| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SFS-101S Halogen Moisture Analyzer |
| Price Range | USD 720 – 1,430 (FOB) |
| Weighing Range | 0.2 g to 110 g |
| Readability (d) | 1 mg |
| Verification Scale Interval (e) | 10 mg |
| Moisture Readability | 0.01% |
| Accuracy Class | Class II (per OIML R76) |
| Minimum Sample Mass | 1 g |
| Heating Source | Circular Halogen Lamp |
| Temperature Control Range | Ambient to 180 °C |
| Heating Chamber Material | Heat-Resistant Engineering Plastic |
| Sample Pan Diameter | 90 mm |
| Real-Time Display | Temperature, Elapsed Heating Time, Dynamic Moisture %, Dry Matter %, ATRO Dry Basis %, ATRO Wet Basis % |
| Drying Modes | Standard, Quick |
| Termination Modes | Automatic (moisture change rate threshold), Manual, Semi-Automatic |
| Interface | RS-232 Serial Port for Thermal Printer Output |
| Power Supply | 220 V ± 10%, 50/60 Hz |
| Dimensions (W×D×H) | 310 × 180 × 157 mm |
| Net Weight | 2.6 kg |
| Brand | Leici |
|---|---|
| Model | SFS-105J Halogen Moisture Analyzer |
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Price Range | USD 700 – 1,400 (FOB Shanghai) |
| Weighing Range | 0.2 g – 110 g |
| Readability (d) | 5 mg |
| Verification Scale Interval (e) | 10 mg |
| Moisture Readability | 0.02 % |
| Accuracy Class | Class II (per OIML R76) |
| Minimum Sample Mass | 1 g |
| Heating Source | Circular Halogen Lamp |
| Temperature Control Range | Ambient to 200 °C |
| Sample Pan Diameter | 90 mm |
| Real-time Display | Temperature, Elapsed Heating Time, Dynamic Moisture %, Dry Matter %, ATRO Dry Basis %, ATRO Wet Basis % |
| Drying Modes | Standard, Rapid, Gradual |
| Endpoint Detection | Automatic, Manual, Semi-Automatic |
| Communication Interface | RS-232 for Thermal Printer Output |
| Power Supply | 220 V ± 10 %, 50/60 Hz |
| Dimensions (W×D×H) | 330 × 200 × 200 mm |
| Net Weight | 5.8 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | SR-1 Robotic Autosampler + ZDJ-6 Titration Unit |
| Application Scope | General-purpose potentiometric titration |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | TR-901 |
| Instrument Type | Laboratory & Field-Portable ORP Meter |
| Measurement Range | ±2000 mV (ORP), 5.0–60.0 °C (Temperature) |
| Resolution | 1 mV (ORP), 0.1 °C (Temperature) |
| Basic Error | ±1 mV (within −1000 to +1000 mV), ±0.1% FS (outside that range) |
| Calibration | 1-point or 2-point ORP calibration |
| Temperature Compensation | Automatic and manual modes |
| Data Storage | 500 measurement sets |
| Protection Rating | IP65 |
| Power Supply | Rechargeable Li-ion battery, compatible with external mobile power banks |
| Display | Color touchscreen with guided navigation interface |
| Sampling Interval | Configurable in minutes |
| Additional Features | Auto-read lock, auto-backlight, auto-power-off, dual-channel ORP input |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Portable |
| Parameter Types | Multi-parameter (pH, ORP, mV, Temperature) |
| pH Measurement Range | –2.00 to 20.00 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.02 pH |
| Calibration | Automatic recognition of GB, DIN, NIST, and other standard pH buffer solutions |
| Data Storage | 500 measurement records with GLP-compliant metadata |
| Environmental Rating | IP65 |
| Connectivity | RS232 printer port, USB interface for PC communication and firmware updates |
| Calibration Options | 1–5 point pH calibration, 1-point ORP calibration |
| Measurement Modes | Continuous, equilibrium-based, and programmable timed (interval or continuous timing) |
| User Management | Configurable user ID and sample ID fields |
| Display | Backlit LCD with graphical curve visualization |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | YHBJ-262 |
| Price Range | USD 280–700 |
| Instrument Type | Laboratory-Grade Portable ORP Meter |
| ORP Range | (−2000.0 to +2000.0) mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy (Electronic Unit) | ±0.1% or ±0.3 mV |
| ORP Repeatability (Electronic Unit) | 1 mV |
| ORP System Accuracy (with electrode) | ±15 mV |
| pH Range | −2.00 to 20.00 |
| pH Resolution | 0.01 |
| pH Accuracy (Electronic Unit) | ±0.01 pH |
| pH Repeatability (Electronic Unit) | 0.005 pH |
| Input Current | ≤1 × 10⁻¹² A |
| Input Impedance | ≥1 × 10¹² Ω |
| pH System Accuracy | ±0.02 pH |
| pH System Repeatability | 0.01 pH |
| Temperature Range | −5.0 to 110.0 °C (23.0 to 230.0 °F) |
| Temp. Resolution | 0.1 °C / 0.1 °F |
| Temp. Accuracy (Electronic Unit) | ±0.2 °C |
| Temp. System Accuracy | ±0.4 °C (0.0–60.0 °C), ±1.0 °C (other ranges) |
| IP Rating | IP65 |
| Dimensions | 80 × 225 × 35 mm |
| Weight | 0.4 kg |
| Power | Rechargeable Li-ion battery |
| AC adapter input | 100–240 V AC, output: 5 V DC |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ZDCL-2 |
| Instrument Category | General-Purpose Potentiometric Titrator |
| Application Specificity | Dedicated for Chloride Ion Analysis |
| Measurement Range | (−1800.0 to +1800.0) mV |
| Meter Accuracy | ±0.20% of full scale |
| Meter Resolution | 0.1 mV |
| Titration Accuracy | (±0.3 mV ±1 digit) over 3 hours |
| Titration Resolution | 1/10,000 |
| Titration Repeatability | ≤0.20% |
| Burette Error | ±0.025 mL (10 mL burette), ±0.035 mL (20 mL burette) |
| Stability | ±0.3 mV / 3 h |
| Operating Environment | 0–40 °C, ≤85% RH |
| Dimensions & Weight | 340 × 400 × 400 mm, ~10 kg |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ZDJ-3A |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | (−1999 to +1999) mV, (0.00 to 14.00) pH |
| Meter Accuracy | ±0.3% of full scale |
| Meter Resolution | 1 mV, 0.01 pH |
| Titration Stability | ±1 mV / 3 h |
| Burette Resolution | 10 mL burette: 1/20000 |
| 20 mL burette | 1/10000 |
| Burette Accuracy | 10 mL: ±0.05 mL |
| 20 mL | ±0.07 mL |
| Titration Repeatability | 0.3% |
| Power Supply | AC (220 ± 22) V, (50 ± 1) Hz |
| Dimensions (W×D×H) | 340 × 400 × 400 mm |
| Weight | 10 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | ZDJ-4A |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | pH: 0.00–14.00 |
| mV | −1800.0–+1800.0 mV |
| Temperature | −5.0–105.0 °C |
| Meter Accuracy | ±0.01 pH / ±0.03% FS (mV) |
| Meter Resolution | pH: 0.01 pH |
| mV | 0.1 mV |
| Temperature | 0.1 °C |
| Stability | (±0.3 mV ±1 digit)/3 h |
| Titration Repeatability | 0.2% |
| Burette Accuracy | ±0.025 mL (10 mL burette), ±0.035 mL (20 mL burette) |
| Burette Resolution | 1/10000 (10 mL), 2/10000 (20 mL) |
| Burette Fill/Dispense Time | (55 ± 10) s (at full scale) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Dimensions (W×D×H) | 340 × 400 × 400 mm |
| Weight | 10 kg |
| [Brand | LeiCi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ZDJ-4A |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | (0.00–14.00) pH |
| Meter Accuracy | ±0.2% of full scale |
| Meter Resolution | 0.01 pH |
| Titration Accuracy | (±0.3 mV ±1 digit) / 3 h |
| Titration Resolution | 10 mL burette: 1/20,000 |
| 20 mL burette | 1/10,000 |
| Burette Error | 10 mL: ±0.025 mL |
| 20 mL | ±0.035 mL |
| Temperature Compensation Range | (−5.0–105.0) °C |
| Resolution | 0.1 °C |
| Accuracy | ±0.3 °C |
| Power Supply | AC (220 ± 22) V, (50 ± 1) Hz |
| Dimensions (W×D×H) | 340 × 400 × 400 mm |
| Weight | 10 kg] |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | ZDJ-4B |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | (0.00–14.00) pH |
| Meter Accuracy | ±0.2% of full scale |
| Meter Resolution | 0.01 pH |
| Titration Accuracy | ±0.3 mV ±1 digit over 3 h |
| Titration Resolution | 1/20,000 for 10 mL burette |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ZDJ-4B |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | (0.00–14.00) pH |
| Meter Accuracy | ±0.2% of full scale |
| Meter Resolution | 0.01 pH |
| Titration Stability | (±0.3 mV ±1 digit)/3 h |
| Titration Resolution | 10 mL burette: 1/20000 |
| 20 mL burette | 1/10000 |
| Burette Accuracy | 10 mL: ±0.025 mL |
| 20 mL | ±0.035 mL |
| Temperature Compensation Range | (−5.0–105.0) °C |
| Resolution | 0.1 °C |
| Accuracy | ±0.3 °C |
| Power Supply | AC (220 ± 22) V, (50 ± 1) Hz |
| Dimensions (W×D×H) | 340 × 400 × 400 mm |
| Weight | 10 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ZDJ-5 Coulometric Titrator |
| Price Range | USD 700 – 7,000 |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | (−1999.9 to +1999.9) mV |
| Meter Accuracy | ≤0.5% of full scale (minimum integration time: 3 s) |
| Electrolysis Current Settings | 1 mA, 10 mA, 50 mA |
| Electrolysis Current Accuracy | ±0.25% of reading (max. load: 500 Ω) |
| Repeatability in Titration | ≤0.5% (min. integration time: 3 s) |
| Power Supply | AC (220 ± 22) V, (50 ± 1) Hz |
| Dimensions (L×W×H) | 360 × 300 × 300 mm |
| Weight | 10 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ZDJ-520 |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | pH (0.00–14.00) |
| Electronic Unit Display | pH (−2.00–20.00), mV (0.0–±1999.9), Temperature (−5.0–105.0)°C |
| Electrode Unit Accuracy | ≤1.0% |
| Electrode Unit Resolution | 0.01 pH, 0.1 mV, 0.1°C |
| Repeatability (Burette Delivery) | ≤1.0% |
| pH Accuracy | ±0.01 pH ±1 digit |
| mV Accuracy | ±0.03% FS |
| Temperature Accuracy | ±0.3°C |
| Power Supply | AC (220 ± 22) V, (50 ± 1) Hz |
| Dimensions (W × D × H) | 600 × 455 × 720 mm |
| Weight | 50 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | ZDJ-5B |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | (−2000.00 to +2000.00) mV |
| Meter Accuracy | ±0.03% or ±0.2 mV (mV mode) |
| Meter Resolution | 0.01 mV |
| Titration Accuracy | 0.0003 mL |
| Titration Resolution | 1/30,000 |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | ZDJ-5B |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | (−2000.00 to +2000.00) mV, (0.000 to 20.000) pH |
| Meter Accuracy | ±0.01 mV, ±0.001 pH |
| Meter Resolution | pH: ±0.002 pH |
| mV | ±0.03% or ±0.2 mV |
| Titration Repeatability | 0.2% |
| Titration Resolution | 1/30000 |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | ZDJ-5B-D |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | mV: (−2000.00 to +2000.00) mV |
| pH | (0.000 to 20.000) pH |
| Meter Accuracy | mV: ±0.03% or ±0.2 mV |
| pH | ±0.002 pH |
| Meter Resolution | 0.01 mV, 0.001 pH |
| Titration Precision | 0.0003 mL |
| Titration Resolution | 1/30000 |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | ZDJ-5B-G Automatic Potentiometric Titrator |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | mV: (−2000.00 to +2000.00) mV |
| pH | (0.000 to 20.000) pH |
| Meter Accuracy | mV: ±0.03% or ±0.2 mV |
| pH | ±0.002 pH |
| Meter Resolution | 0.01 mV, 0.001 pH |
| Titration Precision | 0.0003 mL |
| Titration Resolution | 1/30000 |
| Brand | LeiCi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | ZDJ-5B-T |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | (−2000.00 to 2000.00) mV |
| Meter Accuracy | mV: ±0.03% or ±0.2 mV |
| pH | ±0.002 pH |
| Meter Resolution | 0.01 mV, 0.001 pH |
| Titration Precision | 0.0003 mL |
| Titration Resolution | 1/30000 |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | ZDJ-5B-Y |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | mV: (−2000.00 to +2000.00) mV |
| pH | (0.000 to 20.000) pH |
| Meter Accuracy | mV: ±0.03% FS or ±0.2 mV |
| pH | ±0.002 pH |
| Meter Resolution | 0.01 mV, 0.001 pH |
| Titration Precision | 0.0003 mL |
| Titration Resolution | 1/30000 |
| Repeatability | ≤0.2% RSD |
| Burette Error (10 mL) | ±0.020 mL |
| (20 mL) | ±0.030 mL |
| Temperature Compensation Range | −5.0 to 105.0 °C |
| Resolution | 0.1 °C |
| Accuracy | ±0.3 °C (0–60 °C), ±1.0 °C (other ranges) |
| Power Supply | AC (220 ± 22) V, 50 ± 1 Hz |
| Dimensions (W×D×H) | 340 × 400 × 400 mm |
| Weight | 8 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | ZDJ-5D |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | (-2000.00 to +2000.00) mV, (-5.000 to +20.000) pH |
| Electrode Meter Accuracy | pH: ±0.002 pH |
| pX | ±0.002 pX (pX1), ±0.005 pX (pX2) |
| Concentration | ±0.3% |
| mV | ±0.03% or ±0.2 mV |
| Electrode Meter Resolution | pH: 0.001 pH |
| pX | 0.001 pX |
| Ion Concentration | 4 significant digits |
| mV | 0.01 mV |
| Titration Repeatability | 0.2% |
| Titration Resolution | 1/480,000 |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | ZDR-2 Fully Automated Potentiometric Titrator |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Potential Measurement Range | (−2000.00 to +2000.00) mV, pH Range: (−2.000 to 20.000) |
| Potentiometer Accuracy | ±0.03% or ±0.2 mV, ±0.002 pH |
| Potentiometer Resolution | 0.01 mV, 0.001 pH |
| Titration Accuracy (10 mL burette) | ±0.020 mL |
| Titration Resolution | 1/50000 |
| Repeatability | ≤0.2% RSD |
| Temperature Measurement Range | (−5.0 to 105.0) °C, Resolution: 0.1 °C, Accuracy: ±0.3 °C (0–60 °C), ±1.0 °C (other ranges) |
| Power Supply | AC (220 ± 22) V, (50 ± 0.5) Hz |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ZDY-500 |
| Price Range | USD 700–1,400 (FOB) |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| Burette Capacity Options | 0–10 mL, 0–25 mL |
| Meter Reading Accuracy | ±0.2% of reading |
| Polarization Current Detection Error | ±2% FS |
| Repeatability of Volumetric Analysis | ±0.2% FS |
| Polarization Voltage Settings | 30 mV, 50 mV, 100 mV |
| Sensitivity Settings | 0.001 µA, 0.01 µA, 0.1 µA, 1 µA |
| Endpoint Threshold Range | 0–100 (arbitrary unit) |
| Pre-Control Point Range | 0–100 |
| Delay Time Setting | 0–200 s |
| Operating Temperature | 5–30 °C |
| Power Supply | AC 100–240 V → DC 24 V adapter |
| Dimensions (W×D×H) | 218 × 180 × 66 mm |
| Net Weight | 0.7 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | ZDY-501 |
| Pricing Range | USD 570 – 2,850 |
| Titration Mode | Fully Automatic |
| Method Type | Volumetric and Coulometric Karl Fischer |
| Moisture Measurement Range | 0.1 mg – 250 mg |
| Measurement Accuracy | ±3% |
| Polarization Current | 1 µA |
| Endpoint Detection Range | 40–120 mV |
| Sample Temperature Range | 5–30 °C |
| Dimensions (L×W×H) | 280 × 210 × 120 mm |
| Weight | 5 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | ZDY-504 |
| Pricing | USD 5,300 (FOB Shanghai) |
| Titration Mode | Fully Automatic |
| Instrument Type | Volumetric & Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 mg |
| Moisture Content Range | Volumetric: 0.1–250.0 mg H₂O |
| Coulometric | 10 µg–20 mg H₂O |
| Accuracy | Volumetric: ≤0.5% RSD |
| Coulometric | ≤3% RSD at 100 µg H₂O |
| Minimum Dispensing Volume | 0.005 mL |
| Repeatability | Volumetric: ≤0.5% RSD |
| Coulometric | ≤3% RSD at 100 µg H₂O |
| Polarization Current Settings | 10.722 mA, 20 mA, 53.61 mA, 107.22 mA |
| Burette Capacity | 10 mL |
| Titration Control Precision | 1/12,000 |
| Power Supply | (220 ± 22) V AC, (50 ± 1) Hz |
| Data Storage Capacity | 200 measurement records |
| Brand | Lengguang Tech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | F93 |
| Price Range | USD 1,400 – 7,000 |
| Dispersive Element | Holographic Grating |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Slit Width (Spectral Bandpass) | 12 nm |
| Spectral Resolution | 12 nm |
| Sensitivity | ≤1 × 10⁻⁹ mol/L (Quinine Sulfate in 0.1 M H₂SO₄) |
| Wavelength Accuracy | ±2.0 nm |
| Excitation Source | High-Stability LED |
| Brand | Lengguang Tech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Model | F96Pro |
| Wavelength Range (Excitation) | 200–850 nm |
| Wavelength Range (Emission) | 200–900 nm |
| Excitation Source | 150 W Ozone-Free Xenon Lamp (Hamamatsu, 2000 h lifetime) |
| Monochromator | Czerny-Turner grating monochromator with interference filters |
| Slit Width (Spectral Bandpass) | 10 nm |
| Spectral Resolution | 10 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | ≤0.5 nm |
| Sensitivity (S/N) | >150:1 (at water Raman peak, 350 nm excitation) |
| Scan Speed | Up to 48,000 nm/min (10-point resolution) |
| Linearity (R²) | ≥0.995 |
| Standard Excitation Filter | 365 nm interference filter |
| Software | Quantitative & qualitative analysis suite with derivative spectroscopy (1st–4th order), multi-curve overlay, kinetic time-scan, spectral math, peak integration, and calibration curve fitting (linear, quadratic, cubic) |
| Brand | Lengguang Tech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Model | F96S |
| Dispersion Element | Holographic Grating |
| Slit Width (Spectral Bandwidth) | 10 nm |
| Spectral Resolution | 10 nm |
| Sensitivity | >90:1 (Water Raman SNR) |
| Wavelength Accuracy | ±1.0 nm |
| Excitation Wavelength Range | 250–600 nm (LED-based) |
| Emission Wavelength Range | 200–650 nm |
| Emission Wavelength Repeatability | ≤0.5 nm |
| Standard Excitation Sources | 365 nm, 376 nm, 392 nm, 405 nm LEDs |
| Scan Speed | Up to 48,000 nm/min |
| Normalization Function | Fluorescence Intensity Normalization |
| Software Modes | Fluorescence Intensity & Luminescence Intensity |
| Data Processing | 1st–4th Derivative Spectra, Peak Detection, Area Integration, Multi-Curve Overlay, Ratio Analysis |
| Quantitative Methods | Calibration Curve (1st–3rd order), Coefficient Method |
| Sample Forms | Liquid, Powder, Thin Film |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory workflows, supports GLP documentation practices |
| Brand | Lengguang Tech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Product Type | Domestic |
| Model | S22 / S22PC |
| Price Range | USD 420–690 (est.) |
| Optical Design | Single-beam |
| Detector | Silicon Photocell |
| Wavelength Range | 340–1000 nm |
| Wavelength Adjustment | Manual |
| Spectral Bandwidth | 6 nm |
| Wavelength Accuracy | ±2.0 nm |
| Wavelength Repeatability | ≤1.0 nm |
| Stray Light | ≤0.2% T |
| Photometric Accuracy | ±0.5% T |
| Photometric Repeatability | ≤0.2% T |
| Absorbance Range | –0.3 to 2.999 A |
| Transmittance Range | 0.0–199.9% T |
| Dimensions | 370 × 320 × 190 mm |
| Net Weight | 7 kg |
| Brand | Lengguang Tech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop NIR Spectrometer |
| Model | S430 |
| Optical Design | Grating Scanning Monochromator |
| Wavelength Range | 900–2500 nm |
| Wavelength Accuracy | ≤0.2 nm |
| Wavelength Repeatability | ≤0.05 nm |
| Spectral Bandwidth | 8 nm |
| Stray Light | ≤0.1% |
| Absorbance Noise | ≤0.0005 Abs |
| Measurement Mode | Transmission (Cuvette-Based) |
| Scan Speed | 1 spectrum per minute |
| Data Sampling Interval | 5 s |
| Data Interface | USB 2.0 |
| Dimensions | 360 × 460 × 240 mm |
| Weight | 12 kg |
| Chemometrics Software | CAUNIRS (developed in collaboration with China Agricultural University) |