| Brand | Anjie |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Domestic |
| Model | AJ-510 |
| Quotation | Upon Request |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 2.0 nm |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ±0.1 nm |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Model | AS-3016 |
| Sample Capacity | 160 × 2 mL vials |
| Minimum Injection Volume | 0.1 µL |
| Standard Loop Volume | 10 µL |
| Positioning Accuracy | ±0.3 mm |
| Motion Architecture | Vertical tower with optional expansion tray |
| Needle Wash Cycles | 99 internal rinses per injection |
| Replicate Injections per Vial | up to 99 |
| Injection Speed | configurable down to 0.1 s per injection |
| Injection Depth Range | –2 to 35 mm |
| Sample Tray Encoding | absolute-position optical encoder |
| Communication Protocols | Modbus RTU, USB 2.0, TTL I/O (compatible with major GC vendors) |
| Operating Temperature | –20 °C to 50 °C |
| Storage Temperature | –40 °C to 70 °C |
| Relative Humidity (operating) | 10–90% RH non-condensing |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AS-3016B |
| Instrument Type | Multifunctional Autosampler |
| Maximum Sample Capacity | 160 positions |
| Minimum Injection Volume | 0.1 µL |
| Quantitative Loop Volumes | 0.5, 1, 5, 10, 25, 50, and 500 µL |
| Positioning Accuracy | ≤ 0.3 mm |
| Motion System | XYZ three-axis robotic arm |
| Needle Wash Cycles | up to 99 |
| Re-injection Repetitions | up to 99 |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Model | AS-3016C |
| Instrument Type | GC Autosampler |
| Max Sample Capacity | 24–160 positions (standard 24, expandable to 160) |
| Minimum Injection Volume | 0.1 µL |
| Quantitative Loop Volume Range | 0.5–500 µL (user-selectable) |
| Positioning Accuracy | ±0.1 mm |
| Motion Architecture | Vertical Tower (Z-axis linear actuation) |
| Needle Wash | Internal & External Wall Rinse, Unlimited Cycles |
| Repeat Injection Capability | Unlimited (user-configurable) |
| Syringe Options | 1, 5, 10, 25, 50, 100, 250, 500 µL |
| Solvent Bottle Positions | 2 (expandable to 11) |
| Waste Bottle Positions | 1 (expandable to 5) |
| Per-Vial Injection Count | 1–99 |
| Maximum Time Interval Between Injections | 999 min |
| Viscosity Delay | 0–60 s |
| Pre-/Post-Insertion Dwell Time | 0–120 s |
| Needle Penetration Speed | Fast / Slow / Custom |
| Aspiration/Dispense Speed | Fast / Slow / Custom |
| Injection Modes | Conventional, Continuous, Sample+L1, Sample+L1+L2, PTV-compatible |
| Control Interface | TTL-triggered interval control, GC signal reverse-triggering, USB 2.0, Modbus RTU over RS-485 |
| Dual-Tower Injection Time Reproducibility | < 1 ms |
| Barcode Scanning Support | Yes |
| Sample Temperature Control | Optional integrated cooling/heating module |
| Operating Temperature | −20 °C to +50 °C |
| Storage Temperature | −40 °C to +70 °C |
| Operating Humidity | 10–90% RH (non-condensing) |
| Storage Humidity | 5–90% RH |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Model | AS-3117 |
| Sample Capacity | 156-position 2 mL vial tray + 15-position auxiliary tray |
| Minimum Injection Volume | 0.01 µL |
| Quantitative Loop Volume | 10 µL |
| Positioning Accuracy | ≤ 0.3 mm |
| Motion Mechanism | Turret-based |
| Needle Wash | Internal Wall Rinse |
| Repeat Injection Cycles | Up to 99 |
| Operating Temperature Range | −20 °C to 50 °C (operational), −40 °C to 70 °C (storage) |
| Relative Humidity Range | 10–90% RH (operational), 5–90% RH (storage) |
| Communication Protocol | Modbus RTU |
| I/O Interface | Configurable digital I/O for GC synchronization |
| Control Modes | Interval-triggered, signal-triggered (TTL/relay), and full PC-based remote control |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AS-3117B |
| Instrument Type | GC Autosampler |
| Max Sample Capacity | 20 positions (expandable to 156) |
| Minimum Injection Volume | 0.1 µL |
| Positioning Accuracy | < 0.1 mm |
| Motion Mechanism | Turret-based |
| Needle Wash Mode | Selectable (pre- and/or post-injection) |
| Repeat Injection Count | Up to 99 cycles per sample |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GAS-3519 |
| Instrument Type | Gas Chromatography Autosampler |
| Max Sample Capacity | 88 positions |
| Minimum Sample Volume | 1 mL |
| Quantitative Loop Volumes | 1 mL / 2 mL / 3 mL |
| Positioning Accuracy | <0.1 mm |
| Sampling Mechanism | Quantitative Loop Injection |
| Needle/Line Cleaning | Fully Automated |
| Repeat Injection Cycles per Sample | Up to 99 |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GAS-3519-XS |
| Instrument Type | Gas Chromatography (GC) Gas Bag Autosampler |
| Maximum Sample Volume | 5 mL |
| Minimum Sample Volume | 1 mL |
| Quantitative Loop Volume Range | 0.05–5 mL |
| Positioning Accuracy | RSD < 0.5% for total hydrocarbon and methane peak areas across 10 consecutive injections |
| Control Method | PC-based host software control |
| Needle/Line Cleaning | Integrated pneumatic line purge with inert gas |
| Repeat Injection Count | 1–99 times per sample |
| Sample Tray Capacity | 11 / 28 / 40 positions (expandable to 88) |
| Quantitative Loop & Line Heating Range | Ambient to 150 °C |
| Sample & Standard Dilution Ratio | Up to 1:200 (customizable) |
| Sampling Pump | Max flow 6 L/min |
| Sampling Time Parameters | Max draw time 99 s, max equilibration time 99 s, max purge time 600 s |
| Tubing Material | PTFE |
| Valve Actuator | PEEK body with PI (polyimide) rotor |
| Data Interfaces | USB, Ethernet (RJ45), RS-232 |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Model | GAS-3529A-16 |
| Instrument Type | Gas Chromatography Autosampler |
| Max Sampling Rate | 6 L/min |
| Ultimate Vacuum | −55 kPa |
| Minimum Sample Volume | 1 mL (configurable to 2 mL or 3 mL) |
| Quantitative Loop Volume | 1 mL / 2 mL / 3 mL (user-selectable) |
| Positioning Accuracy | RSD < 1% for total hydrocarbon and methane peak areas across 10 consecutive injections |
| Sample Capacity | 16 positions (base unit) |
| Dimensions (L×W×H) | 40 × 50 × 37 cm (height increases by 15 cm per added module) |
| Cleaning | Automated syringe needle path flush + quantitative loop purge + gas bag rinse |
| Valve Actuation | PEEK body with PI (polyimide) rotor |
| Tubing Material | PTFE and PEEK only |
| Data Interfaces | USB, Ethernet (RJ45), RS-232 |
| Compliance | Meets GB/T 33642–2017 (Chinese national standard for gas sampling systems in GC applications) |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GAS-3539 |
| Instrument Type | Multifunctional Gas Autosampler |
| Max Sample Positions | 88 |
| Min Sample Positions | 16 |
| Quantitative Loop Volumes | 1 mL, 2 mL, 3 mL (selectable) |
| Positioning Accuracy | RSD <0.5% for total hydrocarbon and methane peak areas across 10 consecutive injections |
| Control Interface | PC-based upper-computer software |
| Needle & Loop Cleaning | Automated in-line cleaning of sampling lines, quantitative loops, gas bags, and sample pathways during GC coupling |
| Repeat Injection Capability | Unlimited cycles per sample |
| Operating Temperature Range | −20 °C to 50 °C |
| Storage Temperature Range | −40 °C to 70 °C |
| Humidity Range (Operating) | 10–90% RH |
| Humidity Range (Storage) | 5–90% RH |
| Syringe Capacity | 100 mL |
| Gas Bag Capacity | 500 mL or 1 L |
| Minimum Injection Volume | 50 µL (loop-dependent) |
| Maximum Injection Volume | 5 mL (loop-dependent) |
| Max Purge Time | 600 s |
| Max Draw Time | 99 s |
| Max Equilibration Time | 99 s |
| Max Interval Between Injections | 999 min |
| Quantitative Loop Heating Range | Ambient to 150 °C |
| Sample Pathway Heating Range | Ambient to 150 °C |
| Calibration Standard Points | Up to 8 programmable concentration levels |
| Cleaning Cycles per Step | 1–15 |
| Sampling Pump Flow Rate | Up to 6 L/min |
| Ultimate Vacuum | −55 kPa |
| Data Interfaces | USB, Ethernet (RJ45), RS-232 |
| Dimensions (L×W×H) | 900 × 600 × 900 mm |
| Tubing Material | Silanized stainless steel |
| Valve Body | PEEK |
| Valve Core | PI (Polyimide) |
| Sample Port Flexibility | Dual-mode — gas bag or syringe injection per port |
| High-Concentration Detection Logic | Auto-halt + GC oven ramp initiation upon detection of saturation-level analyte signals |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LAS-3622 |
| Instrument Type | HPLC Autosampler |
| Max Sample Capacity | 200 positions |
| Minimum Injection Volume | 0.1 µL–2 mL |
| Loop Volumes | 50 µL, 100 µL, 250 µL, 1000 µL |
| Positioning Accuracy | <1% RSD at 1 µL, <0.5% RSD at 5 µL, <0.3% RSD at 10 µL |
| Sampling Mechanism | Loop-based injection |
| Needle Wash Modes | Automated line purge, bubble removal, pre-injection wash, post-injection wash |
| Repeat Injection Capability | Unlimited cycles per sample |
| Brand | ANPRO |
|---|---|
| Model | APN-II |
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Wavelength Range | 185–950 nm |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | ≤±0.05 nm |
| Detector | CCD Array |
| Optical System | Dual-Wavelength Scanning with Hybrid Diffraction Grating |
| Automation Level | Fully Automatic Wavelength Selection & Sample Handling |
| Sample Throughput | Up to 12 Cuvettes (11 Simultaneous Samples + Reference) |
| Display | 10.1-inch Capacitive Touch LCD with VGA/HDMI Output |
| Computing Platform | Embedded Industrial PC (Quad-Core CPU, 4 GB RAM, Windows OS) |
| Data Storage | 500 GB SSD |
| Connectivity | Dual USB 2.0, RS232, Ethernet, Wi-Fi, VGA, Audio Out |
| Compliance | Designed for GLP-compliant food safety laboratories |
| Brand | Anritsu |
|---|---|
| Origin | Japan |
| Model | MS9740B |
| Wavelength Range | 600–1750 nm |
| Wavelength Accuracy | ±20 pm (1520–1620 nm, RBW 0.03–0.2 nm) / ±100 pm (1520–1620 nm, RBW 0.5/1.0 nm) |
| Wavelength Resolution (RBW) | 0.03 / 0.05 / 0.07 / 0.1 / 0.2 / 0.5 / 1.0 nm (3 dB bandwidth) |
| Dynamic Range | ≥60 dB at 0.4 nm offset from peak |
| Minimum RBW | 30 pm |
| Scan Speed | ≤0.2 s for 5 nm span (RBW 0.1 nm, VBW 10 kHz) |
| Max Input Power | +23 dBm (with optical attenuator enabled) |
| Fiber Compatibility | SMF-28 (9/125 µm, ITU-T G.652), 50/125 µm GI fiber |
| Connector Options | Interchangeable FC, SC, ST, DIN, LC |
| Storage Capacity | Up to 1,000 files or 10,000 spectra |
| Interfaces | Ethernet (standard), GPIB (optional) |
| Dimensions | 426 × 177 × 350 mm (W×H×D, excluding protrusions) |
| Weight | ≤15.0 kg (excluding options) |
| Power Consumption | ≤75 VA |
| Brand | Antec |
|---|---|
| Origin | Netherlands |
| Model | ALEXYS |
| Instrument Type | Conventional High-Performance Liquid Chromatograph with Electrochemical Detection |
| Flow Rate Range | 0.001–10 mL/min |
| Maximum Pressure | 70 MPa |
| Autosampler Capacity | 192 positions |
| Injection Volume Range | 1–20 µL |
| Column Oven Temperature Range | Ambient +7 °C to 60 °C |
| Detector Output Range | −2500 mV to +2500 mV |
| Data Acquisition Frequency | 1–100 Hz |
| Brand | Antec |
|---|---|
| Origin | Netherlands |
| Model | DECADE Elite |
| Detector Type | Electrochemical Detector (ECD) |
| Compatible Systems | HPLC, UHPLC, EC-MS Coupling |
| Operating Modes | DC, Pulsed, Scanning |
| Signal Processing | Advanced Digital Filter (ADF) |
| Flow Cell Volume Range | 0–300 nL (continuously adjustable) |
| Cell Design | Central Jet-Wall Electrode Configuration |
| Temperature Control | Integrated Faraday-Shielded Thermostatic Chamber |
| Compliance | Designed for GLP/GMP environments |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DECADE II |
| Pricing | Upon Request |
| Detector Type | Electrochemical Detector (ED) |
| Brand | Antec |
|---|---|
| Origin | Netherlands |
| Model | DECADE II |
| Detector Type | Electrochemical Detector (ECD) |
| Operating Modes | DC, Pulse, and Scan |
| Digital Filter Range | 0.5–0.001 Hz (1–2–5 decade steps) |
| Potential Range | ±2.00 V |
| Faraday Column Oven Dimensions | H 37 cm |
| Temperature Range | Ambient +7 °C to 45 °C |
| Temp. Stability | ±0.1 °C |
| Flow Cell Types | Central Jet Wall-Flow Cell & Conventional Thin-Layer Cell |
| Electrode Configurations | SCC, DCC, TCC, QCC |
| Brand | Antec |
|---|---|
| Origin | Netherlands |
| Model | DECADE II SDC |
| Detector Type | Electrochemical Detector (ECD) |
| Operating Modes | DC Amperometry with Advanced Digital Filtering (ADF) |
| Filter Frequency Range | 0.5–0.001 Hz (decade steps: 1, 2, 5) |
| Potential Range | ±2.00 V |
| Faraday Column Oven Dimensions | Height 37 cm |
| Temperature Range | Ambient +7 °C to 45 °C |
| Temperature Stability | ±0.1 °C |
| Flow Cell Types | Central-jet wall-type electrode (compatible with standard & capillary HPLC columns) and conventional thin-layer electrode |
| Electrode Configurability | Interchangeable working and reference electrodes (e.g., glassy carbon, gold, platinum, Ag/AgCl) |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Conventional HPLC System |
| Model | Anters-1200R |
| Flow Rate Range | 0.001–5 mL/min |
| Maximum Pressure | 40 MPa |
| Autosampler Capacity | Standard 144 × 2 mL vials |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | −20 °C to 100 °C |
| Refractive Index (RI) Detection Range | 1.00–1.75 RIU |
| Data Acquisition Rate | 100 Hz |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | Aquatrac-V |
| Measurement Principle | Calcium Hydride Reaction (DIN EN ISO 15512:2019) |
| Resolution | 0.0001% H₂O |
| Application | Residual Moisture Analysis in Thermoplastics & MFR Sample Preparation |
| Compliance | Fully compliant with DIN EN ISO 15512:2019 for selective water determination in plastics |
| Software | Aquatrac Control Software with LIMS/ERP integration capability |
| Data Integrity | Audit trail, user access levels, electronic signatures (21 CFR Part 11 ready) |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | MT-CA / Aquatrac-V |
| Measurement Principle | Gravimetric (MT-CA), Calcium Hydride Reaction + Vacuum Pressure Monitoring (Aquatrac-V) |
| Moisture Range | 0.1% to 99.9% (MT-CA) |
| Compliance | DIN EN ISO 15512:2019, ICC 113, ISO 712, EC Tobacco Specifications |
| Software | MetaBridge v3.x (FDA 21 CFR Part 11 compliant audit trail, LIMS/ERP integration, GLP/GMP workflow support) |
| Sample Throughput | Up to 10 samples per run (MT-CA) |
| Standards Support | Preloaded methods for flour, tobacco, polymers, pasta, coffee, building materials |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Cora 100 |
| Instrument Type | Handheld Raman Spectrometer |
| Spectral Range | 400–2300 cm⁻¹ |
| Spectral Resolution | ≤10 cm⁻¹ |
| Spatial Resolution | <1 mm |
| Minimum Wavenumber | 400 cm⁻¹ |
| Spectral Reproducibility | High repeatability across repeated measurements on identical samples |
| Laser Wavelength | 785 nm |
| Laser Power at Sample | >215 mW (output: 300 mW) |
| Detector | Linear CCD Array |
| Display | 3.5″ Transmissive TFT with LED Backlight |
| Operating System | Embedded Linux |
| Data Format | Text (.txt, .csv, .spc) |
| Interface | USB 2.0 |
| Battery | Rechargeable Li-ion (≈60 scans per charge, non-user-replaceable) |
| Dimensions | 15.8 × 10.1 × 2.9 cm |
| Weight | 650 g |
| IP Rating | IP67 |
| Operating Temperature | −20 °C to +40 °C |
| Storage Temperature | −30 °C to +50 °C |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Product Type | Portable/Handheld Raman Spectrometer |
| Model | Cora 100 |
| Spectral Range | 400–2300 cm⁻¹ |
| Spectral Resolution | <10 cm⁻¹ |
| Spatial Resolution | <1 mm |
| Laser Wavelength | 785 nm |
| Laser Power at Sample | >215 mW |
| Detector | Linear CCD Array |
| Display | Transflective TFT with LED Backlight |
| Operating Temperature | −20 °C to +40 °C |
| IP Rating | IP67 |
| Dimensions | 15.8 cm × 10.1 cm × 2.9 cm |
| Weight | 650 g |
| Battery Life | Up to 60 scans per charge |
| Data Format | Text (.txt) |
| Connectivity | USB 2.0 |
| OS | Embedded Linux |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Product Type | Portable/Desktop Raman Spectrometer |
| Model | Cora 5001 |
| Spectral Range | 100–3500 cm⁻¹ |
| Spectral Resolution | 6–9 cm⁻¹ |
| Spatial Resolution | 1 µm (lateral), 1 µm (axial) |
| Minimum Wavenumber | 100 cm⁻¹ |
| Spectral Reproducibility | < 0.5 cm⁻¹ |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Cora 5001 |
| Detector Type | CMOS |
| Laser Class | Class 1 |
| Safety Interlock | Integrated shutter-based activation (laser only active when sample chamber is fully closed) |
| Optical Architecture | Monolithic aluminum optical bench, no moving parts |
| Focus Mechanism | Motorized auto-focus with real-time signal optimization |
| Excitation Options | Dual-wavelength “Dual-Core Raman” configuration available (e.g., 785 nm and 1064 nm) |
| Sample Compatibility | Solids (tablets, films, crystals), liquids (in vials of circular/square/rectangular cross-section), powders, pastes |
| Accessories | Magnetic sample holders, universal vial adapters, solid-sample stage with quick-lock positioning |
| Compliance | IEC 60825-1:2014 (Class 1 laser product), CE marked, RoHS compliant |
| Software | Cora Suite v3.x with spectral library matching (≥10,000 reference spectra), GLP-compliant audit trail, FDA 21 CFR Part 11 optional module |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Cora 5001 Direct |
| Instrument Type | In-line Raman Spectrometer |
| Spectral Range | 100–3500 cm⁻¹ (wavelength-dependent) |
| Laser Classes | Class 1 (Direct model) |
| Excitation Wavelengths | 532 nm, 785 nm, 1064 nm (single- or dual-wavelength configurations) |
| Spectral Resolution (per ASTM E2529) | 6–17 cm⁻¹ (wavelength-dependent) |
| Detector | 2048-pixel CCD (532/785 nm), 256-pixel InGaAs (1064 nm) |
| Auto-focus | Yes |
| Software | Anton Paar Spectroscopy Suite (with audit trail, electronic signatures, SQL database, GLP/GMP support) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Cora 5001 Fiber |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 100–3500 cm⁻¹ |
| Spectral Resolution | 6–9 cm⁻¹ |
| Spatial Resolution | 1 µm (lateral), 1 µm (axial) |
| Minimum Wavenumber | 100 cm⁻¹ |
| Spectral Reproducibility | < 0.5 cm⁻¹ |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Lyza 3000 |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 350–7500 cm⁻¹ |
| Spectral Resolution | <1.4 cm⁻¹ (0.7 cm⁻¹ optional) |
| Scan Speed | <30 seconds per spectrum |
| Signal-to-Noise Ratio (S/N) | 55,000:1 (at 4 cm⁻¹, 16 scans, DTGS detector) |
| Wavenumber Accuracy | <0.05 cm⁻¹ |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 550–6000 cm⁻¹ |
| Resolution | 8 cm⁻¹ |
| Scan Speed | 48 scans per 35 seconds |
| Signal-to-Noise Ratio | 46,980:1 |
| ATR Prism | 12-reflection diamond crystal |
| Temperature Control Accuracy | ±0.03 °C |
| Interface | 10.1-inch capacitive touchscreen |
| Automation Compatibility | Xsample 520 (24-position autosampler optional) |
| Data Export | LIMS-compatible, PDF/CSV report generation |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Lyza 7000 |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 350–7500 cm⁻¹ |
| Spectral Resolution | <1.4 cm⁻¹ |
| Scan Speed | <30 s per spectrum |
| Signal-to-Noise Ratio | 55,000:1 (at 4 cm⁻¹, 32 scans) |
| Wavenumber Accuracy | <0.05 cm⁻¹ |