Showing 4861–4890 of 10750 results
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | KY-210B |
| Instrument Type | Universal Potentiometric Titrator |
| Application Scope | General-purpose |
| Bias Voltage Range | 0–500 mV (adjustable) |
| Chloride Ion Measurement Range | 0.1 ppm to full percentage content |
| Accuracy | < ±2% |
| Repeatability | ≤ ±0.1 mg NaCl/L (for samples ≤2 mg NaCl/L) |
| Detection Sensitivity | Cl⁻: 0.1 mg/L |
| Titration Cell Volume | 145 mL |
| Sample Mass | 0.02–0.05 g |
| Dimensions (W×D×H) | 465 × 280 × 195 mm |
| Power Consumption | 40 W |
| Operating Environment | 10–40 °C, RH ≤80%, low electromagnetic interference |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KY-3000S |
| Price Range | USD 7,000 – 14,000 |
| Detection Principle | Ultraviolet Fluorescence (UVF) for Total Sulfur |
| Compliance Standards | SH/T 0689, ASTM D5453, GB/T 34100-2017 |
| Sample Forms | Liquid, Solid, Gas (with optional injectors) |
| Detection Range | 0.2 mg/L to 5000 ppm (equivalent to 0.00002–0.5 wt%) |
| LOD | 0.2 mg/L (as S) |
| Repeatability | ±0.2 mg/L at 1.0 mg/L |
| Furnace Temp Control | Ambient to 1300 °C, ±1 °C stability |
| Carrier & Oxidant Gases | High-purity O₂ (≥99.98%), high-purity Ar (≥99.98%) |
| Power Requirement | 2 kW |
| Data Acquisition | 24-bit ADC, USB 2.0 interface, minimum detectable signal <1 µV |
| PMT Voltage | Adjustable, software-controlled |
| Calibration Modes | Single-point or multi-point linear/nonlinear curve fitting |
| Software Compatibility | Windows 7/10/11, macOS (via Wine-compatible runtime), Linux (CLI support) |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KY-3000S |
| Compliance Standards | GB/T 34100–2017, SH/T 0689, ASTM D5453 |
| Detection Method | UV Fluorescence (S) |
| Detection Range | 0.2 mg/L to 5000 ppm (up to % level) |
| LOD (S) | 0.2 mg/L |
| Repeatability | ±0.2 mg/L at ≤1.0 mg/L |
| Sample Types | Liquid, Solid, Gas (with optional injectors) |
| Furnace Temp Range | Ambient to 1300 °C |
| Temp Control Accuracy | ±1 °C |
| Gas Requirements | High-purity O₂ (≥99.98%), High-purity Ar (≥99.98%) |
| Power Rating | 2 kW |
| Data Acquisition | 24-bit ADC, USB Interface |
| PMT Voltage | Adjustable |
| Calibration Options | Single-point or multi-point calibration |
| Software Compatibility | Windows 7/10/11, macOS (via Wine-compatible runtime), Linux (CLI support) |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KY-3000S |
| Detection Principle | UV Fluorescence (for Total Sulfur) |
| Applicable Standards | SH/T 0689, ASTM D5453 |
| Sample Forms | Liquid, Solid, Gas (with optional injectors) |
| Detection Range | 0.2 mg/L to 5000 ppm (as S) |
| LOD | 0.2 mg/L (S) |
| Oxygen Purity | ≥99.98% |
| Argon Purity | ≥99.98% |
| Furnace Temperature Range | Ambient to 1100 °C |
| Temperature Control Accuracy | ±3 °C |
| Power Consumption | 2 kW |
| Dimensions (W×D×H) | 680 × 480 × 400 mm |
| Data Acquisition | 24-bit ADC, USB Interface |
| PMT High Voltage | Adjustable |
| Calibration Options | Single-point or multi-point curve calibration |
| Software Compatibility | Windows 7/10/11, macOS (via virtualization), Linux (CLI support) |
| Brand | KY Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | KY-3000X |
| Pricing | Available Upon Request |
| Analysis Principle | Energy-Dispersive X-ray Fluorescence (EDXRF) |
| Measurement Range (S) | 0.001–9 wt% |
| Detection Limit | 10 ppm |
| Typical Analysis Time | 60 s |
| Accuracy | Compliant with GB/T 17040, SH/T 0742–2004, ASTM D4294, and GB/T 11140 |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% at 30 °C |
| Power Supply | 220 V ±20 V, 50 Hz |
| Power Consumption | <150 W |
| Dimensions (L×W×H) | 560 × 470 × 150 mm |
| Weight | 20 kg |
| Radiation Safety | Certified for Exemption under Chinese Environmental Protection Regulations (EPA Exemption Permit Issued) |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KY-33400 |
| Price Range | USD 2,800 – 7,000 |
| Vacuum Pump | Single-stage rotary vane pump |
| Vacuum Regulation | Stainless steel needle valve |
| Filtration Control | Solenoid valve actuated negative pressure control |
| Vacuum Gauge Range | 0 to –0.1 MPa |
| Power Consumption | 180 W |
| Dimensions (L×W×H) | 380 × 400 × 400 mm |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating Environment | Temperature 0–45 °C, Relative Humidity ≤80% |
| Sample Viscosity Limit | ≤8 mm²/s at 20 °C or ≤5 mm²/s at 40 °C |
| Measurable Contaminant Range | 12–30 mg/kg |
| Applicable Fuels | Diesel with >30% FAME content, and other hydrocarbon-based fuels beyond standard viscosity limits |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KY-4 D |
| Pricing | Available Upon Request |
| Standard Compliance | GB/T 1792–1988 |
| Sample Form | Liquid |
| Measurement Range | ≥3 µg/g |
| Titration Method | Potentiometric Titration |
| Minimum Titration Volume | 0.01 mL |
| Potential Measurement Range | –1999.5 to +1999.5 mV |
| Burette Accuracy | ±0.1% F·S |
| Electrode Potential Resolution | 0.1 mV |
| Basic Error of Potential Unit | ±0.5 mV or ±0.1% of full scale |
| Relative Standard Deviation (RSD) | ≤5% |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Universal Potentiometric Titrator |
| Model | KY-4Br |
| Measurement Principle | Coulometric Titration (Microcoulometry) |
| Measurement Range | Bromine Number: 0–300 g Br/100g oil |
| Bromine Index | 1–1000 mg Br/100g oil |
| Detection Limit | 1 mg Br |
| Accuracy | ±3% ±0.2 g Br (bromine number) |
| Resolution | 0.01 mg Br |
| Bias Voltage Range | 0–500 mV |
| Sample Volume | <10 µL (bromine number) |
| Reagent Consumption | <1 mL per sample |
| Power Consumption | 20 W |
| Compliance Standards | SH/T 0630–1996, SH/T 1551–2018, GB/T 11136–1989(2004), SH/T 1767–2008(2015), GB/T 1815–1997, ASTM D1492 |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | KY-4D |
| Instrument Type | Alkaline Nitrogen & Mercaptan Sulfur Analyzer |
| Application Scope | General-purpose petroleum product analysis |
| Measurement Range | ≥3 µg/g |
| Burette Resolution | 0.01 mL |
| Potentiometric Accuracy | ±0.1% F.S. |
| Potential Measurement Range | (0 to ±1999.5) mV |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | KY-4S |
| Price | Upon Request |
| Standard Compliance | GB/T 1792–1988 |
| Sample Form | Liquid |
| Measurement Range | ≥3 µg/g |
| Titration Method | Potentiometric Titration |
| Minimum Dispensed Volume | 0.01 mL |
| Potential Measurement Range | ±1999.5 mV |
| Burette Accuracy | ±0.1% F·S |
| Electronic Unit Basic Error | ±0.1% of full scale + 0.5 mV |
| Relative Error | ≤5% |
| Control Platform | Windows-based PC Interface |
| Electrode Input | Dual High-Impedance Input |
| Endpoint Detection | Automatic Potential Inflection Point Recognition |
| Fluid Handling | Automated Reagent Refill and Fixed-Volume Dispensing |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | KY-6 |
| Instrument Category | Automatic Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | ≥0.001 mg KOH/g |
| Potentiometric Measurement Range | −2000.0 to +2000.0 mV |
| Electronic Unit Basic Error | ±0.1% F·S ± 0.1 mV |
| Input Impedance | ≥1 × 10¹² Ω |
| Burette Capacity | 10 mL |
| Minimum Dispensing Volume | 0.001 mL |
| Burette Accuracy | ±0.1% F·S |
| Titration Accuracy | ±0.1% F·S |
| Endpoint Detection | Adaptive endpoint recognition via smoothed titration curve analysis |
| Compliance Standards | GB/T 7304–2000, GB/T 18609–2010 |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | KY-HW2A |
| Price Range | USD 14,000–42,000 (FOB) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Combustion System | High-Frequency Induction Furnace (2200 W, 20 MHz) |
| Carbon Range | 0.0005–6.0000 wt% (extendable to 99.999%) |
| Sulfur Range | 0.0005–0.3500 wt% (extendable to 99.999%) |
| Sample Mass (steel standard) | 0.5 g typical |
| Sensitivity | 0.1 ppm for both C and S |
| Precision | Compliant with ISO 9556 (carbon) and ISO 4935 (sulfur) |
| Analysis Time | Adjustable 20–100 s (standard: 35 s) |
| Duty Cycle | Continuous 24 h operation |
| Dust Filter Pore Size | 0.4 µm metallic sintered filter |
| Optical Coupling | Agilent 1521/2521 high-speed fiber-optic interface |
| Detector | High-stability pyroelectric infrared detector with gold-plated analysis cell |
| Light Source | Custom platinum-based IR emitter |
| ADC Resolution | 24-bit ADS1224 |
| Control Architecture | Dual-CPU modular design (Atmega162 lower-level controller) |
| Communication Interface | USB 2.0 |
| Power Supply | Industrial-grade linear regulated module |
| Brand | KYKY |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-made) |
| Model | ZQJ-2000 |
| Price Range | USD 14,000 – 42,000 |
| Minimum Detectable Leak Rate | <2×10⁻¹¹ Pa·m³/s |
| Leak Measurement Range | 2×10⁻¹¹ – 1×10⁻⁵ Pa·m³/s |
| Maximum Inlet Pressure | 1000 Pa |
| Response Time | ≤2 s |
| Pump-down Time | <8 min |
| Power Supply | 220 V AC ±10%, 50 Hz, 16 A |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤80% RH |
| Dimensions (L×W×H) | 645×450×950 mm |
| Weight | 80 kg |
| Communication Interfaces | RS232, External I/O, Parallel Printer Port |
| Brand | KYKY |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | ZQJ-2300 |
| Price Range | USD 14,000 – 42,500 |
| Minimum Detectable Leak Rate | 2.0×10⁻¹¹ Pa·m³/s |
| Measurement Range | 1×10⁻¹¹ – 1×10⁻⁵ Pa·m³/s |
| Maximum Test Pressure | 1000 Pa |
| Response Time | ≤2 s |
| Pump-down/Startup Time | <7 min |
| Power Supply | 220 VAC ±10%, 50 Hz, 5 A |
| Operating Environment | 5–45 °C, RH <80% |
| Dimensions (L×W×H) | 500×354×397 mm |
| Weight | 39.5 kg |
| Brand | KYKY |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | ZQJ-3200 |
| Detection Sensitivity (Vacuum Mode) | 5×10⁻¹¹ Pa·m³/s |
| Measurement Range | 5×10⁻¹³ – 1×10¹ Pa·m³/s |
| Maximum Inlet Pressure (Leak Test Mode) | 2500 Pa |
| Large-Leak Mode Operating Pressure | up to 10,000 Pa |
| Helium Pumping Speed (Large-Leak Mode) | 2.5 L/s |
| Response Time | ≤1 s |
| Warm-up Time | <3 min |
| Power Supply | 220 VAC ±10%, 50 Hz, 8 A |
| Operating Environment | 5–45 °C, RH <80% |
| Dimensions (Desktop) | 541×422×379 mm |
| Dimensions (Trolley-Mounted) | 730.8×528×935 mm |
| Weight (Desktop) | 55 kg |
| Weight (Trolley-Mounted) | 108.5 kg |
| Filament | Dual Yttria-Coated Tungsten Filaments |
| Data Storage | Integrated SD Card |
| Interface Options | Digital I/O, Profibus, Ethernet |
| Brand | Kylin-Bell |
|---|---|
| Origin | Jiangsu, China |
| Model | BE-9000 |
| Spectral Range | 190–850 nm |
| Spectral Bandwidth | 190–850 nm (full-range xenon flash lamp) |
| Wavelength Accuracy | ±1 nm |
| Sample Volume | 0.5–2 µL |
| Optical Path Lengths | 0.05 mm, 0.2 mm, and 1.0 mm |
| dsDNA Quantitation Range | 2–15,000 ng/µL |
| Absorbance Accuracy | ±1% at 7.332 A (260 nm) |
| Absorbance Precision | 0.003 A (at 0.2 mm path) |
| Absorbance Linearity Range (10-mm equivalent) | 0.04–300 A |
| Measurement Time | <6 s |
| OD600 Range | 0.000–6.000 A |
| Detector | Hamamatsu UV-enhanced CMOS linear array sensor |
| Light Source | Pulsed xenon flash lamp |
| Display | 7-inch capacitive touchscreen (1024 × 600) |
| Operating System | Android-based embedded OS |
| Dimensions | 200 × 260 × 165 mm |
| Weight | 5 kg |
| Power Supply | DC 24 V adapter |
| Power Consumption | 25 W (operational), 5 W (standby) |
| Absorbance Stability & Repeatability | ≤0.5% (0–3 A), ≤2% (3–4 A) |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AA-510 |
| Price | Upon Request |
| Detector | AA-510D with Digital Output (RS-232/USB), 254 nm UV Detection, Baseline Noise ≤2×10⁻⁵ AU, Drift ≤4×10⁻⁵ AU/h (MeOH, 1 mL/min), LOD ≤1 ng/mL (Naphthalene/MeOH), Deuterium Lamp (Imported German) |
| Pump | AA-510P Dual-Piston High-Pressure Isocratic/Gradient Pump, Flow Range 0.001–10.000 mL/min (0.001 mL/min increments), Accuracy ≤±1% @ 1.000 mL/min / 8.5 MPa / H₂O / RT, RSD ≤0.25%, Max Pressure 42 MPa (6000 psi), Pressure Pulsation <0.1 MPa @ 1 mL/min / 5–10 MPa |
| Software | Dual-Channel Chromatography Data System (CDS) for Windows OS, Real-Time Baseline Monitoring, Auto Peak Recognition (solvent, tailing, front/back shoulder, serrated), Manual Integration Tools, Quantitation Methods (external/internal standard, normalization, group-based, exponential), Export to Excel/Word, Image Export to Photoshop/CorelDRAW, Reintegration & Archiving, Sampling Rate up to 40 Hz |
| Dimensions & Power | 360 × 260 × 170 mm, 5.9 kg, AC 110/220 V, 50/60 Hz, 60 W |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | AA-510D/A-510P |
| Pricing | Upon Request |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AMTK Multifunctional HPLC Autosampler |
| Pricing | Available Upon Request |
| Sample Capacity | 120 × 2 mL vials (2 × 60-position racks) |
| Injection Volume Range | 0.1–1000 µL |
| Precision | RSD < 0.5% (full-loop & partial-loop modes) |
| Carryover | < 0.01% |
| Linearity | R² > 0.999 |
| Injection Modes | Full-loop, Partial-loop, Needle-Over-Loop (NOL), and Zero-Dead-Volume (ZDV) |
| Quantitative Loop Options | 20, 50, 100 (standard), 200, 500 µL |
| Syringe Pump Options | 100, 250 (standard), 1000 µL |
| Valve Switching Time | < 100 ms |
| Positioning Accuracy | < 0.3 mm (XYZ 3-axis stepper motor control) |
| Wash Protocol | Dual-wall (inner + outer needle) wash with unlimited cycles |
| Dimensions | 300 × 230 × 505 mm (L × H × W) |
| Power | AC 220 V, 50 Hz |
| Communication | LAN & RS-232 |
| Software | AMTK Chromatography Workstation |
| pH Compatibility | 1–14 |
| System Integration | Fully compatible with Agilent, Waters, Shimadzu, Thermo Fisher, PerkinElmer, Elite, and other HPLC/UHPLC/IC platforms |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Model | ATD-01/20 |
| Instrument Type | Dual-Stage Thermal Desorber |
| Desorption Temperature Range | Ambient to 400 °C |
| Cryo-Focusing Trap Temperature Range | –35 °C to 400 °C |
| Desorption Recovery Rate | >98% (compound-dependent) |
| Sample Capacity | 1–20 adsorption tubes |
| Valve System | Motorized 6-port switching valve + solenoid valves |
| Transfer Line Temp. Control | Ambient to 260 °C (±1 °C) |
| Focusing Trap Flash Heating Rate | >3000 °C/min |
| Purge Flow Rate | 0–600 mL/min (adjustable) |
| Simulated Sampling Flow | 100 mL/min |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Model | CZ-100A |
| Pyrolyzer Type | Resistive Filament (Platinum Wire or Ribbon) |
| Maximum Filament Temperature | 1400 °C |
| Temperature Ramp Stages | Up to 10-step programmable heating |
| Display | Color Touchscreen with Parameter Input & Storage (12 methods) |
| Power Loss Protection | Yes |
| Integrated Gas Path | Yes, compatible with external GC/MS without modification |
| Sample Introduction | Quartz tube (wire type) or coated probe (ribbon type) |
| Onboard Probe Cleaning Mode | High-temperature bake-out at 1400 °C |
| Mounting | Direct installation onto GC inlet via dedicated bracket |
| Interface | Synchronized trigger output for real-time GC/MS control |
| Compliance | Designed for ASTM D7213, ISO 11348, and USP <621> pyrolysis-GC applications |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | JK-0A |
| Pricing | Upon Request |
| Sample Zone Temp Range | Ambient to 400 °C (1 °C increment) |
| Valve & Transfer Line Temp Range | Ambient to 160 °C (1 °C increment) |
| Temp Control Accuracy | < ±0.5 °C |
| Desorption Recovery | >85% (compound-dependent) |
| Purge Flow Rate | 0–20 mL/min (continuously adjustable) |
| Dimensions | 360 × 170 × 390 mm |
| Weight | ~10 kg |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JK-LC |
| Price Range | USD 700–1,400 (FOB) |
| Temperature Control | Heating-only (no refrigeration) |
| Temperature Range | Ambient to 100 °C |
| Temperature Stability | ±0.1 °C |
| Temperature Uniformity | ±0.1 °C (at 50 °C) |
| Repeatability | ±0.1 °C |
| Chamber Dimensions | 350 mm × 45 mm × 40 mm (L × W × H) |
| Power Supply | 220 V AC, 50 Hz |
| Display | Dual-line LED |
| Control Interface | Touch-sensitive membrane switches |
| Safety Features | Over-temperature alarm + auto cut-off |
| Mounting | Magnetic lid retention |
| Viewing Window | Integrated tempered glass viewport |
| Column Capacity | 1–2 standard HPLC columns (up to 250 mm length) |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LC-2100 |
| Instrument Type | Fast Liquid Chromatograph |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 42 MPa |
| Wavelength Range | 190–740 nm |
| Baseline Noise | ≤5×10⁻⁶ AU |
| Baseline Drift | ≤±1×10⁻⁴ AU/h |
| Detection Limit | ≤4×10⁻⁹ g/mL (naphthalene in methanol) |
| Flow Accuracy | ≤±1% @ 1.0 mL/min, 8.5 MPa, methanol, 25°C |
| Flow Precision | RSD ≤0.25% |
| Pressure Pulsation | <0.1 MPa |
| Spectral Bandwidth | 8 nm |
| Flow Resolution | 0.001 mL/min |
| UV Lamp | Deuterium lamp (2000 h lifetime), optional tungsten lamp |
| Cell Volume | 10 µL |
| Optical Path Length | 10 mm |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Model | LC-2100 |
| Flow Rate Range | 0.0001–10.0000 mL/min |
| Max Operating Pressure | 40 MPa (5800 psi) |
| Injection Volume Range | 0.1–100 µL (standard) |
| Sample Capacity | Up to 768 positions (384-well MTP × 2) |
| Column Oven Temperature Range | (Ambient −10) °C to 85 °C (CTO-20AC) |
| UV-Vis Wavelength Range | 190–700 nm |
| Baseline Noise | ≤2 × 10⁻⁵ AU (254 nm, methanol, 1.0 mL/min, 60 min warm-up) |
| Drift | ≤4 × 10⁻⁵ AU/h |
| LOD (Naphthalene) | ≤1 × 10⁻⁹ g/mL |
| Data Acquisition Rate | 500 ms (LCsolution-compatible) |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | LC2000 |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Flow Rate Range | 0.002–9.999 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Autosampler Capacity | Not Specified (Front-Panel Manual Injection Interface) |
| Injection Volume Range | Not Specified |
| Column Oven Temperature Control Range | Not Specified |
| Wavelength Range (UV/VIS Detector) | 190–700 nm |
| Data Acquisition Frequency | Not Specified |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (PRC) |
| Model | LC2100 |
| Pricing | Upon Request |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | LC2200 |
| Price | Upon Request |
| Pump Flow Range | 0.001–10.0 mL/min |
| Max Pressure | 6000 psi |
| Pump Accuracy | ±1% at 1 µL/min |
| Pump Precision | ±0.25% (0.1–10.0 mL/min) |
| UV Detector Wavelength Range | 190–700 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Spectral Bandwidth | <6 nm |
| Baseline Noise | <±2×10⁻⁵ AU |
| Baseline Drift | <4×10⁻⁴ AU (p-p) |
| D₂ Lamp Lifetime | 3500 h (1000 h warranty) |
| UV Detector Output | 0.0005–4 AU/mV (chart recorder), 4 AU/V (data system) |
| Power Supply (Pump) | 85–264 VAC, 47–63 Hz, 60 W |
| Power Supply (UV Detector) | 100–240 VAC, 50–60 Hz, 80 W |
| Dimensions & Weight | Pump — 5.9 kg |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LC3000A |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Maximum Pressure (P3210) | 42 MPa |
| Maximum Pressure (P3220) | 30 MPa |
| Flow Rate Range (P3210) | 0.001–9.999 mL/min |
| Flow Rate Range (P3220) | 0.01–49.99 mL/min |
| Flow Accuracy | ≤0.4% |
| Flow Precision (RSD) | ≤0.1% |
| UV/VIS Detector (UV3000A) | Wavelength Range 190–700 nm |
| Light Source | Deuterium Lamp (standard), Tungsten Lamp (optional) |
| Wavelength Accuracy | ≤±2 nm |
| Wavelength Repeatability | 0.4 nm |
| Absorbance Range | 0–2 AU |
| Absorbance Error | <±5% |
| Baseline Noise (254 nm) | ≤1.5×10⁻⁵ AU (dynamic, 1 mL/min, MeOH/H₂O 80:20) |
| Baseline Drift (254 nm) | ≤4×10⁻⁴ AU/h (dynamic, 1 mL/min, MeOH/H₂O 80:20) |
| Time Constants | 0.1/0.2/0.5/1/2/5/10 s |
| Auto-Zero Function | Full-scale |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LC3000A Preparative Liquid Chromatograph |
| Max. Pressure (P3210) | 42 MPa |
| Max. Pressure (P3220) | 30 MPa |
| Flow Rate Range (P3210) | 0.001–9.999 mL/min |
| Flow Rate Range (P3220) | 0.01–49.99 mL/min |
| Flow Accuracy | ≤0.4% |
| Flow Precision (RSD) | ≤0.1% |
| UV/VIS Detector Wavelength Range | 190–700 nm |
| Wavelength Accuracy | ≤±2 nm |
| Wavelength Repeatability | 0.4 nm |
| Absorbance Range | 0–2 AU |
| Absorbance Error | <±5% |
| Baseline Noise (254 nm) | ≤1.5×10⁻⁵ AU (dynamic, 1 mL/min, MeOH/H₂O = 80:20) |
| Baseline Drift (254 nm) | ≤4×10⁻⁴ AU/h (dynamic, 1 mL/min, MeOH/H₂O = 80:20) |
| Time Constants | 0.1/0.2/0.5/1/2/5/10 s |
| Scan Modes | Programmable stop-and-go wavelength scanning (start/end λ and step size user-definable) |