| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SP-20Start |
| Instrument Type | Thin-Layer Chromatography (TLC) Sample Spotter |
| Spotting Mode | Non-contact |
| Spot Shape | Circular or Linear Band |
| Maximum Spotting Length | 150 mm |
| Plate Size Compatibility | 200 mm × 200 mm |
| Spotting Volume Range | 1–20 µL (customizable up to 100 µL) |
| Spotting Accuracy | < 0.2% RSD |
| Spotting Reproducibility | < 0.5% RSD |
| Minimum Band Width | 0.2 mm |
| Syringe Options | 10, 25 (standard), 50, and 100 µL |
| X-Axis Resolution | 200 steps/mm |
| Y-Axis Resolution | 400 steps/mm |
| Syringe Drive Resolution | 3200 steps/mm (6400 steps/µL for 25 µL syringe) |
| Operating Pressure | 0.4 MPa (N₂ or compressed air) |
| Gas Flow Rate | 2–3 L/min |
| Heating Stage Temperature Range | Ambient to 60 °C (±1 °C stability) |
| Power Supply | 220 V, 50 Hz, 90 W |
| Control Interface | Integrated 7-inch capacitive touchscreen |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SP-30E |
| Instrument Category | TLC Sample Spotter |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmission Absorption, Transmission Fluorescence |
| Wavelength Range | 190–800 nm |
| Light Sources | Xenon Lamp, Tungsten-Halogen Lamp, High-Pressure Mercury Lamp |
| Monochromator | Holographic Grating (1200 lines/mm) with Nitrogen Purge Capability |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | <1 nm |
| Wavelength Repeatability | <0.2 nm |
| Minimum Resolution | 25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White Light |
| Sample Stage Capacity | Up to 200 mm × 200 mm TLC Plates |
| Maximum Scanning Speed | 100 mm/s |
| Spotting Volume Range | 10 nL – 2 mL |
| Spotting Precision | ±1.25 nL (with 25 µL syringe) |
| Syringe Options | 10 µL, 25 µL (standard), 50 µL, 100 µL |
| X/Y/Axial Drive Resolution | 200 steps/mm (X), 400 steps/mm (Y), 3200 steps/mm (syringe) |
| Heating Stage Range | Ambient to 60 °C (±1 °C) |
| Heated Nozzle | 30–80 °C |
| Auto-sampler Capacity | 96 × 2 mL vials |
| Gas Supply | 0.4 MPa, N₂ or compressed air |
| Flow Rate | 2–3 L/min |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SP-II |
| Instrument Category | TLC Sample Spotter |
| Sample Application Modes | Circular Spot & Linear Band |
| Spotting Range | 0–200 mm |
| Spotting Temperature Range | Ambient to 100 °C |
| Heating Platform Temperature Range | Ambient to 200 °C |
| Heating System | CNC Digital Display Heated Stage with Uniform Heat Distribution Plate |
| Drive Mechanism | High-Reliability Shanghai Brand Stepper Motor Assembly |
| Spotting Precision | Contact-Based, Non-Sticking Needle Interface |
| Compliance | Designed for GLP-aligned laboratory workflows and compatible with ISO 17025 traceability requirements |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | TBOX-I |
| Instrument Category | TLC Auxiliary Equipment |
| Sample Plate Size | 200 × 200 mm |
| Airflow Capacity | 4000 L/min |
| Construction Materials | Stainless Steel Enclosure, Corrosion-Resistant Gas Conduit, Integrated Spray Stand |
| Noise Level | Low-Noise Operation |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory safety workflows |
| Software Interface | None (Standalone Mechanical System) |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TD-I |
| Plate Width Compatibility | 50 mm, 100 mm, 200 mm |
| Adjustable Coating Thickness Range | 0–2.5 mm |
| Plate Size Support | Standard 200 mm × 200 mm (customizable to 300 mm × 200 mm) |
| Construction | CNC-machined stainless steel and anodized aluminum components |
| Includes | Multi-size carrier tray, adjustable slurry reservoir, integrated mini slurry homogenizer, precision thickness gauge |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Model | TD-II |
| Plate Thickness Range | 0–3 mm (continuously adjustable) |
| Plate Width Options | 100 mm & 200 mm |
| Coating Cycle Time | ≤10 seconds per plate |
| Single-Batch Capacity | 4×(200×200 mm), 8×(200×100 mm), or 16×(100×100 mm) plates |
| Power Supply | 220 V, 50 Hz, 10 W (main unit only) |
| Construction | Stainless steel frame and wetted components |
| Compliance | Designed to meet Chinese Pharmacopoeia 2015 Edition requirements for quantitative TLC |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | TH-II |
| Instrument Type | TLC Ancillary Equipment |
| Detection Modes | Reflectance Absorption, Reflectance Fluorescence, Transmittance Absorption, Transmittance Fluorescence |
| Wavelength Range | 190–800 nm |
| Light Sources | Xenon Lamp, Tungsten-Halogen Lamp, High-Pressure Mercury Lamp |
| Monochromator | Holographic Grating (1200 lines/mm), Nitrogen Purge Capable |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | < 1 nm |
| Wavelength Repeatability | < 0.2 nm |
| Minimum Spatial Resolution | 25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White Light |
| Sample Stage Capacity | 200 mm × 200 mm TLC Plate |
| Maximum Scan Speed | 100 mm/s |
| Temperature Range | 0–200 °C |
| Temperature Accuracy | ≤ ±1 °C |
| Heating Platform Dimensions | 300 mm × 250 mm |
| Power Supply | 220 V AC, 600 W |
| Heating Element | Cast-Aluminum Block with Uniform-Heat Plate |
| Construction | Stainless Steel Sample Tray, Digital PID Temperature Controller |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Forced-Flow TLC Development System |
| Model | TK-10 |
| Wavelength Options | 254 nm or 365 nm |
| Maximum Plate Size | 200 mm × 200 mm |
| Development Distance Range | 10–200 mm |
| Development Distance Accuracy | ≤1 mm |
| Interface | USB |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Automated TLC Development System |
| Model | TK-20E |
| Operation Mode | Fully Automatic |
| Maximum Plate Size | 200 mm × 200 mm |
| Development Distance Range | 40–180 mm |
| Development Distance Accuracy | ≤1 mm |
| Humidity Control Range | 10–90% RH (65–90% RH requires optional humidification module) |
| Gas Flow Rate | 0–16 L/min |
| Solvent Consumption | ≤20 mL per run |
| Interface | RS232 / USB |
| Temperature & Humidity Monitoring | Real-time onboard sensors |
| Compliance Support | GLP/GMP workflows and FDA 21 CFR Part 11 audit trail capability via software |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (PRC-Made) |
| Model | TK-II |
| Price Range | USD 1,400 – 4,200 (FOB Shanghai) |
| Instrument Type | TLC Ancillary Equipment Suite |
| UV Wavelengths | 254 nm & 365 nm |
| Max Plate Size Supported | 200 × 200 mm |
| Min Plate Size Supported | 25 × 75 mm (development), 50 × 50 mm (storage) |
| Imaging Platform | Integrated dark chamber with dual-band UV illumination |
| Resolution | Single-band spectral isolation via fixed-wavelength UV lamps |
| Scan Capability | Visual observation and photographic documentation only (no motorized scanning or densitometry) |
| Plate Handling | Manual positioning |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TM-200 |
| Instrument Type | TLC–MS Interface |
| Measurement Mode | Transmission Absorption |
| Wavelength Range | 190–800 nm |
| Light Source | Laser |
| Laser Power | 5 mW |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | < 1 nm |
| Wavelength Repeatability | < 0.2 nm |
| Minimum Spatial Resolution | 25 µm |
| Imaging Wavelength | 254 nm |
| Maximum TLC Plate Size | 200 × 200 mm |
| Solvent Flow Rate | 0.05–0.3 mL/min |
| Pneumatic Source | N₂ or Compressed Air |
| Sealing Force | Up to 500 N |
| Extraction Probe Options | Ø4 mm, Ø5 mm (circular), 4 × 2 mm (elliptical) |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TS-I |
| Price Range | USD 140–700 |
| Instrument Category | TLC Auxiliary Equipment |
| Spray Nozzle Diameter | 0.2 mm |
| Operating Pressure Range | 10–30 PSI |
| Maximum Spray Distance | 50 cm |
| Construction Material | Full Stainless Steel |
| Compressor Type | Imported Compact Oil-Free Air Compressor |
| Noise Level | Low-Noise Operation |
| Nozzle Replaceability | Quick-Swap Design |
| Waste Minimization | Optimized Reagent Delivery System |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | TS-II |
| Instrument Category | TLC Auxiliary Equipment |
| Detection Modes | Reflectance Absorption, Reflectance Fluorescence, Transmission Absorption, Transmission Fluorescence |
| Wavelength Range | 190–800 nm |
| Light Sources | Xenon Lamp, Tungsten-Halogen Lamp, High-Pressure Mercury Lamp |
| Monochromator | Holographic Grating (1200 lines/mm) with Nitrogen Purge Capability |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | < 1 nm |
| Wavelength Repeatability | < 0.2 nm |
| Minimum Spatial Resolution | 25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White Light |
| Sample Stage Capacity | Accommodates TLC Plates up to 200 mm × 200 mm |
| Maximum Scan Speed | 100 mm/s |
| Nozzle Orifice Diameters | 0.2 mm (Nozzle B), 0.3 mm (Nozzle A) |
| Spray Distance Range | 0–500 mm |
| Operating Pressure | 30 psi |
| Aerosol Particle Size Distribution | 0.1–3 µm |
| Included Components | Dedicated Low-Noise Micro Air Pump, PTFE-Coated Nozzle A, Ultrafine Stainless-Steel Nozzle B |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | TY-10 |
| Instrument Category | TLC Auxiliary Equipment |
| Maximum Plate Size | 200 × 100 mm (standard), 200 × 200 mm (customizable) |
| Immersion Speed | 0–10 mm/s (adjustable) |
| Configuration Includes | Reagent Reservoir Tank, Main Derivatization Unit, TLC Plate Holder Assembly, Dedicated Control Software |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | TY-I |
| Instrument Category | TLC Imaging & Derivatization System |
| Light Sources | UV 254 nm, UV 365 nm, Visible White Light |
| Imaging Resolution | ≥4 MP |
| Maximum Sample Platform Size | 200 × 200 mm |
| Derivatization Modes | Immersion and Spray |
| Immersion Chamber Options | 200 mm and 100 mm formats |
| Compliance | Designed for GLP-compliant manual derivatization workflows in analytical laboratories |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | UV+2000 |
| Instrument Type | Fluorescence Detector (FD) Compatible Derivatization Device |
| Wavelength Range | 195–600 nm |
| Measurement Mode | Dual-Beam |
| Light Source | Xenon Lamp |
| Maximum Flow Rate | 2 mL/min (customizable) |
| Brand | KEZHE / KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | SP-III |
| Instrument Category | Thin-Layer Sample Applicator |
| Operation Mode | Automatic |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmission Absorption, Transmission Fluorescence |
| Wavelength Range | 190–800 nm |
| Light Sources | Xenon Lamp, Tungsten-Halogen Lamp, High-Pressure Mercury Lamp |
| Monochromator | Holographic Grating (1200 lines/mm), Nitrogen Purge Compatible |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | < 1 nm |
| Wavelength Repeatability | < 0.2 nm |
| Minimum Spatial Resolution | 25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White Light |
| Sample Stage Capacity | Up to 200 mm × 200 mm TLC Plates |
| Scanning Speed | Up to 100 mm/s |
| Spotting Length | 0–200 mm |
| Spotting Width | 0.7–3 mm (Standard: 1–2 mm) |
| Spotting Temperature Range | Ambient to 100 °C |
| Heating Platform Temperature Range | Ambient to 200 °C |
| Spotting Modes | Circular Spot, Linear Strip, Contact & Non-Contact |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TS-20E |
| Operation Mode | Fully Automatic |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmittance Absorption, Transmittance Fluorescence |
| Wavelength Range | 190–800 nm |
| Light Sources | Xenon Lamp, Tungsten-Halogen Lamp, High-Pressure Mercury Lamp |
| Monochromator | Holographic Grating (1200 lines/mm) with Nitrogen Purge Capability |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | < 1 nm |
| Wavelength Repeatability | < 0.2 nm |
| Minimum Spatial Resolution | 25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White Light |
| Sample Stage Capacity | Accommodates TLC Plates up to 200 mm × 200 mm |
| Maximum Scanning Speed | 100 mm/s |
| Syringe Volume Range | 0.2–10 mL |
| Liquid Handling Speed | 0.1–25 mL/min (Aspiration/Dispense/Clean) |
| Pre-spray Area (X/Y) | 0–100 mm / 0–200 mm |
| Full Spray Area (X/Y) | 0–200 mm / 0–200 mm |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | TU-I |
| Price Range | USD 140–700 (FOB) |
| Instrument Class | TLC Ancillary Device |
| UV Wavelengths | 254 nm & 365 nm |
| Filter Dimensions | 150 × 50 mm |
| Portability | Handheld, Compact Design |
| Compliance | Designed for laboratory-grade TLC plate inspection per standard analytical workflows |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TU-II |
| Price Range | USD 140 – 700 (FOB) |
| Instrument Type | TLC Auxiliary Equipment |
| UV Wavelengths | 254 nm & 365 nm |
| Max Sample Size | 200 × 200 mm TLC Plate |
| Design | Portable, Light-Tight Enclosure |
| UV Lamp Configuration | Dual-Wavelength Integrated Fluorescent Lamps |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Forced-Flow Centrifugal TLC System |
| UV Wavelengths | 254 nm & 365 nm |
| UV Source | Dual-Band UV Lamp |
| Separation Capacity | 100 mg – 2 g per run |
| Rotational Speed Range | 100 – 1450 rpm |
| Plate Diameter | 245 mm |
| Adsorbent Layer Thickness Options | 1, 2, 3, 4, 6, 8 mm |
| Solvent Consumption | < 350 mL per separation |
| Reusable Plates | Yes |
| Gradient Elution Capability | On-line, programmable via manual valve control |
| Plate Preparation Included | Yes (with scraper & plate former) |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | KH-CTLC-III |
| Price Range | USD 7,000–14,000 (FOB Shanghai) |
| Instrument Type | Forced-Flow Centrifugal TLC System |
| Wavelength Range | 190–700 nm |
| Light Source | Dual-Wavelength UV Lamp (254 nm & 365 nm) |
| Detection Mode | Full-Spectrum UV Absorbance Detection |
| Sample Loading Capacity | 100 mg – 2 g per run |
| Rotational Speed | 100–1450 rpm |
| TLC Plate Diameter | 245 mm |
| Plate Thickness Options | 1, 2, 3, 4, 6, 8 mm |
| Flow Rate Range | 0–20 mL/min |
| Fraction Collection | X-Y Robotic Fraction Collector (120 positions, 15 mm test tubes) |
| Medium-Pressure Column | 15 × 400 mm glass column |
| Max. Operating Pressure | 0–50 kgf/cm² (0–4.9 MPa) |
| Plate Spinning Mechanism | CNC-Machined Precision Rotating Platform |
| Pump Type | Stepper-Motor-Driven Constant-Flow Peristaltic Pump |
| Integrated Sample Filtration | In-line Cartridge Filter for Adsorption Mitigation |
| Brand | Kezhe Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | KH-ZY10E |
| Instrument Type | Fluorescence Detector-Compatible Post-Column Derivatization System |
| Temperature Range | Ambient to 150 °C |
| Temperature Accuracy | ±0.25 °C |
| Temperature Resolution | ±0.1 °C |
| Derivatization Pump Flow Rate | 0–10 mL/min |
| Flow Repeatability | ±0.1% |
| Reaction Coil Length | 10 m |
| Reactor Configuration | Modular, Single or Dual Cartridge Options |
| Mixing Architecture | Sealed Continuous-Loop Multi-Directional Flow Reactor |
| Peak Broadening Reduction | Optimized via Low-Dispersion Reaction Core Design |
| [Brand | Kingpu |
|---|---|
| Origin | Shandong, China |
| Model | GC-8890 Dedicated for DME in LPG |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Temperature Control Range | Ambient + 8°C to 420°C |
| Oven Ramp Rate | 0.1–40°C/min |
| Oven Cool-down | 450°C to 50°C in ~6 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min (7 programmable segments) |
| Carrier Gas Pressure Range & Control | 0–970 kPa (7 programmable segments) |
| Injector Max Temp | 450°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min] |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | Brewer MkIII |
| Wavelength Range | 286.5–363 nm |
| Spectral Resolution | 0.6 nm |
| Wavelength Stability | ±0.01 nm (over full operating temperature range) |
| Detector | Photomultiplier Tube (PMT) |
| Optical Design | Dual Monochromator |
| Power Supply | 230 VAC or 115 VAC |
| Operating Temperature | −20 °C to +50 °C (−50 °C to +50 °C with optional cold-weather housing) |
| Measured Parameters | Total Ozone Column, SO₂ Column, Spectral UV Irradiance (UVA, UVB, UVE), UV Index (UVI) |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SSR-3000 |
| Instrument Type | Portable / Handheld Raman Spectrometer |
| Spectral Range | 180–3300 cm⁻¹ |
| Spectral Resolution | 9 cm⁻¹ |
| Signal-to-Noise Ratio | 400:1 @ 100 ms integration time |
| Excitation Wavelength | 785 ± 0.5 nm |
| Laser Linewidth | < 0.06 nm |
| Output Power | 0–500 mW (digitally adjustable) |
| Integration Time | 10 ms – 20 min |
| Weight | < 4 kg |
| Dimensions | 370 × 270 × 120 mm |
| Power Supply | External AC 100–240 V, 50/60 Hz |
| Internal Battery | 12 V, 8000 mAh Li-ion (laptop-grade) |
| Brand | KJ Scientific |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | A–Z Series |
| Pricing | Available Upon Request |
| Brand | KJ Scientific |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SMT-100C |
| Pricing | Upon Request |
| Pen Body Diameter × Length | 12 mm × 98 mm |
| Available Tip Diameters | 3.2 mm, 6.4 mm, 9.5 mm, 12.5 mm, 16 mm, 19 mm |
| Typical Holding Force Range | 3 g to 500 g (dependent on tip size and vacuum level) |
| Tip Configuration | Straight or Bent |
| Tip Material Options | Class A (acid/alkali-resistant, solvent-resistant, heat-stable, dark reddish-brown) or Class B (high-temperature superconducting-grade conductive elastomer, black) |
| Housing Material | Anodized Aluminum |
| Brand | KJIN |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Electric Vacuum Pickup Pen |
| Pricing | Upon Request |
| Input Voltage | AC 100–240 V |
| Output Voltage | DC 12 V |
| Silicone Tubing Length | 1.5 m |
| Base Dimensions | 125 mm × 67 mm × 95 mm |
| Aluminum Pen Body | Ø13 mm × 180 mm |
| Net Weight | ~550 g |
| Max Holding Force | 500 g |
| Available Tip Diameters | 3.4 mm, 6.4 mm, 12.5 mm, 15 mm, 16 mm |
| Corresponding Suction Forces | 50 g, 100 g, 300 g, 500 g (respectively) |
| Tip Materials | Conductive Silicone, Nitrile Rubber |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | KLY-2 |
| Pricing | Upon Request |
| Product Type | Portable Dew Point Meter |
| Measurement Range | –80 to +20 °C dew point (approx. 0.5–23,632 µL/L H₂O) |
| Accuracy | ≤±0.5 °C (at factory calibration) |
| Response Time | <30 s (63%), <60 s (90%) for rise at DP < –40 °C |
| Output Signal | 4–20 mA analog |
| Operating Media Conditions | Gas temperature < +60 °C, pressure < 2 MPa, flow rate 200 mL/min |
| Dimensions | 260 mm × 170 mm × 300 mm (W×H×D) |