Chemical Analysis Instruments
Filter
Showing 4501–4530 of 10742 results
| Brand | JAI |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | UV-50 |
| Instrument Type | Ultraviolet Detector (UVD) |
| Wavelength Range | 200–380 nm (selectable via interchangeable interference filters) |
| Standard Wavelength | 254 nm |
| Detection Method | Dual-Beam Filter Photometry |
| Light Source | Deuterium Lamp |
| Noise | ≤0.00005 AU |
| Drift | ≤0.002 AU/hr |
| Flow Cell Path Length | 0.5 mm (standard), optional 0.2 mm or 1.0 mm |
| Flow Cell Volume | 20 µL |
| Saturation Concentration | 4% (at 0.5 mm path length) |
| Output Signals | 100 mV and 10 mV full-scale analog outputs |
| Zero Adjustment | Automatic |
| Dimensions (W×H×D) | 150 × 120 × 420 mm |
| Power Supply | AC 85–135 V, 50/60 Hz, 100 VA |
| Weight | 8 kg |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Chiral LC-4000 |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.01–10 mL/min |
| Maximum Pressure | 70 MPa |
| Sample Loop Capacity | 2 mL (180-position tray) |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | (Ambient + 10 °C) to 200 °C |
| UV-Vis Wavelength Range | 200–460 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CPL-300 |
| Pricing | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FI/IR NRS |
| Price | Upon Request |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Model | FP-8000 Series |
| Wavelength Range | 200–750 nm (up to 900 nm or 1010 nm depending on model) |
| Excitation Source | 150 W Xenon Arc Lamp |
| Spectral Bandwidth (Slit) | 1–20 nm |
| Resolution | 1.0 nm |
| Wavelength Accuracy | ±1.0 nm |
| Sensitivity (S/N) | >500 (RMS, specified at water Raman peak) |
| Scan Speed | Up to 60,000 nm/min |
| Dynamic Range | >6.5 decades |
| Detection Capability | Phosphorescence lifetime down to 1 ms |
| Dispersion Element | Grating + Order-sorting Filters |
| Accessories Interface | IQ-enabled automatic accessory recognition |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Model | FSV-6000 |
| Measurement Range | 850–3200 cm⁻¹ (expandable to 750–4000 cm⁻¹) |
| Detector | Liquid Nitrogen-Cooled MCT |
| Incident Angle | 28° Michelson Interferometer |
| Optical System | Purgeable (N₂ or dry air) |
| Light Source | High-Intensity Ceramic IR Source |
| Optional Feature | Narrowband VCD-optimized Bandpass Filters |
| Compatibility | Fully Integrated with JASCO FT/IR-4000 & FT/IR-6000 Series as VFT-4000 Expansion Module |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Model | FT/IR-4000, FT/IR-6000 Series |
| Instrument Type | Laboratory Fourier Transform Infrared (FTIR) Spectrometer |
| Wavenumber Range | 7800–400 cm⁻¹ |
| Spectral Resolution | 0.4 cm⁻¹ |
| Signal-to-Noise Ratio (S/N) | 55,000:1 (at 4 cm⁻¹, 1 min scan, MCT detector) |
| Sample Compatibility | Up to 300 mm (12″) silicon wafers |
| Measurement Modes | Specular reflectance, transmission, and attenuated total reflectance (ATR) with wafer-specific accessories |
| Compliance | JEITA RC-2001, JEIDA-6301, SEMI F39, ASTM F1597, ISO 14644-1 (cleanroom-compatible operation) |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Model | FT/IR-4000, FT/IR-6000 |
| Instrument Type | Laboratory Benchtop FTIR |
| Wavenumber Range | 25,000–10 cm⁻¹ (extended options available) |
| Spectral Resolution | 0.7–0.07 cm⁻¹ |
| Scan Speed | 20 Hz |
| Signal-to-Noise Ratio | 25,000:1 to 55,000:1 |
| A/D Converter | 24-bit |
| Interferometer | Corner-Cube Retroreflector with Real-Time DSP Mirror Control |
| Optical Stability | Active Beam Alignment Compensation |
| Compatibility | Integrated with JASCO IR Microscopes (e.g., IRT-5200, IRT-7200) |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 11,500–50 cm⁻¹ |
| Spectral Resolution | 0.4 cm⁻¹ |
| Signal-to-Noise Ratio (S/N) | 35,000:1 |
| Dimensions | 386 mm (W) × 479 mm (D) × 290 mm (H) |
| Interferometer | Sealed, Thermally & Hygroscopically Stabilized Michelson |
| Scan Speed | Up to 80 spectra/sec |
| Detector Compatibility | MCT, InGaAs, DTGS |
| Sample Compartment Width | 200 mm |
| Software | Spectrum Manager Ver. 2.5 with Auto-Diagnostic & Guided Workflow |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Model | FT/IR-6X / FT/IR-8X |
| Instrument Type | Laboratory Benchtop FTIR Spectrometer |
| Spectral Range | 25,000–20 cm⁻¹ |
| Spectral Resolution | 0.07 cm⁻¹ |
| Signal-to-Noise Ratio (S/N) | 55,000:1 (at 4 cm⁻¹, 1 min scan, MCT detector, peak-to-peak) |
| Interferometer | 28° Michelson with Corner Cube Retroreflectors |
| Light Source | High-intensity Ceramic Source |
| Detector | Temperature-Controlled DLATGS or Optional MCT |
| Beam Splitter Exchange | Automated Beam Splitter (BS) Switching Unit |
| Software | Spectrum Manager™ Ver. 2.5 |
| Compliance | Fully Compatible with ASTM E1421, ISO 18382, USP <1119>, GLP/GMP Data Integrity Requirements (21 CFR Part 11 Ready) |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Instrument Type | Laboratory Benchtop |
| FTIR Architecture | Interferometer-Based Michelson Design |
| Wavenumber Range | 7800–400 cm⁻¹ |
| Spectral Resolution | 0.07 cm⁻¹ (unapodized, with He–Ne laser referencing) |
| Signal-to-Noise Ratio | 55,000:1 (at 4 cm⁻¹ resolution, 1 min scan, MCT detector, peak-to-peak) |
| Vacuum Performance | <10⁻³ Pa base pressure, <5×10⁻⁴ Pa during spectral acquisition |
| Optical Path Environment | Fully evacuated sample compartment and interferometer housing |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Model | IRT-7200 / IRT-5200 / IRT-1000 |
| Instrument Type | Laboratory FTIR Microscope |
| Wavenumber Range | 25,000–10 cm⁻¹ |
| Spectral Resolution | 0.7–0.07 cm⁻¹ |
| Scan Speed | 20 Hz |
| Signal-to-Noise Ratio | 25,000:1 to 55,000:1 |
| Detector Configuration | 16-channel MCT (IRT-7200), single-element MCT + CMOS visual camera (IRT-5200), compact ATR-integrated module (IRT-1000) |
| Optical Interface | Cassegrain objectives (×16, ×32 standard), ATR imaging capability |
| Software | JASCO Spectra Manager™ with mapping, time-resolved imaging, and co-registered spectral–spatial analysis modules |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Model | J-1500 |
| Instrument Type | Circular Dichroism (CD) Spectrometer |
| Wavelength Range | 163–950 nm (extendable to 1600 nm) |
| Standard Measurement Modes | CD, LD, UV-Vis |
| Optical System | Dual Photoelastic Modulator (PEM) with Vacuum UV-optimized Polarization Optics |
| Compliance | Designed for GLP/GMP-aligned laboratories |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LC-4000 Series |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.01–50 mL/min |
| Maximum Pressure | 130 MPa |
| Sample Loop Capacity | 2 mL (180-position tray) |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | Ambient +10 °C to 200 °C |
| UV-Vis Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LC-4000 |
| Instrument Type | High-Throughput Supercritical Fluid Chromatograph |
| Flow Rate Range | 0.5–150.0 mL/min |
| Maximum Operating Pressure | 30 MPa |
| Flow Precision | <0.1% RSD |
| Injection Volume Range | 0.1–20,000 µL |
| Injection Positions | 180 |
| Column Oven Temperature Range | Ambient to 90°C |
| UV-Vis Detection Wavelength Range | 190–900 nm |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MVS-5000 Series |
| Instrument Architecture | Dual-Wavelength |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 200–2700 nm |
| Automation Level | Motorized Wavelength Scanning |
| Spectral Bandwidth | 1–20 nm |
| Wavelength Accuracy | ±0.3 nm |
| Stray Light | <0.0001% (at 220 nm, NaI |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PR-1w |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 3000–200 cm⁻¹ |
| Spectral Resolution | 3 cm⁻¹ per pixel |
| Laser Excitation Wavelength | 785 nm |
| Detector | Uncooled CMOS |
| Interface | USB 2.0 for PC connectivity |
| Measurement Time | ~2–3 minutes per sample |
| Sample Compatibility | Solids, powders, liquids (including through transparent packaging) |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Model | V-630 Bio |
| Optical System | Single-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.2 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤0.02% T |
| Automation | Motorized Wavelength Scanning |
| Sample Volume Requirement (with 8-position micro-volume rotator) | 4 µL per measurement |
| Temperature Control Option | Peltier-based electronic thermostat (optional) |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Model | V-670 |
| Optical Design | Single-beam |
| Detector | Photomultiplier Tube (PMT) for UV-Vis |
| Wavelength Range | 190–2700 nm (extendable to 3200 nm) |
| Spectral Bandwidth | 0.1, 0.2, 0.5, 1, 2, 5, 10 nm (selectable) |
| Wavelength Accuracy | ±0.3 nm (UV-Vis) |
| Wavelength Repeatability | ±0.05 nm (UV-Vis) |
| Stray Light | ≤0.005% T |
| Automation | Motorized wavelength scanning and slit control |
| Compliance | ASTM E275, ISO 6247, USP <857>, JIS K 0115 |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Instrument Configuration | Double-beam |
| Detector | Photomultiplier Tube (PMT) |
| Automation Level | Motorized Wavelength Scanning |
| Wavelength Range | 250–2000 nm |
| Stray Light | ≤0.003% T |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Model | V-700 Series |
| Optical System | Double-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–3200 nm |
| Wavelength Accuracy | ±0.3 nm |
| Spectral Bandwidth | 0.1, 0.2, 0.5, 1, 2, 5, 10 nm |
| Stray Light | ≤0.005 % |
| Automation | Automatic Wavelength Scanning |
| Compliance | FDA 21 CFR Part 11 (via Spectra Manager CFR Edition) |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | V-7000 Series |
| Optical System | Double-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 175–3300 nm |
| Wavelength Accuracy | ±0.08 nm |
| Spectral Bandwidth | 0–20 nm (variable, motorized slit control) |
| Stray Light | ≤0.00007% (at 220 nm, NaI |
| Photometric Range | ±8.0 Abs |
| Resolution | 0.049 nm (UV-Vis region, using high-resolution grating mode) |
| Software | JASCO Spectra Manager™ (cross-platform, Windows/macOS/Linux compatible) |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Model | V-770 |
| Optical Design | Double-beam |
| Detector | Photomultiplier Tube (PMT) & Peltier-cooled PbS detector |
| Wavelength Range | 190–3200 nm |
| Spectral Bandwidth | 0–40 nm |
| Wavelength Accuracy | ±0.3 nm (UV-Vis), ±1.5 nm (NIR) |
| Wavelength Repeatability | ±0.05 nm (UV-Vis), ±0.2 nm (NIR) |
| Stray Light | ≤0.005% |
| Automation | Motorized wavelength scanning and auto-alignment |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VAP-8010 |
| Pricing | Available Upon Request |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Model | VIR-100 / VIR-200 / VIR-300 |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 7,800–350 cm⁻¹ (standard) |
| Spectral Resolution | 0.4–16 cm⁻¹ |
| Interferometer | Sealed, DSP-driven corner-cube retroreflector with auto-alignment and learning-based active stabilization (VIR-200/VIR-300 only) |
| Detectors | Standard DLATGS |
| Scan Speed | Up to 40 Hz (optional) |
| Power Supply | AC adapter or rechargeable battery operation |
| Compliance | Designed for GLP/GMP environments |
| Brand | JB |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | CS995 Advanced Digital Carbon-Sulfur Analyzer |
| Price | USD 16,800 (FOB Jiangsu) |
| Measurement Principle | Infrared Absorption Spectroscopy |
| Heating System | High-Frequency Induction Furnace (2.5 kW, 20 MHz) |
| Measurement Range | C: 0.0001–6.0000 wt% |
| S | 0.0001–0.5000 wt% |
| Sensitivity | 0.01 ppm (C and S) |
| Precision | ±1 ppm (RSD ≤ 0.5% at mid-range concentration) |
| Analysis Time | ≤35 seconds per sample (including combustion, gas purification, and IR detection) |
| Brand | JB |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | CS995 Carbon-Sulfur Analyzer |
| Price | USD 16,800 (FOB Jiangsu) |
| Measurement Principle | Electrolytic Conductivity Detection |
| Heating System | High-Frequency Induction Furnace (2.5 kHz, 20 kW) |
| Carbon Range | 0.0001–6.0000 wt% |
| Sulfur Range | 0.0001–0.5000 wt% |
| Sensitivity | 0.01 ppm (C and S) |
| Precision | ±1 ppm (RSD ≤ 0.5% at mid-range concentrations) |
| Analysis Time | ≤35 seconds per sample (including combustion, gas purification, and detection) |
| Brand | JB |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | CS995 |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | High-Frequency Induction Furnace (2.5 kHz, 3.5 kW) |
| Carbon Range | 0.0001–6.0000 wt% |
| Sulfur Range | 0.0001–0.5000 wt% |
| Sensitivity | 0.01 ppm (C and S) |
| Precision | ±1 ppm (RSD ≤ 0.5% at mid-range concentrations) |
| Analysis Time | ≤35 s per sample |
| Sample Weighing Range | 0.1–1.0 g (standard crucible mode) |
| Brand | JB |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | CCD-based Multi-Channel Array |
| Focal Length | 401 mm |
| Grating Groove Density | 2400 lines/mm |
| Wavelength Range | 140–680 nm |
| Optical Configuration | Paschen–Runge Mount |
| Number of Simultaneous Analytical Channels | Not Applicable (Full-Spectrum CCD Acquisition) |
| Compliance | Meets ISO 11573:2021 (Metallic materials — Spark optical emission spectrometry), ASTM E415–22 (Standard Test Method for Analysis of Carbon and Low-Alloy Steel by Spark Atomic Emission Spectrometry) |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-362 |
| Compliance | UL 1581, VDE 0472 |
| Oscillation Frequency | 10–40 cycles per minute (CPM), adjustable |
| Stroke Length | 40–100 mm, adjustable |
| Load Mass | 450 g ±5 g (standard), customizable options available |
| Counting Function | Automatic cycle counter with digital display |
| Drive Mechanism | Electromechanical cam-driven linear reciprocating motion |
| Sample Fixturing | Dedicated clamping fixture for 30 mm wire segment with printed surface oriented upward |
| Construction | Powder-coated steel frame with precision-machined aluminum test platform |