorimetric Method |
| Measurement Range | Formaldehyde: 0.00–1.00 mg/m³ |
| BTEX (Benzene, Toluene, Ethylbenzene, Xylenes) | 0.00–1.00 mg/m³ |
| TVOC | 0.00–4.00 mg/m³ |
| Detection Limit | Formaldehyde: 0.01 mg/m³ |
| BTEX | 0.05 mg/m³ |
| TVOC | 0.05 mg/m³ |
| Accuracy | ±5% |
| Power Supply | 9 V alkaline battery (≥40 h continuous operation) |
| Auto-power-off | After 10 min inactivity |
| Dimensions & Weight | Compact, handheld design (<200 g) |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYJ-201MC |
| Principle | Colorimetric Method |
| Measurement Ranges | Adhesives: 0.00–1.25 g/kg |
| Furniture & Engineered Wood | 0.0–5.0 mg/L (Desiccator Method) |
| Detection Limits | Adhesives: 0.01 g/kg |
| Furniture & Engineered Wood | 0.1 mg/L (Desiccator), 0.1 mg/100g (Perforator), 0.05 mg/m³ (Climate Chamber) |
| Accuracy | ±5% |
| Light Source | High-Brightness LED |
| Wavelength | 412 nm |
| Power Supply | AC 220 V ±22 V, 50 Hz ±1 Hz |
| Rechargeable Battery | 7.4 V, 900 mAh |
| Dimensions | 310 × 225 × 125 mm |
| Weight | 1.7 kg |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYJ-201SP2 |
| Principle | Colorimetric Method (Acetylacetone for Formaldehyde |
| Measurement Range | Formaldehyde: 0.0–125.0 mg/kg |
| Hexavalent Chromium | 0.0–50.0 mg/kg |
| Detection Limits | Formaldehyde: 5.0 mg/kg |
| Cr(VI) | 1.5 mg/kg |
| Accuracy | ±5% |
| Operating Temperature | 10–40 °C |
| Power Supply | 220 V, 50/60 Hz |
| Dimensions | 465 × 280 × 160 mm |
| Weight | 3.0 kg |
| Interface | USB |
| Integrated Thermal Printer | Yes |
| Prepackaged Sample Prep Kit | Yes |
| Brand | Jiada Xiaotianshe |
|---|---|
| Model | JCL-01 |
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Compliance | GB/T 18204.26–2000 |
| Detection Principle | Spectrophotometric Colorimetry (Phenol Reagent Method) |
| Lower Detection Limit | 0.1 mg/m³ |
| Measurement Range | 0.0–1.0 mg/m³ |
| Accuracy | ±10% |
| Analysis Time | ~2 hours per sample |
| Format | Single-use reagent kit with visual colorimetric readout using standardized chromatic scale card |
| Brand | JiDa Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Model | GDYJ-501SP |
| Measurement Range | Formaldehyde: 0.0–125.0 mg/kg |
| Hexavalent Chromium | 0.0–50.0 mg/kg |
| Wavelengths | 412 nm (formaldehyde), 540 nm (Cr(VI)) |
| Detection Limits | Formaldehyde: 2.0 mg/kg |
| Cr(VI) | 0.5 mg/kg |
| Accuracy | ±5% |
| Operating Temperature | 10–40 °C |
| Power | 5 W |
| Input Voltage | AC 220 V ±10%, 50 Hz ±1 Hz |
| Display | 5″ color TFT touchscreen + 2.9″ e-ink customizable standby screen |
| Data Storage | ≥10,000 test records with conditional search |
| Connectivity | USB 2.0, RS232, Bluetooth (for wireless thermal printer) |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYK-208SA |
| Price Range | USD 700–1,400 (FOB) |
| Measurement Principle | Colorimetric Method (Acetylacetone Derivatization) |
| Measurement Range | 0.00–1.00 mg/m³ (6 L air sample) |
| Detection Limit | 0.01 mg/m³ |
| Optical Source | High-Brightness LED |
| Wavelength | 635 nm |
| Accuracy | ±5% FS |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% |
| Rechargeable Battery | 7.4 V, 900 mAh |
| Brand | JiDa-Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYK-200M |
| Measurement Principle | Colorimetric Method (Phenol Reagent & AHMT Methods) |
| Measurement Range | 0.00–1.00 mg/m³ |
| Sampling Method | Pump-Aspiration |
| Compliance | GB 50325-2020 (Standard for Indoor Environmental Pollution Control in Civil Building Engineering) |
| Calibration Capability | User-Defined Calibration Curve Generation |
| Interface | Local Display + PC Connectivity |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GDYJ-201SC |
| Price Range | USD 1,400–2,800 (estimated) |
| Measurement Principle | Colorimetric Method |
| Detection Limit | 0.05 mg/L |
| Measurement Range | 0.00–5.00 mg/L |
| Accuracy | ±5% |
| Display | Backlit LCD with Chinese UI |
| Control System | Embedded Microcontroller |
| Data Functions | Real-time measurement, parameter setting, data logging, statistical analysis, USB communication |
| Sample Prep | Dedicated extraction apparatus + single-use reagent kits |
| Compliance | GB 18580–2001, GB 18584–2001 |