Chemical Analysis Instruments
Filter
Showing 511–540 of 10547 results
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | CD300 Professional |
| Portability | Portable |
| Conductivity Range | 0.00 μS/cm to 200.0 mS/cm (5-range auto-scaling) |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–100 MΩ·cm |
| Salinity Range | 0–100 ppt |
| Temperature Range | −10 °C to 110 °C |
| Accuracy | ±1.0% FS (conductivity), ±0.5 °C (temperature) |
| Resolution | 0.01 μS/cm (min), 0.1 °C (temperature) |
| IP Rating | IP57 |
| Data Storage | 500 sets (manual & auto) |
| Calibration | 1–4 point, with built-in calibration guidance and validation |
| Temp Compensation | Automatic/manual (0–50.0 °C), nonlinear mode for ultrapure water (<10 μS/cm) |
| Standards Support | 8 preloaded conductivity standards (GB, ASTM D1125, ISO 7888, USP <645>) |
| Interface | USB, GLP-compliant data export |
| Power | Rechargeable battery with low-voltage indicator and auto-off |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | CD300 Standard |
| Portability | Portable |
| Conductivity Range | 0.00 μS/cm to 200.0 mS/cm (5-range auto-ranging) |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–100 MΩ·cm |
| Salinity Range | 0–100 ppt |
| Temperature Range | −10 to 110 °C |
| Accuracy | ±1.0% FS (conductivity), ±0.5 °C (temperature) |
| Resolution | 0.01 μS/cm (min), 0.1 °C (temperature) |
| Temperature Compensation | Automatic/manual (0–50.0 °C), selectable reference temp (15, 20, 25 °C) |
| Calibration | 1–4 point, with built-in calibration guidance and validation check |
| Data Storage | 100 sets (manual & auto), GLP-compliant |
| Interface | USB |
| IP Rating | IP57 |
| Display | 68 × 53 mm LCD with white backlight and real-time clock |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | CD400 Basic |
| Form Factor | Benchtop |
| Conductivity Range | 0–200 mS/cm |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–100 MΩ·cm |
| Salinity Range | 0–100 ppt |
| Temperature Range | 0–100 °C |
| Accuracy | ±1.0% FS |
| Minimum Resolution | 0.1 μS/cm |
| Calibration | 1–3 point auto-calibration with guidance & verification |
| Electrode Constants Supported | K = 0.1, 1, 10 |
| Temp Compensation | Auto/manual (0–50 °C) |
| Data Storage | 50 manual entries with min/max tracking |
| Display | 80 × 58 mm LCD, large-font |
| IP Rating | IP54 |
| Compliance | CE-marked for laboratory and industrial use |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | CD400 Educational |
| Form Factor | Benchtop |
| Conductivity Range | 0–200 mS/cm (with sub-ranges: 0–200 μS/cm, 200–2000 μS/cm, 2.00–20.00 mS/cm, 20.0–200.0 mS/cm) |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–100 MΩ·cm |
| Salinity Range | 0–100 ppt |
| Temperature Range | 0–100 °C |
| Accuracy | ±1.0% FS (conductivity), ±0.5 °C (temperature) |
| Minimum Resolution | 0.1 μS/cm |
| Temperature Compensation | Automatic/manual (0–50 °C) |
| Electrode Constants Supported | K = 0.1, 1.0, 10.0 cm⁻¹ |
| Calibration | 1–3 point auto-calibration with built-in guidance and validation |
| Standard Solution Recognition | CH & USA series (8 total) |
| Data Storage | 50 manual entries with min/max tracking |
| Display | 80 × 58 mm LCD, large-font interface |
| IP Rating | IP54 |
| Compliance | Designed for GLP-compliant educational and industrial QA/QC workflows |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | CD400 Standard |
| Form Factor | Benchtop |
| Measurement Parameters | Single-parameter (Conductivity) |
| Conductivity Range | 0–200 mS/cm |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–100 MΩ·cm |
| Salinity Range | 0–100 ppt |
| Temperature Range | 0–100 °C |
| Accuracy | ±1.0% FS |
| Minimum Resolution | 0.1 µS/cm |
| Calibration | 1–3 point auto-calibration with guidance and validation |
| Electrode Constants Supported | K = 0.1, 1.0, 10.0 cm⁻¹ |
| Temp. Compensation | Automatic/manual (0–50 °C), selectable °C/°F |
| Display | 80 × 58 mm backlit LCD with large-font digits |
| Data Storage | 200 sets with min/max tracking |
| Interface | RS-232 with PC communication software |
| Ingress Protection | IP54 |
| Compliance | Designed for GLP-compliant laboratory and industrial process monitoring environments |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | CD510 Standard |
| Form Factor | Benchtop |
| Conductivity Range | 0.00 μS/cm to 2000 mS/cm (6 sub-ranges) |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–100 MΩ·cm |
| Salinity Range | 0–100 ppt |
| Temperature Range | −10 °C to 110 °C |
| Accuracy | ±0.5% FS (conductivity), ±0.4 °C (temperature) |
| Minimum Resolution | 0.01 μS/cm |
| Temperature Compensation | Automatic/manual (0–50.0 °C), selectable β coefficient |
| Electrode Constant Selection | Yes |
| Data Storage | 500 sets (manual/auto), GLP-compliant |
| Interface | USB |
| IP Rating | IP54 |
| Display | 90 × 68 mm LCD with white backlight, time stamping |
| Calibration | 1–4 point, with CH/USA standard sets (8 preloaded) and custom solution support |
| Special Modes | Ultra-pure water stabilization, auto-endpoint hold, factory reset |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | CD510 Professional |
| Form Factor | Benchtop |
| Conductivity Range | 0.00 µS/cm to 2000 mS/cm (6 auto-ranging segments) |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–100 MΩ·cm |
| Salinity Range | 0–100 ppt |
| Temperature Range | −10 °C to 110 °C |
| Accuracy | ±0.5% FS (conductivity), ±0.4 °C (temperature) |
| Minimum Resolution | 0.01 µS/cm |
| Temp Compensation | Automatic/manual (0–50.0 °C), selectable β coefficient |
| Electrode Constant Selection | Yes |
| Data Storage | 500 entries (manual/automatic), GLP-compliant |
| Interface | USB |
| IP Rating | IP54 |
| Display | 90 × 68 mm LCD with white backlight, time stamping |
| Calibration | 1–4 point, supports CH/USA standards (8 preloaded + custom solutions) |
| Special Modes | Ultra-pure water stabilization, auto-endpoint hold, factory reset |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | PC5200 |
| Form Factor | Benchtop |
| pH Range | −2.000 to 19.999 pH |
| pH Resolution | 0.001 pH |
| pH Accuracy | ±0.002 pH |
| mV Range | ±1999.9 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.03% FS |
| Conductivity Range | 0.00 μS/cm to 2000 mS/cm (6 sub-ranges) |
| Conductivity Resolution | 0.01/0.1/1 μS/cm |
| Conductivity Accuracy | ±0.5% FS |
| Resistivity Range | 0 to 100 MΩ·cm |
| TDS Range | 0 to 100 g/L |
| Salinity Range | 0 to 100 ppt |
| Temperature Range | −10 to 100 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.4 °C |
| Temperature Compensation | Automatic or manual (0–50.0 °C) |
| Electrode Constant Selection | Yes |
| Temp. Coefficient Selection | Yes |
| Data Storage | 1000 sets (manual & auto) |
| Interface | USB |
| Compliance | GLP-compliant data management |
| IP Rating | IP54 |
| Display | 90 × 68 mm LCD with white backlight and time stamp |
| Brand | Alalis |
|---|---|
| Model | pH300 Standard |
| Type | Portable pH Meter |
| Measurement Range | -2.00 to 19.99 pH |
| Resolution | 0.01/0.1 pH |
| Accuracy | ±0.01 pH |
| Temperature Compensation | Automatic/Manual (0–100 °C) |
| Calibration Buffers | CH, USA, and NIST series (15 total) |
| Data Storage | 500 groups with USB export |
| Display | 68 × 53 mm LCD with white backlight |
| IP Rating | IP57 |
| Input Connector | 8-pin waterproof socket |
| Compliance | Supports GLP-compliant data logging and audit-ready calibration records |
| Brand | Alalis |
|---|---|
| Model | pH300 Professional |
| Type | Portable pH Meter |
| Measurement Parameters | Dual (pH & mV) |
| pH Range | −2.00 to 19.99 pH |
| pH Resolution | 0.01 / 0.1 pH |
| pH Accuracy | ±0.01 pH |
| mV Range | ±1999 mV |
| mV Resolution | 1 mV |
| Temperature Range | −10 to 110 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Calibration Buffers | CH, USA, and NIST series (15 total) |
| Calibration Points | 1–5 point auto-calibration with on-screen guidance |
| Temperature Compensation | Automatic or manual (0–100 °C) |
| Data Storage | 500 groups with timestamp, recall, and deletion |
| Connectivity | USB interface with PC software |
| Display | 68 × 53 mm LCD with white backlight and real-time clock |
| Enclosure Rating | IP57 |
| Electrode Interface | 8-pin waterproof socket |
| Default Electrodes | Tri-combination pH electrode + plastic-body ORP electrode |
| Special Modes | High-purity water pH mode, ammonia-added pure water pH mode |
| Power | Auto-off with low-battery indicator |
| Compliance | Designed for GLP-compliant field and lab use |
| Brand | Alalis |
|---|---|
| Model | pH400 Basic |
| Type | Benchtop pH Meter |
| Measurement Parameters | pH and mV (ORP) |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.01 / 0.1 |
| pH Accuracy | ±0.01 |
| Temperature Compensation | Automatic or Manual (0–100 °C) |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| mV Range | ±1999 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±0.1% FS |
| Calibration Options | 1–3 point, with CH and USA buffer series (6 total standard buffers) |
| Data Storage | 50 manual entries with min/max recall |
| Display | 80 × 58 mm LCD, large-font interface |
| Enclosure Rating | IP54 |
| Default Electrode | Plastic-body tri-combination pH electrode |
| Power | 9 V DC adapter |
| Brand | Alalis |
|---|---|
| Model | pH400 Educational |
| Type | Benchtop pH Meter |
| Measurement Parameters | pH and mV (ORP) |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.01 / 0.1 |
| pH Accuracy | ±0.01 |
| Temperature Compensation | Automatic or Manual (0–100 °C) |
| Calibration Options | 1–3 point, with CH and USA buffer series (6 standard buffers supported) |
| Display | 80 × 58 mm LCD, large-font interface |
| Data Storage | 50 manual entries with min/max recall |
| IP Rating | IP54 |
| Included Electrode | Rugged composite plastic-body pH electrode |
| Compliance | Designed for GLP-compliant educational and QC environments |
| Brand | Alalis |
|---|---|
| Model | pH400 Standard |
| Type | Benchtop pH Meter |
| Measurement Parameters | pH and mV (ORP) |
| pH Range | 0.00–14.00 pH |
| pH Resolution | 0.01 / 0.1 pH |
| pH Accuracy | ±0.01 pH |
| mV Range | ±1999 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±0.1% FS |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Calibration | 1–3 point automatic pH calibration with CH and USA buffer series (6 total standard buffers) |
| Temperature Compensation | Automatic or manual (0–100 °C) |
| Data Storage | 200 sets with min/max recall |
| Interface | RS-232 with PC communication software |
| Display | 80 × 58 mm LCD, large-font, backlit |
| Enclosure Rating | IP54 |
| Default Electrode | Plastic-body tri-combination pH electrode |
| Power | 9 V DC adapter |
| Brand | Alalis |
|---|---|
| Model | pH510 Basic |
| Type | Benchtop pH/mV/Temperature Meter |
| Measurement Principle | Potentiometric pH Determination via Glass Electrode |
| pH Range | −2.000 to 19.999 pH |
| pH Resolution | 0.001 / 0.01 / 0.1 pH (selectable) |
| pH Accuracy | ±0.002 pH |
| mV Range | ±1999.9 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.03% FS |
| Temperature Range | −10.0 to 110.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.4 °C |
| Calibration Options | CH, USA, and NIST buffer series (15 total standard buffers) |
| Calibration Points | 1–5 point automatic calibration with guided prompts and electrode diagnostics |
| Temperature Compensation | Automatic or manual (0.0 to 100.0 °C) |
| Display | 90 × 68 mm LCD with white backlight, large-font numeric readout, real-time clock |
| Data Storage | 500 sets (manual + auto-log), min/max tracking |
| GLP Compliance | Timestamped records, electrode ID logging, calibration history retention |
| Connectivity | USB interface with PC software |
| Environmental Rating | IP54 (dust-protected, splash-resistant) |
| Power | 7.9 V DC adapter |
| Electrode | Integrated high-quality plastic-body triple-junction pH electrode with built-in temperature sensor |
| Special Modes | High-purity water pH mode, ammonia-added pure water mode, redox (E<sub>H</sub>) mode, auto-hold endpoint stabilization |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | pH510 Professional |
| Instrument Type | Benchtop |
| Parameter Types | Dual (pH & mV) |
| pH Measurement Range | −2.000 to 19.999 pH |
| pH Resolution | 0.001 / 0.01 / 0.1 pH |
| pH Accuracy | ±0.002 pH |
| mV Range | ±1999.9 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.03% FS |
| Temperature Range | −10 to 110 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.4 °C |
| Calibration Buffers | CH, USA, and NIST series (15 standard solutions + user-defined) |
| Temperature Compensation | Automatic or manual (0–100.0 °C) |
| Data Storage | 500 sets (manual & auto), with min/max tracking |
| Display | 90 × 68 mm LCD with white backlight, time stamp |
| Connectivity | USB interface |
| Enclosure Rating | IP54 |
| Compliance | GLP-compliant data management |
| Brand | Alalis |
|---|---|
| Model | pH510 Standard |
| Type | Benchtop pH Meter |
| Measurement Parameters | pH and mV (Redox) |
| pH Range | −2.000 to 19.999 pH |
| pH Resolution | 0.001 / 0.01 / 0.1 pH |
| pH Accuracy | ±0.002 pH |
| mV Range | ±1999.9 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.03% FS |
| Temperature Range | −10 to 110 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.4 °C |
| Temperature Compensation | Automatic or Manual (0 to 100.0 °C) |
| Calibration Options | 1–5 point automatic calibration with CH, USA, and NIST buffer series (15 total standard buffers) |
| Special Modes | High-purity water pH mode, ammonia-added pure water pH mode, ORP (E<sub>H</sub>) mode |
| Display | 90 × 68 mm LCD with white backlight, time stamp, large-font readability |
| Data Storage | 500 groups (manual & auto), min/max tracking |
| GLP Compliance | Yes (audit-trail enabled data logging) |
| Connectivity | USB interface with PC software |
| Enclosure Rating | IP54 |
| Power Supply | 9 V DC adapter |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic (China) |
| Model | AGT-LIBS |
| Pricing | Upon Request |
| Instrument Form Factor | Benchtop |
| Integration Level | Fully Integrated System |
| Laser Pulse Energy | ≤ 100 mJ |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | LMHJ.B02 |
| Instrument Type | Handheld |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic (China) |
| Model | LMKS |
| Pricing | Upon Request |
| Instrument Type | Handheld |
| Integration | Fully Integrated Unit |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | LMKS.A01 |
| Instrument Type | Handheld |
| Integration | Fully Integrated |
| Laser Pulse Energy | 0.2 mJ |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | LT.D00 |
| Instrument Type | Benchtop |
| Integration | Fully Integrated |
| Laser Pulse Energy | 100 mJ |
| Spectral Range | 185–340 nm (expandable to 180–960 nm) |
| Optical Resolution | 0.10–0.45 nm |
| Sample Analysis Time | 1–60 s (user-configurable) |
| Sample Stage | Motorized 3D Positioning + Automatic Rotation |
| Imaging System | Integrated HD Camera + Real-time Video Feed |
| Operating System | Embedded Windows-based Industrial PC |
| Display | Color Touchscreen Interface |
| Cooling Method | Air-Cooled Laser |
| Dimensions (L×W×H) | 405 × 510 × 430 mm (screen closed) |
| Weight | 43 kg |
| Operating Voltage | AC 220 V |
| Ambient Temperature Range | 10–40 °C (optimal at 20 °C) |
| Relative Humidity | <60% RH (non-condensing) |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | PEC.A02 |
| Price Range | USD 11,200 – 21,000 |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | PJ-10 |
| Pricing | Available upon Request |
| Excitation Source | Microwave-induced Plasma (MIP) |
| Optical Range | 190–1100 nm |
| Spectral Resolution | 0.10–0.25 nm |
| Detection Limit (Cd) | 0.01 ppm |
| Analysis Time | <60 s |
| Sample Form | Direct Solid Analysis |
| Sample Preparation | Minimal—homogenization and pelletization only (no acid digestion) |
| Power Supply | 110–260 VAC |
| Dimensions (Closed) | 400 × 410 × 427 mm (L×W×H) |
| Dimensions (Open) | 400 × 410 × 662 mm |
| Weight | 32 kg |
| Power Consumption | 200 W |
| Display | 12-inch capacitive touchscreen |
| Storage | 128 GB SSD |
| Data Interfaces | 4× USB, 1× Ethernet |
| Warm-up Time to Stability | 15 min |
| Detectable Elements | Cd, Cr, Cu, Pb, Zn, Ca, Fe, and others |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | UHPLC TQMS G1 / LC-MS/MS |
| Mass Range | 2–1500 amu (standard), 2–2000 amu (G1s variant) |
| Resolution | 0.4 / 0.7 / 1.5 FWHM (full width at half maximum) |
| Application Scope | General-purpose quantitative and qualitative analysis |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | UHPLC TQMS G1 |
| Price | Upon Request |
| Application Scope | General-purpose |
| Mass Range | 2–1500 amu (G1) / 2–2000 amu (G1s) |
| Resolution | 0.4 / 0.7 / 1.5 FWHM |
| Brand | KANTO Chemical |
|---|---|
| Origin | Japan |
| Model | 01118-31 |
| CAS No. | 30586-13-1 |
| pH Transition Range | 9.4 (blue) to 14.0 (red) |
| Purity Grade | Class I (Deer Grade) |
| Loss on Drying (105 °C) | ≤10.0 % |
| Residue on Ignition (as sulfate, after drying) | ≤45.0 % |
| Packaging | 25 g per amber glass bottle |
| Storage | Store sealed in a cool, dry place |
| Key | Brand: All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BEST-300C |
| Form Factor | Benchtop |
| Conductivity Range | 5 × 10⁻⁶ – 1 × 10⁸ mS/cm |
| TDS Range | 0–100 g/L |
| Resistivity Range | 1 × 10⁻⁸ – 2 × 10⁶ Ω·cm |
| Salinity Range | 0–100 ppt |
| Temperature Range | 0–40 °C |
| Accuracy | ±0.05% of reading |
| Minimum Resolution | 0.1 μΩ |
| Voltage Ranges | 2 mV / 20 mV / 200 mV / 2 V (±0.1% rdg, resolution down to 0.1 μV) |
| Current Output | 0–1000 mA DC, adjustable |
| ranges | 1 μA to 1000 mA (±0.2% rdg ±2 digits) |
| Display | 4.3-inch LCD with auto-unit conversion |
| Interface | Dual-language (English/Chinese), PC-compatible via optional software |
| Dimensions | 330 × 340 × 120 mm |
| Power | 220 V ±10%, 50/60 Hz |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | GC Autosampler |
| Model | BKQ-20 |
| Sample Vial Capacity | 12 mL |
| Maximum Vial Count | 196 (14 × 14 array) |
| Positioning Accuracy | ±0.01 mm |
| Power Input | AC 220 V |
| Display | Blue TFT LCD |
| Dimensions (W × D × H) | 490 mm × 482 mm × 330 mm |
| GC Synchronization | Triggered via TTL/relay signal |
| Vacuum Reconditioning | Integrated for vial reuse |
| Communication Interfaces | RS-232, USB, optional Ethernet |
| Sample Injection Modes | Headspace, direct gas loop, split/splitless compatible |
| Brand | AMS Alliance |
|---|---|
| Model | FUTURA |
| Type | Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | ≥100 positions |
| Reagent Positions | ≥100 |
| Flow Cell Path Length | 15–50 mm |
| Light Source | Tungsten-Halogen Lamp |
| Analysis Rate | 15–120 samples/hour |
| Sample Volume | 0.5–100 µL |
| Peristaltic Pump | 13 rollers per channel |
| Flow Rate Range | 50–3000 µL/min |
| Linear Absorbance Range | 0–2.5 AU |
| Dimensions | 240 × 650 × 410 mm |
| Weight | 17 kg |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | PROXIMA |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | ≥100 positions |
| Reagent Positions | 1–20 |
| Flow Cell Pathlength | 15–50 mm |
| Light Source | Tungsten-Halogen Lamp |