| Brand | RapidXAFS |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Model | RapidXAFS 1M |
| Price Range | USD 420,000 – 700,000 |
| X-ray Source Power | 1.6 kW & 3.0 kW |
| Monochromatic X-ray Photon Flux | 1,000,000 photons/s/eV |
| Minimum Detectable Elemental Concentration | 1 wt% |
| Tunable X-ray Absorption Energy Range | 4.5 keV – 15 keV (extendable) |
| Brand | RapidXAFS |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RapidXAFS 2M |
| Price Range | USD 700,000 – 1,400,000 |
| X-ray Source Power | 1.6 kW & 3.0 kW |
| Monochromatic X-ray Photon Flux | > 2,000,000 photons/s/eV at 8 keV |
| Minimum Detectable Elemental Concentration | 0.5 wt% (on CN-supported matrix) |
| Tunable X-ray Absorption Energy Range | 4.5 keV – 20 keV |
| Brand | RapidXAFS (Anhui Absorption Spectrometer) |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic |
| Model | RapidXAFS In Situ Cell |
| Price Range | USD 280,000–420,000 |
| X-ray Source Power | ≤100 W |
| Minimum Detectable Elemental Concentration | 1 wt% |
| X-ray Absorption Energy Range | 2.5–5 keV |
| XAFS Spectrum Acquisition Speed | 1 spectrum/s |
| Brand | RapidXAFS |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RapidXAFS Emission Spectrometer |
| Price Range | USD 390,000 – 490,000 |
| X-ray Source Power | ≤100 W |
| Minimum Detectable Elemental Content | ≤1 wt% |
| Tunable X-ray Absorption Energy Range | 2.5–5 keV |
| Fluorescence Detection Energy Range | 5–15 keV |
| Detectable Edges | 3d transition metal K-edges, 5d transition metal L-edges, actinide L-edges |
| Energy Resolution | ≤1.5 eV @ Cu Kα |
| Detector Efficiency | ≥1×10¹¹ counts per photon |
| Spectral Reproducibility | Energy drift <50 meV across repeated scans |
| Ambient Control | Helium-purged measurement chamber |
| Monochromator | High-purity Si or Ge single-crystal analyzer |
| In Situ Capability | Modular reaction cells for high/low temperature, multiphase catalysis, electrocatalysis, and operando studies |
| Data Acquisition | Real-time XES spectral output during acquisition |
| Brand | Raykol |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | AT200 |
| Pricing | Available upon request |
| Brand | Rayleigh |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-made) |
| Model | Elementis QQ Series |
| Instrument Type | Quadrupole Mass Spectrometer |
| Application Environment | Laboratory |
| Detection Principle | Inductively Coupled Plasma Ionization + Mass Separation via RF Quadrupole Filter |
| Detector | Digital/Analog Dual-Mode Electron Multiplier |
| Dynamic Range | 9–10 orders of magnitude |
| Mass Analyzer Material | Pure Molybdenum Quadrupole Rods |
| Ion Source | Self-Excited All-Solid-State RF Generator (Frequency-Matched Tuning) |
| Sample Introduction | Split-Type Torch with Auto-Alignment |
| Nebulizer Cooling | Thermoelectrically Cooled (TEC) Spray Chamber |
| Gas Control | On-line Argon Dilution System |
| Optional Oxygen Addition | Independent O₂ Combustion Module |
| Collision/Reaction Cell | Patented Hybrid Electric Field Collision/Reaction Cell (KED, CRC, and MR Mode Support) |
| Brand | Rayleigh |
|---|---|
| Origin | Beijing, China |
| Model | WQF-600N |
| Instrument Principle | Fourier Transform (FT) |
| Wavenumber Range | 3300–10000 cm⁻¹ |
| Spectral Resolution | < 4 cm⁻¹ |
| Wavenumber Accuracy | Better than half the set resolution |
| Transmittance Repeatability | ±0.5% T |
| Signal-to-Noise Ratio (S/N) | >10,000:1 (RMS, 32 scans at 4300–4400 cm⁻¹) |
| Beam Splitter | CaF₂ |
| Detector Options | DTGS (PbS, InGaAs optional) |
| Light Source | Air-cooled tungsten-halogen lamp |
| Data System | PC-based with Windows OS |
| Software | Full-featured FT-NIR acquisition, preprocessing, chemometric modeling, and spectral analysis suite compliant with ASTM E1655 and ISO 12099 |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | RC-800 |
| Pricing | Upon Request |
| Instrument Type | Flow Injection Analyzer (FIA) |
| Brand | Red Sun Instrument |
|---|---|
| Model | HR-280 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Temperature Control Range | Ambient to 300.0 °C (independently adjustable per bath) |
| Temperature Accuracy | ±0.1 °C (per bath) |
| Temperature Sensor | Imported Pt100 Platinum Resistance Thermometer |
| Heating Power | 1.5 kW (rated) |
| Bath Configuration | 4 independent metal heating baths |
| Stirring Speed | 1400 rpm |
| Timing Range | 0.01 s to 99 h 59 min |
| Display | 7-inch capacitive touch LCD with Chinese menu interface |
| Data Storage | Onboard non-volatile memory |
| Compliance | GB/T 7326–2016 (Petroleum Products — Determination of Copper Strip Corrosion) |
| Brand | Red Sun Instrument |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HRDZT-380 |
| Application | Wood Moisture & Insulation Resistance Testing |
| Resistance Range | 10² Ω to 10¹⁶ Ω (extendable to 10²⁰ Ω via current extrapolation) |
| Resistivity Range | up to 10²² Ω·cm |
| Voltage Accuracy | ±0.5% ±1 V |
| Measurement Speed | Fast mode — 5 readings/sec |
| Display | 4.3″ high-resolution TFT LCD |
| Interface | Banana jacks, BNC connectors |
| Compliance Reference | GB/T 10580–2003, IEC 60260, ASTM D257, ISO 3915 |
| Brand | Reilap |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Explorer |
| Pricing | Available Upon Request |
| Brand | Reilap |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | Novisar Apply Series |
| Price Range | USD 140,000 – 280,000 |
| Instrument Type | Triple Quadrupole |
| Application Scope | Specialized |
| Mass Range | 5–2000 amu (extendable to 5–2200 amu) |
| Sensitivity | (1) ESI+, MRM mode: 1 pg reserpine, S/N ≥ 1,200,000:1 (up to 2,000,000:1) |
| (2) ESI−, MRM mode | 1 pg chloramphenicol, S/N ≥ 1,200,000:1 (up to 2,000,000:1) |
| Resolution | 0.4–2 amu |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | inVia Basis |
| Instrument Type | Confocal Raman Microscope |
| Spectral Range | 100–4000 cm⁻¹ |
| Spectral Resolution | ≤1 cm⁻¹ |
| Spatial Resolution | XY ≈ 1 µm, Z ≈ 2 µm |
| Low-Wavenumber Limit | 10 cm⁻¹ |
| Spectral Reproducibility | ≤0.1 cm⁻¹ |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | inVia Qontor |
| Instrument Type | Confocal Raman Microscope |
| Spectral Range | 100–4000 cm⁻¹ |
| Spectral Resolution | ≤1 cm⁻¹ |
| Spatial Resolution | XY ≈ 1 µm, Z ≈ 2 µm |
| Low-Wavenumber Limit | 10 cm⁻¹ |
| Spectral Reproducibility | < ±0.1 cm⁻¹ |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | inVia Raman-AFM |
| Instrument Type | Confocal Micro-Raman Spectrometer with Integrated Atomic Force Microscopy |
| Spectral Range | 100–4000 cm⁻¹ |
| Spectral Resolution | ≤1 cm⁻¹ |
| Spatial Resolution | XY ≈ 1 µm, Z ≈ 2 µm |
| Low-Wavenumber Capability | down to 10 cm⁻¹ |
| Spectral Reproducibility | ≤0.1 cm⁻¹ |
| Coupling Architecture | Modular optical bridge for direct integration with third-party AFM/SPM platforms (e.g., Bruker Nano Surfaces, Nanonics, NT-MDT, JPK, Park Systems) |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | Raman-SCA-SEM |
| Instrument Type | Confocal Micro-Raman Spectrometer Integrated with Scanning Electron Microscope |
| Spectral Range | 100–4000 cm⁻¹ |
| Spectral Resolution | ≤1 cm⁻¹ |
| Spatial Resolution | XY ≈ 1 µm, Z ≈ 2 µm |
| Low-Wavenumber Capability | down to 10 cm⁻¹ |
| Spectral Reproducibility | ≤0.1 cm⁻¹ |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | inVia Reflex |
| Instrument Type | Confocal Raman Microscope |
| Spectral Range | 100–4000 cm⁻¹ |
| Spectral Resolution | ≤1 cm⁻¹ |
| Spatial Resolution | XY ≈ 1 µm, Z ≈ 2 µm |
| Low-Wavenumber Limit | 10 cm⁻¹ |
| Spectral Reproducibility | ≤0.1 cm⁻¹ |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | inVia™ InSpect |
| Instrument Type | Confocal Raman Microspectrometer |
| Spectral Range | 100–4000 cm⁻¹ |
| Spectral Resolution | ≤1 cm⁻¹ |
| Spatial Resolution | XY ≈ 1 µm, Z ≈ 2 µm |
| Low-Wavenumber Capability | down to 10 cm⁻¹ |
| Spectral Reproducibility | < ±0.1 cm⁻¹ |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | RA802 |
| Instrument Type | Confocal Micro-Raman Imaging System |
| Spectral Range | 100–3500 cm⁻¹ |
| Spectral Resolution | <2 cm⁻¹ |
| Spatial Resolution | ~500 nm |
| Minimum Wavenumber | 100 cm⁻¹ |
| Spectral Reproducibility | ≤±0.1 cm⁻¹ |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | RA816 |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 100–3500 cm⁻¹ |
| Spectral Resolution | 2 cm⁻¹ |
| Spatial Resolution | ~500 nm |
| Minimum Wavenumber | 100 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.1 cm⁻¹ |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | Virsa Raman Analyzer |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 50–4000 cm⁻¹ |
| Spectral Resolution | <2.5 cm⁻¹ |
| Spatial Resolution | XY <0.5 µm, Z <2 µm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | <±0.1 cm⁻¹ |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RHEODYNE 7725i |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | RI2001 |
| Price Range | USD 7,000–14,000 |
| Detector Type | Differential Refractometer (RID) |
| Wavelength Range | 160–1100 nm |
| Measurement Principle | Dual-Beam Optical Null Method |
| Light Source | Deuterium Lamp |
| Temperature Compensation | Automatic Real-Time |
| Data Output | Analog (±1 V, ±5 V, ±10 V) + Digital (RS-232/USB) |
| A/D Resolution | 16-bit |
| Zero Calibration | Motorized Auto-Zero with Solvent Flush Sequence |
| Reference Cell | Self-Cleaning Flow-Through Design |
| Thermal Stability | Integrated Isothermal Enclosure with Active Temperature Control (±0.01 °C) |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | Micro-Z |
| Instrument Type | Scanning WDXRF |
| X-ray Tube Power | 40 W |
| Elemental Range | S (Sulfur) |
| Compliance | ASTM D2622, ISO 20884, JIS K 2541-7 |
| Cooling | Air-cooled (no water or gas required) |
| Power Supply | 220 V AC, 2 A |
| Sample Preparation | None required |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | Mini-Z |
| Detection Principle | Wavelength Dispersive X-Ray Fluorescence (WDXRF) |
| Sample Throughput | 6-position automated sample changer |
| Power Requirement | 220 V AC, 2 A |
| Dimensions | 640 × 580 × 580 mm (W × D × H) |
| Weight | 65 kg |
| Detection Limit for S | 0.3 ppm |
| Precision (S at 10 ppm in gasoline) | σ = 0.17 ppm |
| S Quantification Range | 1 ppm – 4 wt% |
| Compliant Standards | ASTM D2622, ISO 20884, JIS K2541-7 |
| Cooling | Air-cooled (no water or gas required) |
| Operation Interface | Touchscreen control panel |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | Miniflex 600 |
| X-ray Tube Power | 600 W |
| Dimensions (W×H×D) | 560 × 700 × 395 mm |
| Weight | 80 kg |
| Goniometer Accuracy | ±0.01° 2θ |
| Safety | Interlocked X-ray shutter with automatic beam cutoff during sample loading |
| Detector | Standard scintillation counter |
| Sample Stage | Manual stage standard |
| Software Suite | PDXL (with ICDD PDF-4+ database), Qualitative & Quantitative Analysis modules, Multi-scan acquisition, Dust-specific quantification (e.g., respirable crystalline silica per ISO 16258-1, NIOSH 7500) |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | MiniFlex600 |
| Instrument Type | Powder X-ray Diffractometer |
| Power Rating | 0.0001 kW |
| Dimensions | 560 W × 460 D × 700 H mm |
| Detector Type | Advanced Semiconductor Detector |
| Software Suite | PDXL (Phase Identification, Quantitative Analysis, Rietveld Refinement, Crystal Structure Visualization) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Primus |
| Pricing | Upon Request |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | Simultix15 |
| Instrument Type | Simultaneous Multi-Channel WDXRF |
| X-ray Tube Power | 4 kW |
| Elemental Range | Beryllium (Be, Z=4) to Uranium (U, Z=92) |
| Simultaneous Channels | Up to 40 elements |
| Detector System | High-speed pulse-height-analyzed proportional counters with background subtraction circuitry |
| Vacuum System | Dual-stage vacuum pump with auto-stabilized vacuum control |
| Software | Multi-tasking, multi-window FP (Fundamental Parameters) quantification software with Chinese GUI (localized for operator interface only) |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Instrument Type | Powder X-ray Diffractometer |
| Model | SmartLab |
| X-ray Source | 3 kW or 9 kW sealed-tube generator |
| Anode Materials | Cu, Cr, Fe, Co, Ni, Mo, Ag, Au (selectable) |
| Goniometer Radius | 300 mm |
| Detector | HyPix-3000 2D pixel array detector |
| Optics | CBO-Auto (automated beam optics switching) and CBO-μ (high-resolution micro-beam optics) |
| Primary Source | PhotonMax high-brilliance X-ray tube |
| Software | SmartLab Studio II (with in-situ analysis modules) |