| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Instrument Type | Double-Beam |
| Model | SPECORD 200 PLUS |
| Optical Design | Holographic Grating Monochromator |
| Detector | Dual-Thermostatted Photodiode Array |
| Wavelength Range | 190–1100 nm |
| Spectral Resolution | ≤1.2 nm (FWHM) |
| Photometric Accuracy | ±0.002 A (at 0.5 A, 1.0 A) |
| Stray Light | <0.0005% T at 220 nm |
| Beam Geometry | True Simultaneous Double-Beam |
| Wavelength Calibration | Pre-aligned Holmium Oxide Filter |
| Compliance | USP <857>, Ph. Eur. 2.2.25, FDA 21 CFR Part 11 (Audit Trail, Electronic Signatures, User Access Control) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Type | Imported Instrument |
| Model | SPECORD 210 PLUS |
| Optical Design | Double-Beam |
| Detector | Peltier-Cooled CCD Array |
| Wavelength Range | 185–1100 nm |
| Spectral Bandwidth | 0.2, 0.5, 1, 2, and 4 nm (5-step adjustable) |
| Wavelength Accuracy | < ±0.1 nm (entire range) |
| Stray Light | < 0.005% at 340 nm (NaNO₂) |
| Photometric Range | –5 to +5 A |
| Baseline Stability | ≤ 0.0001 A (RMS) |
| Long-Term Drift | ≤ 0.0005 A/h |
| Scan Speed | Up to 12,000 nm/min |
| Wavelength Reproducibility | < ±0.01 nm |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Instrument Type | Double-beam |
| Detector | CCD array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | < ±0.1 nm (full range) |
| Wavelength Repeatability | ≤ 0.02 nm |
| Spectral Bandwidth | 0.2, 0.5, 1, 2, and 4 nm (motorized selection) |
| Stray Light | < 0.0002% at 340 nm (NaNO₂) |
| Scan Speed | up to 12,000 nm/min |
| Automatic Wavelength Calibration | 内置 Ho-glass reference filter |
| Light Sources | Deuterium lamp (190–350 nm) and tungsten-halogen lamp (350–1100 nm) |
| Software | SCIENCE™ v3.x with GLP-compliant audit trail, method library, and instrument self-check (SCS) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | ZEEnit 650P |
| Instrument Type | Graphite Furnace AAS |
| Background Correction | Dual-mode Zeeman (2-field / 3-field / dynamic field) + D₂ lamp |
| Furnace Design | Transversely Heated Graphite Atomizer (THGA) |
| Automation Level | Fully Automated with Integrated Autosampler, 8-Lamp Turret, RFID-enabled Lamp Recognition |
| Sample Introduction | Liquid & Solid (Direct Solid Sampling compatible) |
| Compliance Framework | Designed for GLP/GMP environments |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | ZEEnit 700P |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Concave holographic grating (1800 grooves/mm) |
| Optical System | Dual-beam with automatic single/dual-beam switching |
| Detector | Photomultiplier tube (PMT) |
| Background Correction | Deuterium lamp + Triple-magnetic-field Zeeman effect |
| Graphite Furnace | Transversely heated, temperature range: room temp to 3000 °C, max heating rate: 3000 °C/s |
| Autosampler | 108-position, programmable |
| Dimensions | 1200 × 480 × 600 mm |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena GmbH & Co. KG |
| Instrument Type | Flame–Graphite Furnace AAS |
| Monochromator | Concave Grating |
| Optical System | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Triple-Field Zeeman |
| Grating Density | 1800 lines/mm |
| Lamp Holder | Automated 8-Lamp Turret with Auto-Alignment |
| Magnetic Field Range | 0.1–1.0 T (Switchable Between 2-Field and 3-Field Zeeman Modes) |
| Graphite Furnace | Transversely Heated, Temperature Range: Room Temp to 3000 °C, Max. Ramp Rate: 3000 °C/s |
| Autosampler Capacity | Up to 108 Positions |
| Dimensions | 1200 × 480 × 600 mm |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | ZEEnit 700Q |
| Pricing | Available upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | ZEEnit 700Q |
| Instrument Type | Flame and Graphite Furnace AAS |
| Background Correction | Zeeman-effect with tunable magnetic field (2-field / 3-field / dynamic mode) + D₂ lamp |
| Automation Level | Fully automated flame and GF-AAS operation |
| Sample Introduction | Auto-sampler with intelligent dilution, 8-position encoded lamp turret with RFID support |
| Solid Sampling Option | Optional direct solid analysis module |
| Brand | Anasazi |
|---|---|
| Origin | USA |
| Model | EFT-60 |
| Operating Frequency | 60 MHz |
| Magnet Type | AlNiCo Permanent Magnet |
| Sample Form | Solid and Liquid (with appropriate probes) |
| Resolution (1H) | < 0.5 Hz |
| Sensitivity (1H) | < 0.001 mmol/L |
| Nuclei Supported | ¹H, ¹³C, ¹⁹F, ³¹P, ²³Na, ⁵⁹Co, ²⁹Si |
| Cryogen-Free Operation | Yes |
| Compliance | ASTM E2874, ISO/IEC 17025 (when operated under GLP conditions), FDA 21 CFR Part 11 (software-enabled audit trail) |
| Brand | Anasazi |
|---|---|
| Origin | USA |
| Model | EFT-60 |
| Operating Frequency | 60 MHz |
| Magnet Type | AlNiCo Permanent Magnet |
| Sample Form | Solid and Liquid (with appropriate probes) |
| Resolution (1H) | < 0.5 Hz |
| Sensitivity (1H) | < 0.001 mmol/L |
| Nuclei Supported | ¹H, ¹³C, ¹⁹F, ³¹P, ²³Na, ⁵⁹Co, ²⁹Si |
| Cryogen-Free Operation | Yes |
| Compliance | ASTM E2821, ISO/IEC 17025 (when operated under GLP conditions), FDA 21 CFR Part 11–ready software architecture |
| Brand | Anasazi |
|---|---|
| Origin | USA |
| Model | EFT-60 / EFT-90 |
| Instrument Type | Benchtop High-Field NMR Spectrometer |
| Operating Frequency | 60 MHz / 90 MHz (¹H) |
| Sample Type | Liquid Solutions |
| Resolution | < 0.5 Hz (full width at half maximum, FWHM, for 1% ethylbenzene in CDCl₃) |
| Sensitivity | ≤ 0.001 mmol/L (for ¹H, single-scan, standard 5 mm tube) |
| Magnet System | AlNiCo permanent magnet with active temperature stabilization |
| Nuclei Supported | ¹H, ¹³C, ¹⁹F, ³¹P, ²³Na, ⁵⁹Co, ²⁹Si, and other quadrupolar/nuclear spin-½ nuclei |
| Software Platform | EFT-NMR v5.x with pulse sequence library and GLP-compliant audit trail |
| Compliance | Designed to support ISO/IEC 17025, ASTM E2823, and USP <724> method validation workflows |
| Brand | Anasazi |
|---|---|
| Origin | USA |
| Model | EFT-60, EFT-90 |
| Operating Frequency | 60 MHz / 90 MHz |
| Sample Type | Liquid |
| Measurement Principle | Pulsed Fourier Transform NMR |
| Magnet Type | AlNiCo Permanent Magnet |
| ¹H Resolution | < 0.5 Hz |
| Sensitivity | < 0.001 mmol/L (for ¹H, standard sample) |
| Supported Nuclei | ¹H, ¹³C, ¹⁹F, ³¹P, ²³Na, ⁵⁹Co, ²⁹Si, and other quadrupolar/low-γ nuclei |
| Software Platform | EFT-NMR Console v4.x |
| Compliance | ASTM E2857, ISO/IEC 17025 (method validation support), GLP-ready audit trail logging |
| Brand | Anasazi |
|---|---|
| Origin | USA |
| Model | EFT-60, EFT-90 |
| Operating Frequency | 60 MHz / 90 MHz |
| Sample Type | Liquid |
| Measurement Principle | Pulsed Fourier Transform NMR |
| Magnet Type | AlNiCo Permanent Magnet |
| Resolution (1H) | <0.5 Hz |
| Sensitivity | <0.001 mmol/L |
| Nuclei Supported | ¹H, ¹³C, ¹⁹F, ³¹P, ²³Na, ⁵⁹Co, ²⁹Si, and other quadrupolar/nuclear spin-½ nuclei |
| Compliance | ASTM E2874, ISO/IEC 17025-compatible operation, GLP-ready data audit trail |
| Brand | Anasazi |
|---|---|
| Origin | USA |
| Model | EFT-90 |
| Operating Frequency | 90 MHz |
| Sample Type | Solid & Liquid (Broadband) |
| Magnet Type | AlNiCo Permanent Magnet |
| Resolution | < 0.5 Hz (at 90 MHz, 1H, in DMSO-d6) |
| Sensitivity | < 0.001 mmol/L (for 1H, typical small-molecule sample) |
| Cryogen-Free Operation | Yes (No Liquid Helium or Liquid Nitrogen Required) |
| Compliance | ASTM E2831-18 (Standard Guide for NMR Spectroscopy Data Reporting), ISO/IEC 17025:2017 (for lab accreditation readiness), GLP/GMP-compatible data audit trail via software |
| Brand | Anasazi |
|---|---|
| Origin | USA |
| Model | EFT-90 |
| Operating Frequency | 90 MHz |
| Sample Type | Solid & Liquid (with appropriate probes) |
| Magnet Type | AlNiCo permanent magnet |
| Resolution | < 0.5 Hz (for 1H at 90 MHz) |
| Sensitivity | < 0.001 mmol/L (for 1H) |
| Cooling | Zero-boil-off, helium-free operation |
| Compliance | Designed for GLP-compliant academic and industrial R&D environments |
| Software | EFT-NMR v5.x with full pulse sequence library and audit trail capability |
| Brand | Anasys |
|---|---|
| Origin | USA |
| Model | nanoIR2-FS |
| Instrument Type | Laboratory Benchtop System |
| Core Principle | Photothermal Induced Resonance (PTIR) Coupled with Atomic Force Microscopy (AFM-IR) |
| Spectral Range | 1000–4000 cm⁻¹ (Standard Tunable Quantum Cascade Laser Source) |
| Spatial Resolution | <10 nm |
| Spectral Acquisition Speed | <3 s per spectrum |
| Data Sampling Interval | Adjustable down to 0.25 cm⁻¹ (FT-based spectral reconstruction) |
| Sample Mode | Ambient or Controlled Environment (N₂-purged optional) |
| Compatible Chemometrics Software | Anasys IR-Spectra™ (with NIST-compatible spectral libraries, ASTM E1421-22 compliant preprocessing) |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Alioth-π |
| Price Range | USD 4,200 – 5,600 (FOB) |
| Detection Limit (Pb in aqueous matrix) | <0.3 mg/L |
| Detection Limit (Cd in aqueous matrix) | <0.5 mg/L |
| Measurement Time | 60 s per analysis |
| Detector Resolution | ≤145 eV (Mn Kα) |
| X-ray Tube | Transmission-target microfocus tube |
| Optical Path | Optimized 3D ultra-short path (sample–tube–detector) with multilayer scatter suppression coating |
| Camera | Integrated 1-MP visible-light imager with real-time video capture |
| Enclosure Rating | IP67-equivalent dual-layer liquid ingress protection |
| Housing Material | Aerospace-grade Al-Mg alloy |
| Software Algorithm | Holographic Fundamental Parameters (FP) quantification engine |
| Operating Mode | PC-controlled or standalone tablet interface |
| Warm-up Time | <3 s |
| Power Supply | Rechargeable Li-ion battery (8+ hrs continuous operation) |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | DUBHE-1610 |
| Detection Limit (LLD) | 0.4 ppm (S) |
| Measurement Range | 0.4 ppm – 5 wt% |
| Analysis Time | 60–300 s |
| Repeatability | ≤0.2 ppm (at 2 ppm S), ≤0.5 ppm (at 10 ppm S), ≤2.5 ppm (at 50 ppm S) |
| Excitation Line | Cr Kα (5.41 keV) |
| Optical Configuration | Dual Polycapillary Focusing Monochromator + Full-Focus Bent Crystal Analyzer |
| Sample Preparation | ESP (Easy Sample Prepare) System |
| Operating Mode | Benchtop, Air-path, No Gas or Solvent Consumption |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | DUBHE-1710 |
| Detection Limit (Cl) | 0.1 ppm |
| Measurement Range | 0.1 ppm – 5 wt% |
| Analysis Time | 60–300 s |
| Repeatability | ≤0.2 ppm (at 1 ppm Cl), ≤0.5 ppm (at 5 ppm Cl), ≤2.5 ppm (at 50 ppm Cl) |
| Sample Prep Time | <10 s |
| Operating Warm-up | ≤10 min |
| Cost per Sample | <USD 0.55 (excl. labor) |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | MEGREZ-A |
| Excitation | Dual X-ray tube sources with polycapillary-focusing monochromators |
| Detection Principle | Energy-dispersive X-ray fluorescence (ED-XRF) with monochromatic excitation |
| Elemental Range | Z ≥ 5 (Boron and heavier elements) |
| Detection Limit (Heavy Metals) | As low as 0.05 mg/kg (matrix-dependent) |
| Quantification Method | Fast fundamental parameters (FP) algorithm with minimal or zero calibration standards |
| Compliance | Designed for ISO 8258, ASTM E1621, and GB/T 30091–2013 compliant workflows |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | MERAK-CEMII |
| Price Range | USD 70,000 – 140,000 |
| Compliance | GB/T 176–2008 |
| Elements Analyzed | Na, Mg, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn |
| Detection Principle | Wavelength-Dispersive XRF (WDXRF) with High-Flux Doubly Curved Crystal Spectrometer (HF DCCS) and Secondary Target Excitation |
| Sample Form | Solid powders (pressed pellets or fused beads) |
| Vacuum/Atmosphere | Ambient air operation (no vacuum pump or He purge required) |
| Cooling | Peltier-cooled detector (no liquid nitrogen) |
| Stability | Ready for measurement within 3 minutes after power-on |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | MERAK-LEII |
| Detection Range | Na–Ti (extendable to C, N, O, F) |
| Light Element LLDs | S ≤ 0.2 ppm, Cl ≤ 0.1 ppm, Si ≤ 0.8 ppm |
| Excitation | Monochromatized Wavelength-Selective X-ray Beam via Focusing Polycapillary Optics |
| Optical Architecture | Fixed X-Ray Path System (XFS) |
| Sample Form | Solid, Liquid, or Powder in Disposable Cups/Membranes |
| Compliance | Designed for ASTM D2622, D4294, D7039, ISO 8754, IP 287, and USP <233> elemental impurity testing workflows |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | MERAK-MINI |
| Detection Limit (S) | 0.5 ppm (300 s) |
| Detection Limit (Cl) | 0.3 ppm (300 s) |
| Quantification Range | 0.5 ppm – 5% |
| Analysis Time | 60–300 s |
| Repeatability | RSD ≤ 3% @ 10 ppm S, RSD ≤ 1.5% @ 1000 ppm S |
| Dimensions | 350 mm × 230 mm × 370 mm |
| Weight | 12.5 kg |
| Power Consumption | 80 W |
| Operating Temperature | 5–40 °C |
| Battery Life | >4 h |
| Compliance | ASTM D7039, ASTM D7536, ISO 20884, ISO 15597 |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | MERAK-SC |
| Excitation | Monochromatic Focused X-ray (Johansson-type DCC crystal) |
| Detection | Ultra-thin Graphene-window Silicon Drift Detector (SDD) |
| Elemental Range | F–Cl (light elements), K–Zn (transition metals) |
| LOD (F) | 0.15 wt% (300 s, aqueous matrix) |
| LOD (Al–Cl) | 0.0002–0.005 wt% (300 s) |
| Sample Types | Liquids, powders, solids |
| Geometry | Top-illumination |
| Sample Rotation | Motorized, software-controlled |
| Temperature Control | 24 ± 0.3 °C |
| Analysis Time | 30–300 s per sample |
| Stability | < ±3% intensity drift over 24 h |
| Quantification Engine | Fast FP 2.0 fundamental parameters software |
| Compliance | Designed for ISO 8258 (control charts), ASTM E1621 (ED-XRF for cement), USP <233> (elemental impurities), and GLP/GMP-aligned data integrity workflows |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MERAK-TINY |
| Pricing | Upon Request |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | PHECDA-ECO |
| Element Range | Mg–U |
| LOD (soil matrix, 600 s) | Cd: 0.06 mg/kg, Pb: 0.4 mg/kg, Cr: 1.0 mg/kg |
| Repeatability (Cd, soil) | ≤0.3 mg/kg, RSD <15% |
| Sample Types | Solid, liquid, powder, viscous |
| Detector | High-performance Silicon Drift Detector (SDD) |
| Excitation | Monochromatic focused excitation via doubly curved crystal (DCC) |
| Method | Single-wavelength excitation + energy-dispersive detection |
| Software | Fast FP® quantitative engine with matrix-adaptive modeling |
| Optional Preconcentration | Heavy Metal Enrichment Tape (HMET®) for aqueous samples (LOD: 1–3 µg/L) |
| Weight | 7.5 kg |
| Dimensions | 370 × 290 × 190 mm |
| Operation | Ambient air, no vacuum/gas required |
| Sample Interface | Motorized sample rotation stage |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | PHECDA-FVS |
| Instrument Type | Micro-Zone ED-XRF |
| Elemental Range | Mg to U |
| Detection Limits (Large Spot Mode, Light Matrix) | S: 10 mg/kg, Fe: 2 mg/kg, Pb: 1.0 mg/kg, Cd: 0.3 mg/kg |
| Minimum Focal Spot | φ200 µm |
| Spot Size Options | Software-Selectable Apertures (φ200–φ5000 µm, Rectangular Beam Optional) |
| X-Y Stage Range | ±10 mm |
| Step Resolution | 10 µm |
| Camera Magnification | 10×–100× |
| Sample Chamber Dimensions | 280 × 230 × 70 mm (L×W×H) |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | PHECDA-HE & PHECDA-HES |
| Detection Limit (soil matrix, 300 s) | Cd: 0.06 mg/kg, Pb: 0.4 mg/kg, Cr: 1.0 mg/kg |
| Repeatability (Cd, soil) | RSD < 15% at 0.3 mg/kg |
| Elemental Range | Mg–U |
| Sample Types | Solid, liquid, powder, viscous |
| Detector | High-performance Silicon Drift Detector (SDD) |
| Excitation Principle | Monochromatic focused excitation via doubly curved crystal (DCC) |
| Software | Fast FP® 2.0 quantitative engine |
| Auto-sampler | 30+ positions (PHECDA-HES) |
| HMET® integration for aqueous samples (detection limit | 1–3 µg/L) |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | PHECDA-PRO |
| Excitation Principle | Monochromatic Focused Excitation (using doubly curved crystal monochromator) |
| Detection Principle | Energy-Dispersive XRF (ED-XRF) |
| Elemental Range | Mg–U |
| LOD (soil matrix, 600 s) | Cd: 0.06 mg/kg, Pb: 0.4 mg/kg, Cr: 1.0 mg/kg |
| Precision (RSD) | Cd <15% at 0.3 mg/kg (soil, 600 s) |
| Sample Types | Solids, powders, slurries, liquids (with HMET® membrane enrichment), filters (e.g., PM₂.₅), and viscous matrices |
| Detector | High-performance silicon drift detector (SDD) with optimized active area and energy resolution |
| Software | Fast FP® quantitative engine (fundamental parameters-based, matrix-adaptive, standard-free or minimal-standard calibration) |
| Optional Enhancement | Heavy Metal Enrichment Technology (HMET®) for aqueous samples (LOD: 1–3 µg/L) |
| Portability | 8.7 kg |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | DV-420A-BV |
| Spectral Range | 300–1000 nm |
| Pixel Array | 1024 × 256 |
| Pixel Size | 26 × 26 µm |
| Imaging Area | 26.6 × 6.7 mm |
| Peak Quantum Efficiency | 95% |
| Maximum Cooling Temperature | −75 °C |
| Full Well Capacity (typ.) | 510 k e⁻ |
| Register Capacity (typ.) | 1 M e⁻ |
| Maximum Spectral Acquisition Rate | 75 spectra/s |
| Read Noise (typ.) | 4 e⁻ |
| Readout Speeds | 0.1 / 0.05 / 0.033 MHz |
| ADC Resolution | 16-bit |
| Dark Current (@−70 °C) | 0.002 e⁻/pixel/s |
| Interface | USB 2.0 |
| Vacuum Packaging | Andor UltraVac™ |
| Cleanroom Assembly | ISO Class 4 (10,000) |
| Compliance | CE, RoHS |