| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CON700 |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Model | COND600 |
| Origin | USA |
| Instrument Type | Portable Conductivity/TDS/Temp Meter |
| IP Rating | IP67 |
| GLP Compliance | Yes |
| Measurement Principles | Two-electrode AC conductivity, temperature-compensated TDS calculation (linear α coefficient), NIST-traceable calibration |
| Key Ranges | Conductivity 0–200.0 mS/cm (5-range auto-ranging) |
| Resolution | 0.01 µS/cm (low range) to 0.1 mS/cm (high range) |
| Accuracy | ±1% of full scale + 1 LSD (conductivity & TDS) |
| Calibration | Up to 4-point automatic or 5-point manual using standard KCl solutions |
| Temperature Compensation | Linear, user-selectable α (0.00 to 10.00 %/°C), default 2.00 %/°C |
| Electrode Constant Range | 0.010–10.000 cm⁻¹ |
| Data Storage | 500 measurement sets with timestamp, temperature, and electrode ID |
| Connectivity | RS-232C serial port, IrDA infrared interface |
| Power | 4×AA alkaline batteries (≥200 h operation) or optional 9 V DC adapter (500 mA) |
| Dimensions (unit) | 18.3 × 9.5 × 5.7 cm |
| Weight (unit) | 460 g |
| Operating Environment | 0–50 °C, ≤95% RH non-condensing |
| Storage Environment | −25–70 °C |
| Display | Backlit LCD (5.4 × 7.1 cm active area), multi-parameter real-time view |
| Auto-off | Configurable 2–30 min idle timeout |
| Auto-hold | Yes |
| Certifications | CE, RoHS, FCC Class B |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | CAD |
| Instrument Type | Universal Chromatographic Detector |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Thermo Fisher Corona CAD |
| Pricing | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Corona Veo |
| Instrument Type | Universal Chromatographic Detector |
| Flow Rate Range | 0.01–2.0 mL/min |
| Detection Principle | Charged Aerosol Detection (CAD) |
| Sensitivity | Sub-nanogram |
| Linear Dynamic Range | >4 orders of magnitude |
| Compatibility | HPLC, UHPLC, microLC, capillary LC |
| Software Drivers | Chromeleon CDS, ChemStation, EZChrom, OpenLab, Empower 2/3 |
| Regulatory Compliance | Supports 21 CFR Part 11 audit trails, GLP/GMP-compliant data integrity workflows |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | CON 6000 |
| Conductivity Range | 0.000–500.0 mS/cm |
| Resistivity Range | 3 Ω·cm – 100 MΩ·cm |
| TDS Range | 0.0–500.0 ppt |
| Accuracy | ±0.5% of full scale + 1 digit |
| Repeatability | ±0.01% of full scale |
| Temperature Range | −5.0 to 105.0 °C |
| Temp. Accuracy | ±0.2 °C |
| Temp. Repeatability | ±0.1 °C |
| Calibration | Auto or manual up to 4-point per range |
| Cell Constants | 0.1, 1.0, 10.0 cm⁻¹ |
| Display | 640 × 480 pixel color TFT touchscreen |
| Data Storage | Up to 10,000 readings with timestamp and user ID |
| Connectivity | USB, IrDA, RS-232C, Ethernet (RJ45) |
| Power | 9 VDC, 3.3 A, center-negative |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Dual Star Kit |
| Instrument Type | Benchtop |
| Parameter Channels | Dual-Channel (pH + ISE) |
| pH Accuracy | ±0.001 |
| pH Range | −2.000 to 19.999 |
| Resolution | 0.1 / 0.01 / 0.001 (user-selectable) |
| mV Range | ±1999.9 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1 mV |
| ISE Concentration Range | 0–19999 (with up to 3 significant digits) |
| ISE Accuracy | ±0.1 mV equivalent |
| Temperature Range | −5 to 105 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Calibration Points | pH: 1–6 pts |
| ISE | 2–6 pts |
| Calibration Modes | Linear, Nonlinear, Standard Addition/Subtraction, Auto-Blank Correction |
| Data Storage | 1000 GLP-compliant entries (manual, timed, or auto-triggered) |
| Input Interfaces | Two BNC pH/ISE electrode ports, one 8-pin mini-DIN ATC probe port, reference electrode input |
| Output Interfaces | RS232, USB |
| Power Supply | 100–240 V AC adapter |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Dual Star |
| Instrument Type | Multifunctional Electrochemical Analyzer |
| pH Range | –2.000 to 19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| Calibration Points | 1–6 |
| Auto-Buffer Recognition | US, NIST, DIN, and User-Defined Buffers |
| Ion Concentration Range | 0–19999 |
| Ion Resolution | 1–3 significant digits |
| Ion Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| Ion Units | ppm, mg/L, M, %, or unitless |
| ISE Methods | Single or Dual Known Addition/Standard Addition, Sample Addition/Subtraction |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| Temperature Range | –5 to 105 °C |
| Temperature Resolution | 0.1 °C (–5 to 99.9 °C), 1.0 °C (>99.9 °C) |
| Temperature Accuracy | ±0.1 °C |
| Display | Dual-channel LCD |
| Inputs | Two BNC, Two Reference Electrode, Two MiniDIN (for ATC probes) |
| Method Storage | 20 methods |
| Password Protection | Yes |
| Data Storage | 1000 readings |
| GLP Compliance | Yes |
| Data Interface | Bidirectional RS232, optional USB cable |
| IP Rating | IP54 |
| Safety Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45 °C, 5–85% RH (non-condensing) |
| Power Supply | 4×AA batteries or universal AC adapter |
| Dimensions | 9.4 cm (H) × 17.0 cm (W) × 22.4 cm (D) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Dispersive Raman Spectrometer (not FT-Raman) |
| Spectral Range | 50–6000 cm⁻¹ |
| Spectral Resolution | <2 cm⁻¹ |
| Spatial Resolution | Micron-level |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | ±0.2 cm⁻¹ |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | EASY-nLC 1000 |
| Instrument Type | Nanoflow Liquid Chromatography System |
| Column ID | 50 µm |
| Packing Particle Size | 1.9 µm |
| Maximum Operating Pressure | Up to 1000 bar |
| Gradient Precision | <0.2% RSD |
| Flow Rate Range | 50–1000 nL/min |
| Injection Volume Precision | <1% RSD |
| System Dead Volume | <100 nL |
| Software Platform | Thermo Scientific Xcalibur |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | EASY-nLC 1200 |
| Instrument Type | Nanoflow Liquid Chromatography System |
| Maximum Operating Pressure | 1200 bar |
| Column Compatibility | 75 cm columns packed with 1.9 µm particles |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Origin Category | Imported |
| Model | ELEMENT 2 |
| Instrument Type | Magnetic Sector ICP-MS (not quadrupole) |
| Sensitivity | >10⁹ cps/ppm for In |
| Resolution | 300, 4,000, and 10,000 (10% valley definition) |
| Dynamic Range | >10⁹ (linear) |
| Background Equivalent Concentration (BEC) | <0.2 cps |
| Detection Mode | Simultaneous multi-element detection for transient signals |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ESCALAB Xi+ |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Eutech Instruments (a Thermo Fisher brand) |
| Type | Portable Conductivity/TDS/Temperature Meter |
| Model | CON110 |
| Conductivity Range | 0–199.9 mS/cm (5 ranges) |
| Resolution | 0.05% of full scale |
| Conductivity Accuracy | ±1% FS + 1 LSD |
| TDS Range | 0–99.9 ppt (adjustable coefficient 0.40–1.00) |
| TDS Accuracy | ±1% FS + 1 LSD |
| Temperature Range | 0–100.0 °C |
| Temp Accuracy | ±0.5 °C |
| Temp Compensation | Automatic/manual (0–80 °C) |
| Calibration | Auto 4-point / Manual 5-point |
| Data Storage | 100 measurement sets with timestamp |
| Electrode Constant Display | Yes (0.1, 1.0, 10.0 cm⁻¹) |
| Interface | RS232C |
| Power | 4×AAA alkaline batteries (200+ hr life) or 9 V DC adapter |
| Dimensions (unit) | 18 × 9 × 4 cm |
| Weight (unit) | 220 g |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | COND600 |
| Price | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Eutech Instruments (a Thermo Fisher brand) |
| Type | Benchtop Conductivity/TDS/Temp Meter |
| Model | CON510 |
| Key Features | Auto-ranging (5 ranges), 4-point auto-calibration & 5-point manual calibration, built-in temperature compensation (NTC thermistor), 100-data storage, adjustable TDS factor, electrode constant selection (0.1 / 1.0 / 10.0 cm⁻¹) |
| Conductivity Range | 0–19.99 μS/cm, 20.0–199.9 μS/cm, 200–1999 μS/cm, 2.00–19.99 mS/cm, 20.0–199.9 mS/cm |
| Conductivity Resolution | 0.01 / 0.1 μS/cm |
| TDS Range (user-selectable factor) | 0–9.99 ppm, 10.0–99.9 ppm, 100–999 ppm, 1.00–9.99 ppt, 10.0–99.9 ppt, 0–199.9 ppt |
| TDS Resolution | 0.01 / 0.1 / 1 ppm |
| Conductivity Accuracy | ±1% full scale |
| Temperature Range | 0.0–80.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Temp. Compensation Coefficient | 0.0–10.0 %/°C |
| Reference Temperature | 15.0–30.0 °C |
| Display | LCD (5.9 × 3.2 cm), backlit |
| Power | 9 V DC regulated adapter (100–220 VAC input, linear supply) |
| Dimensions (H×W×D) | 23 × 18 × 6 cm |
| Weight | 750 g (instrument only) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | CON6000 |
| Price | Upon Request |
| Conductivity Range | 0–200 μS/cm, 200.0 μS/cm–2.000 mS/cm, 2.000–20.00 mS/cm, 20.00–500.0 mS/cm |
| TDS Range | 0–200.0 ppm, 200.0–2000 ppm, 2.000–20.00 ppt, 20.00–500.0 ppt |
| Salinity Range | 0–90.00 ppt |
| Resistivity Range | 0–19.99 kΩ, 20.00–199.9 kΩ, 200.0 kΩ–1.999 MΩ, 2.000–100.0 MΩ |
| Temperature Range | −5.0–105.0 °C |
| Conductivity Accuracy | ±0.5% of full scale + 1 LSD |
| TDS/Salinity/Resistivity Accuracy | ±0.5% of full scale + 1 LSD |
| Temperature Accuracy | ±0.2 °C |
| Temperature Compensation | Automatic or manual (−5 to 100 °C), adjustable coefficient (0.000–10.000 %/°C), reference temperature (15.0–30.0 °C) |
| Calibration | Up to 4-point, auto- or manual |
| Electrode Constants Supported | 0.1, 1.0, 10.0 cm⁻¹ |
| Data Storage | 1,000 readings per user |
| Display | 11.43 × 15.24 cm Windows CE–based color touchscreen |
| Connectivity | BNC, DIN, phono sockets, SD card reader, USB (host & device), RS232C, RJ45, IrDA |
| Power Supply | 9 V DC regulated adapter (100–240 VAC input, SMPS) |
| Dimensions (H×W×D) | 16.5 × 23.5 × 8.9 cm |
| Weight | 1.1 kg (instrument only) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Model | pH 610 |
| Type | Portable Electrochemical Analyzer |
| Measurement Parameters | pH, ORP (mV), Temperature (°C) |
| pH Range | −2.000 to 20.000 |
| pH Resolution | 0.001 / 0.01 / 0.1 |
| pH Accuracy | ±0.002 |
| ORP Range | ±2000.0 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±0.2 mV + 1 LSD |
| Temperature Range | −10.0 to 110.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Calibration Points | 1–6 |
| Auto-Buffer Recognition | USA, NIST, DIN, PWB, Custom |
| Temperature Compensation | Automatic or Manual (0.0–100.0 °C) |
| GLP Compliance | Yes |
| Data Storage | 500 readings with timestamp, electrode ID, and calibration history |
| IP Rating | IP67 |
| Display | Backlit LCD (5.4 × 7.1 cm) |
| Communication | IrDA infrared, RS232C, no cables required |
| Power | 4×AAA alkaline batteries (≥500 h life) or 9 V regulated DC adapter (500 mA) |
| Dimensions (H×W×D) | 18.3 × 9.5 × 5.7 cm |
| Weight | 460 g (instrument only) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Evolution One Plus |
| Instrument Architecture | Double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190 nm to 1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 1.0 nm (fixed) |
| Wavelength Accuracy | ±0.5 nm (at Hg lines 541.9 nm and 546.1 nm), ±0.8 nm (full range 190–1100 nm) |
| Wavelength Repeatability | ≤0.05 nm (SD, n=10 at 546.1 nm Hg line) |
| Stray Light | <0.01% T (i.e., >2 A at specified wavelengths) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Evolution One |
| Instrument Architecture | Double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Automation | Motorized Auto-Scanning |
| Spectral Bandwidth | 0.5–4 nm (selectable) |
| Wavelength Accuracy | ±0.5 nm (at Hg emission lines 541.9 nm and 546.1 nm), ±0.8 nm (full range) |
| Wavelength Repeatability | ≤0.05 nm (SD, 10 measurements at 546.1 nm Hg line) |
| Stray Light | <0.01% T (at 220 nm, NaI |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Double-beam UV-Vis spectrophotometer |
| Detector | Photodiode array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Repeatability | ≤0.05 nm (at 546.1 nm Hg line, SD of 10 measurements) |
| Spectral Bandwidth | Fixed 1.0 nm |
| Baseline Flatness | ±0.001 A (200–800 nm, 1.0 nm SBW, smoothed) |
| Photometric Accuracy | ±0.010 A (60 mg/L K₂Cr₂O₇) |
| Stray Light | ≤1% T @ 198 nm (KCl) |
| Wavelength Accuracy | ±0.5 nm (Hg lines at 541.9/546.1 nm), ±0.8 nm (full range) |
| Photometric Precision | ±0.004 A at 1 A, ±0.008 A at 2 A (NIST-traceable neutral density filters, 440 nm) |
| Noise Level | ≤0.00015 A (0 A), ≤0.00025 A (1 A), ≤0.00050 A (2 A, RMS, 260 nm, 1.0 nm SBW) |
| Drift | <0.0005 A/h (500 nm, 1.0 nm SBW, after 1 h warm-up) |
| Light Source | Xenon flash lamp |
| Dimensions (L×W×H) | 593 × 475 × 266 mm |
| Weight | 14.5 kg |
| Power Requirement | 100–240 V AC, auto-switching, 50/60 Hz, max. 150 W |
| Warranty | 2 years instrument, 3 years lamp |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | GasBench II |
| Instrument Category | Stable Isotope Ratio Mass Spectrometer Interface |
| Measurement Precision | High-precision isotopic ratio analysis |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | GC IsoLink II |
| Instrument Category | Dedicated GC-IRMS Interface System |
| Pricing Range | USD 135,000 – 270,000 (FOB Hamburg) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Genesys 30 |
| Optical Design | Single-Beam |
| Detector Type | Photodiode Array |
| Wavelength Range | 325–1100 nm |
| Wavelength Accuracy | ±1.0 nm |
| Spectral Bandwidth | 5 nm |
| Stray Light | <0.05% at 340 nm and 700 nm |
| Absorbance Range | ±3.0 A |
| Light Source | Tungsten Halogen Lamp |
| Display | 5-inch Full-Color TFT LCD |
| Data Export | USB Mass Storage Mode (TXT format) |
| Software | Onboard VISIONlite UI |
| Warranty | 3 Years Limited |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ICS-2100 |
| Instrument Type | Laboratory Benchtop System |
| Maximum Pump Pressure | 6000 psi |
| Operating Pressure Range | Up to 5000 psi |
| Column Oven Temperature Range | 4–40 °C |
| Eluent Concentration Range | 0–100 mM KOH (varies with eluent chemistry) |
| Detection Principle | Suppressed Conductivity Detection with Electrolytic Eluent Generation and Electrolytic Sample Preparation |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | 3-Star |
| Price | Upon Request |
| Conductivity Range | 0.000–3000 mS/cm |
| Resolution | Up to 4 significant digits, down to 0.001 μS/cm |
| Accuracy | ±0.5% of reading or ±0.01 μS/cm (whichever is greater) |
| Resistivity Range | 0.0001–100 MΩ·cm |
| Salinity Range | 0.01–80.0 ppt NaCl |
| TDS Range | 0–19999 mg/L |
| Cell Constant Range | 0.001–199.9 cm⁻¹ |
| Reference Temperatures | 5, 10, 15, 20, or 25 °C |
| Electrode Compatibility | Two-electrode, four-electrode, and planar conductivity cells |
| Calibration Points | 1–5 manual points |
| Temperature Range | −5 to 105 °C |
| Temp. Resolution | 0.1 °C (−5 to 99.9 °C), 1.0 °C (>99.9 °C) |
| Temp. Accuracy | ±0.1 °C |
| Temp. Compensation | Automatic or manual |
| Display | Backlit LCD with icon-driven interface |
| Input Interfaces | pH-BNC, temperature-miniDIN, stirrer-Phono-jack (benchtop only) |
| Communication | Bidirectional RS232, optional USB cable |
| Data Logging | 1000 readings |
| Calibration History | Last 10 calibrations stored |
| Method Storage | 10 user-defined methods |
| Password Protection | 10 independent user profiles |
| Power | 4×AA alkaline batteries |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45 °C, 5–85% RH (non-condensing) |
| IP Rating | Benchtop: IP54 |
| Portable | IP67 |
| Dimensions (Benchtop) | 9.4 × 17.0 × 22.4 cm (H×W×L) |
| (Portable) | 4.8 × 9.7 × 21.3 cm (H×W×L) |
| Battery Life (Portable) | ~2000 hours |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 4-Star |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | A215 (Benchtop), A325 (Portable) |
| Instrument Category | Benchtop |
| Parameter Types | Dual (pH & Conductivity) |
| Measurement Accuracy | ±0.001 pH / ±0.5% of reading (conductivity) |
| Conductivity Range | 0.001 μS/cm to 3000 mS/cm |
| Resolution | 0.001 μS/cm minimum or 4 significant digits |
| Calibration Solutions | Auto-recognized (USA/NIST/DIN buffers) |
| Data Storage | 2000 entries (A215), 5000 entries (A325), GLP-compliant |
| Environmental Rating | IP54 (benchtop), IP67 (portable) |
| Power | AC adapter or 4 × AA batteries |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | A215 (Benchtop), A325 (Portable) |
| Measurement Parameters | pH, mV/RmV, Conductivity, TDS, Salinity, Resistivity, Temperature |
| Portability | Benchtop (A215) / IP67-rated Portable (A325) |
| Conductivity Range | 0.001 µS/cm to 3000 mS/cm |
| TDS Range | 1–200 ppt |
| Resistivity Range | 2 Ω·cm to 100 MΩ·cm |
| Salinity Range | 0.01–80.0 ppt NaCl (relative) / 0.01–42 ppt practical salinity |
| Temperature Range | –5 °C to +105 °C |
| pH Accuracy | ±0.001 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | A216 (Benchtop), A326 (Portable) |
| Instrument Category | Benchtop |
| Parameter Count | Dual (pH & DO) |
| pH Accuracy | ±0.001 |
| pH Measurement Range | −2.000 to 20.000 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| mV Range | ±2000.0 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1 mV |
| Polarographic DO Range | 0–90 mg/L |
| RDO Fluorescence DO Range | 0–50 mg/L |
| RDO DO Accuracy | ±0.1 mg/L (0–8 mg/L), ±0.2 mg/L (8–20 mg/L), ±10% of reading (20–50 mg/L) |
| DO Saturation Range | 0–600% (polarographic), 0–500% (RDO) |
| DO Saturation Accuracy | ±2% |
| Atmospheric Pressure Compensation | 450.0–850.0 mmHg |
| Salinity Correction | 0–45 ppt |
| Temperature Range | 0–50 °C |
| Temperature Accuracy | ±0.1 °C |
| Data Storage | 2000 entries (A216), 5000 entries (A326), with timestamp, date, sample ID, user ID, calibration data |
| Compliance | GLP-compliant data logging |
| Connectivity | RS232, USB |
| Power | 4 × AA batteries or AC adapter |
| IP Rating | IP54 (A216), IP67 (A326) |