Chemical Analysis Instruments
Filter
Showing 2101–2130 of 4548 results
| Brand | Jiapeng |
|---|---|
| Model | BS-100A |
| Type | Liquid-phase Fraction Collector |
| Collection Mode | Time-based |
| Tube Capacity | 100 × 12 mL |
| Timing Range | 1 s – 24 h (adjustable in 1-s increments) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention After Power Loss | ≥10 years |
| Display | Large Blue-backlit Chinese LCD with Menu-driven Interface |
| Housing Material | ABS Plastic (Injection-molded, Closed-loop Design) |
| Panel Angle | 35° Ergonomic Tilt |
| Tube Rack | Circular, Digitally Labeled (1–100), Interchangeable with Standard 12-mL Tube Formats |
| Valve Type | Keebio Fluid Shut-off Solenoid Valve |
| Compatibility | External Trigger via RS-232 COM Port (for Synchronization with Peristaltic Pumps) |
| Brand | Jingcheng Huatai |
|---|---|
| Origin | Beijing, China |
| Model | HT-350 |
| Measurement Principle | High-frequency electromagnetic wave (radio frequency, 1–10 MHz) |
| Moisture Range | 0–80% w/w |
| Accuracy | ±(0.5% of reading + 1%) |
| Resolution | 0.1% |
| Response Time | 1 second |
| Operating Temperature | −10 °C to 50 °C |
| Operating Humidity | 35–85% RH |
| Display | 4-digit LCD with backlight |
| Power Supply | 4 × AAA batteries |
| Dimensions (main unit) | 140 mm × 60 mm × 24 mm |
| Sensor Probe Length | Standard 235 mm (custom lengths available) |
| Net Weight | ~120 g |
| Compliance | Designed for industrial QC environments |
| Brand | Jingfei Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | FLB1012 |
| Price | Upon Request |
| Weight | 1200 g |
| Material | Black Anodized Aluminum |
| Dimensions | 150 mm (L) × 65 mm (W) × 65 mm (H) |
| Optical Interface | SMA905 |
| Adjustable Aperture Width | Up to 120 mm |
| Brand | Jingpu Technology |
|---|---|
| Origin | Henan, China |
| Model | JP-AFL25B |
| Instrument Type | Portable |
| FTIR Architecture | Interferometric (Michelson-type) |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Spectral Resolution | ≤1 cm⁻¹ |
| Wavenumber Accuracy | ≤0.01 cm⁻¹ |
| Signal-to-Noise Ratio (SNR) | >45,000:1 (at 4 cm⁻¹, 1 min scan, MCT detector) |
| Beam Splitter | Multi-layer coated KBr with hydrophobic coating |
| Detector | Dual-mode DTGS / MCT (user-selectable) |
| IR Source | Long-life air-cooled high-intensity broadband source |
| Scan Speed | Software-selectable, continuously variable (0.1–2.5 cm/s) |
| Optical Platform | Monolithic hardened aluminum base with integrated interferometer and detector chambers |
| Mirror System | Gold-coated corner-cube retroreflectors (monolithic, adhesive-free) |
| Environmental Protection | Industrial-grade resistive humidity control + physical desiccant barrier |
| Data Interface | USB 2.0/3.0 |
| OS Compatibility | Windows 7/10/11 (64-bit) |
| Software | IRPro v5.x (database-driven, ASTM E2412 & EN 14078 compliant modules included) |
| Certified Compliance | ISO 9001, AAA Measurement Management System, EMC-compliant per GB/T 18268.1–2010 (CNAS-verified) |
| Brand | JKRD |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SP7800 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analysis |
| Warranty & Service | On-site Installation, Commissioning, and Comprehensive After-Sales Support |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | JP-2D |
| Price | Upon Request |
| Brand | JU CHUANG ENVIRONMENTAL |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Domestic |
| Model | UV-759CRT |
| Optical Design | Single-beam |
| Detector | CMOS array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | 0.1 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | ≤0.05% T at 220 nm and 360 nm |
| Photometric Accuracy | ±0.003% T |
| Photometric Repeatability | 0.001% T |
| Absorbance Range | –0.30 to 3.00 A |
| Transmittance Range | 0.0–200.0% T |
| Concentration Range | 0–1999 units |
| Baseline Flatness | ±0.001 A |
| Stability | ±0.0005 A/h at 500 nm |
| Interface | USB (RS-232 emulation) |
| Display | 128×64 graphic LCD |
| Data Storage | 200 calibration curves + 200 measurement sets |
| Software Support | UV-759CRT dedicated analysis software |
| Brand | Ju Chuang Environmental |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JC-350X |
| Form Factor | Benchtop/Floor-Standing |
| Instrument Type | Conventional EDXRF |
| Application Scope | General-Purpose |
| Detection Range | 0.07 ppm – 99.9% |
| Energy Resolution | 125 eV (at Mn Kα) |
| Repeatability | ≤0.1% RSD (for major elements, 100 s counting) |
| Detector | Peltier-cooled Silicon Drift Detector (SDD) |
| Measurement Range | 1–45 keV |
| High Voltage | 5–50 kV |
| Tube Current | 5–1000 µA |
| Vacuum Level | ≤10⁻² Pa within 10 s (operational range: 10⁻¹–10⁻⁵ Pa) |
| Sample Imaging | 5 MP CCD camera with real-time positioning |
| Power Consumption | 50 W (main unit), 550 W (vacuum pump) |
| Dimensions | 720 × 440 × 435 mm (W×D×H) |
| Weight | 65 kg |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Powder X-ray Diffractometer |
| Configuration | Benchtop |
| X-ray Source | Sealed Mo-target Tube |
| Maximum Power | 1600 W |
| Angular Accuracy | ±0.01° |
| Angular Resolution | 0.1° |
| Goniometer Geometry | Vertical θ–2θ |
| Goniometer Radius | 144 mm |
| Angular Range | 0°–150° |
| Detector | Photon-counting 2D Array Detector |
| Sample Stage | Temperature-Controlled Pouch-Cell Holder (−30 °C to 300 °C) |
| Dimensions | 900 mm × 680 mm × 550 mm |
| Weight | 100 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | K5P10-1-J2 |
| Pricing | Upon Request |
| Brand | KA |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | hytrace Integrated Analyzer |
| Instrument Type | Portable Gas Chromatograph |
| Application Scope | General-purpose, Hydrogen Purity Monitoring |
| Oven Temperature Range | Ambient +4 °C to 450 °C |
| Ramp Rate | Up to 75 °C/min |
| Cool-down Time | ~6 min (from 400 °C to 50 °C) |
| Carrier Gas Flow Control Range | 30–100 mL/min |
| Carrier Gas Pressure Control Range | 90–100 psig |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setting Range | 3–25 psig |
| Injector Total Flow Setting Range | 5–200 mL/min |
| Brand | Kaiyuanhongsheng |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Benchtop Laboratory Analyzer |
| Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) with Thermal Decomposition |
| Detection Limit | 0.001 ng |
| Repeatability | RSD ≤ 1% at 1 ng |
| Linearity Error | ±3% across calibration range |
| Measurement Range | 0.005–1500 ng Hg per sample |
| Brand | Kaiyuanhongsheng |
|---|---|
| Origin | Hunan, China |
| Model | TN3000 |
| Principle | Dumas combustion method |
| Nitrogen range | 0.1–200 mg N |
| Sample mass | 0.01–0.5 g |
| Repeatability | RSD ≤ 0.5% at 10 mg N |
| Recovery rate | ≥ 99.5% |
| Power consumption | ≤ 3000 W |
| Dimensions (L×W×H) | 500 × 465 × 485 mm |
| Sample capacity | 120-position auto-sampler |
| Analysis time per sample | ≤ 3 min |
| Carrier gas | CO₂ (≥99.99%) |
| Oxidant | O₂ (≥99.99%) |
| Reduction medium | High-efficiency Cu furnace (≥5000 cycles) |
| Gas sampling | Six-way valve quantitative injection |
| Leak detection | Automatic & manual modes |
| Gas flow & pressure monitoring | Real-time display |
| Brand | Kanchang |
|---|---|
| Model | TS-9100 |
| Measurement Principle | UV Fluorescence |
| Detection Element | Sulfur |
| Detection Range | 0.2–10,000 mg/L |
| LOD | 0.1 mg/L |
| Repeatability | RSD < 3% |
| Linearity (R²) | > 0.999 |
| Cracking Furnace Temp | Ambient to 1300 °C (±2 °C) |
| Gas Flow Control | 0–600 mL/min (accuracy ≤1%) |
| Power Supply | AC 220 V, 50 Hz |
| Sample Introduction | Automated Vertical Liquid Autosampler |
| Reaction Gas | Compressed Air (no Ar/O₂ required) |
| Compliance | ASTM D5453, GB/T 34100, GB/T 11060, SH/T 0689, SH/T 1820 |
| Data Export | LIMS-compatible formats |
| Brand | Kanchang |
|---|---|
| Origin | Jiangsu, China |
| Model | TS9000 |
| Detection Principle | UV Fluorescence |
| Detection Range | 0.01–10,000 mg/L |
| LOD | 0.01 mg/L |
| Repeatability | RSD < 3% (0.2–1.0 mg/L), RSD < 2% (1.0–10,000 mg/L) |
| Linearity | Correlation coefficient > 0.999 (linear fit) |
| Furnace Temp Range | Ambient to 1300 °C |
| Temp Control Accuracy | ±2 °C |
| Autosampler Capacity | 156-position liquid autosampler |
| Power Supply | AC 220 V, 50 Hz |
| Brand | Kanchang |
|---|---|
| Model | TX3100 |
| Measurement Principle | Microcoulometric (Coulometric Titration) |
| Elements Analyzed | Chlorine, Sulfur |
| Sample Types | Liquid and Gaseous |
| Injection Volume | 1–100 µL |
| Detection Range | 0.05 mg/L to 5000 mg/L (dilutable beyond) |
| Repeatability | RSD < 3% |
| Combustion Furnace Temp | Ambient to 1300 °C (±1 °C control) |
| Furnace Power | 1000 W |
| Autosampler Capacity | 156-position liquid autosampler |
| Carrier Gas | High-purity N₂ or Ar |
| Reactant Gas | High-purity O₂ |
| Dimensions | 450 × 550 × 450 mm |
| Operating System | Windows 7/10 |
| Compliance | ASTM D5808, D4929, D5194, D3120, D3246 |
| Brand | KB |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | EP-06 |
| Output Voltage Range | 0–100 V (digital display, presettable) |
| Output Current Range | 0–6 A (digital display, presettable, with overload protection) |
| Timing Control | 1 s – 99 min 59 s (digital, audible alert at end) |
| Standard Electrolyte Compatibility | Oxalic acid, nitric acid–water mixtures, fluoroboric acid |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | KDN-08A |
| Price | USD 1,140 (FOB Shanghai) |
| Sample Throughput | 8 samples per digestion cycle |
| Digestion Time | ~40 min |
| Nitrogen Range | 0.02–95% (or 0.1–200 mg N per sample) |
| Power Supply | AC 220 V, 50 Hz |
| Digestion Unit Power | 2400 W |
| Distillation Unit Power | 800 W |
| Dimensions (Digestion Unit) | 730 × 300 × 150 mm |
| Dimensions (Distillation Unit) | 380 × 330 × 820 mm |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Domain | Food Safety & Agricultural Residue Testing |
| Oven Temperature Range | +5 °C to 400 °C |
| Maximum Ramp Rate | 40 °C/min |
| Cooling Time (from 400 °C to 50 °C) | ≤4 min |
| Carrier Gas Flow Range | 0–1000 mL/min |
| Carrier Gas Pressure Control Range | 0–100 psi |
| Injector Temperature Range | +5 °C to 400 °C |
| Injector Pressure Setting Range | 0–0.04 MPa |
| Total Injector Flow Setting Range | 0–1000 mL/min |
| Column Oven Dimensions | 280 × 280 × 180 mm |
| Weight | 56 kg |
| Power Consumption | 2000 W |
| Brand | KEGUO |
|---|---|
| Origin | Shanghai, China |
| Model | ONH-506S |
| Instrument Type | O/N/H Elemental Analyzer |
| Hydrogen Detector | Thermal Conductivity Detector (TCD) |
| Analytical Range | O: 0.1 ppm – 20 wt% |
| N | 0.1 ppm – 50 wt% |
| H | 0.01 ppm – 2.0 wt% |
| Precision | O: ±1 ppm or RSD ≤ 1.0% |
| N | ±1 ppm or RSD ≤ 1.0% |
| H | ±0.2 ppm or RSD ≤ 2.0% |
| Sensitivity | 0.001 ppm |
| Analysis Time | 120–240 s |
| Pulse Furnace Power | 8.5 kVA |
| Brand | KHB |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Nova 9600 |
| Pricing | Available Upon Request |
| Brand | KB |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | KEP-5000 |
| Output Voltage | 0–100 V DC (adjustable) |
| Output Current | 0–6 A DC (adjustable) |
| Voltage Resolution | 0.01 V |
| Current Resolution | 0.001 A |
| Temperature Control Range | Ambient to 100 °C ±1 °C |
| Stirring | Integrated magnetic stirrer |
| Cooling | External water-cooled coil |
| Sample Area Control | Aperture diameters 15 mm / 20 mm / 30 mm |
| Data Interface | RS485 (optional), USB storage export |
| Power Supply | AC 220 V, 50 Hz |
| Total Power | 900 W |
| Dimensions (Power Unit) | 292 × 380 × 120 mm |
| Dimensions (Stirrer Unit) | 240 × 190 × 130 mm |
| Weight | 15 kg |
| Brand | KETT |
|---|---|
| Origin | Japan |
| Model | RN-300 |
| Heating Method | Infrared |
| Sample Type | Brown Rice & Polished Rice (polished rice analysis requires optional accessories) |
| Image Sensor | Color CCD Camera |
| Light Source | White Cold-Cathode Fluorescent Lamp |
| Maximum Sample Capacity | 1,148 grains per measurement |
| Analysis Time | Approx. 24 seconds |
| Display | Grain-by-grain classification, count, percentage composition (by number and mass), length/width/projection area, typicality index, embryo retention rate (0 / ½ / full), crack detection |
| Power Supply | AC 100 V ±10%, 50/60 Hz |
| Dimensions (Transport) | 580 × 230 × 420 mm |
| Dimensions (Operation) | 840 × 580 × 115 mm |
| Weight | ~12 kg |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | FJA-2 |
| Instrument Type | Universal Potentiometric Titrator |
| Voltage Measurement Range | −1999.9 to +1999.9 mV |
| Resolution | 0.1 mV |
| Voltage Accuracy | ±0.025% of reading ±2 digits |
| Input Impedance | >10¹² Ω |
| Titration Precision | 0.01 mL |
| Minimum Dispensed Volume | 0.001 mL |
| Titration Error | ≤0.2% (using 0.1 mol/L HCl vs. 0.1 mol/L NaOH) |
| Compliance | GB/T 1792–1988 (mercaptan sulfur in petroleum products) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | JXD-2 |
| Instrument Type | Alkaline Nitrogen & Mercaptan Sulfur Analyzer |
| Measurement Range | ≥3 µg/g |
| Potential Range | 0 to ±1999.9 mV, Resolution: 0.1 mV |
| Potential Accuracy | ±0.025% of reading + 2 digits |
| Input Impedance | ≥1 × 10¹² Ω |
| Burette Capacity | 10 mL, Minimum Dispense Volume: 0.01 mL |
| Relative Error | ≤5% |
| Repeatability | Compliant with SH/T 0162 |
| Dimensions | 240 × 120 × 210 mm |
| Weight | 5 kg |
| Power Consumption | ≤10 W |
| Brand | KEWLAB |
|---|---|
| Model | MA113TA |
| Heating Source | Halogen Lamp |
| Capacity | 110 g |
| Readability | 0.001 g / 0.01% |
| Repeatability | ±0.002 g |
| Temperature Range | 40–230 °C |
| Timer Range | 1–99 min |
| Operating Environment | 5–35 °C |
| Interface | RS232, RJ45 Ethernet |
| Display | Large Capacitive Touchscreen |
| Power Supply | 220 V / 50 Hz |
| Dimensions (L×W×H) | 215 × 195 × 415 mm |
| Sample Pan Material | Precision Cast Aluminum |
| Chamber Material | Multi-layer Stainless Steel |
| Cooling | Dual Fan System |
| Connectivity | Wired (TA series) |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | Anters-1500G |
| Instrument Type | Ambient-Temperature GPC System |
| Pump Flow Range | 0.001–10 mL/min |
| Pump Pressure Range | 0–40 MPa |
| Refractive Index Detector Drift | <1×10⁻⁷ RIU/h |
| RI Detector Cell Volume | 9 µL |
| UV Detector Wavelength Range | 100–200 nm |
| UV Detector Noise | <0.25×10⁻⁵ AU |
| Column Oven Temperature Range | 4 °C to 40 °C above ambient |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Anters-1500G (with Column Kit) |
| Instrument Type | High-Temperature GPC System |
| Key Specifications | Pump Flow Range: 0.001–10 mL/min |
| Max Pressure | 40 MPa |
| Flow Precision | <0.3% RSD |
| Flow Accuracy | <0.06% |
| Autosampler Capacity | 144 × 2 mL vials (standard) |
| Injection Volume | 0.1–100 µL |
| Injection Precision | <0.3% RSD |
| Carryover | <0.1% |
| Column Oven Temp Range | 4–100 °C |
| Temp Stability | ±0.15 °C |
| RI Detector Range | 1.00–1.75 RIU |
| Noise | ≤5×10⁻⁷ RIU |
| Drift | ≤5×10⁻⁶ RIU/30 min |
| Flow Cell Volume | 8 µL |
| Brand | Kezhe / KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | ELSD-2000KS |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength Range | 195–600 nm |
| Detection Method | Dual-beam |
| Light Source | Xenon lamp |
| Laser Wavelength (Standard) | 650 nm |
| Gas Flow Range | 0–5 L/min |
| Nebulization Pressure | 0–100 psi |
| Temperature Control Range | Ambient to 150 °C (±1 °C resolution) |
| Mobile Phase Flow Rate Compatibility | 0–5 mL/min |
| Detector | Imported large-area silicon photodiode |
| Power Supply | 220 V AC |
| Compatible Carrier Gases | Compressed air or nitrogen |
| Core Components | Stainless-steel evaporation tube, maintenance-free stainless-steel nozzle, laser source, photodetector, dedicated ELSD-2000KS chromatography workstation |
| Brand | Kezhe / KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | ELSD-3000KS |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength Range | 195–600 nm |
| Detection Method | Dual-beam |
| Light Source | Xenon Lamp |