| Brand | GBPI |
|---|---|
| Model | ZF1800C |
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Category | Other General Analytical Instruments |
| Measurement Range | 0.2–167,000 mg/dm² |
| Resolution | 0.0001 g/dm² |
| Balance Capacity | 0–200 g |
| Balance Resolution | 0.1 mg |
| Water Bath Temp Control | Ambient to 100 °C |
| Heating Chamber Temp Control | Ambient to 120 °C |
| Cooling Chamber Temp Control | Ambient |
| Temp Accuracy | ±0.5 °C |
| Chamber Temp Uniformity | ±5 °C |
| Sample Capacity | 1–18 independent test positions |
| Gravimetric Constant-Weight Duration | 2.5 h (standard) |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (L×W×H) | 180 cm × 90 cm × 120 cm |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 5000 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | ZF1800D |
| Pricing | Upon Request |
| Measurement Range | 0.2–167,000 mg/dm² |
| Resolution | 0.0001 g/dm² |
| Balance Capacity | 0–200 g |
| Balance Resolution | 0.1 mg |
| Water Bath Temp Control | Ambient to 100 °C |
| Heating Chamber Temp Control | Ambient to 120 °C |
| Cooling Chamber Temp Control | Ambient |
| Temp Accuracy | ±0.5 °C |
| Chamber Temp Uniformity | ±5 °C |
| Sample Capacity | 1–18 independent test positions |
| Gravimetric Stabilization Time | 2.5 h (standard) |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (L×W×H) | 180 × 90 × 120 cm |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 5000 W |
| Brand | GBPI |
|---|---|
| Model | ZF3800A |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Measuring Range | 0.167–167,000 mg/dm² |
| Resolution | 0.0001 mg/dm² |
| Balance Capacity | 0–200 g |
| Balance Readability | 0.1 mg |
| Water Bath Temp. Control | 68.3–100 °C |
| Heating Chamber Temp. Control | 68.3–117.9 °C |
| Cooling Chamber Temp. Control | <27.5 °C |
| Temperature Accuracy | ±3 °C |
| Sample Capacity | 1–18 independent test positions |
| Gravimetric Constant-Weight Duration | 2.5 h (standard) |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (L×W×H) | 180 × 90 × 120 cm |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 1500 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Model | ZF800A |
| Testing Capacity | 8 independent stations (expandable to 36) |
| Residue Mass Range | 0–80 g |
| Weighing Accuracy | 0.2 mg |
| System Resolution | 0.1 mg |
| Temperature Control Range | 80–130 °C |
| Temperature Stability | ±0.2 °C |
| Hot Air Circulation Velocity | 0.2 m/s |
| Sample Volume per Vessel | 0–200 mL |
| Evaporation Vessel Capacity | 230 mL (included ×8) |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 4000 W |
| Dimensions (W×D×H) | 937 × 660 × 830 mm |
| Interface Fittings | 1/8″ stainless steel tubing & Φ6 mm polyurethane tubing |
| Standard Accessories | Dedicated software, communication cable, 200 g calibration weight, Φ8 mm PU air tube |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Model | ZF800A |
| Measurement Range | 0–80 g (residue mass) |
| Accuracy | 0.1 mg |
| Resolution | 0.01 mg |
| Temperature Control Range | 80–150 °C (typical operating range: 100–130 °C) |
| Temperature Stability | ±0.1 °C (typical: ±0.2 °C) |
| Hot Air Circulation Velocity | 0.2 m/s |
| Sample Volume Capacity | 0–500 mL |
| Chamber Volume | 86 L |
| Independent Test Stations | 1–8 (expandable to 36) |
| Gas Supply | Compressed air |
| Pressure Requirement | 0.6 MPa |
| Tubing Interface | Φ6 mm polyurethane |
| Power Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Model | ZF900B |
| Origin | Guangdong, China |
| Manufacturer | GBPI Packaging Instruments Co., Ltd. |
| Measurement Range | 0–80 g (residue mass) |
| Weighing Accuracy | ±0.2 mg |
| System Resolution | 0.1 mg |
| Temperature Control Range | Ambient to 130 °C |
| Temperature Stability | ±0.2 °C |
| Air Circulation Velocity | 0.2 m/s |
| Sample Volume Capacity | 0–200 mL per vessel |
| Independent Test Positions | 8 |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 1000 W |
| Dimensions (W×D×H) | 937 × 660 × 830 mm |
| Brand | GBPI |
|---|---|
| Model | ZF900C |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Compliance Standards | GB/T 5009.60–2003, GB/T 5009.64–2003, GB/T 5009.68–2003, GB/T 5009.69–2008, GB/T 5009.203–2003, GB/T 9740–2008 |
| Residue Mass Range | 0–80 g |
| Weighing Accuracy | ±0.2 mg |
| Resolution | 0.1 mg |
| Temperature Control Range | Ambient to 130 °C |
| Temperature Stability | ±0.2 °C |
| Air Circulation Velocity | 0.2 m/s |
| Sample Volume Capacity | 0–200 mL per vessel |
| Independent Test Stations | 8 |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 1000 W |
| Dimensions (W×D×H) | 937 × 660 × 830 mm |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory FTIR Spectrometer |
| Spectral Range | 7800–350 cm⁻¹ |
| Resolution | <1.0 cm⁻¹ |
| Scan Speed | 4 cm⁻¹ |
| Signal-to-Noise Ratio | 15,000:1 / 30,000:1 (at 4 cm⁻¹, 1 min scan) |
| Beamsplitter | KBr substrate with Ge coating |
| Detector | Imported high-sensitivity deuterated L-alanine triglycine sulfate (DLaTGS) |
| Source | Imported long-life, air-cooled high-intensity IR source |
| Interferometer | Sealed 30°-incidence Michelson interferometer with built-in auto-alignment optics |
| A/D Conversion | 24-bit, 500 kHz |
| Communication Interface | USB 2.0 (backward compatible with USB 3.0) |
| Dimensions | 450 × 350 × 235 mm (L×W×H) |
| Weight | 14 kg |
| Operating Temperature | 15–35 °C |
| Power Consumption | <30 W |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | GC-4008B |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Domain | Coal Mining Safety & Spontaneous Combustion Monitoring |
| Detection Systems | TCD, Dual FID, ECD, FPD |
| Column Configuration | Four Dedicated Capillary/Packed Columns |
| Temperature Program | 10-Stage Programmable Ramp |
| Carrier Gases | Helium (TCD), Hydrogen/Air (FID), Nitrogen (ECD/FPD) |
| Minimum Detectable Concentrations | CO, C₂H₂ ≤ 0.5 ppm |
| [Brand | Chrom |
|---|---|
| Origin | Zhejiang, China |
| Model | GC-5190PDD |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | Ultra-High-Purity Gas Analysis |
| Oven Temperature Range | 4°C above ambient to 450°C |
| Max. Ramp Rate | 60°C/min |
| Carrier Gas Flow Control Range | 30–35 mL/min |
| Carrier Gas Pressure Control Range | 0.35–0.55 MPa |
| Injector Max. Temp. | 450°C |
| Injector Pressure Setting Range | 0–100 psi |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| PDHID Detection Limit (CH₄) | ≤3.5×10⁻¹³ g/mL |
| PDHID Dynamic Linear Range | ≥10⁷ |
| PDHID Noise | <0.1 pA |
| PDHID Drift | ≤1.0 pA/30 min |
| PDHID Repeatability (CH₄) | ≤3.0% RSD |
| Column Oven Temp. Stability | ±0.02°C |
| Programmable Temperature Steps | 9 ramps / 10 plateaus |
| Max. Program Duration | 9999.9 min] |
| [Brand | Lunan Ruihong |
|---|---|
| Origin | Shandong, China |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 4 °C to 450 °C |
| Ramp Rate | 0.1–80 °C/min |
| Cool-down Rate | ≤3 min (200 °C → 100 °C) |
| Carrier Gas Flow Control Range | 0–1000 mL/min |
| Carrier Gas Pressure Control Range | 0–100 psi |
| Injector Max Temp | 450 °C |
| Injector Pressure Setpoint Range | 0–100 psi |
| Temperature Zones | 8 independent zones |
| Programmed Temperature Steps | up to 16 ramps |
| Detector Options | FID, TCD, ECD, FPD, NPD (up to 3 simultaneously)] |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Titan Instruments |
| Type | Domestic |
| Model | GC-IMS 1000 |
| Pricing | Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic Lab-Scale GC |
| Model | GC9802-T |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Food Industry–Specific |
| Oven Temperature Range | Up to 400 °C |
| Oven Ramp Rate | 0–40 °C/min |
| Injector Maximum Operating Temperature | Up to 400 °C |
| Detector | FID (Hydrogen Flame Ionization Detector), optional alternative detectors available |
| FID Sensitivity | Mt ≤ 1 × 10⁻¹¹ g/s (n-hexadecane) |
| Baseline Drift | ≤ 0.02 mV/h |
| Noise | ≤ 0.02 mV |
| Column | OV-1701 capillary column (50 m × 0.32 mm × 0.5 µm), max. temp. 400 °C |
| Injector Type | Capillary inlet (packed column inlet optional) |
| Oven Dimensions | 240 × 210 × 240 mm (W × D × H) |
| Temperature Control Accuracy | ±0.1% |
| Temperature Resolution | 0.1 °C |
| Carrier Gas | High-purity N₂ (99.99%, 0.4 MPa, dried) |
| H₂ Supply | 99.99% purity, 0.4 MPa, dried |
| Air Supply | 0.4 MPa, dried and oil-free |
| Gas Line Connection | Φ3 mm tubing |
| External Dimensions | 500 × 550 × 500 mm (H × W × D) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC9802-Y |
| Application Scope | General-purpose EO residue testing in medical devices and packaging |
| Detector | Flame Ionization Detector (FID), optional alternative detectors available |
| Detection Limit | ≤3×10⁻¹² g/s (n-hexadecane) |
| Baseline Noise | ≤2×10⁻¹⁴ A |
| Baseline Drift | ≤1×10⁻¹³ A/30 min |
| Column | 30 m × 0.32 mm × 0.5 µm EO-specific capillary column (optional columns available) |
| Headspace Autosampler | 20-position |
| Oven Dimensions | 240 × 210 × 240 mm |
| Temperature Range | 4 °C above ambient to 450 °C (1 °C increments) |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Gradient Uniformity | ±1% |
| Independent Temperature Zones | 6-channel oven, inlet, detector, and auxiliary zones |
| Programmed Temperature Ramp | Up to 16 steps, ramp rate 0.1–60 °C/min |
| Maximum Runtime Setting | 6000 min |
| Carrier Gas | High-purity nitrogen (99.999%, supplied externally) |
| Hydrogen Generator (optional) | 300 mL/min, purity ≥99.999% |
| Air Generator (optional) | Oil-free, dehydrated & deoiled, 3 L/min |
| Injection System | Split/splitless capillary injector with septum purge |
| Software | Dual-channel Chinese-language chromatography workstation with instrument control, real-time plotting, peak integration, calibration curve generation, PDF report export, and audit-ready data logging |
| Brand | Kunyuan Instruments |
|---|---|
| Origin | Tianjin, China |
| Model | Sparkle |
| Cooling | Liquid Nitrogen (Ambient Pressure) |
| Resolution Modes | 400 / 4000 / 10,000 (switchable in <1 s) |
| Detection Limit | Sub-ppb (typical), down to low-ppt (element-dependent) |
| Dynamic Range | 12 decades (Faraday cup + electron multiplier) |
| Sample Throughput | Full-element scan (78 elements) <5 min |
| Depth Resolution | Sub-micrometer |
| Gas Consumption | Ar, ≥99.9995% purity |
| Dimensions | 2160 × 2040 × 1480 mm (L×W×H) |
| Power | AC 220 V / 50 Hz, grounding resistance <2 Ω |
| Cooling | External chiller (500 W) for turbo pumps & magnet |
| Ambient | 18–24 °C, 40–60% RH |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | GDA 150 HR |
| Price Range | USD 210,000 – 280,000 |
| Brand | GDANA |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | SPEAR 500 |
| Pricing | Upon Request |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | GdScO₃ Crystal Substrate |
| Pricing | Upon Request |
| Crystal Structure | Orthorhombic (a = 5.45 Å, b = 5.75 Å, c = 7.93 Å) |
| Melting Point | 2127 °C |
| Density | 6.6 g/cm³ |
| Growth Method | Czochralski (CZ) |
| Orientation | <110> ± 0.5° |
| Dimensions | 10 × 10 × 0.5 mm³ or 10 × 5 × 0.5 mm³ |
| Surface Finish | Single-side polished |
| Surface Roughness (Ra) | < 0.5 nm |
| Packaging | Vacuum-sealed in Class 100 cleanroom bags, stored and shipped from Class 1000 cleanroom environment |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYS-101SQ2 |
| Application | On-site quantitative determination of Chemical Oxygen Demand (COD) in industrial wastewater |
| Measurement Principle | Sealed reflux digestion coupled with colorimetric detection per GB 11914–1989 |
| Detection Time | 20 min per sample |
| Power Supply | 9 V alkaline battery (up to 40 h continuous operation) |
| Detection Limit | 30 mg/L |
| Range | 0–300 mg/L |
| Accuracy | ±5% |
| Kit Includes | 1 set of colorimetric apparatus, 1 set of sample pretreatment tools, and 1 reagent kit (50 determinations) |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | Ge Crystal Substrates |
| Pricing | Available Upon Request |
| Density | 5.765 g/cm³ |
| Melting Point | 937.4 °C |
| Thermal Conductivity | 64 W/(m·K) |
| Doping Options | Undoped / Sb-doped / In- or Ga-doped |
| Conductivity Type | Intrinsic / n-type / p-type |
| Resistivity | >35 Ω·cm (intrinsic) / 0.05 Ω·cm (Sb-doped) / 0.05–0.1 Ω·cm (In/Ga-doped) |
| Etch Pit Density (EPD) | < 4×10³ cm⁻² for all dopant types |
| Standard Orientations | <111>, <100>, <110> ± 0.5° |
| Standard Polished Wafer Sizes | Ø25.4 mm × 0.3 mm, Ø50.8 mm × 0.5 mm |
| Surface Roughness (Ra) | < 0.5 nm (<110>, non-chemically polished) |
| Packaging | Individual 100-class clean bags in Class 1000 cleanroom environment |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | Ge |
| Pricing | Upon Request |
| Crystal Structure | Cubic, a = 5.6754 Å |
| Growth Method | Czochralski (CZ) |
| Density | 5.765 g/cm³ |
| Melting Point | 937.4 °C |
| Thermal Conductivity | 64 W/(m·K) |
| Doping Types | Undoped / Sb-doped (n-type) / Ga-doped (p-type) |
| Resistivity Range | >35 Ω·cm (undoped), 0.05 Ω·cm (Sb), 0.05–0.1 Ω·cm (Ga) |
| Etch Pit Density (EPD) | < 4 × 10³ cm⁻² |
| Orientations Available | <100>, <110>, <111> ± 0.5° |
| Standard Dimensions | Ø25.4 mm × 0.5 mm, Ø50.8 mm × 0.5 mm, Ø101.6 mm × 0.5 mm |
| Surface Finish | As-cut or mechanically polished (<110>: Ra < 5 Å, non-chemical polish) |
| Packaging | Class 1000 cleanroom + Class 100 clean bag or individual wafer cassette |
| Brand | LABORAT |
|---|---|
| Model | LYG-1020 |
| Origin | Hebei, China |
| Instrument Type | High-Temperature GPC System |
| UV Detector Wavelength Range | 190–700 nm |
| Flow Rate (Standard) | 0.01–50.00 mL/min |
| Flow Rate (Optional High-Precision) | 0.001–10.000 mL/min |
| Auto-Sampler Volume (Standard) | 10 mL loop |
| Column Dimensions (Standard) | 25 × 400 mm |
| Fraction Collector | 5-position valve-based system (customizable) |
| Detection Light Source | Deuterium/Tungsten dual-lamp assembly |
| Software | Integrated industrial PC with audit-trail-enabled chromatography control software |
| Brand | Chemlab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GenesisRaman |
| Price Range | USD 630,000 – 775,000 |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Resolution | ≤2 cm⁻¹ |
| Spatial Resolution | Lateral 1 µm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | ≤±0.2 cm⁻¹ |
| Brand | Genewish |
|---|---|
| Origin | Zhejiang, China |
| Model | Gene TOF 3100 |
| Mass Analyzer Type | Time-of-Flight (TOF) |
| Application Domain | In Vitro Diagnostic (IVD) Devices & Clinical Molecular Testing |
| Regulatory Classification | Domestic IVD Instrument (China NMPA-compliant design basis) |
| Configuration | Integrated PCR-MS workflow platform with automated sample purification and matrix-assisted laser desorption/ionization (MALDI) source |
| Brand | Gentec-EO |
|---|---|
| Origin | Canada |
| Product Type | Laser Beam Diagnostic System |
| Model | BeamWatch Active |
| Wavelength Range | 190 nm – 11 µm |
| Measurement Principle | Non-contact, real-time camera-based beam profiling with ISO 11146-compliant M² calculation |
| Compliance | ISO 11146-1:2005, ISO 11146-2:2005, ANSI Z136.1 |
| Software | BeamWatch Studio v4.x (FDA 21 CFR Part 11 compliant audit trail, GLP/GMP-ready export) |
| Detector Type | High-dynamic-range CMOS sensor array with motorized neutral density filter wheel |
| Spatial Resolution | ≤ 5 µm (system-limited) |
| Frame Rate | Up to 60 Hz at full resolution |
| Data Output | ASCII, CSV, HDF5, TIFF, PNG |
| Interface | GigE Vision, USB 3.2 Gen 1 |
| Brand | Geonics |
|---|---|
| Origin | Canada |
| Model | EM38-MK2 |
| Conductivity Range | 0–1000 mS/m (4-digit display) |
| Accuracy | ±0.1% of full scale |
| Coil Separation | 1.0 m and 0.5 m (dual configuration) |
| Operating Frequency | 14.5 kHz |
| Transmitter | Independent dipole source |
| Receiver | Dual independent dipole coil pair |
| Depth of Investigation | Up to 1.5 m |
| Weight | 5.4 kg |
| Measurement Principle | Frequency-domain electromagnetic induction (EMI) |
| Brand | Gerber |
|---|---|
| Origin | Germany |
| Model | SoluStar 7640 |
| Standard Compliance | IDF 129, ISO 8156 |
| Rotational Speed Range | 1,000–4,000 rpm (adjustable in 10 rpm increments) |
| Fixed setting | 3,600 rpm |
| Stirring Duration | 1–599 s (adjustable) |
| Default setting | 90 s |
| Safety Interlock | Magnetic door switch with transparent safety cover |
| Vessel Handling | Motorized vertical lift and height adjustment for 500 mL borosilicate glass stirring cup |
| Impeller | 16-blade stainless steel, clockwise rotation, blades oriented with flat side downward and upward tilt from right to left |
| Dimensions (W × D × H) | 16.5 × 20.5 × 44.5 cm |
| Weight | 5 kg |
| Power Supply | 220 V, 50 Hz |
| Max. Power Consumption | 43 W |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Instrument Type | Dumas Combustion Method |
| Automation Level | Fully Automated Nitrogen Determinator |
| Nitrogen Range | 0.003 mg – 50 mg N |
| Sample Weight | 0.5 mg – 1 g |
| Digestion/Combustion Time | 3–5 min per sample |
| Repeatability | < 0.5% RSD |
| Recovery Rate | > 99.5% |
| Power Consumption | 2000 W |
| Dimensions (L×W×H) | 370 mm × 800 mm × 500 mm |
| Carrier Gas Options | Helium (high sensitivity) or Argon (cost-optimized) |
| Sample Forms | Solid, liquid, paste |
| Optional Autosampler | 64-, 100-, or 144-position pneumatic autosampler |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Model | KI 12/24 / KI 9/16 |
| Max. Heating Temperature | 650 °C / 600 °C |
| Heating Block Capacity | 4 × 500–750 mL flasks / 6 × 50–250 mL flasks |
| Voltage | 230 V AC |
| Frequency | 50–60 Hz |
| Power | 2320 W / 1800 W |
| Dimensions (W×D×H) | 650 × 380 × 950 mm |
| Weight | 35 kg / 25 kg |
| Compliance | Designed for ASTM D1142, ISO 5983-1, AOAC 984.13, and USP <467> residual solvent workflows |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Model | N-Realyzer |
| Principle | Dumas Combustion Method |
| Automation Level | Fully Automated |
| Nitrogen Range | 0.003–50 mg N |
| Repeatability | RSD < 0.5% |
| Max Sample Weight | 1 g |
| Recovery Rate | ≥99.5% |
| Power Consumption | 1400 W |
| Dimensions (L×W×H) | 600 × 550 × 722 mm |