Chemical Analysis Instruments
Filter
Showing 3121–3150 of 4337 results
| Brand | Shanda |
|---|---|
| Origin | Shandong, China |
| Model | SD-ND600 |
| Wavelength Range | 185–910 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Resolution | ≤1.8 nm (FWHM at Hg 546 nm) |
| Absorbance Accuracy | ±1% (7.332 Abs at 260 nm) |
| Absorbance Precision | 0.002 Abs |
| Sample Volume | 0.5–2.0 µL |
| Pathlength Options | 0.02, 0.05, 0.1, 0.5, and 1.0 mm (automatically selected) |
| Measurement Time | ≤5 s per sample |
| Cuvette Mode OD600 Range | 0–4 A |
| dsDNA Quantitation Range | 2–38,880 ng/µL |
| BSA Protein Range | 0.06–820 mg/mL |
| Light Source | Pulsed Xenon Lamp (10-year lifetime) |
| Detector | 3648-pixel Linear CCD Array |
| Display | 7-inch Capacitive Touchscreen (Android OS) |
| Data Export | USB flash drive, SD-RAM card |
| Optional Fluorescence Module | Ex 460 nm / Em 525 nm |
| Dimensions (W×D×H) | 270 × 210 × 196 mm |
| Weight | 3.5 kg |
| Brand | Shanghai Fumi |
|---|---|
| Origin | Shanghai, China |
| Model | Flowstar 2020BJ |
| Product Type | Continuous Flow Analyzer (CFA) |
| Wavelength Range | 270–1100 nm |
| Sample Cup Capacity | 100 / 180 / 270 positions (5 mL, 8 mL, or 10 mL per cup) |
| Reagent Positions | 100 / 180 / 270 |
| Flow Cell Pathlength | 10 mm, 30 mm, 50 mm |
| Light Source | LED or Krypton Lamp |
| Brand | Shanghai Fumi |
|---|---|
| Origin | Shanghai, China |
| Model | Flowstar 2020FL |
| Product Type | Continuous Flow Analyzer (CFA) |
| Wavelength Range | 270–1100 nm |
| Sample Volumes | 5/8/10 mL per cup |
| Capacity | 100/180/270 positions |
| Reagent Positions | 100/180/270 |
| Flow Cell Path Lengths | 10 mm, 30 mm, 50 mm |
| Light Source | LED or Krypton Lamp |
| Brand | INESA |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FP6410 / FP640 / 6400A |
| Price | Upon Request |
| Measurement Range | 0–100 ppm |
| Response Time | < 8 s |
| Repeatability | ≤2% |
| Sample Flow Rate | < 4 mL/min |
| Brand | INESA |
|---|---|
| Origin | Shanghai, China |
| Model | GC190A |
| Column Temperature Stability | ±0.03 °C |
| UV Lamp Energy | 10.6 eV |
| Detection Limit | ≤1×10⁻¹¹ g/mL (benzene) |
| Measurement Range | 0.0–100 mg/m³ |
| Repeatability | ≤3% RSD |
| Baseline Noise | ≤20 µV |
| Baseline Drift | ≤500 µV/15 min |
| Warm-up Time | 1 h to operational stability |
| Power Supply | AC 220 V / 50 Hz |
| Dimensions | 190 mm × 385 mm × 350 mm |
| Weight | 12 kg |
| Operating System | Embedded Windows XP |
| Connectivity | Integrated Ethernet port |
| Detector Type | Photoionization Detector (PID) with 10.6 eV UV lamp |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-2500 |
| Optical Design | Dual-beam with dual detectors |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1, 0.2, 0.5, 1, 2, and 4 nm (selectable) |
| Wavelength Accuracy | ±0.3 nm |
| Stray Light | ≤0.01% T |
| Automation | Automatic wavelength scanning and energy calibration |
| Light Source | Imported deuterium and tungsten-halogen lamps |
| Software | Integrated PC-based acquisition and analysis platform with GLP-compliant data handling |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-3520AA |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Concave Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Self-Reversal Method |
| Compliance | Meets GB/T 21187–2007 (Chinese National Standard for AAS), ASTM E1941, ISO 8288 |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-3530AA |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Concave Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Self-Absorption Method |
| Background Correction Capacity | >80× |
| Software Platform | Win-AAS Workstation |
| Data Output Modes | Time-Averaged Signal, Peak Height, Peak Area, Statistical Summary |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-3590AA |
| Instrument Type | Flame and Graphite Furnace AAS |
| Optical System | Single-beam, All-reflective Achromatic Optics |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-reversal (Self-absorption) Method |
| Safety Features | Automatic Lamp Switching, Graphite Tube Auto-diagnosis, Multi-point Radiation Shielding |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-3801 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Absorption Method |
| Background Correction Efficiency | >50× (D₂), >100× (Self-Absorption) |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-3802 |
| Instrument Type | Graphite Furnace AAS |
| Optical System | Dual-beam |
| Monochromator | Plane Grating |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-absorption Method |
| Compliance | Designed for GLP/GMP-aligned laboratory workflows |
| Software | SPWin-AAS v3.x (Windows-based, 21 CFR Part 11-ready audit trail option) |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-3803AA (Parallel Configuration) |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Echelle Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal (Self-Absorption) Method |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories |
| Software | Integrated PC-based workstation with audit trail capability |
| Regulatory Alignment | Supports GLP/GMP data integrity requirements per FDA 21 CFR Part 11 principles |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-3887ZAA |
| Instrument Type | Flame–Graphite Furnace Hybrid AAS |
| Optical System | Single-beam |
| Monochromator | Not specified (conventional grating-based) |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Self-Absorption + Transverse AC Magnetic Field Zeeman Correction |
| Graphite Furnace Configuration | Integrated Horizontal DC-heated Furnace with Automatic Resistance Compensation |
| Background Correction Modes | Three-mode selectable (D₂, Self-Absorption, Zeeman) |
| Safety | Multi-level hardware interlocks, STPF-compliant temperature control platform, Full PC automation with real-time monitoring |
| Lamp System | Motorized 8-lamp turret with auto-alignment |
| Viewing System | Integrated furnace viewing camera (real-time graphite tube status monitoring) |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-722 |
| Optical System | Single-beam |
| Detector | Photocell |
| Wavelength Range | 325–1000 nm |
| Wavelength Accuracy | ±2 nm |
| Spectral Bandwidth | 5 nm |
| Stray Light | ≤0.5% T |
| Wavelength Adjustment | Manual |
| Compliance | CE-marked for laboratory use in accordance with IEC 61010-1 |
| Data Interface | RS-232 (optional USB adapter available) |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SP-723 |
| Optical System | Single-beam self-collimating optical path with 1200 lines/mm holographic grating |
| Detector | Photodiode array |
| Wavelength Setting | Automatic |
| Sample Chamber Capacity | Accommodates cuvettes from 5 mm to 100 mm pathlength |
| Minimum Sample Volume | 200 µL (with optional ultra-micro cuvette holder) |
| Display | 2-line × 20-character LCD |
| Data Output | Analog output + RS-232C serial interface |
| Compliance | Designed for educational, industrial QC, and environmental monitoring applications per standard laboratory practice guidelines (e.g., ISO/IEC 17025–aligned operation) |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | SP-752 |
| Price Range | USD 1,400–2,800 |
| Optical Design | Single-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Scanning Mode | Motorized Automatic Wavelength Selection |
| Wavelength Calibration | Self-Referencing Auto-Calibration via Spectral Feature Recognition |
| Displayed Parameters | Transmittance (%T), Absorbance (A), Concentration (c), Wavelength (nm) |
| Software Modules | Spectrum Scan, Kinetic (Time) Scan, Quantitative Analysis, Nucleic Acid (DNA/RNA) Analysis |
| Expandability | Modular Accessory Interface (e.g., cuvette holders, fiber-optic probes, temperature-controlled cells) |
| Compliance Framework | Designed to support GLP documentation workflows and basic ISO/IEC 17025 alignment for routine QC labs |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Model | SP-756P |
| Price Range | USD 4,200 – 7,000 (FOB Shanghai) |
| Optical Design | Dual-Beam with Ratio Monitoring |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Automatic |
| Spectral Bandwidth | 2 nm (nominal) |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | ≤0.05% T at 220 nm and 340 nm |
| Brand | Shanghai Tengba |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | Shanghai Tengba Instrument Co., Ltd. |
| Model | iTongue |
| Product Type | Electronic Tongue System (Taste Fingerprint Analyzer) |
| Sensor Technology | Pulsed Voltammetry-based Electrochemical Sensor Array |
| Data Analysis | Multivariate Pattern Recognition (PCA, SIMCA, PLS-DA, DFA, SVM, KNN, t-SNE, DBSCAN, BP Neural Network) |
| Sample Throughput | 40-position Automated Sampler |
| Detection Time per Sample | < 60 s |
| Sensor Material | Inert Noble Metal Electrodes |
| Electrode Lifetime | ≥ 10 years |
| Compliance | Designed for GLP-compliant sensory QA/QC workflows |
| Software | Proprietary TasteFinger™ Suite with Audit Trail & CFR Part 11-ready User Management |
| Brand | Shanghai Youke |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Graphite Furnace AAS |
| Optical System | Single-beam |
| Background Correction | Deuterium Lamp + Self-reversal (SR) Dual-mode |
| Resolution | 0.2 nm |
| Characteristic Mass (for Graphite Furnace) | 0.05 pg for 1% absorption (Ag) |
| Repeatability (RSD) | ≤3% |
| Lamp Positions | 8-position motorized rotatable turret |
| Software Platform | RG-WinAAS for Windows OS |
| Compliance Context | Designed to support GLP-compliant workflows with audit-ready data logging and instrument parameter traceability |
| Brand | Shanghai Youke |
|---|---|
| Origin | Shanghai, China |
| Model | T-N6000SPlus |
| Optical System | Dual-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 0.5 / 1 / 2 / 4 / 5 nm (selectable) |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ±0.1 nm |
| Stray Light | ≤0.02% T at 220 nm & 360 nm |
| Display | 7-inch color TFT-LCD touchscreen |
| Data Storage | Internal 8 GB flash memory (supports ≥5000 absorbance readings or 500 calibration curves) |
| Processor | 32-bit ARM Cortex-M3 @ 120 MHz |
| Lamp Life | ≥2000 h (tungsten & deuterium lamps, auto-switched) |
| Grating | 1200 lines/mm holographic plane grating |
| Sample Compartment | Extra-large, compatible with 5-cell wide rack and 8-position rotating carousel |
| Connectivity | RS-232 printer port, USB Host (Type-B), USB Device (Type-A), optional Ethernet/WiFi module |
| Data Export Formats | .CSV, .QUA, .TXT, .BMP |
| Software | PC-based spectral acquisition & analysis suite with GLP-compliant audit trail, method validation tools, and FDA 21 CFR Part 11-ready optional modules |
| Brand | ShangHaiYousufu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 12.7 mm OD × 0.89 mm Wall Thickness |
| Tube Material | ASTM A269/A270 Grade 316L Stainless Steel |
| Surface Finish | Bright Annealed (BA) |
| Outer Diameter Tolerance | ±0.02 mm |
| Outer Surface Roughness | Ra ≤ 0.4 µm |
| Compliance Standards | GB/T 12771, ASTM A269, ASTM A270, JIS G3446, DIN 17456 |
| Packaging | Non-woven Fabric Wrapped, Sealed in Plastic Caps |
| Brand | Shaw |
|---|---|
| Origin | United Kingdom |
| Model | SADP-D |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Electrolytic (P2O5) Sensor |
| Operating Temperature | -20 °C to +40 °C |
| Accuracy | ±3 °C to ±4 °C |
| Repeatability | ±0.5 °C |
| Dew Point Range | -100 °C to +20 °C |
| Display | Backlit LCD (°C/°F selectable) |
| Power Supply | Standard C-cell batteries |
| Battery Life | >150 hours continuous operation |
| Certification | ATEX II 2G Ex ia IIC T4 Ga, IECEx EXA 22.0001X |
| Calibration | NIST-traceable certificate included |
| Accessories | 2 m PTFE sampling hose, leather carry case with shoulder strap, desiccant-dried test chamber, user manual |
| Brand | Shaw |
|---|---|
| Origin | United Kingdom |
| Model | SDA-P |
| Type | Online Dew Point Meter |
| Principle | Chilled Mirror (Electrochemical Sensor Variant) |
| Operating Temperature | -20 °C to +50 °C |
| Accuracy | ±3 °C |
| Repeatability | ±3 °C |
| Measuring Range | -100 °C to 0 °C |
| Display | 3½-digit backlit LCD |
| Output | 4–20 mA analog signal, dual relay alarms (240 V AC @ 3 A) |
| Power Supply | 220 V AC, 50 Hz |
| Installation | Panel mount (cutout: 135 mm × 66 mm × 175 mm depth) |
| Sample Pressure | 1–30 psi (up to 200 bar sensor-rated) |
| Sample Flow Rate | 1–5 L/min (recommended: 1 L/min) |
| Gas Connection | 1/4" or 1/8" compression fittings |
| Intrinsic Safety | Sensor certified intrinsically safe |
| Calibration | Automatic 1-minute ambient air zero calibration |
| Compliance | ISO 9002 quality management system |
| Brand | Haoyuan |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | XAFS2300+ |
| X-ray Source Power (XAFS mode) | 3 kW |
| X-ray Source Power (XES mode) | 50 W |
| Monochromatic Photon Flux | > 2 × 10⁶ photons/sec (at 7–9 keV) |
| Minimum Detectable Elemental Concentration | ≥ 1 wt% |
| Tunable X-ray Absorption Energy Range | 4.5–25 keV |
| Energy Resolution | 0.5–3 eV |
| Energy Scale Drift Reproducibility | < 50 meV per measurement session |
| Monochromator Architecture | Spherical-bent crystal on high-precision Rowland-circle geometry |
| Detector | High-resolution silicon drift detector (SDD) |
| Brand | Sherwood |
|---|---|
| Origin | United Kingdom |
| Model | M410 |
| Element Detection | Na, K, Li, Ca, Ba |
| Output Units | ppm, mg/L |
| Compliance | ISO 7635, ASTM D2189, USP <731> |
| Software Interface | RS-232 serial output for data logging |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 5D Ultra-e |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Chromatography Configuration | Comprehensive Two-Dimensional Gas Chromatography (GC×GC) Coupled with Online Liquid Chromatography (LC) |
| Mass Range | m/z 2–1090 |
| Resolution | Unit Mass Resolution |
| Sensitivity | >15,000:1 (S/N, peak-to-peak, at 1 pg OFN) |
| Scan Speed | 20,000 u/s |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Flame and Graphite Furnace AAS |
| Wavelength Range | 185–900 nm |
| Monochromator | Czerny-Turner with 1800 grooves/mm grating |
| Spectral Bandwidth | 0.2, 0.7, 1.3, 2.0 nm (4-step automatic switching) |
| Optical System | Dual-beam for flame mode |
| Detector | Photomultiplier tube (PMT) |
| Background Correction | Simultaneous deuterium lamp (BGC-D₂, 185–430 nm) and fast self-reversal (BGC-SR, 185–900 nm) |
| Lamp Holder | 6-position, dual-lamp operation (1 pre-heating) |
| Dimensions (AA-7000F) | 700 × 588 × 714 mm, 72 kg |
| Dimensions (AA-7000G) | 700 × 580 × 538 mm, 65 kg |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Operating Environment | 10–35 °C, 20–80% RH (≤70% above 30 °C) |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | AA-7800 |
| Price Range | USD 42,000 – 85,000 (FOB China) |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal Method |
| Spectral Resolution | 0.1 nm |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory FTIR Microscope |
| Resolution | 0.25 cm⁻¹ |
| Signal-to-Noise Ratio | 30,000:1 |
| Optical Magnification Range | 330× continuous (macro to micro, 10 mm × 13 mm to 30 µm × 40 µm) |
| Detector | Liquid Nitrogen-Cooled MCT (Mercury Cadmium Telluride) |
| Automation | Fully Motorized XYZ Stage with Digital Image-Based Auto-Targeting |
| Software | IRsolution with Integrated Chemical Imaging and Automated Contaminant Identification Algorithm |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | AIRsight |
| Instrument Type | Laboratory Benchtop System |