Chemical Analysis Instruments
Filter
Showing 691–720 of 10556 results
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | MERAK-LEII |
| Detection Range | Na–Ti (extendable to C, N, O, F) |
| Light Element LLDs | S ≤ 0.2 ppm, Cl ≤ 0.1 ppm, Si ≤ 0.8 ppm |
| Excitation | Monochromatized Wavelength-Selective X-ray Beam via Focusing Polycapillary Optics |
| Optical Architecture | Fixed X-Ray Path System (XFS) |
| Sample Form | Solid, Liquid, or Powder in Disposable Cups/Membranes |
| Compliance | Designed for ASTM D2622, D4294, D7039, ISO 8754, IP 287, and USP <233> elemental impurity testing workflows |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | MERAK-MINI |
| Detection Limit (S) | 0.5 ppm (300 s) |
| Detection Limit (Cl) | 0.3 ppm (300 s) |
| Quantification Range | 0.5 ppm – 5% |
| Analysis Time | 60–300 s |
| Repeatability | RSD ≤ 3% @ 10 ppm S, RSD ≤ 1.5% @ 1000 ppm S |
| Dimensions | 350 mm × 230 mm × 370 mm |
| Weight | 12.5 kg |
| Power Consumption | 80 W |
| Operating Temperature | 5–40 °C |
| Battery Life | >4 h |
| Compliance | ASTM D7039, ASTM D7536, ISO 20884, ISO 15597 |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | MERAK-SC |
| Excitation | Monochromatic Focused X-ray (Johansson-type DCC crystal) |
| Detection | Ultra-thin Graphene-window Silicon Drift Detector (SDD) |
| Elemental Range | F–Cl (light elements), K–Zn (transition metals) |
| LOD (F) | 0.15 wt% (300 s, aqueous matrix) |
| LOD (Al–Cl) | 0.0002–0.005 wt% (300 s) |
| Sample Types | Liquids, powders, solids |
| Geometry | Top-illumination |
| Sample Rotation | Motorized, software-controlled |
| Temperature Control | 24 ± 0.3 °C |
| Analysis Time | 30–300 s per sample |
| Stability | < ±3% intensity drift over 24 h |
| Quantification Engine | Fast FP 2.0 fundamental parameters software |
| Compliance | Designed for ISO 8258 (control charts), ASTM E1621 (ED-XRF for cement), USP <233> (elemental impurities), and GLP/GMP-aligned data integrity workflows |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MERAK-TINY |
| Pricing | Upon Request |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | PHECDA-ECO |
| Element Range | Mg–U |
| LOD (soil matrix, 600 s) | Cd: 0.06 mg/kg, Pb: 0.4 mg/kg, Cr: 1.0 mg/kg |
| Repeatability (Cd, soil) | ≤0.3 mg/kg, RSD <15% |
| Sample Types | Solid, liquid, powder, viscous |
| Detector | High-performance Silicon Drift Detector (SDD) |
| Excitation | Monochromatic focused excitation via doubly curved crystal (DCC) |
| Method | Single-wavelength excitation + energy-dispersive detection |
| Software | Fast FP® quantitative engine with matrix-adaptive modeling |
| Optional Preconcentration | Heavy Metal Enrichment Tape (HMET®) for aqueous samples (LOD: 1–3 µg/L) |
| Weight | 7.5 kg |
| Dimensions | 370 × 290 × 190 mm |
| Operation | Ambient air, no vacuum/gas required |
| Sample Interface | Motorized sample rotation stage |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | PHECDA-FVS |
| Instrument Type | Micro-Zone ED-XRF |
| Elemental Range | Mg to U |
| Detection Limits (Large Spot Mode, Light Matrix) | S: 10 mg/kg, Fe: 2 mg/kg, Pb: 1.0 mg/kg, Cd: 0.3 mg/kg |
| Minimum Focal Spot | φ200 µm |
| Spot Size Options | Software-Selectable Apertures (φ200–φ5000 µm, Rectangular Beam Optional) |
| X-Y Stage Range | ±10 mm |
| Step Resolution | 10 µm |
| Camera Magnification | 10×–100× |
| Sample Chamber Dimensions | 280 × 230 × 70 mm (L×W×H) |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | PHECDA-HE & PHECDA-HES |
| Detection Limit (soil matrix, 300 s) | Cd: 0.06 mg/kg, Pb: 0.4 mg/kg, Cr: 1.0 mg/kg |
| Repeatability (Cd, soil) | RSD < 15% at 0.3 mg/kg |
| Elemental Range | Mg–U |
| Sample Types | Solid, liquid, powder, viscous |
| Detector | High-performance Silicon Drift Detector (SDD) |
| Excitation Principle | Monochromatic focused excitation via doubly curved crystal (DCC) |
| Software | Fast FP® 2.0 quantitative engine |
| Auto-sampler | 30+ positions (PHECDA-HES) |
| HMET® integration for aqueous samples (detection limit | 1–3 µg/L) |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | PHECDA-PRO |
| Excitation Principle | Monochromatic Focused Excitation (using doubly curved crystal monochromator) |
| Detection Principle | Energy-Dispersive XRF (ED-XRF) |
| Elemental Range | Mg–U |
| LOD (soil matrix, 600 s) | Cd: 0.06 mg/kg, Pb: 0.4 mg/kg, Cr: 1.0 mg/kg |
| Precision (RSD) | Cd <15% at 0.3 mg/kg (soil, 600 s) |
| Sample Types | Solids, powders, slurries, liquids (with HMET® membrane enrichment), filters (e.g., PM₂.₅), and viscous matrices |
| Detector | High-performance silicon drift detector (SDD) with optimized active area and energy resolution |
| Software | Fast FP® quantitative engine (fundamental parameters-based, matrix-adaptive, standard-free or minimal-standard calibration) |
| Optional Enhancement | Heavy Metal Enrichment Technology (HMET®) for aqueous samples (LOD: 1–3 µg/L) |
| Portability | 8.7 kg |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | DV-420A-BV |
| Spectral Range | 300–1000 nm |
| Pixel Array | 1024 × 256 |
| Pixel Size | 26 × 26 µm |
| Imaging Area | 26.6 × 6.7 mm |
| Peak Quantum Efficiency | 95% |
| Maximum Cooling Temperature | −75 °C |
| Full Well Capacity (typ.) | 510 k e⁻ |
| Register Capacity (typ.) | 1 M e⁻ |
| Maximum Spectral Acquisition Rate | 75 spectra/s |
| Read Noise (typ.) | 4 e⁻ |
| Readout Speeds | 0.1 / 0.05 / 0.033 MHz |
| ADC Resolution | 16-bit |
| Dark Current (@−70 °C) | 0.002 e⁻/pixel/s |
| Interface | USB 2.0 |
| Vacuum Packaging | Andor UltraVac™ |
| Cleanroom Assembly | ISO Class 4 (10,000) |
| Compliance | CE, RoHS |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model Series | Kymera 193i, Kymera 328i, Shamrock 500i, Shamrock 750, Mechelle 5000 |
| Spectral Resolution | 0.02 nm (Shamrock 750) |
| Imaging Resolution | 6000 (Mechelle 5000) |
| Optical Design | Czerny-Turner or Echelle |
| Configuration | Filter-based spectroscopy |
| Platform Compatibility | Ground- and airborne deployment |
| Detector Interface | Dual-input/dual-output architecture |
| Focal Length Range | 193 mm to 750 mm |
| Aperture Range | f/3.6 to f/9.7 |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Mechelle 5000 |
| Wavelength Range | 200–975 nm |
| Optical Configuration | Fixed-grating, pre-aligned echelle spectrograph |
| Detector Integration | Integrated CCD/CMOS detector option |
| Cooling | Thermoelectric (TE) cooled detector |
| Purge Environment | N₂-purged optical path |
| Temperature Stabilization | Auto-temperature correction system |
| Mechanical Design | Compact, rigid monolithic housing |
| Moving Parts | None |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | Mechelle 5000 |
| Spectral Range | 200–975 nm |
| Optical Architecture | Fixed, pre-aligned echelle spectrograph with no moving parts |
| Detector Format | Integrated CCD or sCMOS detector (user-selectable) |
| Resolution | High-resolution echelle dispersion (R ≈ 20,000–40,000 depending on slit and detector configuration) |
| Wavelength Coverage | Simultaneous full-range acquisition without scanning |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | Shamrock 163i |
| Focal Length | 163 mm |
| f-number | f/3.6 |
| Optical Design | Czerny-Turner |
| Grating Compatibility | Interchangeable ruled and holographic gratings |
| Input Options | Adjustable slit (10–200 µm), fiber optic coupling (SMA905, FC/PC), free-space input |
| Detector Interface | Standard Andor camera mounting (C-mount, F-mount, or direct sensor integration) |
| Wavelength Range | UV-Vis-NIR (dependent on grating and detector choice) |
| Resolution | <0.1 nm (typical, with 1200 grooves/mm grating and 10 µm slit) |
| Stray Light Rejection | <1×10⁻⁴ |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Detector Types | PMT (185–900 nm), Si Photodiode (200–1100 nm), InGaAs (800–1900 nm), PbS (800–2900 nm), InSb (1–5.5 µm), MCT (2–12 µm) |
| Power Supply | High-Voltage PMT Driver |
| Data Acquisition | Single-Photon Counting Module & Analog Digitizer |
| Accessories | Sample Chambers, Filter Wheels, Fiber-Optic Coupling Kits |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | Solis |
| Operating Systems | Windows Vista/7/8/10 (32-bit & 64-bit) |
| Development Interfaces | C/C++, C#, VB6, LabVIEW, MATLAB, Linux-compatible SDK |
| Compatible Hardware | Andor CCD/EMCCD/sCMOS cameras, spectrographs, motorized stages, filter wheels, shutters |
| Integration Support | µ-Manager plugin architecture |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | SR-163 |
| Optical Design | Czerny-Turner |
| Focal Length | 163 mm |
| F/# | f/3.6 |
| Wavelength Range | 300–500 nm |
| Spectral Resolution | 0.08 nm @ 2400 grooves/mm, 300 nm |
| Wavelength Accuracy | ±0.25 nm |
| Wavelength Repeatability | ±0.05 nm |
| Stray Light | ≤0.3% T |
| Dispersion | 2.0 nm/mm (with specified grating) |
| Entrance Slit Options | Multiple fixed and adjustable slit widths |
| Grating Mount | Dual-grating turret (standard), up to 3 gratings optional |
| Detector Compatibility | Full integration with Andor CCD, ICCD, and EMCCD cameras |
| Imaging Plane Dimensions | 28 mm × 10 mm |
| Grating Size | 40 mm × 40 mm |
| Coupling Options | SMA fiber port, kinematic flange, motorized shutter, dynamic slit, silver-coated optics (SR-163-SIL variant) |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | SR-303i |
| Application Systems | Transmission & Reflectance Spectroscopy |
| Grating Turret | Triple-grating (motorized) |
| Spectral Resolution | 0.08 nm @ 2400 g/mm, 300 nm |
| Dispersion | 2.2 nm/mm |
| Wavelength Range | 303–800 nm |
| F-number | F/4 |
| Wavelength Accuracy | ±0.04 nm |
| Stray Light Rejection | ≤0.3% T (typical), <2.2×10⁻⁵ (peak-to-valley) |
| Focal Length | 303 mm |
| Image Plane Dimensions | 28 mm × 14 mm |
| Slit Width Range | Motorized dynamic slit, up to 12 mm |
| Weight | 20 kg |
| Dimensions (L×W×H) | 394 × 238 × 208 mm |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | SR-500i |
| Spectral Resolution | 0.05 nm |
| Wavelength Range | 180 nm – IR |
| Dispersion | 1.44 nm/mm |
| F/# | f/6.5 |
| Wavelength Accuracy | ±0.04 nm |
| Stray Light | 2.6 × 10⁻⁵ |
| Grating Configuration | Triple-grating turret |
| Focal Length | 500 mm |
| Entrance/Exit Ports | Up to 2 input and 2 output ports |
| Image Plane Dimensions | 28 mm × 14 mm |
| Physical Dimensions | 550 mm × 343 mm × 206.5 mm |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | SR-750 |
| Focal Length | 500 mm |
| F/# | F/9.7 |
| Wavelength Range | 300–500 nm |
| Spectral Resolution | 0.02 nm @ 2400 grooves/mm, 300 nm |
| Wavelength Accuracy | ±0.03 nm |
| Wavelength Repeatability | ±10 pm |
| Stray Light Suppression | ≤2.6×10⁻⁵ |
| Grating Size | 68 mm × 68 mm |
| Dispersion | 2.6 nm/mm (at 300 nm, 2400 g/mm) |
| Slit Input Options | 1 or 2 |
| Detector Output Ports | 1 or 2 CCD ports + optional slit output |
| 焦平面尺寸 | 28 mm × 14 mm |
| Grating Turret | 3-position, fully documented per unit |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | SR193i |
| Spectral Range | 200–1100 nm |
| F/# | 3.6 |
| Spectral Resolution | 0.21 nm @ 1200 g/mm, 500 nm |
| Dispersion | 2.6 nm/mm |
| Wavelength Accuracy | ±0.2 nm |
| Stray Light | 1.5 × 10⁻⁴ |
| Grating Configuration | Dual-grating turret with RFID-enabled auto-identification |
| Optical Design | Imaging-corrected with toroidal mirrors |
| Detector Interfaces | Dual-output ports for simultaneous UV–NIR CCD/EMCCD/ICCD and InGaAs array or single-point detectors |
| Optional Coating | Silver-coated optics for enhanced NIR/SWIR throughput |
| Interface | USB 2.0, plug-and-play |
| Software Integration | Micro-Manager SDK-compatible spectral acquisition and analysis suite |
| Brand | Andor |
|---|---|
| Origin | Israel |
| Model | SR193i |
| Application Systems | Transmission & Reflection Spectroscopy |
| Grating Configuration | Dual-grating turret |
| Spectral Resolution | 0.21 nm @ 1200 g/mm, 500 nm |
| Dispersion | 2.6 nm/mm |
| Wavelength Range | 200–1100 nm |
| F/# | 3.6 |
| Wavelength Accuracy | ±0.2 nm |
| Stray Light | 1.5 × 10⁻⁴ |
| Focal Length | 193 mm |
| Imaging Optics | Aplanatic toroidal mirrors |
| Spectral Reproducibility | ±75 pm |
| Grating Turret | RFID-enabled, quick-release dual-grating turret |
| Detector Compatibility | Dual-output port for simultaneous CCD/EMCCD or sCMOS detector coupling |
| Slit Output Option | Configurable monochromator mode |
| Microscope Integration | C-mount and SM1-threaded interfaces compliant |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | SR303i |
| Spectral Range | 303–800 nm |
| F/# | F/4 |
| Wavelength Accuracy | ±0.04 nm |
| Wavelength Repeatability | ±0.004 nm |
| Spectral Resolution | 0.08 nm @ 2400 grooves/mm, 300 nm |
| Dispersion | 2.2 nm/mm |
| Stray Light Suppression | ≤2.2×10⁻⁵ |
| Grating Configuration | Triple-grating turret |
| Input/Output Ports | Configurable (1 or 2 CCD outputs, motorized slit) |
| 焦平面尺寸 | 28 mm × 14 mm |
| Grating Size | 68 mm × 68 mm |
| Slit Width | Dynamic, up to 12 mm |
| Brand | Angstrom |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | ELS5000 |
| Pricing | Upon Request |
| Brand | Angstrom |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ELS5000 |
| Pricing | Upon Request |
| Brand | Angstrom (USA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | LUMO |
| Pricing | Upon Request |
| Brand | Angstrom (USA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | LUMO |
| Pricing | Upon Request |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose VOC Analysis |
| Oven Temperature Range | 100–350 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cool-down Time (100–350 °C) | ~6 min |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Injector Max Operating Temperature | 100–350 °C |
| Injector Pressure Setpoint Range | 0–970 kPa |
| Injector Total Flow Setpoint Range | 0–1000 mL/min] |
| Brand | Anjie |
|---|---|
| Origin | Shanghai, China |
| Model | AJ-1000 |
| Product Type | Flow Injection Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 162 positions |
| Reagent Positions | 3–8 |
| Flow Cell Path Length | 10 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | Anjie |
|---|---|
| Origin | Shanghai, China |
| Model | AJ-3000 Plus |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1 nm, 0.2 nm, 0.4 nm, and 1.0 nm (selectable) |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | 0.1 nm |
| Brand | Anjie |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Photomultiplier Tube (PMT) Detector |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1 nm / 0.2 nm / 0.4 nm / 1.0 nm (selectable) |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ±0.1 nm |