| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Model | CZ-100A |
| Pyrolyzer Type | Resistive Filament (Platinum Wire or Ribbon) |
| Maximum Filament Temperature | 1400 °C |
| Temperature Ramp Stages | Up to 10-step programmable heating |
| Display | Color Touchscreen with Parameter Input & Storage (12 methods) |
| Power Loss Protection | Yes |
| Integrated Gas Path | Yes, compatible with external GC/MS without modification |
| Sample Introduction | Quartz tube (wire type) or coated probe (ribbon type) |
| Onboard Probe Cleaning Mode | High-temperature bake-out at 1400 °C |
| Mounting | Direct installation onto GC inlet via dedicated bracket |
| Interface | Synchronized trigger output for real-time GC/MS control |
| Compliance | Designed for ASTM D7213, ISO 11348, and USP <621> pyrolysis-GC applications |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | JK-0A |
| Pricing | Upon Request |
| Sample Zone Temp Range | Ambient to 400 °C (1 °C increment) |
| Valve & Transfer Line Temp Range | Ambient to 160 °C (1 °C increment) |
| Temp Control Accuracy | < ±0.5 °C |
| Desorption Recovery | >85% (compound-dependent) |
| Purge Flow Rate | 0–20 mL/min (continuously adjustable) |
| Dimensions | 360 × 170 × 390 mm |
| Weight | ~10 kg |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JK-LC |
| Price Range | USD 700–1,400 (FOB) |
| Temperature Control | Heating-only (no refrigeration) |
| Temperature Range | Ambient to 100 °C |
| Temperature Stability | ±0.1 °C |
| Temperature Uniformity | ±0.1 °C (at 50 °C) |
| Repeatability | ±0.1 °C |
| Chamber Dimensions | 350 mm × 45 mm × 40 mm (L × W × H) |
| Power Supply | 220 V AC, 50 Hz |
| Display | Dual-line LED |
| Control Interface | Touch-sensitive membrane switches |
| Safety Features | Over-temperature alarm + auto cut-off |
| Mounting | Magnetic lid retention |
| Viewing Window | Integrated tempered glass viewport |
| Column Capacity | 1–2 standard HPLC columns (up to 250 mm length) |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LC-2100 |
| Instrument Type | Fast Liquid Chromatograph |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 42 MPa |
| Wavelength Range | 190–740 nm |
| Baseline Noise | ≤5×10⁻⁶ AU |
| Baseline Drift | ≤±1×10⁻⁴ AU/h |
| Detection Limit | ≤4×10⁻⁹ g/mL (naphthalene in methanol) |
| Flow Accuracy | ≤±1% @ 1.0 mL/min, 8.5 MPa, methanol, 25°C |
| Flow Precision | RSD ≤0.25% |
| Pressure Pulsation | <0.1 MPa |
| Spectral Bandwidth | 8 nm |
| Flow Resolution | 0.001 mL/min |
| UV Lamp | Deuterium lamp (2000 h lifetime), optional tungsten lamp |
| Cell Volume | 10 µL |
| Optical Path Length | 10 mm |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Model | LC-2100 |
| Flow Rate Range | 0.0001–10.0000 mL/min |
| Max Operating Pressure | 40 MPa (5800 psi) |
| Injection Volume Range | 0.1–100 µL (standard) |
| Sample Capacity | Up to 768 positions (384-well MTP × 2) |
| Column Oven Temperature Range | (Ambient −10) °C to 85 °C (CTO-20AC) |
| UV-Vis Wavelength Range | 190–700 nm |
| Baseline Noise | ≤2 × 10⁻⁵ AU (254 nm, methanol, 1.0 mL/min, 60 min warm-up) |
| Drift | ≤4 × 10⁻⁵ AU/h |
| LOD (Naphthalene) | ≤1 × 10⁻⁹ g/mL |
| Data Acquisition Rate | 500 ms (LCsolution-compatible) |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | LC2000 |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Flow Rate Range | 0.002–9.999 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Autosampler Capacity | Not Specified (Front-Panel Manual Injection Interface) |
| Injection Volume Range | Not Specified |
| Column Oven Temperature Control Range | Not Specified |
| Wavelength Range (UV/VIS Detector) | 190–700 nm |
| Data Acquisition Frequency | Not Specified |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (PRC) |
| Model | LC2100 |
| Pricing | Upon Request |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | LC2200 |
| Price | Upon Request |
| Pump Flow Range | 0.001–10.0 mL/min |
| Max Pressure | 6000 psi |
| Pump Accuracy | ±1% at 1 µL/min |
| Pump Precision | ±0.25% (0.1–10.0 mL/min) |
| UV Detector Wavelength Range | 190–700 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Spectral Bandwidth | <6 nm |
| Baseline Noise | <±2×10⁻⁵ AU |
| Baseline Drift | <4×10⁻⁴ AU (p-p) |
| D₂ Lamp Lifetime | 3500 h (1000 h warranty) |
| UV Detector Output | 0.0005–4 AU/mV (chart recorder), 4 AU/V (data system) |
| Power Supply (Pump) | 85–264 VAC, 47–63 Hz, 60 W |
| Power Supply (UV Detector) | 100–240 VAC, 50–60 Hz, 80 W |
| Dimensions & Weight | Pump — 5.9 kg |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LC3000A |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Maximum Pressure (P3210) | 42 MPa |
| Maximum Pressure (P3220) | 30 MPa |
| Flow Rate Range (P3210) | 0.001–9.999 mL/min |
| Flow Rate Range (P3220) | 0.01–49.99 mL/min |
| Flow Accuracy | ≤0.4% |
| Flow Precision (RSD) | ≤0.1% |
| UV/VIS Detector (UV3000A) | Wavelength Range 190–700 nm |
| Light Source | Deuterium Lamp (standard), Tungsten Lamp (optional) |
| Wavelength Accuracy | ≤±2 nm |
| Wavelength Repeatability | 0.4 nm |
| Absorbance Range | 0–2 AU |
| Absorbance Error | <±5% |
| Baseline Noise (254 nm) | ≤1.5×10⁻⁵ AU (dynamic, 1 mL/min, MeOH/H₂O 80:20) |
| Baseline Drift (254 nm) | ≤4×10⁻⁴ AU/h (dynamic, 1 mL/min, MeOH/H₂O 80:20) |
| Time Constants | 0.1/0.2/0.5/1/2/5/10 s |
| Auto-Zero Function | Full-scale |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LC3000A Preparative Liquid Chromatograph |
| Max. Pressure (P3210) | 42 MPa |
| Max. Pressure (P3220) | 30 MPa |
| Flow Rate Range (P3210) | 0.001–9.999 mL/min |
| Flow Rate Range (P3220) | 0.01–49.99 mL/min |
| Flow Accuracy | ≤0.4% |
| Flow Precision (RSD) | ≤0.1% |
| UV/VIS Detector Wavelength Range | 190–700 nm |
| Wavelength Accuracy | ≤±2 nm |
| Wavelength Repeatability | 0.4 nm |
| Absorbance Range | 0–2 AU |
| Absorbance Error | <±5% |
| Baseline Noise (254 nm) | ≤1.5×10⁻⁵ AU (dynamic, 1 mL/min, MeOH/H₂O = 80:20) |
| Baseline Drift (254 nm) | ≤4×10⁻⁴ AU/h (dynamic, 1 mL/min, MeOH/H₂O = 80:20) |
| Time Constants | 0.1/0.2/0.5/1/2/5/10 s |
| Scan Modes | Programmable stop-and-go wavelength scanning (start/end λ and step size user-definable) |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Domestic |
| Model | PTC-30A |
| Sample Capacity | 30-position |
| Instrument Type | Water-and-Soil Integrated Purge and Trap System |
| Dehumidification Trap Temp Range | Ambient to 240 °C (1 °C increments) |
| Valve & Transfer Line Temp Range | Ambient to 220 °C (1 °C increments) |
| Trap Cooling/Desorption Temp Range | −30 °C to 400 °C (electronic cooling, 1 °C increments) |
| Sample Heating Temp Range | Ambient to 240 °C (1 °C increments) |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Back-Flush Flow Rate | 0–100 mL/min (adjustable) |
| Sample Vial | 40 mL |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SP-7800 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analytical GC |
| Oven Temperature Range | Ambient + 4 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down Time | ~6 min (450 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–200 mL/min (N₂), 0–1000 mL/min (H₂ or He) |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | Ambient + 4 °C to 450 °C |
| Injector Pressure Setting Range | 0–100 psi (optional 0–150 psi) |
| Injector Total Flow Setting Range | 0–200 mL/min (N₂), 0–1000 mL/min (H₂ or He) |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Model | SP6890 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | Ambient + 4 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-down Rate | 450 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Control Channels | 4 independent zones |
| Temperature Stability | ±0.1 °C |
| FID Detection Limit | ≤5.0×10⁻¹¹ g/s (benzene/CS₂) |
| TCD Sensitivity | ≥2500 mV·mL/mg (benzene) |
| Dimensions | 470 × 430 × 455 mm |
| Weight | ~45 kg |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SP6900 |
| Application Field | Petrochemical Industry |
| Temperature Control | 5 independent zones, 5-step programmable ramping |
| Column Oven Range | Ambient +15°C to 399°C |
| Temperature Stability | Better than ±0.1°C |
| Heating Rate | 0.1–40°C/min |
| Time Programming | 0–255 min per step |
| TCD Sensitivity | ≥3500 mV·mL/mg (benzene) |
| Baseline Noise | ≤0.02 mV |
| Drift | <0.1 mV/h |
| Weight | ~60 kg |
| Sample Introduction | 6-port gas sampling valve |
| Data Output | Real-time purity and component quantification via PC interface |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (China) |
| Model | SP7800 |
| Pricing | Available Upon Request |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Model | TP-6000 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Vial Heating Range | Ambient to 450 °C |
| Valve & Transfer Line Temperature Control Range | Ambient to 210 °C (1 °C increment) |
| Quantitative Loop Volume | 1 mL |
| Vial Capacity | 9 positions |
| Vial Size | 10 mL |
| Temperature Stability | < ±0.5 °C |
| RSD for Peak Area | ≤1.5% (under optimized conditions) |
| Equilibration/Injection/Clean Time Range | 0–60 min (user-programmable) |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | PRC |
| Model | WS-1 |
| Price | Upon Request |
| Display | 4-digit LED, microgram (µg) resolution |
| Water Quantification Range | 5 µg – 30 mg H₂O |
| Detection Limit | 1 µg H₂O |
| Accuracy | ±3 µg for 5–1000 µg |
| Electrolysis Current | 0–300 mA (auto-controlled) |
| Power Supply | 220 V ±10%, 50 Hz ±5% |
| Power Consumption | <40 VA |
| Operating Temperature | 5–40 °C |
| Operating Humidity | ≤85% RH |
| Dimensions (W×D×H) | 450 × 230 × 200 mm |
| Weight | ~7 kg |
| Brand | Kyoyuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KY-200 |
| Price Range | USD 2,800 – 7,000 |
| Measurement Principle | Microcoulometric Titration (Electrolytic Iodine Generation) |
| Sample Forms | Liquid, Solid, Gas (with optional injectors) |
| Analyte | Total Sulfur (S) |
| Detection Range | 0.1 mg/L – 10,000 mg/L |
| LOD (S) | 0.1 mg/L |
| Repeatability | As per SH/T 0253 (Cv ≤ 3% at >10 mg/L |
| Temperature Control | Ambient to 1100 °C, ±1 °C |
| Carrier Gases | Industrial-grade N₂ and O₂ |
| Cooling Method | Intelligent Fan-based Air Cooling |
| Power Rating | 1500 W |
| Compliance Standards | SH/T 0253, GB/T 11061.4, SH/T 0222, GB/T 3208, SH/T 1147 |
| Brand | Kyoyuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KY-200 |
| Price | Upon Request |
| Principle | Microcoulometric Titration (ASTM D5808 / SH/T 0253 / GB/T 11061.4) |
| Sample Forms | Liquid, Solid, Gas (with optional injectors) |
| Detection Range | S: 0.1–10,000 mg/L |
| Cl | 0.2–10,000 mg/L |
| Detection Limit | S: 0.1 mg/L |
| Cl | 0.2 mg/L |
| Repeatability | As per ASTM/SH/GB standards (Cv ≤3% at >10 mg/L) |
| Temperature Control | Ambient to 1100 °C, ±1 °C |
| Power Requirement | 1500 W |
| Carrier Gases | Industrial-grade N₂ and O₂ |
| Cooling | Fan-cooled pyrolysis furnace with auto-start/stop logic |
| Brand | Kyoyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic (China) |
| Model | KY-200 |
| Pricing | Upon Request |
| Principle | Microcoulometric Titration (ASTM D5808 / SH/T 0253 / GB/T 11061.4) |
| Sample Forms | Liquid, Solid, Gas (with optional injectors) |
| Detection Range | S: 0.1–10,000 mg/L |
| Cl | 0.1–10,000 mg/L |
| LOD | 0.1 mg/L (S and Cl) |
| Repeatability | CV ≤3% for [S] >10 mg/L |
| Temperature Control | Ambient to 1100 °C, ±1 °C |
| Carrier Gases | Industrial-grade N₂ and O₂ |
| Cooling | Fan-cooled pyrolysis furnace (auto-start/stop) |
| Compliance | ASTM D5808, SH/T 0253, GB/T 11061.4, SH/T 0222, GB/T 3208, GB/T 18612 |
| Brand | Kyoyuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | KY-200 |
| Pricing | Upon Request |
| Standard Compliance | SH/T 0253–92, GB/T 11061–1997, SH/T 0222–1992 |
| Sample Types | Liquid, Solid, Gas (with optional injectors) |
| Analytical Method | Microcoulometric Titration |
| Bias Voltage Range | 0–500 mV |
| Measurement Range | S: 0.2–10,000 mg/L |
| Cl | 0.3–10,000 mg/L |
| Repeatability | ≤50% RSD for S ≤1.0 mg/L |
| Carrier Gases | Ambient-grade O₂ and N₂ |
| Furnace Temperature Range | Ambient to 1000 °C |
| Temperature Control Accuracy | ±5 °C |
| Power Consumption | 1500 W |
| Dimensions (W×D×H) | 530 × 500 × 340 mm |
| Brand | Kyoyuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | KY-200CL |
| Price Range | USD 2,800 – 7,000 |
| Measurement Principle | Microcoulometric Titration (Silver Coulometric Detection) |
| Sample Forms | Solid, Liquid, Gas (with optional injectors) |
| Chlorine Range | 0.2 mg/L – 10,000 mg/L (dilution required above 5,000 mg/L) |
| Detection Limit | 0.2 mg/L (as Cl) |
| Precision | RSD ≤3% for [Cl] >10 mg/L |
| Temperature Control | Ambient to 1100 °C, ±1 °C |
| Power Requirement | 1500 W |
| Carrier Gases | Industrial-grade N₂ and O₂ |
| Cooling Method | Intelligent Fan-cooled Cracking System |
| Compliance Standards | GB/T 18612–2011, ASTM D5808–2009 |
| Brand | Kyoyuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | KY-214A |
| Price | Upon Request |
| Sulfur Range | 0.01–60 wt% |
| Resolution | 0.01 wt% |
| Max Sample Capacity | 24 positions |
| Avg. Analysis Time | ~5 min per sample |
| Furnace Ramp Time | 15–25 min (from ambient to setpoint) |
| Temperature Range | 700–1300 °C (user-selectable) |
| Temp. Control Accuracy | ±2.5 °C |
| Sample Mass Range | 10–999.9 mg |
| Automatic Powder Dispensing | 300 cycles per reagent box |
| Power Supply | 220 V ±20 V, 50 Hz |
| Max Instantaneous Power (Furnace) | ≤3.5 kW |
| Repeatability (St ≤1.5%) | <0.05 wt% |
| Reproducibility (St ≤1.5%) | <0.10 wt% |
| Compliance | Fully conforms to GB/T 214–2007 for total sulfur determination in coal by coulometric titration |
| Brand | Kyoyuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | KY-3000 |
| Price | Upon Request |
| Analysis Time | 1–999 s (recommended 60 s) |
| Detection Limit | 10 ppm |
| Sulfur Range | 0.001–9 wt% (petroleum matrix) |
| Accuracy | Compliant with GB/T 17040, SH/T 0742–2004, ASTM D4294, and GB/T 11140 |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% at 30 °C |
| Power Supply | 220 V ±20 V, 50 Hz |
| Power Consumption | <150 W |
| Dimensions (L×W×H) | 560 × 470 × 150 mm |
| Weight | 20 kg |
| Brand | Kyoyuan |
|---|---|
| Model | KY-3000 S/N |
| Measurement Principle | UV Fluorescence (S), Chemiluminescence (N) |
| Sample Types | Liquid, Solid, Gas (with optional injectors) |
| Detection Limits | 0.2 mg/L (S), 0.1 mg/L (N) |
| Calibration | Single- or multi-point standard calibration |
| Temperature Control Range | Ambient to 1100 °C |
| Temperature Accuracy | ±0.5% ±3 °C |
| Carrier Gas | Argon ≥99.98%, Oxygen ≥99.98% |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz, 2 kW |
| Dimensions | 680 × 480 × 400 mm |
| Compliance Standards | SH/T 0689, ASTM D5453 (S) |
| Brand | Kyoyuan |
|---|---|
| Model | KY-3000N |
| Instrument Type | Chemiluminescence Nitrogen Determinator |
| Measurement Principle | Oxidative Combustion + Chemiluminescence Detection (N) |
| Detection Range | 0.1 mg/L to 100% w/w (N) |
| Detection Limit | 0.1 mg/L (N) |
| Repeatability | ≤ ±0.1 mg/L (for X < 1.0 mg/L) |
| Sample Types | Liquid (≤20 mL), Solid (with optional solid sampler), Gas (with optional gas sampler) |
| Combustion Temperature Range | Ambient to 1100 °C |
| Temperature Control Accuracy | ±3 °C |
| Carrier & Oxidant Gases | High-purity O₂ (≥99.98%) and Ar (≥99.98%) |
| Power Consumption | 2000 W |
| Dimensions (L×W×H) | 680 mm × 480 mm × 400 mm |
| Compliance Standards | SH/T 0657, ASTM D4629 |
| Data Acquisition | 24-bit USB interface, minimum detectable signal < 1 µV |
| PMT Voltage | Adjustable |
| Calibration Options | Single-point or multi-point calibration |
| Software Features | GLP-compliant data logging, audit trail, export to CSV/PDF, password-protected user levels |
| Brand | Kyoyuan |
|---|---|
| Model | KY-3000N |
| Application | Total nitrogen analysis in liquid, solid, and gaseous petroleum & chemical samples |
| Detection Principle | Chemiluminescence detection of NO* (nitric oxide) after high-temperature oxidative pyrolysis |
| Measurement Range | 0.1 mg/L to 5000 ppm (equivalent to ~0.00001–0.5 wt%) |
| LOD | 0.1 mg/L (as N) |
| Repeatability | ≤ ±0.1 mg/L (for X < 1.0 mg/L) |
| Pyrolysis Temp Range | Ambient to 1100 °C |
| Temp Control Accuracy | ±3 °C |
| Gas Requirements | ≥99.98% purity O₂ and Ar |
| Power | 2 kW |
| Dimensions | 680 × 480 × 400 mm |
| Compliance | SH/T 0657, ASTM D4629 |
| Data Acquisition | 24-bit USB interface, signal resolution <1 µV |
| Optional Accessories | Solid/gas sampling modules, light/heavy quartz pyrolysis tubes, certified N standards |
| Brand | Kyoyuan |
|---|---|
| Model | KY-3000S |
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Detection Principle | UV Fluorescence (S) |
| Detection Range | 0.2 mg/L to 5000 ppm (up to % level) |
| LOD | 0.2 mg/L (as S) |
| Repeatability | ±0.2 mg/L at 1.0 mg/L |
| Temperature Control Range | Ambient to 1300 °C |
| Temperature Stability | ±1 °C |
| Power Consumption | 2 kW |
| Gas Requirements | High-purity O₂ (≥99.98%) and Ar (≥99.98%) |
| Data Acquisition | 24-bit ADC, USB interface, min. detectable signal <1 µV |
| Compliance Standards | SH/T 0689, ASTM D5453, GB/T 34100-2017 |
| Brand | Kyoyuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | KY-3000S |
| Detection Principle | UV Fluorescence (for Sulfur) |
| Applicable Standards | SH/T 0689, ASTM D5453 |
| Sample Types | Liquid, Solid, Gas (with optional injectors) |
| Measurement Range | 0.2 mg/L to 5000 ppm (as sulfur) |
| Detection Limit | 0.2 mg/L (S) |
| Carrier Gases | High-purity O₂ (≥99.98%), High-purity Ar (≥99.98%) |
| Furnace Temperature Range | Ambient to 1100 °C |
| Temperature Control Accuracy | ±3 °C |
| Power Consumption | 2 kW |
| Dimensions (W×D×H) | 680 × 480 × 400 mm |
| Data Acquisition | 24-bit ADC, USB interface |
| PMT Voltage | Adjustable |
| Calibration Options | Single-point or multi-point calibration |
| Software Compatibility | Windows, macOS, Linux |
| Brand | Kyoyuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | KY-3000SN |
| Detection Method (S) | UV Fluorescence |
| Detection Method (N) | Chemiluminescence |
| Sample Types | Liquid, Solid, Gas (with optional injectors) |
| Sulfur Range | 0.2 mg/L to 100% w/w |
| Nitrogen Range | 0.1 mg/L to 100% w/w |
| LOD (S) | 0.2 mg/L |
| LOD (N) | 0.1 mg/L |
| Oxygen Purity | ≥99.98% |
| Argon Purity | ≥99.98% |
| Furnace Temp Range | Ambient to 1100 °C |
| Temp Control Accuracy | ±3 °C |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Power Consumption | 2 kW |
| Dimensions (W×D×H) | 680 × 480 × 400 mm |
| Compliance Standards | SH/T 0689, ASTM D5453 (S) |