Chemical Analysis Instruments
Filter
Showing 2581–2610 of 4428 results
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | ReactIR™ 45m, ReactIR™ 45p |
| Instrument Type | In-situ, Real-time Online FTIR Spectrometer |
| Wavenumber Range | 4000–650 cm⁻¹ |
| Resolution | 4 cm⁻¹ |
| Signal-to-Noise Ratio | 2000:1 |
| Scan Speed | Not specified (typical for high-stability process-grade FTIR) |
| Probe Materials | Diamond, Silicon, Zirconia ATR crystals |
| Wetted Materials | Hastelloy®, Gold |
| Temperature Range | −80 °C to 200 °C (optional up to 300 °C) |
| Pressure Rating | Vacuum to 7 bar (optional up to 350 bar) |
| Probe Diameters | 6.35 mm, 9.5 mm, 16 mm, 25.4 mm |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DS Micro Flow Cell |
| Pricing | Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ReactRaman 802L |
| Instrument Type | Fourier Transform Raman Spectrometer |
| Spectral Range | 150–3400 cm⁻¹ |
| Spectral Resolution | 6 cm⁻¹ |
| Spatial Resolution | 2 µm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Repeatability | ±0.2 cm⁻¹ |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Rondo 12 / 15 / 20 / 30 / 60 / 60 Plus |
| Sample Capacity | 12–60 positions |
| Compatible Vessels | 80–600 mL (PE, borosilicate glass) |
| Integration Options | KF coulometric water determination, COD digestion modules, CoverUp sealing system, SU24 sample handler, Rondolino entry-level station, Liquid Handler for automated reagent/sample dispensing |
| Regulatory Compliance | Designed for GLP/GMP environments with audit trail and electronic signature support per FDA 21 CFR Part 11 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | S3, S7 |
| Portability | Portable |
| Conductivity Range | 0.000 µS/cm to 1000 mS/cm |
| TDS Range | 0.01 mg/L to 600 g/L |
| Resistivity Range | 0.00 to 100.0 MΩ·cm |
| Salinity Range | 0.00 to 42 PSU |
| Temperature Range | –5.0 to 105.0 °C |
| Accuracy | ±0.5% of reading |
| Minimum Resolution | 0.001 |
| Compliance | IP67 rated |
| Electrode Interface | ISM® (Intelligent Sensor Management) compatible |
| Display | High-contrast sunlight-readable LCD with StatusLight indicator |
| Data Transfer | IP67-rated USB port |
| Language Support | 12 languages including English, German, French, Spanish, Chinese, Japanese, Korean, etc. |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | S2, S8 |
| Instrument Type | Portable |
| Parameter Type | Single-parameter (pH/mV/Ion) |
| Measurement Range | −2.000 to 20.000 pH |
| Resolution | 0.001 / 0.01 / 0.1 pH |
| Accuracy | ±0.002 pH |
| Calibration Solution Compatibility | NIST-traceable USA-type buffers (international version) |
| Ingress Protection Rating | IP67 |
| ISM Support | Yes (InLab ISM™ smart electrode recognition) |
| Display | High-contrast sunlight-readable LCD with StatusLight indicator |
| Interface | IP67-rated USB port |
| Language Support | 12 languages including English, German, French, Spanish, Chinese, Japanese, Korean, etc. |
| Operating Environment | Lab, field, and process-line applications |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Benchtop |
| Parameter Capability | Multi-parameter |
| pH Accuracy | ±0.002 |
| pH Range | –2.000 to 20.000 |
| pH Resolution | 0.001 |
| mV Range | –2000 to +2000 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1 mV |
| Calibration Standards | NIST-traceable US standard buffer solutions |
| Ingress Protection | IP54 |
| Display | High-contrast color TFT touchscreen |
| Language Support | 12 built-in interface languages |
| Connectivity | USB-A (host & device), RS232, optional Bluetooth® module |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Benchtop |
| Measurement Modes | pH, mV, rel. mV, ORP, ion concentration (with appropriate electrode) |
| pH Range | –2.000 to 20.000 |
| Resolution | 0.001 / 0.01 / 0.1 (user-selectable) |
| Accuracy | ±0.002 pH |
| Calibration Options | 1–5 point calibration with automatic buffer recognition |
| Display | 4.3" full-color TFT touchscreen |
| Environmental Rating | IP54 |
| Language Support | 12 languages |
| Connectivity | USB-A (host), USB-B (device), RS232 (optional), Bluetooth (S230 only) |
| Compliance | Designed for GLP/GMP environments |
| Brand | METTLER TOLEDO |
|---|---|
| Model | SevenCompact™ S230 |
| Measurement Range | 0.001 µS/cm to 1000 mS/cm |
| Conductivity Accuracy | ±0.5% |
| TDS Range | 0.00 mg/L to 1000 g/L |
| Salinity Range | 0.00–80.0 psu |
| Resistivity Range | 0.00–100.0 MΩ·cm |
| Ash Conductivity (Conductivity Ash) | 0.000–2022% |
| Temperature Compensation | Automatic (ATC) or Manual (MTC), -5.0 to 130.0 °C (ATC), -30.0 to 130.0 °C (MTC) |
| Resolution | Auto-variable from 0.001 µS/cm to 1 mS/cm |
| Data Storage | 1000 GLP-compliant entries |
| IP Rating | IP54 |
| Connectivity | RS232, USB-A (for printer, flash drive, keyboard, barcode scanner, stirrer), USB-B (for PC) |
| Compliance | Supports FDA 21 CFR Part 11 audit trail via LabX Direct software (optional) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Benchtop |
| Application | Laboratory |
| Conductivity Range | 0.000 µS/cm to 2,000 mS/cm |
| TDS Range | 0.00 mg/L to 1,000 g/L |
| Resistivity Range | 0.00 to 100.0 MΩ·cm |
| Salinity Range | 0.00 to 80.00 PSU |
| Temperature Range | –30.0 to 130.0 °C |
| pH Range | –2.000 to 20.000 |
| mV Range | –2,000.0 to 2,000.0 mV |
| Ion Concentration (pX) | –2.000 to 20.000 |
| Resolution (pH/pX) | 0.001 |
| Accuracy (pH) | ±0.002 |
| Temperature Accuracy | ±0.1 °C (0–100 °C) |
| Calibration | Up to 5-point pH/ion, 1–2-point conductivity, manual or auto electrode constant determination |
| Data Storage | GLP-compliant with timestamp, sample ID, electrode ID, user ID |
| IP Rating | IP54 |
| Display | 7-inch color touchscreen |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Benchtop |
| Model | SD20 |
| Measurement Parameters | pH, mV (ORP), ref mV, Temperature |
| pH Range | –2.000 to 20.000 |
| mV Range | –2000.0 to 2000.0 |
| Temperature Range | –30.0 to 130.0 °C |
| Resolution | 0.001/0.01/0.1 pH (adjustable), 0.1/1 mV, 0.1 °C |
| Accuracy | ±0.002 pH |
| Temperature Compensation | Automatic & Manual |
| Calibration Points | Up to 5-point |
| Buffer Sets | 11 preloaded + 10 customizable |
| Endpoint Modes | Auto, Manual, Time Interval |
| Language Support | 10 languages (English, Chinese, German, French, Italian, Russian, Korean, Spanish, Portuguese, Dutch) |
| Data Storage | 2000 GLP-compliant entries with timestamp, sample ID, electrode ID, user ID |
| Connectivity | USB for PC export and printer output |
| IP Rating | IP54 |
| Display | 7-inch full-color capacitive touchscreen |
| User Management | Two-level access control (Operator/Admin) |
| Compliance | Fully GLP-compliant with audit trail-ready data logging |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Benchtop |
| Measurement Parameters | Conductivity, TDS, Resistivity, Salinity, Temperature |
| Conductivity Range | 0.000 µS/cm to 2,000 mS/cm |
| TDS Range | 0.00 mg/L to 1,000 g/L |
| Salinity Range | 0.00–80.00 psu |
| Resistivity Range | 0.00–100.0 MΩ·cm |
| Temperature Range | −30.0 to 130.0 °C |
| Resolution | Auto-ranging, up to 0.001 (conductivity), 0.1 °C (temperature) |
| Accuracy | ±0.5% of reading (conductivity), ±0.1 °C (0–100 °C) |
| Temperature Compensation | Automatic/manual |
| Calibration | Up to 2-point, auto-identification of standard solutions, built-in 13 calibration standards + 10 user-defined |
| Endpoint Modes | Auto, manual, time-based |
| Data Storage | 2,000 GLP-compliant records with timestamp, sample ID, electrode ID, operator ID |
| Connectivity | USB for data export (U-disk or PC software), optional printer interface |
| Compliance | Fully GLP-compliant |
| Enclosure Rating | IP54 (dust-protected, splash-resistant) |
| Display | 7-inch full-color capacitive touchscreen with glove-mode support |
| User Interface | 10 languages (English, Chinese, German, French, Italian, Russian, Korean, Spanish, Portuguese, Japanese) |
| Security | Dual-level user management (administrator/operator) |
| Accessories Included | InLab® 731-ISM conductivity electrode, EasyMix™ magnetic stirrer, precision electrode stand with vertical adjustment and multi-directional positioning, replaceable protective cover, corrosion-resistant sealed interface housing, pouch-packaged calibration standards |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Benchtop |
| Model | SD50 |
| Measurement Parameters | pH, mV (ORP), ref mV, Ion Concentration (pX, mol/L, mmol/L, mg/L, ppm, %), Temperature |
| pH Range | –2.000 to 20.000 |
| mV Range | –2000.0 to 2000.0 |
| Temperature Range | –30.0 to 130.0 °C |
| Ion Concentration Range | 0 to 999,999 (unit-dependent) |
| pH Resolution | 0.001/0.01/0.1 (selectable) |
| mV Resolution | 0.1 / 1 |
| Temperature Resolution | 0.1 °C |
| pH Accuracy | ±0.002 |
| mV Accuracy | ±0.1 (–500.0 to 500.0 mV) or ±0.2 (–2000.0 to 2000.0 mV) |
| Ion Accuracy | ±0.5% of reading |
| pX Accuracy | ±0.002 |
| Temperature Accuracy | ±0.1 °C (0–100 °C) |
| Calibration | Up to 5-point, auto-buffer recognition, 11 built-in buffer sets + 10 customizable sets |
| Endpoint Modes | Auto, Manual, Time Interval |
| Language Support | 10 languages (English, Chinese, German, French, Italian, Russian, Korean, Spanish, Portuguese, Japanese) |
| Data Storage | 2000 GLP-compliant records with timestamp, sample ID, electrode ID, user ID |
| Connectivity | USB (U-disk export), PC software integration |
| Enclosure Rating | IP54 |
| User Management | Dual-level access control |
| Touchscreen | 7-inch full-color capacitive display with glove-mode support |
| Accessories Included | InLab Expert Pro-ISM electrode, EasyMix™ electrode stand, buffer pouches, protective cover, corrosion-resistant interface housing |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Benchtop |
| Parameter Types | pH, mV, Ion Concentration, Conductivity, Resistivity, TDS, Salinity, Dissolved Oxygen (Polarographic & Optical), Temperature |
| pH Range | -2.000 to 20.000 |
| pH Resolution | 0.001 / 0.01 / 0.1 |
| pH Accuracy | ±0.002 |
| mV Range | -2000.0 to 2000.0 mV |
| mV Resolution | 0.1 / 1 |
| mV Accuracy | ±0.1 mV |
| Temperature Range | -30.0 to 130.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Conductivity Range | 0.001 µS/cm to 2000 mS/cm |
| Conductivity Accuracy | ±0.5% |
| Dissolved Oxygen (Polarographic) | 0.000–50 mg/L, ±0.1 mg/L (0–8 mg/L), ±0.2 mg/L (8–20 mg/L), ±10% (20–50 mg/L) |
| Dissolved Oxygen (Optical) | 0.000–99 mg/L, ±0.5% |
| Ion Concentration Range | 0–999999 mg/L or ppm |
| Ion Accuracy | ±0.5% |
| Salinity Range | 0.01–80.0 psu |
| Salinity Accuracy | ±0.5% |
| TDS Range | 0.001–1000 g/L |
| Modular Architecture | Four interchangeable measurement modules (S400 pH/mV, S500 pH/Ion, S700 Conductivity, S600/S900 DO), Three independent measurement channels |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model Range | S400 (pH/mV/ISFET), S470 (pH/mV/ISFET + Conductivity/TDS/Salinity/Resistivity/Conductivity Ash), S500 (pH/mV/Ion Concentration), S700 (Conductivity/TDS/Salinity/Resistivity/Conductivity Ash) |
| Measurement Range | –2.000 to 20.000 pH |
| Resolution | 0.001 / 0.01 / 0.1 pH |
| Accuracy | ±0.002 pH |
| mV Range | –2000.0 to +2000.0 mV |
| mV Resolution | 0.1 / 1 mV |
| mV Accuracy | ±0.1 mV |
| Conductivity Range | 0.001 µS/cm to 2000 mS/cm |
| Conductivity Accuracy | ±0.5% |
| Temperature Range (ATC/MTC) | –30.0 to 130.0 °C |
| Temperature Accuracy | ±0.1 °C |
| Data Storage | 20,000 data points, 250 analytical result sets |
| Compliance | GLP-compliant data handling, ISO/IEC 17025-ready workflows, supports 21 CFR Part 11 audit trails via LabX software |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model Series | S230 / S400 / S500 / S700 |
| Conductivity Range | 0.001 µS/cm to 2000 mS/cm |
| Conductivity Accuracy | ±0.5% of reading |
| Temperature Range | −30.0 to 130.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Resistivity Range | 0.01 to 100.0 MΩ·cm |
| TDS Range | 0.001 mg/L to 1000 g/L |
| Salinity Range | 0.00 to 80.00 PSU or ppt |
| Display | 7-inch capacitive color touchscreen |
| Connectivity | USB, RS232, Ethernet |
| Compliance | GLP, GMP, FDA 21 CFR Part 11 (with optional software configuration) |
| Calibration Support | Manual and automated (with Rondolino autosampler) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model Variants | S400 / S470 / S700 / S600 / S900 |
| Measurement Range | pH: –2.000 to 20.000 |
| mV | –2000 to +2000 |
| Resolution | pH: 0.001 |
| mV | 0.1 |
| Accuracy | ±0.002 pH (model-dependent) |
| Calibration Standards | NIST-traceable US standard buffer solutions |
| Module Configuration | Up to three interchangeable measurement modules (pH, conductivity, ion concentration, redox, dissolved oxygen) |
| Compliance | Designed for GLP/GMP environments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | SevenGo Duo |
| IP Rating | IP67 |
| Compliance | GLP-compliant data management |
| Communication | Infrared (IR) interface |
| Channel Configuration | Dual-channel simultaneous measurement |
| Measurement Modes | pH/mV/Ion Concentration, Conductivity/TDS/Salinity/Resistivity, Dissolved Oxygen (DO) |
| Display Language Support | Multilingual (including full Chinese UI) |
| Electrode Technology | ISM® Intelligent Sensor Management |
| Regulatory Alignment | Designed for ISO/IEC 17025 and FDA 21 CFR Part 11–ready environments (audit trail & user authentication enabled via optional software) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model Series | SG (pH/mV), FE (Conductivity), FG (Ion Concentration), EL (Dissolved Oxygen) |
| Instrument Type | Portable Electrochemical Analyzer |
| Compliance | ISO/IEC 17025-ready, GLP/GMP traceable data handling, IP67-rated housing |
| Software Integration | LabX direct pH (PC-based data export to Excel, CSV, PDF) |
| Electrode Interface | SmartSensor™ digital recognition & auto-configuration |
| Calibration Modes | Up to 5-point pH, up to 3-point conductivity (Kcell auto-recognition), 2-point DO (zero/saturation), multi-point ion calibration |
| Data Storage | Internal memory for ≥2000 measurement records with timestamp, operator ID, electrode ID, and environmental conditions |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | F40K |
| Instrument Type | Multifunctional Benchtop Electrochemical Analyzer |
| Parameter Types | pH, mV, rel. mV, Temperature (ATC/MTC), ISE (with optional module) |
| pH Range | -2.000 to 20.000 |
| pH Resolution | 0.001 / 0.01 / 0.1 selectable |
| pH Accuracy | ±0.001 |
| mV Range | -1999.9 to +1999.9 mV |
| mV Accuracy | ±0.1 mV |
| Temperature Compensation | Automatic (-5 to 130 °C) and Manual (-30 to 130 °C) |
| Calibration | Up to 9-point, auto-buffer recognition, 5 pre-programmed buffer sets + 1 user-defined set |
| GLP Compliance | Full audit trail, timestamped calibration & measurement records, user management |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | S40 |
| Measurement Parameters | pH (-2.000 to 19.999), mV/ORP (-1999 to +1999 mV), Conductivity (range dependent on sensor), Ion Concentration (with ion-selective electrodes) |
| pH Accuracy | ±0.002 pH |
| pH Resolution | 0.001 / 0.01 / 0.1 selectable |
| mV Accuracy | ±0.1 mV |
| Temperature Range | -30.0 to 130.0 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Display | Backlit LCD |
| Data Storage | Up to 1000 GLP-compliant measurement records and 400 GLP-compliant calibration records |
| Compliance | GLP, ISO/IEC 17025-supporting workflows, FDA 21 CFR Part 11-ready with LabX software |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | T5 |
| Titration Type | Universal Potentiometric Titrator |
| Measurement Range | ±2000 mV / –26.0 to 40.0 pH |
| Meter Accuracy | 0.01% |
| Meter Resolution | 0.1 mV / 0.001 pH |
| Titration Endpoint Precision | 0.2 mV / 0.003 pH |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | T5 / T7 / T9 |
| Measurement Range | ±2000 mV / −26.0 to +40.0 pH |
| Meter Accuracy | 0.01% |
| Meter Resolution | 0.1 mV / 0.001 pH |
| Titration Precision | 0.2 mV / 0.003 pH |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | T50 / T70 / T90 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | −2000 to +2000 mV |
| Titration Resolution | 0.1 mV |
| Electrode Interfaces | pH/mV, Conductivity, Coulometric (modular) |
| Built-in Titration Drivers | 1 internal + up to 7 external (T90) |
| Sample Capacity per Series | up to 300 samples |
| Method Storage Capacity | 100 methods |
| Communication Interfaces | Ethernet, USB Host (3×), USB Client (1×), RS-232 (COM, 3–5 ports), CAN Bus (optional) |
| Compliance | Designed for GLP/GMP environments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | T7 |
| Instrument Type | Universal Potentiometric Titrator |
| Application Scope | General-purpose |
| Measurement Range | ±2000 mV / –26.0 to 40.0 pH |
| Meter Accuracy | 0.01% |
| Meter Resolution | 0.1 mV / 0.001 pH |
| Titration Precision | 0.2 mV / 0.003 pH |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | T9 |
| Titration Type | Universal Potentiometric Titrator |
| Measurement Range | ±2000 mV / −26.0 to +40.0 pH |
| Meter Accuracy | 0.01% |
| Meter Resolution | 0.1 mV / 0.001 pH |
| Titration Precision | 0.2 mV / 0.003 pH |
| Integrated Burettes | 1 internal + 7 external |
| Parallel Titration Capability | Yes (up to 30 tasks, max 8 concurrent) |
| GLP Compliance | Yes |
| Software Logic | IF…THEN conditional method control |
| Supported Techniques | Acid-base, redox, complexometric, non-aqueous, photometric, coulometric & volumetric Karl Fischer titration |
| Auto-sampler Compatibility | InMotion™, Rondolino, Stromboli |
| Sensor Interfaces | Up to 3 sensor boards, plug-and-play sensors |
| Language Support | English, German, French, Spanish, Italian, Russian, Polish, Korean, Portuguese, Chinese |
| User Profiles | Password-protected, role-based access control |
| Connectivity | USB (printer, barcode scanner), RS-232 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | UV5, UV7 |
| Optical Design | Single-beam with pulsed xenon lamp |
| Detector | 2048-pixel CCD array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1.0 nm (UV5), ±0.8 nm (UV7) |
| Stray Light | <0.01% T at 198 nm (KCl) |
| Scan Speed | Full spectrum in ≤1 s |
| Photometric Accuracy | ±0.01 A (K₂Cr₂O₇) |
| Wavelength Resolution (toluene in n-hexane) | >1.5 nm (UV5), >1.9 nm (UV7) |
| Display | 7″ QVGA color TFT touchscreen (400 × 800 px) |
| Dimensions (L×W×H, without controller) | 208 × 255 × 228 mm |
| Weight (with controller) | 6.4 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | UV5 / UV7 / UV5Bio |
| Detector Type | CCD (Charge-Coupled Device) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.9 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | <0.03% T (at 220 nm, KI solution) |
| Automation Level | Automatic Wavelength Selection |
| Lamp Type | Xenon Flash Lamp |
| Warm-up Time | None |
| Dimensions | Compact footprint (~A4 size) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | UV5Bio / UV5Nano |
| Optical Design | Dual-wavelength |
| Detector | CCD array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1.0 nm |
| Stray Light (at 198 nm, KCl) | >2.0 A |
| Scan Time (full spectrum) | 1 s |
| Automation | Automatic wavelength selection, integrated cuvette changer, FillPalMini peristaltic pump |
| Compliance | ASTM E275, ISO 6425, USP <857>, FDA 21 CFR Part 11 ready (via LabX®) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | UV5Nano |
| Detector Type | CCD (Charge-Coupled Device) |
| Wavelength Range | 190 nm – 1,100 nm |
| Wavelength Automation | Automatic |
| Spectral Bandwidth | 1.5 nm |
| Wavelength Accuracy | ±0.9 nm |
| Stray Light | <0.03% T (at 220 nm, KI solution) |