Chemical Analysis Instruments
Filter
Showing 4531–4560 of 10742 results
| Brand | Jiebo (JB) |
|---|---|
| Origin | Jiangsu, China |
| Model | TS6 |
| Power Supply | AC 220 V, 50 Hz |
| Display | 19-inch TFT True Color LCD |
| Operating Temperature | 0–50 °C |
| Operating Humidity | <76% RH |
| Power Consumption | 200 W |
| Measurement Time | 90 s |
| Cooling Curve Resolution | 0.1 °C (0–1370 °C) |
| CE Range | 2.30–4.83 wt%, ±0.10 wt% |
| C Range | 2.20–4.30 wt%, ±0.05 wt% |
| Si Range | 0.30–3.80 wt%, ±0.10 wt% |
| Spheroidization Rate (SG) | 60–95%, ±10.0% |
| Tensile Strength Range | HT100–HT350 |
| Data Storage Capacity | 5000 Measurements |
| Correction Offset Range | −0.99 to +0.99 for CE, C, Si |
| Brand | JBS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Analyzer |
| Principle | Cold Vapor Atomic Fluorescence Spectrometry (CVAFS) |
| Detection Limit | ≤0.003 µg/L |
| Repeatability (RSD) | ≤5% |
| Linearity Error | ±5% |
| Zero Drift | <0.2 mV |
| Measurement Range | 0.01–100 µg/L |
| Noise Level | <0.1 mV |
| Correlation Coefficient (Calibration Curve) | ≥0.996 |
| Operating Temperature | 5–35 °C |
| Relative Humidity | ≤80% |
| Environmental Requirements | Low-vibration, low-EMI, mercury-free ambient, well-ventilated location with external exhaust capability |
| Brand | JENCO |
|---|---|
| Origin | USA |
| Model | 3010M |
| Measurement Parameters | Conductivity, TDS, Salinity, Temperature |
| Portability | Handheld (Field-Portable) |
| Intended Use | Industrial Process Monitoring, Field Sampling, Lab Bench Support |
| Conductivity Range | 0–200 mS/cm |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–100 MΩ·cm |
| Temperature Range | 10–110 °C |
| Accuracy | ±0.5% of Full Scale |
| Minimum Resolution | 0.001 µS/cm |
| Electrode Constant Options | 0.1, 1.0, 10.0 cm⁻¹ |
| Temperature Compensation | Automatic (NTC 30 kΩ) |
| Enclosure Rating | IP67 (Waterproof) |
| Data Retention | Non-volatile memory retains calibration and settings after power loss |
| Brand | JENCO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | 3173/3173R |
| Detection Parameter | Conductivity Only (Multi-Parameter Output) |
| Portability | Benchtop |
| Application Environment | Industrial Process Monitoring & Laboratory QC |
| Conductivity Range | 0–200 mS/cm |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–100 MΩ·cm |
| Temperature Range | 10–110 °C |
| Accuracy | ±0.5% of Full Scale |
| Minimum Resolution | 0.001 µS/cm |
| Auto Temperature Compensation | Yes |
| Power Supply | AC/DC Dual Mode |
| Data Interface | RS-232C (3173R only) |
| Memory | Calibration Value Retention After Power Loss |
| Display | Large LCD with Multi-Parameter Simultaneous Readout |
| Brand | JENCO |
|---|---|
| Origin | USA |
| Model Series | 610 / 620D / 650 |
| Measurement Range | 0.0–14.0 pH, ±999 mV (620D & 650) |
| Resolution | 0.1 pH (all models), 1 mV (620D & 650) |
| Accuracy | ±0.2 pH (610), ±0.1 pH (620D), ±0.2% ±1 mV (620D & 650) |
| Automatic Temperature Compensation (ATC) | 0–60 °C (620D only) |
| Calibration | Single-point (610 & 650), Two-point (620D) |
| Operating Temperature | 0–50 °C |
| Battery Life | ~1000 h (610), ~400 h (620D & 650) |
| Power | 4 × 1.5 V button cells (LR44 or equivalent) |
| Dimensions | 150 × 32 × 15 mm (L × W × H) |
| Brand | JENCO |
|---|---|
| Origin | USA |
| Model | 6173 / 6173R |
| pH Range | –6.00 to 20.00 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.01 pH |
| ORP Range | –2000 to +2000 mV |
| ORP Resolution | 1 mV |
| ORP Accuracy | ±0.05% FS |
| Temperature Range | –10.0 to 120.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Calibration Points | 2-point (user-selectable buffers: 4.01/7.00/10.01 or 4.00/6.86/9.18) |
| Temperature Compensation | Automatic or Manual (–10.0 to 120.0 °C) |
| Electrode Slope Compensation | ±30% |
| Zero Offset Compensation | ±90 mV at pH 7.00/6.86 |
| Endpoint Detection & Hold Function | Yes |
| Data Storage | Calibration history retained |
| Communication Interface | RS-232C (6173R only) |
| Power Supply | 6 × AA batteries (1.5 V) or optional AC adapter |
| Dimensions | 230 × 165 × 80 mm |
| Weight | ~650 g (battery-free) |
| Environmental Rating | 0–50 °C, <95% RH non-condensing |
| Certifications | CE compliant |
| Brand | JEOL |
|---|---|
| Origin | Japan |
| Instrument Type | Continuous-Wave (CW) ESR |
| Models | JES-X310, JES-X320 |
| Control System | Fully Computer-Controlled |
| Magnetic Field Control | Advanced Digital Gradient-Stabilized Electromagnet System |
| Operating Mode | X-band (9–10 GHz) |
| Detection Method | Phase-Sensitive Lock-in Detection with Field Modulation |
| Cryogenic Compatibility | Optional Liquid Nitrogen and Helium Cryostat Integration |
| Safety Compliance | IEC 61010-1, CE Marked |
| Brand | JEOL |
|---|---|
| Origin | Japan |
| Instrument Type | Magnetic Sector Mass Spectrometer |
| Application Focus | Dioxin (PCDD/Fs) Analysis |
| GC Compatibility | Dual-Column Interface |
| Detector | Photomultiplier Tube (PMT) |
| Software | Diok Suite (EPA Method 1613 Compliant) |
| Vacuum Integrity | Column Exchange Without Ion Source Venting |
| Regulatory Alignment | Designed for EPA 1613, EU 2017/771, and ISO 18073 Compliance |
| Brand | JEOL |
|---|---|
| Origin | Japan |
| Model | JMS-Q1600GC |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Gas Chromatography-Mass Spectrometry (GC-MS) |
| Series | UltraQuad™ SQ-Zeta |
| Generation | 6th-generation JEOL GC-MS platform |
| Application Scope | Quantitative and Qualitative Analysis in Environmental, Food Safety, Agrochemical, Materials, and Flavor Chemistry |
| Compliance Framework | Designed for GLP/GMP-aligned laboratories |
| Brand | JEOL |
|---|---|
| Origin | Japan |
| Model | JMS-S3000 |
| Ion Optics | SpiralTOF™-plus 2.0 |
| Operating Modes | TOF (standard), Linear TOF (optional), TOF/TOF (optional) |
| Application Scope | Synthetic polymers, biomacromolecules, materials science |
| Brand | JEOL |
|---|---|
| Origin | Japan |
| Instrument Type | Time-of-Flight (TOF) Mass Spectrometer |
| Configuration | Liquid Chromatography–Mass Spectrometry (LC-MS) Platform |
| Ionization Modes | Electrospray Ionization (ESI), Direct Analysis in Real Time (DART™), Cold Spray Ionization (CSI) |
| Intended Use | General-purpose high-resolution mass analysis in research, quality control, and regulatory-compliant laboratories |
| Compliance Context | Designed to support GLP/GMP workflows and data integrity requirements per FDA 21 CFR Part 11 and ISO/IEC 17025 guidelines |
| Brand | JEOL |
|---|---|
| Origin | Japan |
| Model | JMS-T2000GC |
| Type | Time-of-Flight (TOF) GC-MS System |
| Ionization Modes | Electron Ionization (EI), Chemical Ionization (CI), Field Ionization (FI), and Optional Atmospheric Pressure Chemical Ionization (APCI) |
| Mass Accuracy | < 1 ppm (external calibration), < 0.5 ppm (internal lock mass) |
| Mass Resolution | > 10,000 (FWHM, m/z 500) |
| Acquisition Rate | Up to 50 spectra/sec |
| Mass Range | m/z 10–4,000 |
| Detector | Microchannel Plate (MCP) with Delayed Extraction |
| Vacuum System | Dual-stage differential pumping with turbomolecular pumps |
| GC Interface | Direct capillary column coupling with heated transfer line (up to 350 °C) |
| Software | MassCenter™ v5.x with automated deconvolution, library search (NIST, Wiley, JEOL MS Library), and quantitative workflow support |
| Brand | JEOL |
|---|---|
| Origin | Japan |
| Model | JNM-ECZL Series |
| Sample Type | Solid-Liquid Dual-Mode |
| Instrument Category | High-Field NMR Spectrometer |
| System Architecture | Integrated Smart Transceiver System (STS) |
| Multi-Resonance Capability | Standard Configuration |
| Design Principle | Compact High-Field Platform with Digital RF Control |
| Brand | JEOL |
|---|---|
| Origin | Japan |
| Model | JNM-ECZL400R |
| NMR Frequency | 400 MHz (¹H) |
| Magnet Type | Superconducting, Cryogen-Free Option Available |
| Field Homogeneity | < 0.1 Hz/30 min (shimmed) |
| Temperature Control Range | –140 °C to +140 °C |
| Sample Format | Solid, Semi-Solid, Gel, Liquid, and Heterogeneous Samples |
| Probe Compatibility | Broadband Solid-State MAS Probes (e.g., 2.5–4 mm rotors), Static & Variable-Temperature Configurations |
| Optional FFC Module | SPINMASTER FFC2000 (0.01–42 MHz field-cycling range) |
| Optional SMARTracer Module | 0.1–10 MHz |
| Optional 3 T Permanent Magnet Add-on | Extends ¹H Larmor frequency to ~130 MHz |
| Sample Tube Standard | 4 mm or 3.2 mm ZrO₂ MAS rotors (solid) |
| Brand | JEOL |
|---|---|
| Origin | Japan |
| Model | JSX-1000S |
| Elemental Analysis Range | Mg–U (Na–U optional) |
| Quantitative Range | 0.1–99.9 wt% |
| Energy Resolution | <170 eV at Mn Kα |
| Repeatability | ±0.1% RSD |
| X-ray Tube | 5–50 kV, 1 mA, Rh anode |
| Filter Options | Standard — OPEN, ND, Cr, Pb, Cd |
| Detector | Silicon Drift Detector (SDD) |
| Sample Chamber | Ø300 mm × 80 mm H |
| Atmosphere Mode | Air (standard) |
| Imaging System | Integrated color camera |
| Software Suite | Qualitative & Quantitative Analysis, RoHS Compliance Module (Cd, Pb, Hg, Br, Cr), Quick-Analysis Mode, Report Generator, Daily Verification Tool |
| Brand | JEOL |
|---|---|
| Origin | Japan |
| Model | JXA-8230 |
| Accelerating Voltage | 0.2–30 kV (0.1 kV step) |
| Beam Current Range | 1×10⁻¹² – 1×10⁻⁵ A |
| Beam Current Stability | ±5% / h, ±0.3% / 12 h |
| Secondary Electron Resolution | 6 nm (W filament, WD = 11 mm, 30 kV) |
| Magnification | ×40 – ×300,000 |
| Max. Sample Size | 100 mm × 100 mm × 50 mm (H) |
| WDS Elemental Range | Be*¹–U (Be requires optional crystal) |
| EDS Elemental Range | B–U |
| WDS Wavelength Range | 0.087–9.3 nm |
| EDS Energy Range | 0–20 keV |
| WDS Spectrometers | 1–5 channels (configurable) |
| EDS Detector | 1 SDD (optional fanless digital pulse processor) |
| Display | Dual LCDs (1280×1024), dedicated for EPMA analysis and SEM/EDS operation |
| Origin | Shaanxi, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | 1156A |
| Detection Parameter | Single-parameter (Conductivity) |
| Portability | Portable |
| Conductivity Range | 0–1999 pS/m |
| Resistivity Range | 0–1999 pS/m (inverted scale) |
| Temperature Range | 32–165 °F (0–75 °C) |
| Accuracy | ±2% of reading |
| Minimum Resolution | 1 pS/m |
| Calibration | Internal auto-calibration |
| Display | LCD with over-range indicator ("1" on left) |
| Power Supply | Three 6 V alkaline batteries |
| Enclosure | Anodized aluminum housing with corrosion-resistant coating |
| Probe | Detachable, ruggedized for field use |
| Compliance | ASTM D2624, ASTM D4308, ISO 6297, GB/T 6539, GB 6950, GB 13348 |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | JH-1 |
| Pricing | Upon Request |
| Temperature Control Range | Ambient to 380 °C |
| Temperature Accuracy | ±1 °C |
| Calibration/Simulated Sampling Flow Rate | 100–1000 mL/min |
| Activation/Desorption Time Range | 1 min to 24 h (programmable) |
| Repeatability | >95% |
| Tube Dimensions Supported | Ø6 mm diameter, length >120 mm |
| Power Supply | 220 V ±10%, 50–60 Hz |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | JHP-22 |
| Instrument Type | Curie-Point Pyrolyzer |
| Heating Method | High-Frequency Induction with Curie-Point Ferromagnetic Foil |
| Sample Tube | Quartz, 4.5 mm ID (Pyrolysis Chamber) |
| Furnace Temperature Range | Ambient to 200 °C |
| Pyrolysis Duration | 1–99 s |
| Transfer Line Temperature Range | Ambient to 300 °C, Length: 0.7 m |
| RF Power Output | 48 W |
| Flow Path Switching | Solenoid Valve |
| Dimensions (W×H×D) | 305 × 190 × 465 mm |
| Weight | 18 kg |
| Power Supply | AC 100 V, 7 A |
| GC Compatibility | Universal GC Interface (Excluding Proprietary Direct-Coupled Systems) |
| Optional Curie Temperatures | 1040, 920, 764, 740, 670, 650, 590, 500, 485, 445, 423, 386, 358, 333, 315, 280, 255, 235, 220, 170, 160 °C |
| Brand | JIACO |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | JIACO MIP |
| Pricing | Available Upon Request |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | 2001-B Series |
| Instrument Type | Low-Pressure Liquid Chromatograph (LPLC) |
| Flow Rate Range | 0.5–900 mL/h (dual-channel), up to 14,500 mL/h (single-channel) |
| UV Detection Wavelengths | 260 nm & 280 nm (standard) |
| optional | 310 nm & 405 nm |
| Detector | JP-3000 Dual-Beam Nucleic Acid/Protein UV Detector |
| Fraction Collector | DBS-100 / CBS-B / BSZ-100 (configurable, 100-tube capacity, max 12 mL/tube) |
| Collection Modes | Time-based, Drop-counting, Peak-triggered (0–100 mV or 0–250 mV threshold), Programmable tube numbering |
| Gradient Mixing | TH-500A Gradient Mixer (1000 mL capacity) |
| Column Compatibility | GE-compatible interfaces (e.g., for pre-purification on AKTA systems) |
| Display | High-contrast blue-membrane LCD with real-time dual-beam zero calibration |
| LED Light Source Lifetime | >50,000 hours |
| Data Acquisition | Real-time logging of time, UV absorbance, gradient profile, fraction index, and optional conductivity/temperature inputs |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | 2001-C Series |
| Instrument Type | Fast Low-Pressure Liquid Chromatograph |
| Application Scope | General-Purpose Analytical Instrument |
| Compliance | CE-marked design principles (intended for research-use-only environments) |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | BS-100A |
| Instrument Type | Liquid-phase Fraction Collector |
| Collection Mode | Time-based |
| Tube Capacity | 100 × 12 mL |
| Timing Range | 1 s – 24 h (adjustable in 1-s increments) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention on Power Loss | 10 years |
| Display | 6-digit high-brightness LED |
| Tube Tray | Circular, digitally numbered (1–100), solvent-resistant (optional) |
| Control Interface | RS-232 COM port for external pump synchronization |
| Enclosure Material | ABS polymer, injection-molded, fully enclosed |
| Panel Angle | 35° ergonomic tilt |
| Brand | Jiapeng |
|---|---|
| Model | BS-100A |
| Type | Liquid-phase Fraction Collector |
| Collection Mode | Time-based |
| Tube Capacity | 100 × 12 mL |
| Timing Range | 1 s – 24 h (adjustable in 1-s increments) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention After Power Loss | ≥10 years |
| Display | Large Blue-backlit Chinese LCD with Menu-driven Interface |
| Housing Material | ABS Plastic (Injection-molded, Closed-loop Design) |
| Panel Angle | 35° Ergonomic Tilt |
| Tube Rack | Circular, Digitally Labeled (1–100), Interchangeable with Standard 12-mL Tube Formats |
| Valve Type | Keebio Fluid Shut-off Solenoid Valve |
| Compatibility | External Trigger via RS-232 COM Port (for Synchronization with Peristaltic Pumps) |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | BS-160A |
| Instrument Type | Liquid-phase Fraction Collector |
| Collection Mode | Time-based |
| Tube Capacity | 5 mL per tube |
| Max. Tube Count | 160 tubes |
| Timing Range | 1 second to 24 hours (user-selectable) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention on Power Loss | 10 years |
| Display | 6-digit high-brightness LED |
| Housing Material | ABS plastic (injection-molded, enclosed design) |
| Tube Tray | Circular, digitally numbered, solvent-resistant (optional) |
| Valve Type | Keebio fluid shut-off valve |
| External Trigger Interface | RS-232 COM port for pump synchronization |
| Compliance | Designed for GLP-compliant preparative chromatography workflows |
| Brand | Jiapeng |
|---|---|
| Model | BS-160A |
| Type | Liquid-phase Fraction Collector |
| Collection Method | Time-based |
| Tube Capacity | 160 × 5 mL |
| Timing Range | 1 s – 24 h (adjustable in 1-s increments) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention on Power Loss | ≥10 years |
| Housing Material | ABS polymer (chemical-resistant, injection-molded) |
| Display | Backlit Chinese-language LCD with menu-driven interface |
| Tube Tray | Circular, digitally numbered, solvent-compatible (optional) |
| Valve Type | Keebio fluid shut-off solenoid valve |
| External Trigger Interface | RS-232 COM port for synchronized control with peristaltic pumps |
| Compliance | Designed for GLP-aligned laboratory workflows |
| Brand | Jiapeng |
|---|---|
| Model | BS-16A |
| Type | Liquid-phase Fraction Collector |
| Collection Mode | Time-based |
| Tube Capacity | 16 × 100 mL |
| Timing Range | 1 s – 24 h (adjustable in 1-s increments) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 460 mm |
| Weight | 6.5 kg |
| Data Retention | 10 years after power loss |
| Display | 6-digit high-brightness LED |
| Housing Material | ABS polymer (injection-molded, solvent-resistant grade) |
| Panel Angle | 35° ergonomic tilt |
| Tube Tray | Circular, digitally labeled (01–16), interchangeable with standardized 16-position racks |
| External Trigger Interface | RS-232 COM port for synchronized control with peristaltic or piston-driven pumps |
| Valve Type | Keebio precision fluid shut-off valve (standard) |
| Brand | Jiapeng |
|---|---|
| Model | BS-30A |
| Type | Liquid-phase Fraction Collector |
| Collection Method | Time-based |
| Number of Collection Positions | 30 |
| Collection Volume Capacity | Unlimited (via external containers) |
| Timing Range | 1 second to 24 hours (adjustable in 1-second increments) |
| Power Supply | AC 220 V, 50/60 Hz |
| Display | 6-digit high-brightness LED |
| Data Retention After Power Loss | ≥10 years |
| Continuous Operation Time | >200 hours |
| Housing Material | ABS (impact-resistant, solvent-resistant grade) |
| Control Interface | RS-232 COM port for external pump synchronization |
| Dimensions (W×D×H) | 265 × 390 × 530 mm |
| Net Weight | 6.5 kg |
| Brand | Jiapeng |
|---|---|
| Model | BS-40A |
| Type | Liquid-phase Fraction Collector |
| Collection Method | Time-based |
| Tube Capacity | 40 × 50 mL |
| Timing Range | 1 s – 24 h (adjustable in 1-s increments) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 530 mm |
| Weight | 6.5 kg |
| Data Retention | 10 years after power loss |
| Display | 6-digit LED数码 tube |
| Tube Tray | Circular, digitally labeled, solvent-resistant (optional) |
| Enclosure Material | ABS plastic, injection-molded, fully enclosed |
| Interface | RS-232 COM port for external trigger (e.g., peristaltic pump synchronization) |
| Compliance | Designed for GLP-compliant preparative chromatography workflows |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | BSZ-100 |
| Collection Capacity | 100 tubes × 12 mL |
| Timing Range | 1 s – 24 h (adjustable in 1-s increments) |
| Display | 6-digit LED |
| Tube Tray | Circular, digitally numbered (001–100) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention on Power Loss | ≥10 years |
| Continuous Operation Time | >200 h |
| Construction Material | ABS polymer (chemical-resistant, injection-molded) |
| Valve Type | Keebio fluid shut-off solenoid valve |
| Interface | RS-232 COM port for external trigger (e.g., peristaltic pump synchronization) |