| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | DFS High-Resolution GC/MS |
| Instrument Type | Magnetic Sector Mass Spectrometer |
| GC Configuration | Dual-Column, Dual-Trace 1310 GC Integration |
| Automation | TriPlus RSH Autosampler |
| Ion Source | Removable, Vacuum-Lock Ion Box |
| Analyzer Architecture | Double-Focusing Magnetic Sector with Ring-shaped Electrostatic Analyzer (ESA) |
| Calibration | Field-Based Mass Calibration Independent of Scan Speed, Ion Polarity, and Ionization Mode |
| Detection | Dual-Stage Electron Multiplier with Pneumatic Valve Vacuum Lock |
| Regulatory Compliance | Designed for EPA Method 1613/8270, EU Directive 2006/122/EC, WHO IPCS Dioxin Guidelines, USP <1225>, FDA 21 CFR Part 11 Audit Trail Support |
| Brand | Thermo Fisher |
|---|---|
| Model | DFS |
| Type | Double-Focusing Magnetic Sector GC-MS |
| Detector | Dual-Channel Electron Multiplier with Convertor Electrode |
| Resolution | Up to 100,000 (10% Valley) |
| Mass Range | 10–2000 m/z |
| Ion Source | Removable, Modular EI/CI Source |
| Vacuum System | Pneumatic Valve Lock for Ion Box Exchange Without Venting |
| GC Compatibility | Dual Trace 1310 GCs on Single Ion Source |
| Automation | TriPlus RSH Autosampler with Dual-Column Sequential Injection |
| Calibration | Field-Based, Mode-Independent Mass Calibration |
| Software | Thermo Xcalibur with DFS-Specific Acquisition & Quantitation Modules |
| Compliance | Designed for EPA Method 1613/8270, EU 2017/625, ISO 18073, and GLP/GMP environments requiring 21 CFR Part 11 audit trails |
| Brand | Thermo Fisher |
|---|---|
| Origin | Mexico |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Instrument |
| Model | Aquion |
| Pump Pressure Rating | 5000 psi |
| Flow Rate Range | 0.00–5.00 mL/min |
| Eluent Flow Rate | 0.00–5.00 mL/min |
| Maximum Operating Pressure | 5000 psi |
| Column Oven Temperature Range | 30–60 °C |
| Temperature Reproducibility | ±0.5 °C |
| Eluent Concentration Range | 0.1–100 mM (dependent on eluent chemistry) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Mexico |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | Aquion RFIC |
| Instrument Type | Laboratory |
| Maximum Pump Pressure | 5000 psi |
| Flow Rate Range | 0.00–5.00 mL/min |
| Eluent Flow Rate Range | 0.00–5.00 mL/min |
| Maximum Operating Pressure | 5000 psi |
| Operating Temperature Range | Ambient +5°C to 60°C |
| Temperature Reproducibility | ±0.05°C |
| Eluent Concentration Range | 0.1–100 mM |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | AS-AP |
| Instrument Category | Multifunctional Autosampler |
| Sample Capacity | Up to 1152 positions (microtiter plate) / 81 vials (10 mL) |
| Injection Cycle Time | <30 s for 5 µL injection |
| Precision | RSD <0.3% |
| Fluidic Path | Full PEEK™ construction |
| Needle Design | Moving-needle architecture |
| Temperature Control | 4–60 °C sample tray cooling |
| Integrated Pre-injection Analysis | Conductivity & pH measurement |
| Automation Capabilities | Automated internal standard addition, on-line dilution, pre-column derivatization, matrix removal, analyte preconcentration, fraction collection, re-injection, and sample ejection |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | AS-DV |
| Instrument Category | Multifunctional Autosampler |
| Fluidic Path Material | PEEK™ |
| Compatible Systems | All Dionex ICS Ion Chromatography Systems |
| Sample Vial Capacity | 5.0 mL and 0.5 mL polymer vials |
| Valve Options | Optional 6-port or 10-port switching valves |
| Software Control | Thermo Scientific Chromeleon CDS (v7.3 or later) |
| Audit Trail & Electronic Signatures | Compliant with 21 CFR Part 11 |
| Dual-IC System Operation | Supported |
| Sample Overlap Injection | Enabled |
| Filtration Option | Available with filter cap accessory |
| Detection Limit Enhancement | Via automated on-line preconcentration and matrix elimination |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | AS-HV |
| Instrument Category | Multifunctional Autosampler |
| Sample Capacity | Up to 250 mL |
| Syringe/Pump Options | Syringe, Peristaltic, or Piston Pump |
| Rack Compatibility | 21-position (50 mL vials, 30 mm O.D.), 24-position (26 mL vials, 24 mm O.D.), 40-position (15 mL vials, 20 mm O.D.), 60-position (10 mL vials, 16 mm O.D.), or 21-position (60/40 mL ASE™ Collection Vials) |
| Fluid Path Material | All-PEEK™ |
| Loading Mode | Programmable “push” or “pull” |
| Arm Motion | High-speed, high-precision robotic positioning |
| Footprint | Compact benchtop design |
| Optional Integration | Dionex AutoPrep™ system, RFIC™-ESP platform, trace analysis cover |
| Brand | Thermo Fisher |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC-manufactured) |
| Model | Dionex Easion Ion Chromatography System |
| Instrument Type | Laboratory Benchtop IC System |
| Application Scope | General-Purpose Anion/Cation Analysis |
| Pump Pressure Range | 0–35 MPa |
| Flow Rate Range | 0.00–5.00 mL/min (single-pump-head design) |
| Maximum Operating Pressure | 10 MPa |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | ICS-1100 |
| Instrument Type | Laboratory Benchtop System |
| Maximum Pump Pressure | 6000 psi |
| Operating Pressure Range | Up to 5000 psi |
| Column Oven Temperature Range | 4–40 °C |
| Eluent Concentration Range | 0–100 mM (KOH), adjustable per eluent chemistry |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ICS-1600 |
| Instrument Type | Laboratory Benchtop System |
| Maximum Pump Pressure | 6000 psi |
| Operating Pressure Range | Up to 5000 psi |
| Column Oven Temperature Range | 4–40 °C |
| Eluent Concentration Range | 0–100 mM KOH (varies with eluent chemistry) |
| Eluent Generation Compatibility | RFC-30 Electrolytic Eluent Generator |
| Suppressor Type | AutoSuppression™ Electrolytic Micro-Membrane Suppressor |
| Software Platform | Chromeleon™ 7.3 or later |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Instrument |
| Model | ICS-4000 |
| Pump Pressure Rating | 6000 psi |
| Flow Rate Range | 0.001–0.100 mL/min |
| Eluent Flow Rate | 0.001–0.100 mL/min |
| Maximum Operating Pressure | 6000 psi |
| Operating Temperature Range | 10°C–40°C |
| Temperature Reproducibility | ±0.2°C |
| Eluent Concentration Range | 0–100 mM (KOH), dependent on eluent chemistry |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | ICS-4000 CD |
| Instrument Category | Laboratory Benchtop Ion Chromatograph Detector |
| Detection Principle | Suppressed/Unsuppressed Conductivity Detection |
| Dynamic Range | 0–15,000 µS/cm |
| Cell Volume | 0.02 µL (Capillary Mode) |
| Temperature Control | Independent, Microprocessor-Regulated Detector Thermostat |
| Interface | Plug-and-Play Auto-Recognition via Chromeleon™ CDS |
| Mounting | Tool-Free Snap-In Mechanism |
| Compatible Configurations | Series or Parallel Dual-Detector Setup |
| Flow Path Options | Capillary, Analytical (Standard-Bore and Microbore) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ICS-5000+ CD |
| Application Environment | Laboratory-Based Ion Chromatography System |
| Configuration Options | Capillary and Analytical (Standard-Bore & Microbore) Flow Paths |
| Detector Architecture | Digital Signal Processing (DSP)-Enabled, Thermally Stabilized Conductivity Detection Module |
| Dynamic Range | 0–15,000 µS/cm |
| Cell Volume (Capillary Mode) | 0.02 µL |
| Installation Interface | Tool-Free Snap-In Mounting with Auto-Detection via Chromeleon™ CDS |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ICS-5000+ ED |
| Application | Laboratory-Based Ion Chromatography |
| Detection Principle | Pulsed Amperometric Detection (PAD), DC Amperometry, Integrated Amperometry, and Cyclic Voltammetry |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ICS-600 |
| Instrument Type | Laboratory |
| Pump Pressure Rating | 5000 psi |
| Flow Rate Range | 0.00–5.00 mL/min |
| Eluent Flow Rate | 0.00–5.00 mL/min |
| Maximum Operating Pressure | 5000 psi |
| Operating Temperature Range | Ambient +5°C to 60°C |
| Temperature Reproducibility | ±0.1°C |
| Eluent Concentration Range | 0–100 mM (KOH), dependent on eluent chemistry |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ICS-6000 |
| Pump Pressure Rating | 6000 psi |
| Flow Rate Range | 0.001–22.4 mL/min |
| Eluent Flow Rate Range | 0.001–22.4 mL/min |
| Maximum Operating Pressure | 10 MPa |
| Operating Temperature Range | 10°C–70°C |
| Temperature Reproducibility | ±0.05°C |
| Eluent Concentration Range | 0.1–200 mM |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ICS-900 Starter Line IC System |
| Pump Pressure Rating | 6000 psi |
| Maximum Operating Pressure | 5000 psi |
| Operating Temperature Range | 4–40 °C |
| Eluent Concentration Range | 0–100 mM (KOH), dependent on eluent chemistry |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Instrument |
| Model | ICS-VWD |
| Wavelength Range | 190–900 nm |
| Data Acquisition Rate | Up to 100 Hz |
| Light Sources | Deuterium Lamp + Tungsten Lamp |
| Software Control | Thermo Scientific Dionex Chromeleon Chromatography Data System (CDS) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | Dionex Inuvion |
| Instrument Type | Laboratory |
| Application Scope | General-purpose |
| Pump Pressure Rating | 5000 psi |
| Flow Rate Range | 0–5 mL/min |
| Maximum Operating Pressure | 5000 psi |
| Operating Temperature Range | 10–60 °C (±0.5 °C) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | DXR3xi |
| Instrument Category | Confocal Micro-Raman Spectrometer |
| Spectral Range | 50–9000 cm⁻¹ |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution | 350 nm |
| Excitation Wavelength | 455 nm (optional lasers available) |
| Spectral Reproducibility | ±0.1 cm⁻¹ |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Evolution Pro |
| Instrument Configuration | Double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | Selectable 0.5, 1.0, 1.5, 2.0, or 4.0 nm |
| Wavelength Accuracy | ±0.20 nm at 546.07 nm (Hg emission line) |
| Wavelength Repeatability | Standard deviation <0.05 nm over 10 consecutive measurements |
| Stray Light | ≤0.4% T at 198 nm (KCl), ≤0.032% T at 220 nm (NaI), <0.01% T at 340 nm (NaNO₂) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Exactive™ GC Orbitrap™ GC-MS |
| Instrument Type | Orbitrap Mass Spectrometer |
| Chromatography Type | Gas Chromatography |
| Mass Range | Not Specified |
| Resolution | 60,000 (FWHM) at m/z 200 |
| Sensitivity | <6 fg OFN (Octafluoronaphthalene) |
| Scan Speed | Not Specified |
| Ionization Modes | Electron Ionization (EI) / Chemical Ionization (CI) |
| Ion Source | Thermo Scientific™ ExtractaBrite™ with Vacuum Lock |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Model | FlashSmart CHN |
| Measurement Elements | C, H, N (expandable to CHNSO, CHNS, NCS, NC, N, S, O) |
| Analysis Time | 5–10 min (sample-weight and matrix dependent) |
| Detection Limit | <40 ppm |
| Accuracy | ≤0.05% |
| Sample Volume | up to 500 µL |
| Detectors | Thermal Conductivity Detector (TCD), Flame Photometric Detector (FPD), Infrared Detector (IR), Isotope Ratio Mass Spectrometer (IRMS) interface |
| Combustion Temperature | up to 1800 °C |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Model | FlashSmart CN/CNS |
| Detection Principle | Dynamic Flash Combustion coupled with Gas Chromatographic Separation |
| Detector Options | TCD (standard), optional chemiluminescence or IR detectors |
| Combustion Temperature | up to 1800 °C (Sn capsule mode) |
| Warranty | 15 years on combustion furnace and TCD detector |
| Automation | Fully software-controlled oxygen injection, sample weighing, and combustion timing |
| Compliance | Designed for GLP/GMP environments |
| Carrier Gas Options | Helium (standard), Argon (cost-optimized alternative) |
| Modular Configurations | Upgradable to CHNS, CHN, NC, NCS, N, S, O modes |
| Sample Types | Solids (soils, sediments, biomass, coal, polymers), liquids (oils, extracts, aqueous solutions), and heterogeneous matrices |
| Throughput | Up to 120 samples/day with dual autosamplers (solid + liquid) |
| Software Platform | EagerQ™ v3.2 with method templates, calibration wizards, and raw data export (CSV, XML, PDF) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Instrument Type | Dumas Combustion Method |
| Automation Level | Fully Automated Elemental Analyzer |
| Nitrogen Measurement Range | 0.001–500 mg N |
| Reproducibility | <0.3% RSD |
| Sample Mass Requirement | ≥1 g |
| Recovery Rate | 99.5–100% |
| Digestion/Combustion Time | 3–4 min per sample |
| Linear Range | 0.001–500 mg N |
| Power Consumption | 1400 W |
| Dimensions (L×W×H) | 620 × 580 × 500 mm |
| Sample Capacity | Up to 125 positions (with optional 4-position carousel) |
| Compliance | ASTM D5142, AOAC 992.15, ISO 14891, EN ISO 16634-1/-2, USP <28>, FDA 21 CFR Part 11 ready (via EagerSmart software audit trail) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Instrument Type | Dumas Combustion Method |
| Automation Level | Fully Automated Nitrogen Determinator |
| Nitrogen Range | 0.001–500 mg N |
| Reproducibility | <0.3% RSD |
| Sample Weight | ≥1 g |
| Recovery Rate | 99.5–100% |
| Digestion/Combustion Time | 3–4 min per sample |
| Power Consumption | 1400 W |
| Dimensions (L×W×H) | 620 × 580 × 500 mm |
| Linearity Range | 0.001–500 mg N |
| Sample Capacity | Up to 125 positions (with optional multi-rack configuration) |
| Gas Flow Control | Electronic Flow Control (EFC) |
| Software Platform | EagerSmart™ Operating Software |
| Compliance | ASTM D515, ISO 13878, AOAC 992.15, USP <467>, EN ISO 13878, and GLP/GMP-ready audit trail support |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Model | FlashSmart |
| Element Range | CHNSO, CHNS, CHN, NCS, NC, N, S, O (configurable modes) |
| Analysis Time | 5–10 min (sample-weight- and matrix-dependent) |
| Detection Limit | <40 ppm (S: down to 4 ppm with FPD/IR |
| Measurement Precision | ≤0.05% RSD |
| Sample Introduction | Up to 500 µL liquid or 1 g solid |
| Detector Options | Thermal Conductivity Detector (TCD), Flame Photometric Detector / Infrared Detector (FPD/IR), Isotope Ratio Mass Spectrometer (IRMS) interface, Chlorine (Cl) measurement module |
| Combustion Temperature | Up to 1800 °C |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | FoodDefender RM |
| Instrument Category | Handheld Raman Spectrometer |
| Spectral Range | 250 cm⁻¹ to 2875 cm⁻¹ |
| Spectral Resolution | 7–10.5 cm⁻¹ (FWHM, full range) |
| Spatial Resolution | 7–10.5 cm⁻¹ (Raman), 4 cm⁻¹ (IR-equivalent reference) |
| Minimum Wavenumber | 250 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.5 cm⁻¹ shift across three consecutive scans on homogeneous sample |
| Weight | 800 g |
| Dimensions | 19.3 × 10.7 × 4.4 cm |
| Laser Output Power | Adjustable (75 / 125 / 250 mW) |
| Numerical Aperture | NA = 0.23 |
| Working Distance | 17 mm |
| Spot Size | 0.14–1.8 mm |
| Integration Time | Manual or auto mode (minimum 5 ms) |
| Delay Time | Configurable (0–120 s) |
| Power Supply | Rechargeable Li-ion battery or two 123A alkaline cells |
| Operating Temperature | −20 °C to +40 °C |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | G2397-60720 |
| Type | OEM Replacement Component for Gas Chromatography–Electron Capture Detection Systems |
| Compliance | Designed for use with Thermo Scientific™ TRACE™ and ISQ™ GC-MS platforms |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Imported |
| Model | GENESYS™ 140 |
| Optical Design | Double-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 325–1100 nm |
| Wavelength Scanning | Automatic |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <0.05% T at 340 nm and 400 nm |