Chemical Analysis Instruments
Filter
Showing 661–690 of 10556 results
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | PlasmaQuant 9100 |
| Instrument Type | Laboratory ICP-OES |
| Application Scope | Universal |
| Compliance | ASTM D5185, ISO 11885, USP <232>/<233>, EPA Methods 200.7, 200.8, 6010D, 6020B |
| Optical Resolution | ≤2 pm at 200 nm |
| Wavelength Range | 160–900 nm |
| Detector | High-resolution CCD with 43,000 resolvable emission lines |
| RF Generator | Self-oscillating 40 MHz, 700–1700 W |
| Plasma Observation | Enhanced 2+2 dual-view (axial + radial, with signal attenuation and torch tail-flame suppression) |
| Torch Design | V-Shuttle detachable quartz torch with auto-alignment and argon interlock |
| Warm-up Time | <15 min (cold start to quantitative analysis) |
| Software | PQ 9000 Suite with 21 CFR Part 11 compliance mode, audit trail, electronic signatures |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Imported Instrument |
| Model | PlasmaQuant 9100 |
| Detection Principle | Full-Spectrum Direct-Reading ICP-OES |
| Optical Range | 160–900 nm |
| Optical Resolution | ≤3 pm |
| Wavelength Accuracy | <0.0004 nm |
| Observation Modes | Dual-View (Radial + Axial) with Four Simultaneous Viewing Configurations |
| Plasma System | High-Stability, High-Power RF Generator (27.12 MHz) |
| Detector | Back-Illuminated CCD with Deep-UV Sensitivity |
| Startup Time | <5 minutes |
| Gas Efficiency | Integrated Plasma Gas Recycling for Cooling & Purge Streams |
| Software | Aspect PQ with ABC and CSI Background Correction Algorithms |
| Compliance | Designed for GLP/GMP environments |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Imported |
| Model | PlasmaQuant 9200 |
| Instrument Category | Full-Spectrum Simultaneous ICP-OES |
| Wavelength Range | 160–900 nm |
| Optical Resolution | 0.002 nm (at 200 nm) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PlasmaQuant MS |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Mass Range (amu) | Not Specified |
| Mass Resolution (Unit Mass Resolution, amu) | Not Specified |
| Detection Limit (ng·L⁻¹) | Not Specified |
| Sensitivity (Mcps/mg·L⁻¹) | Not Specified |
| Short-Term Stability (RSD) | Not Specified |
| Long-Term Stability (RSD) | Not Specified |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | PlasmaQuant MS |
| Instrument Type | Full-Spectrum Direct-Reading ICP-MS |
| Detection Limits | Be ≤ 0.1 ppt, Co ≤ 0.2 ppt, In ≤ 0.05 ppt, Bi ≤ 0.05 ppt, U ≤ 0.01 ppt |
| Precision (RSD) | < 3% |
| Short-Term Stability | < 3%, Long-Term Stability: < 4% |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Instrument Type | Quadrupole ICP-MS |
| Model | PlasmaQuant MS |
| Application Domain | Laboratory-based elemental and isotopic analysis |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Gas Consumption | <9 L/min Ar plasma gas |
| Oxide Rate (CeO⁺/Ce⁺) | ≤1.8% |
| Double-Charge Rate (Ba²⁺/Ba⁺) | ≤2% |
| Detection Limit Performance | 7Li ≥100 Mcps/ppm, 115In ≥500 Mcps/ppm, 238U ≥500 Mcps/ppm |
| Dynamic Range | 0.1–10¹⁰ cps (11-decade linear range in pulse-counting mode) |
| Quadrupole Drive Frequency | 3.0 MHz |
| Mass Scan Speed | 5115 amu/s |
| Minimum Dwell Time | 50 µs |
| iCRC Collision/Reaction Cell | Dual-gas (He/H₂) configurable, with BOOST technology for sensitivity preservation |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PQ LC–PlasmaQuant MS |
| Instrument Type | Triple Quadrupole ICP-MS Coupled with Liquid Chromatography |
| Application Scope | Universal Elemental Speciation |
| Interface Configuration | Integrated LC–ICP-MS Coupling Kit |
| Software Platform | Clarity Chromatography Software (DataApex) + ASpect MS |
| Regulatory Compliance | FDA 21 CFR Part 11–Ready, GLP/GMP-Compatible Data Handling |
| Automation Level | Fully Automated Unattended Operation Support |
| Column Compatibility | Reversed-Phase HPLC, Ion Chromatography (IC), Size-Exclusion Chromatography (SEC) |
| Detection Capability | Sub-ng/kg LODs for As/Cr species |
| Dynamic Range | 11 orders of magnitude (ADD11 digital detector) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | RXN |
| Instrument Type | In-line Raman Spectrometer |
| Probe Compatibility | PhAT and non-PhAT probes |
| Sample Phase Support | Solid and liquid (dual-channel configuration) |
| Optical Spot Size Range | 1 µm to 6 mm |
| Application Environment | Certified for hazardous / classified areas (ATEX/IECEx compliant) |
| Spectral Resolution | High (typical < 4 cm⁻¹ FWHM) |
| Architecture | Modular, rack-mountable industrial platform |
| Software Compliance | Supports 21 CFR Part 11 audit trail, electronic signatures, and GLP/GMP data integrity requirements |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Type | Imported Instrument |
| Model | SPECORD 200 PLUS |
| Optical Design | Double-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Automation | Motorized Wavelength Scanning |
| Spectral Bandwidth | 1.4 nm |
| Wavelength Accuracy | < ±0.1 nm (full range) |
| Wavelength Repeatability | < ±0.01 nm |
| Stray Light | < 0.005% @ 340 nm (NaNO₂) |
| Baseline Stability | ≤ 0.0001 A (RMS) |
| Photometric Range | –5 to +5 A |
| Scan Speed | 12,000 nm/min |
| Light Sources | Deuterium Lamp + Tungsten-Halogen Lamp (automatically switched) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Instrument Type | Double-Beam |
| Model | SPECORD 200 PLUS |
| Optical Design | Holographic Grating Monochromator |
| Detector | Dual-Thermostatted Photodiode Array |
| Wavelength Range | 190–1100 nm |
| Spectral Resolution | ≤1.2 nm (FWHM) |
| Photometric Accuracy | ±0.002 A (at 0.5 A, 1.0 A) |
| Stray Light | <0.0005% T at 220 nm |
| Beam Geometry | True Simultaneous Double-Beam |
| Wavelength Calibration | Pre-aligned Holmium Oxide Filter |
| Compliance | USP <857>, Ph. Eur. 2.2.25, FDA 21 CFR Part 11 (Audit Trail, Electronic Signatures, User Access Control) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Type | Imported Instrument |
| Model | SPECORD 210 PLUS |
| Optical Design | Double-Beam |
| Detector | Peltier-Cooled CCD Array |
| Wavelength Range | 185–1100 nm |
| Spectral Bandwidth | 0.2, 0.5, 1, 2, and 4 nm (5-step adjustable) |
| Wavelength Accuracy | < ±0.1 nm (entire range) |
| Stray Light | < 0.005% at 340 nm (NaNO₂) |
| Photometric Range | –5 to +5 A |
| Baseline Stability | ≤ 0.0001 A (RMS) |
| Long-Term Drift | ≤ 0.0005 A/h |
| Scan Speed | Up to 12,000 nm/min |
| Wavelength Reproducibility | < ±0.01 nm |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Instrument Type | Double-beam |
| Detector | CCD array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | < ±0.1 nm (full range) |
| Wavelength Repeatability | ≤ 0.02 nm |
| Spectral Bandwidth | 0.2, 0.5, 1, 2, and 4 nm (motorized selection) |
| Stray Light | < 0.0002% at 340 nm (NaNO₂) |
| Scan Speed | up to 12,000 nm/min |
| Automatic Wavelength Calibration | 内置 Ho-glass reference filter |
| Light Sources | Deuterium lamp (190–350 nm) and tungsten-halogen lamp (350–1100 nm) |
| Software | SCIENCE™ v3.x with GLP-compliant audit trail, method library, and instrument self-check (SCS) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | ZEEnit 650P |
| Instrument Type | Graphite Furnace AAS |
| Background Correction | Dual-mode Zeeman (2-field / 3-field / dynamic field) + D₂ lamp |
| Furnace Design | Transversely Heated Graphite Atomizer (THGA) |
| Automation Level | Fully Automated with Integrated Autosampler, 8-Lamp Turret, RFID-enabled Lamp Recognition |
| Sample Introduction | Liquid & Solid (Direct Solid Sampling compatible) |
| Compliance Framework | Designed for GLP/GMP environments |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena GmbH & Co. KG |
| Instrument Type | Flame–Graphite Furnace AAS |
| Monochromator | Concave Grating |
| Optical System | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Triple-Field Zeeman |
| Grating Density | 1800 lines/mm |
| Lamp Holder | Automated 8-Lamp Turret with Auto-Alignment |
| Magnetic Field Range | 0.1–1.0 T (Switchable Between 2-Field and 3-Field Zeeman Modes) |
| Graphite Furnace | Transversely Heated, Temperature Range: Room Temp to 3000 °C, Max. Ramp Rate: 3000 °C/s |
| Autosampler Capacity | Up to 108 Positions |
| Dimensions | 1200 × 480 × 600 mm |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | ZEEnit 700P |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Concave holographic grating (1800 grooves/mm) |
| Optical System | Dual-beam with automatic single/dual-beam switching |
| Detector | Photomultiplier tube (PMT) |
| Background Correction | Deuterium lamp + Triple-magnetic-field Zeeman effect |
| Graphite Furnace | Transversely heated, temperature range: room temp to 3000 °C, max heating rate: 3000 °C/s |
| Autosampler | 108-position, programmable |
| Dimensions | 1200 × 480 × 600 mm |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | ZEEnit 700Q |
| Pricing | Available upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | ZEEnit 700Q |
| Instrument Type | Flame and Graphite Furnace AAS |
| Background Correction | Zeeman-effect with tunable magnetic field (2-field / 3-field / dynamic mode) + D₂ lamp |
| Automation Level | Fully automated flame and GF-AAS operation |
| Sample Introduction | Auto-sampler with intelligent dilution, 8-position encoded lamp turret with RFID support |
| Solid Sampling Option | Optional direct solid analysis module |
| Brand | Anasazi |
|---|---|
| Origin | USA |
| Model | EFT-60 |
| Operating Frequency | 60 MHz |
| Magnet Type | AlNiCo Permanent Magnet |
| Sample Form | Solid and Liquid (with appropriate probes) |
| Resolution (1H) | < 0.5 Hz |
| Sensitivity (1H) | < 0.001 mmol/L |
| Nuclei Supported | ¹H, ¹³C, ¹⁹F, ³¹P, ²³Na, ⁵⁹Co, ²⁹Si |
| Cryogen-Free Operation | Yes |
| Compliance | ASTM E2874, ISO/IEC 17025 (when operated under GLP conditions), FDA 21 CFR Part 11 (software-enabled audit trail) |
| Brand | Anasazi |
|---|---|
| Origin | USA |
| Model | EFT-60 |
| Operating Frequency | 60 MHz |
| Magnet Type | AlNiCo Permanent Magnet |
| Sample Form | Solid and Liquid (with appropriate probes) |
| Resolution (1H) | < 0.5 Hz |
| Sensitivity (1H) | < 0.001 mmol/L |
| Nuclei Supported | ¹H, ¹³C, ¹⁹F, ³¹P, ²³Na, ⁵⁹Co, ²⁹Si |
| Cryogen-Free Operation | Yes |
| Compliance | ASTM E2821, ISO/IEC 17025 (when operated under GLP conditions), FDA 21 CFR Part 11–ready software architecture |
| Brand | Anasazi |
|---|---|
| Origin | USA |
| Model | EFT-60 / EFT-90 |
| Instrument Type | Benchtop High-Field NMR Spectrometer |
| Operating Frequency | 60 MHz / 90 MHz (¹H) |
| Sample Type | Liquid Solutions |
| Resolution | < 0.5 Hz (full width at half maximum, FWHM, for 1% ethylbenzene in CDCl₃) |
| Sensitivity | ≤ 0.001 mmol/L (for ¹H, single-scan, standard 5 mm tube) |
| Magnet System | AlNiCo permanent magnet with active temperature stabilization |
| Nuclei Supported | ¹H, ¹³C, ¹⁹F, ³¹P, ²³Na, ⁵⁹Co, ²⁹Si, and other quadrupolar/nuclear spin-½ nuclei |
| Software Platform | EFT-NMR v5.x with pulse sequence library and GLP-compliant audit trail |
| Compliance | Designed to support ISO/IEC 17025, ASTM E2823, and USP <724> method validation workflows |
| Brand | Anasazi |
|---|---|
| Origin | USA |
| Model | EFT-60, EFT-90 |
| Operating Frequency | 60 MHz / 90 MHz |
| Sample Type | Liquid |
| Measurement Principle | Pulsed Fourier Transform NMR |
| Magnet Type | AlNiCo Permanent Magnet |
| ¹H Resolution | < 0.5 Hz |
| Sensitivity | < 0.001 mmol/L (for ¹H, standard sample) |
| Supported Nuclei | ¹H, ¹³C, ¹⁹F, ³¹P, ²³Na, ⁵⁹Co, ²⁹Si, and other quadrupolar/low-γ nuclei |
| Software Platform | EFT-NMR Console v4.x |
| Compliance | ASTM E2857, ISO/IEC 17025 (method validation support), GLP-ready audit trail logging |
| Brand | Anasazi |
|---|---|
| Origin | USA |
| Model | EFT-60, EFT-90 |
| Operating Frequency | 60 MHz / 90 MHz |
| Sample Type | Liquid |
| Measurement Principle | Pulsed Fourier Transform NMR |
| Magnet Type | AlNiCo Permanent Magnet |
| Resolution (1H) | <0.5 Hz |
| Sensitivity | <0.001 mmol/L |
| Nuclei Supported | ¹H, ¹³C, ¹⁹F, ³¹P, ²³Na, ⁵⁹Co, ²⁹Si, and other quadrupolar/nuclear spin-½ nuclei |
| Compliance | ASTM E2874, ISO/IEC 17025-compatible operation, GLP-ready data audit trail |
| Brand | Anasazi |
|---|---|
| Origin | USA |
| Model | EFT-90 |
| Operating Frequency | 90 MHz |
| Sample Type | Solid & Liquid (Broadband) |
| Magnet Type | AlNiCo Permanent Magnet |
| Resolution | < 0.5 Hz (at 90 MHz, 1H, in DMSO-d6) |
| Sensitivity | < 0.001 mmol/L (for 1H, typical small-molecule sample) |
| Cryogen-Free Operation | Yes (No Liquid Helium or Liquid Nitrogen Required) |
| Compliance | ASTM E2831-18 (Standard Guide for NMR Spectroscopy Data Reporting), ISO/IEC 17025:2017 (for lab accreditation readiness), GLP/GMP-compatible data audit trail via software |
| Brand | Anasazi |
|---|---|
| Origin | USA |
| Model | EFT-90 |
| Operating Frequency | 90 MHz |
| Sample Type | Solid & Liquid (with appropriate probes) |
| Magnet Type | AlNiCo permanent magnet |
| Resolution | < 0.5 Hz (for 1H at 90 MHz) |
| Sensitivity | < 0.001 mmol/L (for 1H) |
| Cooling | Zero-boil-off, helium-free operation |
| Compliance | Designed for GLP-compliant academic and industrial R&D environments |
| Software | EFT-NMR v5.x with full pulse sequence library and audit trail capability |
| Brand | Anasys |
|---|---|
| Origin | USA |
| Model | nanoIR2-FS |
| Instrument Type | Laboratory Benchtop System |
| Core Principle | Photothermal Induced Resonance (PTIR) Coupled with Atomic Force Microscopy (AFM-IR) |
| Spectral Range | 1000–4000 cm⁻¹ (Standard Tunable Quantum Cascade Laser Source) |
| Spatial Resolution | <10 nm |
| Spectral Acquisition Speed | <3 s per spectrum |
| Data Sampling Interval | Adjustable down to 0.25 cm⁻¹ (FT-based spectral reconstruction) |
| Sample Mode | Ambient or Controlled Environment (N₂-purged optional) |
| Compatible Chemometrics Software | Anasys IR-Spectra™ (with NIST-compatible spectral libraries, ASTM E1421-22 compliant preprocessing) |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Alioth-π |
| Price Range | USD 4,200 – 5,600 (FOB) |
| Detection Limit (Pb in aqueous matrix) | <0.3 mg/L |
| Detection Limit (Cd in aqueous matrix) | <0.5 mg/L |
| Measurement Time | 60 s per analysis |
| Detector Resolution | ≤145 eV (Mn Kα) |
| X-ray Tube | Transmission-target microfocus tube |
| Optical Path | Optimized 3D ultra-short path (sample–tube–detector) with multilayer scatter suppression coating |
| Camera | Integrated 1-MP visible-light imager with real-time video capture |
| Enclosure Rating | IP67-equivalent dual-layer liquid ingress protection |
| Housing Material | Aerospace-grade Al-Mg alloy |
| Software Algorithm | Holographic Fundamental Parameters (FP) quantification engine |
| Operating Mode | PC-controlled or standalone tablet interface |
| Warm-up Time | <3 s |
| Power Supply | Rechargeable Li-ion battery (8+ hrs continuous operation) |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | DUBHE-1610 |
| Detection Limit (LLD) | 0.4 ppm (S) |
| Measurement Range | 0.4 ppm – 5 wt% |
| Analysis Time | 60–300 s |
| Repeatability | ≤0.2 ppm (at 2 ppm S), ≤0.5 ppm (at 10 ppm S), ≤2.5 ppm (at 50 ppm S) |
| Excitation Line | Cr Kα (5.41 keV) |
| Optical Configuration | Dual Polycapillary Focusing Monochromator + Full-Focus Bent Crystal Analyzer |
| Sample Preparation | ESP (Easy Sample Prepare) System |
| Operating Mode | Benchtop, Air-path, No Gas or Solvent Consumption |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | DUBHE-1710 |
| Detection Limit (Cl) | 0.1 ppm |
| Measurement Range | 0.1 ppm – 5 wt% |
| Analysis Time | 60–300 s |
| Repeatability | ≤0.2 ppm (at 1 ppm Cl), ≤0.5 ppm (at 5 ppm Cl), ≤2.5 ppm (at 50 ppm Cl) |
| Sample Prep Time | <10 s |
| Operating Warm-up | ≤10 min |
| Cost per Sample | <USD 0.55 (excl. labor) |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | MEGREZ-A |
| Excitation | Dual X-ray tube sources with polycapillary-focusing monochromators |
| Detection Principle | Energy-dispersive X-ray fluorescence (ED-XRF) with monochromatic excitation |
| Elemental Range | Z ≥ 5 (Boron and heavier elements) |
| Detection Limit (Heavy Metals) | As low as 0.05 mg/kg (matrix-dependent) |
| Quantification Method | Fast fundamental parameters (FP) algorithm with minimal or zero calibration standards |
| Compliance | Designed for ISO 8258, ASTM E1621, and GB/T 30091–2013 compliant workflows |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | MERAK-CEMII |
| Price Range | USD 70,000 – 140,000 |
| Compliance | GB/T 176–2008 |
| Elements Analyzed | Na, Mg, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn |
| Detection Principle | Wavelength-Dispersive XRF (WDXRF) with High-Flux Doubly Curved Crystal Spectrometer (HF DCCS) and Secondary Target Excitation |
| Sample Form | Solid powders (pressed pellets or fused beads) |
| Vacuum/Atmosphere | Ambient air operation (no vacuum pump or He purge required) |
| Cooling | Peltier-cooled detector (no liquid nitrogen) |
| Stability | Ready for measurement within 3 minutes after power-on |