Chemical Analysis Instruments
Filter
Showing 3181–3210 of 10726 results
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | XplorAA |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp |
| Resolution | <0.2 nm |
| Sensitivity | >0.8 A for 5 mg/L Cu solution |
| Precision (RSD) | <0.45% |
| Detection Limit | Sub-ppb for most elements with graphite furnace |
| Software Control | Handheld PC-based interface |
| Lamp Positions | 2 fixed hollow cathode lamp slots |
| Upgrade Path | Field-upgradable to graphite furnace and hydride generation systems |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | BFH-200 |
| Price | USD 27,500 (FOB Guangzhou) |
| Spectral Range | 350–7800 cm⁻¹ |
| Spectral Resolution | <1.0 cm⁻¹ |
| Signal-to-Noise Ratio | 40,000:1 (peak-to-peak, 4 cm⁻¹, 1 min scan) |
| Light Source | Ge-coated KBr beam splitter (imported) |
| Interferometer | Non-orthogonal Michelson-type with DSP-controlled electromagnetic drive |
| Detector | DLATGS with anti-humidity coating (imported) |
| Operating Systems | Windows XP through Windows 10 (64-bit compatible) |
| Dimensions | 450 × 350 × 210 mm |
| Weight | 13 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory FTIR Spectrometer |
| Spectral Range | 7800–350 cm⁻¹ |
| Resolution | <1.0 cm⁻¹ |
| Scan Speed | 4 cm⁻¹ |
| Signal-to-Noise Ratio | 15,000:1 (at 4 cm⁻¹, 1 min scan) / 30,000:1 (at 4 cm⁻¹, 5 min scan) |
| Beamsplitter | KBr substrate with Ge coating |
| Detector | Imported high-sensitivity DLaTGS |
| Source | Imported long-life, air-cooled high-intensity IR source |
| Interferometer | Sealed 30°-incidence Michelson interferometer with automatic optical alignment |
| Laser | VCSEL-based He–Ne reference laser |
| A/D Conversion | 24-bit, 500 kHz |
| Communication Interface | USB 2.0 (backward compatible with USB 3.0) |
| Dimensions | 450 × 350 × 235 mm (L×W×H) |
| Weight | 14 kg |
| Operating Temperature | 15–35 °C |
| Power Consumption | <30 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Spectral Resolution | <1.0 cm⁻¹ |
| Scan Speed | 4 cm⁻¹ (optical path difference rate) |
| Signal-to-Noise Ratio | 15,000:1 (at 4 cm⁻¹, 1 min scan) / 30,000:1 (at 4 cm⁻¹, 1 min scan, DLaTGS detector) |
| Beamsplitter | KBr substrate with Ge coating |
| Detector | Imported high-sensitivity deuterated triglycine sulfate (DLaTGS) |
| Source | Imported long-life, air-cooled high-intensity IR source |
| Interferometer | Sealed 30°-incidence Michelson interferometer with integrated auto-alignment optics |
| A/D Conversion | 24-bit, 500 kHz |
| Communication Interface | USB 2.0 (backward compatible with USB 3.0) |
| Dimensions | 450 × 350 × 235 mm (L×W×H) |
| Weight | 14 kg |
| Operating Temperature | 15–35 °C |
| Power Consumption | <30 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | BJ-GC128 |
| Price | USD 22,000 (FOB Guangdong) |
| Touchscreen | 7-inch color capacitive display |
| Control Architecture | Dual-mode—embedded real-time OS + PC-based bidirectional software control |
| EFC/EPC | Electronic Flow Control / Electronic Pressure Control on all inlets and detectors |
| Inlet Zones | 2 independently heated (up to 400 °C), compatible with packed columns (φ3/φ4) and split/splitless capillary inlets |
| Detector Options | FID (MDL ≤ 2.5×10⁻¹² g/s n-hexadecane, dynamic range 10⁷), TCD (sensitivity ≥ 5000 mV·mL/mg n-hexadecane, baseline drift ≤ 0.15 mV/30 min), ECD (⁶³Ni source, MDL ≤ 80 fg/s, γ-HCH ≤ 8×10⁻¹⁴ g/mL, dynamic range 10³), FPD (P: MDL ≤ 2×10⁻¹² g/s, S: ≤ 4×10⁻¹¹ g/s, methyl parathion, P/S dynamic range 10³/10²) |
| Oven Specifications | Internal dimensions 280 × 310 × 160 mm |
| operating range | ambient +4 °C to 420 °C |
| Auxiliary Heaters | 2 additional zones (max 400 °C) |
| External Event Ports | 8 TTL-compatible digital I/O channels for valve sequencing, autosampler triggering, or thermal desorption synchronization |
| Connectivity | RS-232 serial port, LAN (LAM protocol), 20 method storage slots |
| Safety Features | Automatic oven fan & heater shutdown upon column chamber door opening |
| Power Requirements | 220 VAC ±10%, 50/60 Hz, 3000 W max |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Category | Domestic HPLC System |
| Model | GB-LC01 |
| Price Range | USD 1,400 – 4,200 |
| Instrument Type | Laboratory-Scale Analytical & Semi-Preparative HPLC System |
| Primary Application Field | Food Safety & Quality Control |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | GC-9802 |
| Price Range | USD 7,000–14,000 (FOB) |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 400 °C |
| Oven Ramp Rate | 0–40 °C/min |
| Oven Cooling Time | ~6 min (from 450 °C to 50 °C) |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | FID (Hydrogen Flame Ionization Detector), Mt ≤ 1×10⁻¹¹ g/s (n-hexadecane), Baseline Drift ≤ 0.02 mV/h, Noise ≤ 0.02 mV |
| Column | OV-1701 Capillary Column (50 m × 0.32 mm ID × 0.5 μm film thickness), Max Temp 400 °C |
| Injector Type | Split/Splitless Capillary Injector (optional packed column inlet) |
| Oven Dimensions | 240 × 210 × 240 mm (W × D × H) |
| Temperature Resolution | 0.1 °C |
| Temperature Stability | ±0.1% of setpoint |
| Carrier Gases | High-purity N₂ (99.99%, 0.4 MPa, dry), H₂ (99.99%, 0.4 MPa, dry), clean oil-free air (0.4 MPa, dry) |
| Gas Line Interface | Φ3 mm tubing |
| External Dimensions | 500 × 550 × 500 mm (H × W × D) |
| Compliance | QBT 2929, GB/T 10004–2008, YBB 00132002 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GC-9802-A |
| Price Range | USD 14,000–21,000 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Field | Food Industry-Specific Analysis |
| Oven Temperature Range | Up to 400 °C |
| Ramp Rate | 0–40 °C/min |
| Injector Maximum Operating Temperature | 400 °C |
| Detector | FID (Hydrogen Flame Ionization Detector), Optional TCD/ECD/NPD |
| FID Sensitivity | Mt ≤ 1 × 10⁻¹¹ g/s (n-Hexadecane) |
| Baseline Drift | ≤ 0.02 mV/h |
| Noise | ≤ 0.02 mV |
| Column | OV-1701 Capillary Column (50 m × 0.32 mm × 0.5 µm), Max Temp 400 °C |
| Injector Type | Split/Splitless Capillary Injector (Optional Packed Column Injector) |
| Oven Dimensions | 240 × 210 × 240 mm |
| Temperature Resolution | 0.1 °C |
| Temperature Control Accuracy | ±0.1% of setpoint |
| Carrier Gas | High-Purity N₂ (99.99%, 0.4 MPa, dry), H₂ (99.99%, 0.4 MPa, dry), Clean Air (0.4 MPa, oil-free, particle-free) |
| Gas Line Connection | Φ3 mm tubing |
| External Dimensions | 500 × 550 × 500 mm (H × W × D) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic Lab-Scale Gas Chromatograph |
| Model | GC-9802-P |
| Price Range | USD 14,000–21,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental & Medical Device Compliance Testing |
| Detector | Hydrogen Flame Ionization Detector (FID) |
| Detection Limit | ≤3×10⁻¹² g/s (n-Hexadecane) |
| Baseline Noise | ≤2×10⁻¹⁴ A |
| Baseline Drift | ≤1×10⁻¹³ A/30 min |
| Column | EO-Specific Capillary Column (30 m × 0.32 mm × 0.5 µm) |
| Oven Temperature Range | 4 °C above ambient to 450 °C (1 °C increments) |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Gradient Uniformity | ±1% |
| Independent Temperature Zones | 6 |
| Programmable Temperature Ramp Stages | 16 |
| Ramp Rate | 0.1–60 °C/min |
| Maximum Run Time | 6000 min |
| Injection Mode | Split/Splitless with Septum Purge |
| Optional Accessories | 20-Position Headspace Autosampler, Oil-Free Air Generator (3 L/min), H₂ Generator (300 mL/min, 99.999% purity), High-Purity N₂ Cylinder (99.999%) with Regulator |
| Software | Dual-Channel Chinese-Language GC Workstation with Instrument Control, Real-Time Chromatogram Display, Zoom/Scroll Functionality, PDF Report Export, and Manual Trigger Button Support |
| Brand | GBPI |
|---|---|
| Model | GC-9802A |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 40–400 °C |
| Temperature Ramp Rate | 0–40 °C/min |
| Cool-Down Time | ~6 min (450 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | FID (Hydrogen Flame Ionization Detector), Mt ≤ 1×10⁻¹¹ g/s (n-Hexadecane), Baseline Drift ≤ 0.02 mV/h, Noise ≤ 0.02 mV |
| Column | OV-1701 Capillary Column (50 m × 0.32 mm × 0.5 µm), Max Temp 400 °C |
| Column Oven Dimensions | 240 × 210 × 240 mm |
| Temperature Resolution | 0.1 °C |
| Temperature Stability | ±0.1% of setpoint |
| Display | Integrated LCD with real-time temperature and status monitoring |
| Power Supply | 220 VAC, 50 Hz |
| Dimensions (H×W×D) | 500 × 550 × 500 mm |
| Compliance Standards | QB/T 2929, GB/T 10004–2008, YBB 00132002 |
| Brand | GBPI |
|---|---|
| Model | GC-9802B |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-purpose, with optimized configuration for residual solvent quantification |
| Oven Temperature Range | 40–400 °C |
| Temperature Ramp Rate | 0–40 °C/min |
| Cool-down Time | ~6 min (from 450 °C to 50 °C) |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Injector Maximum Temperature | 400 °C |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | FID (Flame Ionization Detector), Mt ≤ 1×10⁻¹¹ g/s (n-hexadecane), Baseline Drift ≤ 0.02 mV/h, Noise ≤ 0.02 mV |
| Column | OV-1701 fused-silica capillary column (50 m × 0.32 mm ID × 0.5 µm film thickness), max. operating temperature 400 °C |
| Data System | Integrated chromatography data workstation with real-time acquisition, baseline correction, peak integration, calibration curve generation, PDF report export, and audit-trail-ready operation log |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Organic Solvent Analysis |
| Oven Temperature Range | 40–400 °C |
| Maximum Ramp Rate | 0–40 °C/min |
| Cooling Rate | 450 °C → 50 °C in ~6 min |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | FID (Hydrogen Flame Ionization Detector), Mt ≤ 1×10⁻¹¹ g/s (n-hexadecane), Baseline Drift ≤ 0.02 mV/h, Noise ≤ 0.02 mV |
| Column | OV-1701 Capillary Column (50 m × 0.32 mm ID × 0.5 µm film thickness), Max Temp: 400 °C |
| Display | Integrated LCD with Real-Time Temperature Monitoring |
| Data System | PC-Based Workstation with Chromatographic Acquisition & Quantitative Analysis Software |
| Compliance | QBT 2929, GB/T 10004–2008, YBB 00132002 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | GC9802-K |
| Price Range | USD 14,000–21,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental & Medical Device Testing |
| Detector | Hydrogen Flame Ionization Detector (FID) |
| Detection Limit | ≤3×10⁻¹² g/s (n-Hexadecane) |
| Baseline Noise | ≤2×10⁻¹⁴ A |
| Baseline Drift | ≤1×10⁻¹³ A/30 min |
| Column | EO-Specific Capillary Column (30 m × 0.32 mm × 0.5 µm) |
| Oven Temperature Range | 4 °C above ambient to 450 °C (1 °C increments) |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Gradient Uniformity | ±1% |
| Independent Temperature Zones | 6 |
| Programmable Temperature Ramping | 16 steps |
| Ramp Rate | 0.1–60 °C/min |
| Maximum Run Time | 6000 min |
| Injection Mode | Split/Splitless with Septum Purge |
| Optional Accessories | Zero-Air Generator (3 L/min, oil-free, dehydrated/deoiled), H₂ Generator (300 mL/min, 99.999% purity), High-Purity N₂ Supply (99.999%, cylinder + regulator), EO Certified Reference Standards |
| Software | Dual-Channel Chinese GUI Workstation with Instrument Control, Real-Time Chromatogram Display, Zoom/Pan Functionality, PDF Report Export, Audit-Trail-Ready Data Logging |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC9802-K1 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Quantitative Analysis of Volatile Organic Compounds |
| Detector | Flame Ionization Detector (FID), Optional Alternative Detectors Available |
| Detection Limit | ≤3×10⁻¹² g/s (n-Hexadecane) |
| Baseline Noise | ≤2×10⁻¹⁴ A |
| Baseline Drift | ≤1×10⁻¹³ A/30 min |
| Column | EO-Specific Capillary Column (30 m × 0.32 mm × 0.5 µm), Optional Alternate Columns Supported |
| Autosampler | 20-Position Headspace Sampler |
| Oven Dimensions | 240 × 210 × 240 mm |
| Temperature Range | 4 °C above ambient to 450 °C (1 °C increments) |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Gradient Uniformity | ±1% |
| Independent Temperature Zones | 6 |
| Programmable Temperature Ramps | Up to 16 steps |
| Ramp Rate | 0.1–60 °C/min |
| Maximum Runtime Setting | 6000 min |
| Optional Accessories | Oil-Free Air Generator (3 L/min, with oil/water removal), Hydrogen Generator (300 mL/min, 99.999% purity), High-Purity Nitrogen Cylinder (99.999%, regulator included, locally sourced) |
| Calibration Standard | Certified Ethylene Oxide Reference Material |
| Data System | Dual-Channel Chinese-Language GC Workstation with Instrument Control, Real-Time Chromatogram Display, Zoom/Pan Functionality, PDF Report Export, and Manual Start Button Integration |
| Injection System | Split/Splitless Capillary Injector with Septum Purge Function |
| Safety Features | Dual-Layer Over-Temperature Protection (Software + Hardware), Advanced Acoustic Damping |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC9802-K2 |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Detector | Flame Ionization Detector (FID), optional alternative detectors |
| Detection Limit | ≤3×10⁻¹² g/s (n-hexadecane) |
| Baseline Noise | ≤2×10⁻¹⁴ A |
| Baseline Drift | ≤1×10⁻¹³ A/30 min |
| Column | EO-specific capillary column (30 m × 0.32 mm × 0.5 µm), optional alternate columns |
| Headspace Sampler | 20-position |
| Oven Dimensions | 240 × 210 × 240 mm |
| Temperature Range | 4 °C above ambient to 450 °C (1 °C increments) |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Gradient Uniformity | ±1% |
| Independent Temperature Zones | 6 |
| Programmable Temperature Ramp Stages | 16 |
| Ramp Rate | 0.1–60 °C/min |
| Maximum Runtime Setting | 6000 min |
| Optional Air Generator | Oil-free, with oil/water removal, 3 L/min |
| Optional H₂ Generator | 300 mL/min, purity ≥99.999% |
| Carrier Gas | High-purity nitrogen (99.999%), supplied via cylinder with regulator (local procurement) |
| Certified EO Standard | Included |
| Data System | Dual-channel Chinese-language chromatography workstation with instrument control |
| Injection System | Split/splitless capillary inlet with septum purge function |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC9802-UO |
| Price Range | USD 7,000 – 14,000 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Primary Application Field | Environmental & Medical Device Residue Testing |
| Detector | Flame Ionization Detector (FID), optional alternative detectors available |
| Detection Limit | ≤3×10⁻¹² g/s (n-hexadecane) |
| Baseline Noise | ≤2×10⁻¹⁴ A |
| Baseline Drift | ≤1×10⁻¹³ A/30 min |
| Column | EO-specific capillary column (30 m × 0.32 mm × 0.5 µm), optional columns supported |
| Headspace Sampler | 20-position automated unit |
| Oven Dimensions | 240 × 210 × 240 mm |
| Temperature Range | 4 °C above ambient to 450 °C (1 °C increments) |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Gradient Uniformity | ±1% |
| Independent Temperature Zones | 6 |
| Programmed Temperature Ramping | Up to 16 steps |
| Ramp Rate | 0.1–60 °C/min |
| Maximum Runtime Setting | 6000 min |
| Optional Accessories | Oil-free air generator (3 L/min, with oil/water removal) |
| Injection System | Split/splitless capillary inlet with septum purge |
| Data System | Dual-channel Chinese-language chromatography workstation with instrument control, real-time chromatogram display, zoom/pan functionality, automated report generation (PDF export), and manual hardware start trigger |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GF-1800 |
| Pricing | Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | L9 |
| Wavelength Range | 190–1100 nm |
| Optical Design | Czerny-Turner Monochromator |
| Focal Length | 200 mm |
| Grating Density | 1600 lines/mm |
| Spectral Bandwidth | 0.5 / 1 / 2 / 4 / 5 nm (standard at 2 nm) |
| Wavelength Accuracy | ±0.3 nm (typical ≤±0.2 nm) |
| Wavelength Repeatability | ≤0.1 nm |
| Stray Light | ≤0.02% T (at 220 nm, NaI |
| Photometric Range | 0.0–200.0% T, –0.301–4.000 A, 0.000–9999 C |
| Photometric Accuracy | ±0.2% T, ±0.0009 A (0–0.5 A), ±0.002 A (0.5–1 A) |
| Photometric Repeatability | ≤0.08% T, ≤0.0004 A (0–0.5 A), ≤0.008 A (0.5–1 A) |
| Baseline Flatness | ±0.0006 A |
| Noise | 0.03% T / 0.00015 A |
| Baseline Drift | 0.0003 A/h (after 2 h warm-up at 250 nm & 500 nm) |
| Light Source | Imported deuterium lamp + tungsten-halogen lamp, auto-switching at 340 nm (adjustable) |
| Detector | Imported photodiode array or silicon photodetector |
| Display | 10.1″ capacitive touch screen, Android 10 OS, 262k-color, 178° viewing angle |
| Data Storage | 8 GB internal memory |
| Connectivity | USB port, Wi-Fi, Bluetooth |
| Software Options | UVWin8 PC software (optional), GLP-compliant data logging and audit trail support |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | W202-1 |
| Application | Multi-purpose WVTR analyzer for films, sheets, and packaging containers |
| Test Range | 0.001–100 g/(m²·24h) |
| Test Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45°C (optional 5–55°C) |
| Temperature Control Accuracy | ±0.1°C |
| Humidity Control Range | 0%RH, 30–95%RH |
| Humidity Control Accuracy | ±1%RH |
| Test Area | 50.24 cm² |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | ≤2 mm |
| Sample Capacity | 2 chambers (independent operation) |
| Carrier Gas | ≥99.999% N₂, pressure ≥0.1 MPa, flow rate 5–100 mL/min |
| Gas Inlet | 1/8″ stainless steel tubing |
| Dimensions | 700 × 585 × 485 mm |
| Weight | 80 kg |
| Power | 750 W, AC 220 V / 50 Hz |
| Compliance | GB/T 21529-2008, YBB 00092003-2015, BS EN ISO 15106-3:2005, ASTM E398-2013, DIN 53122-2 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | W403C |
| Test Range | 0.001–100 g/m²·24h |
| Test Accuracy | 0.001 g/m²·24h |
| Temperature Control Range | 15–45°C (optional up to 60°C) |
| Temperature Control Accuracy | ±0.1°C |
| Humidity Control Range | 0% RH (dry), 30–90% RH, and 100% RH |
| Humidity Control Accuracy | ±1% RH |
| Permeation Area | 50.24 cm² (reducible to 0.785 cm² with optional fixtures) |
| Specimen Diameter | Φ100 mm |
| Specimen Thickness | ≤2 mm |
| Sample Capacity | 2 independent test chambers |
| Carrier Gas | ≥99.999% N₂ (user-supplied) |
| Gas Pressure | ≥0.1 MPa |
| Gas Flow Rate | 5–120 mL/min |
| Gas Inlet | 1/8″ metal tubing |
| Dimensions | 61 × 55 × 40 cm |
| Weight | 80 kg |
| Power | 750 W |
| Supply | AC 220 V, 50 Hz |
| Compliance Standards | GB/T 26253-2010, YBB 00092003-2015, BS EN ISO 15106-2:2005, ASTM F1249-2013, JIS K7129-2008 |
| Brand | GBPI |
|---|---|
| Model | ZF-1800A |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Application Domain | Food Contact Material (FCM) Compliance Testing |
| Standards Compliance | GB 31604.8–2016, GB 31604.1–2015, GB/T 5009.156–2016, GB/T 9740–2008, GB/T 23949–2009, YBB00342002–2015, YBB00102005–2015, YBB00082002–2015 |
| Measurement Range | 0.167–167,000 mg/dm² |
| Resolution | 0.0001 mg/dm² |
| Balance Capacity | 0–200 g |
| Balance Readability | 0.1 mg |
| Water Bath Temp Control | 68.3–100 °C |
| Heating Chamber Temp Control | 68.3–117.9 °C |
| Cooling Chamber Temp Control | <27.5 °C |
| Temperature Accuracy | ±3 °C |
| Sample Throughput | 1–18 independent test positions |
| Gravimetric恒重 Cycle Time | 2.5 h (typical) |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (L×W×H) | 180 × 90 × 120 cm |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 1500 W |
| Brand | GBPI |
|---|---|
| Model | ZF1800-2A |
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Category | Other General Analytical Instruments |
| Measuring Range | 0.2–167,000 mg/dm² |
| Resolution | 0.0001 g/dm² |
| Balance Capacity | 0–200 g |
| Balance Resolution | 0.1 mg |
| Water Bath Temp Control | RT–100 °C |
| Heating Chamber Temp Control | RT–117.9 °C |
| Cooling Chamber Temp Control | 10–35 °C |
| Temperature Uniformity | ±5 °C |
| Sample Capacity | 1–18 independent stations |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (Main Unit) | 178 × 93 × 145 cm (L×W×H) |
| Solvent Recovery System Dimensions | 120 × 88 × 170 cm (L×W×H) |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 5000 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Model | ZF1800-A1 |
| Measuring Range | 0.2–167,000 mg/dm² |
| Resolution | 0.0001 g/dm² |
| Balance Capacity | 0–200 g |
| Balance Resolution | 0.1 mg |
| Water Bath Temp Control | RT–100 °C |
| Heating Chamber Temp Control | RT–117.9 °C |
| Cooling Chamber Temp Control | 10–35 °C |
| Temperature Uniformity | ±5 °C |
| Sample Capacity | 1–18 independent stations |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (Main Unit) | 178 × 93 × 145 cm (L×W×H) |
| Dimensions (Solvent Recovery Unit) | 120 × 88 × 170 cm (L×W×H) |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 5000 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | ZF1800-D |
| Price | Upon Request |
| Measurement Range | 0.2–167,000 mg/dm² |
| Resolution | 0.0001 g/dm² |
| Balance Capacity | 0–200 g |
| Balance Resolution | 0.1 mg |
| Water Bath Temp. Control | RT–100 °C |
| Heating Chamber Temp. Control | RT–117.9 °C |
| Cooling Chamber Temp. Control | 10–35 °C |
| Temperature Accuracy | ±5 °C |
| Sample Capacity | 1–18 independent test positions |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (Main Unit) | 178 × 93 × 145 cm (L×W×H) |
| Solvent Recovery System Dimensions | 120 × 88 × 170 cm (L×W×H) |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 5000 W |
| Brand | GBPI |
|---|---|
| Model | ZF1800-F |
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Category | Other General Analytical Instruments |
| Measurement Range | 0.2–167,000 mg/dm² |
| Resolution | 0.0001 g/dm² |
| Balance Capacity | 0–200 g |
| Balance Resolution | 0.1 mg |
| Water Bath Temp Control | RT–100 °C |
| Heating Chamber Temp Control | RT–117.9 °C |
| Cooling Chamber Temp Control | 10–35 °C |
| Temperature Uniformity | ±5 °C |
| Sample Capacity | 1–18 independent test positions |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (Tester) | 178 × 93 × 145 cm (L×W×H) |
| Dimensions (Solvent Recovery Unit) | 120 × 88 × 170 cm (L×W×H) |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 5000 W |
| Brand | GBPI |
|---|---|
| Model | ZF1800-S |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Category | Other General Analytical Instruments |
| Measurement Range | 0.2–167,000 mg/dm² |
| Resolution | 0.0001 g/dm² |
| Balance Capacity | 0–200 g |
| Balance Resolution | 0.1 mg |
| Water Bath Temp Control | RT–100 °C |
| Heating Chamber Temp Control | RT–117.9 °C |
| Cooling Chamber Temp Control | 10–35 °C |
| Temperature Uniformity | ±5 °C |
| Sample Capacity | 1–18 independent test positions |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (Main Unit) | 178 × 93 × 145 cm (L×W×H) |
| Solvent Recovery System Dimensions | 120 × 88 × 170 cm (L×W×H) |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 5000 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | ZF1800-T |
| Quotation | Upon Request |
| Measurement Range | 0.2–167,000 mg/dm² |
| Resolution | 0.0001 g/dm² |
| Balance Capacity | 0–200 g |
| Balance Resolution | 0.1 mg |
| Water Bath Temp Control | Ambient to 100 °C |
| Heating Chamber Temp Control | Ambient to 117.9 °C |
| Cooling Chamber Temp Control | 10–35 °C |
| Temperature Accuracy | ±5 °C |
| Sample Positions | 1–18 (independent) |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (Main Unit) | 178 × 93 × 145 cm (L×W×H) |
| Solvent Recovery System Dimensions | 120 × 88 × 170 cm (L×W×H) |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 5000 W |
| Brand | GBPI |
|---|---|
| Model | ZF1800A |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Category | General Analytical Instrument for Food Contact Materials Testing |
| Measurement Range | 0.167–167,000 mg/dm² |
| Resolution | 0.0001 mg/dm² |
| Balance Capacity | 0–200 g / Readability: 0.1 mg |
| Water Bath Temp Control | 68.3–100 °C |
| Heating Chamber Temp Control | 68.3–117.9 °C |
| Cooling Chamber Temp Control | <27.5 °C |
| Temp Accuracy | ±3 °C |
| Sample Capacity | 1–18 independent test positions |
| Evaporation Dish Volume | 0–200 mL |
| Dimensions (L×W×H) | 180 × 90 × 120 cm |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 1500 W |
| Brand | GBPI |
|---|---|
| Model | ZF1800B |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Category | Domestic Instrument |
| Price | Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ZF1800B1 |
| Price | Upon Request |
| Measurement Range | 0.2–167,000 mg/dm² |
| Resolution | 0.0001 g/dm² |
| Balance Capacity | 0–200 g |
| Balance Resolution | 0.1 mg |
| Water Bath Temp Control | RT–100 °C |
| Heating Chamber Temp Control | RT–117.9 °C |
| Cooling Chamber Temp Control | 10–35 °C |
| Temperature Uniformity | ±5 °C |
| Sample Capacity | 1–18 independent stations |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (Main Unit) | 178 × 93 × 145 cm (L×W×H) |
| Solvent Recovery System Dimensions | 120 × 88 × 170 cm (L×W×H) |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 5000 W |