Chemical Analysis Instruments
Filter
Showing 2611–2640 of 4426 results
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Titration Mode | Fully Automated |
| Measurement Resolution | 0.1 mV |
| Water Content Range | 10 ppm to 100% (w/w) |
| Accuracy | ±0.3% (for samples containing >10 mg H₂O) |
| Minimum Dispensing Volume | 0.05 µL |
| Titration Drive Precision | 20,000 steps per revolution |
| Compliance | Designed for GLP/GMP environments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Titration Mode | Fully Automated |
| Moisture Range | 10 ppm to 100% |
| Resolution | 0.1 µL (burette resolution) |
| One-Click Method Shortcuts | 12 (V20S), 4 (V30S), 12 (C10S), 12 (C20S), 12 (C30S) |
| Solvent Manager | Hardware-integrated, hot-pluggable |
| Smart Burette | RFID-enabled, auto-recognized |
| User Management | 4-level permission system with password protection |
| Software Integration | LabX Express / LabX Server via USB or TCP/IP |
| GLP-Compliant Printing | USB printer or METTLER TOLEDO P25 thermal printer |
| Optional Automation | InMotion KF Heated Autosampler |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Titration Mode | Fully Automatic |
| Measurement Resolution | 0.1 mV |
| Moisture Range | 10 ppm to 100% (w/w) |
| Accuracy | ±0.3% (for samples containing >10 mg H₂O) |
| Minimum Dispensing Volume | 0.05 µL |
| Titration Control Precision | 20,000 steps |
| Supported Languages | 10 (English, German, French, Italian, Spanish, Chinese, Russian, Polish, Korean, Portuguese) |
| Preloaded Methods | 11 METTLER TOLEDO Expert Methods |
| User-Defined Methods | Up to 100 |
| Task Queue Capacity | 10 tasks |
| Optional Dryer | DO308 (manual) or Stromboli (automated, 14-position) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HX204 / HS153 |
| Heating Source | Halogen Lamp |
| Maximum Sample Capacity | 200 g |
| Readability | 0.1 mg (HX204) |
| Compliance | ISO 8573-3, ASTM D4006, USP <921>, GLP/GMP-ready |
| Software | METTLER TOLEDO LabX™ (optional), One Click™ Moisture Interface |
| Cleaning Time | ≤30 s |
| Sensor Architecture | Monobloc Weighing Cell with Suspended Pan Design |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DP70 / DP90 |
| Measurement Range | ±2000 mV |
| Meter Accuracy | ±0.50% of reading |
| Meter Resolution | 0.1 mV |
| Titration Stability | ±0.2 mV over 3 h |
| Instrument Type | Universal Automatic Potentiometric Titrator |
| Compliance | Designed for ASTM E2087, ISO 8655-6, USP <541>, and GLP/GMP environments |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | MIBIscope |
| Price Range | USD 1.4M – 2.8M |
| Instrument Type | Time-of-Flight (TOF) |
| Primary Ion Beam Energy | 30 kV |
| Mass Range | >12,000 u |
| Mass Resolution | 11,000–16,000 (at m/z 150–200) |
| Brand | Micheem / BEIJING MICHEM TECHNOLOGY LTD. |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | M4000 |
| Pricing | Upon Request |
| Brand | Michell |
|---|---|
| Origin | United Kingdom |
| Model | SF52 |
| Product Type | Online Dew Point Transmitter |
| Measurement Principle | Chilled Mirror–Compensated Semiconductor Sensor |
| Operating Temperature Range | -40 to +60 °C |
| Accuracy (Dew Point) | < ±2 °C |
| Repeatability | < ±0.5 °C |
| Stability | < 1 °C/year |
| Response Time (T90) | < 10 s |
| Output Signals | 4–20 mA, 0–1 V, 0–5 V, or 0–10 V |
| Supply Voltage | 8–30 V DC (14–30 V DC required for 0–10 V output) |
| Power Consumption | 9 mA + load current |
| Supply Voltage Effect | ±0.005 %RH/V |
| Dew Point Range | -40 to +60 °C |
| Absolute Humidity Range | 0 to 200 g/m³ |
| Accuracy (Absolute Humidity) | 0.4 to 3 g/m³ (dependent on measured value) |
| Pressure Rating | Up to 20 bar (gauge) |
| Filter Type | Buffered flow-compensated sintered stainless-steel filter |
| Brand | ESI |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | microFAST Single Cell |
| Price | Upon Request |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | MicroHSImager |
| Pricing | Available Upon Request |
| Brand | Microlink / BEIJING MICHEM TECHNOLOGY LTD. |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Benchtop |
| Excitation Source | Spark |
| Detector | Scientific-grade CMOS array (replacing legacy CCD) |
| Focal Length | 1000 mm |
| Grating Density | 3600 lines/mm |
| Wavelength Range | 140 nm – 680 nm |
| Number of Simultaneous Detection Channels | 96 |
| Optical System | Dual-chamber vacuum-UV + UV-Vis configuration |
| Structural Material | Stress-relieved die-cast aluminum optical chamber (4-stage annealing) |
| Thermal Management | Active chamber temperature stabilization with laminar purge gas flow |
| Spectral Optimization | RTMC (Real-Time Multi-Channel) calibration and drift compensation algorithm |
| Compliance | Designed to support ISO/IEC 17025 workflows, ASTM E415, ASTM E1086, ASTM E3061, and GB/T 4336–2016 methodologies |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | AutoChem II 2920 |
| Temperature Range | –110 °C to 1100 °C |
| Detection Method | High-Stability TCD (Thermal Conductivity Detector) |
| Gas Inlets | 12 |
| Automated Valves | 4 × 6-port valves |
| Mass Flow Controllers | 4 (sample prep, dual carrier/reference, analysis) |
| Sample Tube | FlowThru™ quartz, rated to 1100 °C |
| TCD Zone Temperature | 150–250 °C |
| Optional Accessories | Online MS/FTIR/GC interface, vapor generator, cryogenic bath (–110 °C) |
| Software | Windows-based AutoChem software with GRAMS/32 peak processing module |
| Analytical Modes | TPD, TPR, TPO, TPRx, pulse chemisorption, isothermal reaction, BET surface area |
| Brand | ESL (Elemental Scientific Lasers) |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | MicroMill2 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | microPHAZIR AS |
| Price Range | USD 70,000–140,000 (FOB) |
| Principle | Portable, Non-Contact Reflectance NIR Spectroscopy |
| Measurement Time | <10 s |
| Sampling Mode | Non-Contact Diffuse Reflectance |
| Weight | 1.25 kg |
| Housing | Ruggedized Dust-Resistant Polymer Enclosure |
| Light Source | Tungsten-Halogen Lamp (Class 1 LED-equivalent Safety) |
| Data Interface | Internal Flash Memory + USB 2.0 Host Interface |
| Operating Temperature | 5–40 °C (non-condensing) |
| Power Supply | Dual Hot-Swappable Li-ion Batteries (4.5 h typical runtime) |
| Optional Accessories | AC Battery Charger, Carrying Case with Belt Clip |
| Brand | Microphotons |
|---|---|
| Origin | Imported |
| Manufacturer Type | OEM Manufacturer |
| Model | C3A-2700LAE |
| Pricing | Upon Request |
| Brand | MILESTONE |
|---|---|
| Origin | Italy |
| Model | DMA-1 |
| Instrument Type | Portable |
| Measurement Principle | Catalytic Thermal Decomposition – Gold Amalgamation – Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Detection Limit | ≤0.1 ng |
| Linear Range | 0–1500 ng |
| Repeatability (RSD) | ≤1.0% |
| Linearity Error | ±10% |
| Sample Throughput | 2–5 min per analysis |
| Regulatory Compliance | EPA Method 7473, HJ 923–2017, GB 5009.17–2021 |
| Brand | Milestone |
|---|---|
| Origin | Italy |
| Model | DMA-80 evo |
| Principle | Catalytic Thermal Decomposition – Gold Amalgamation – Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Detection Limit | 0.0002 ng |
| Linear Range | 0–30,000 ng |
| Repeatability (RSD) | ≤1.0% |
| Recovery Rate | >98.5% at 1000 ng |
| Compliance | EPA Method 7473, HJ 923–2017, GB 5009.17–2021 |
| Brand | GKInst |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MiniSAXS |
| Price Range | USD 140,000 – 280,000 |
| Instrument Type | Small-Angle X-ray Scattering (SAXS) System |
| Measurement Range | 1 nm – 100 nm |
| Available Anode Materials | Cu, Mo, Ag |
| Collimation | Pinhole-based collimation system |
| Filtration | Integrated beam filtration unit |
| Sample Stage | Motorized 3-axis stage with 16-position powder holder and 16-position solid-sample holder |
| Detector | Two-dimensional silicon pixel array single-photon counting detector |
| Pixel Size | 75 µm × 75 µm |
| Readout Mode | Continuous, zero dead time, no readout noise or dark current |
| Dynamic Range | 32-bit |
| Sample-to-Detector Distance (SD) | 40 mm – 350 mm |
| Scattering Vector (q) Range | 0.063 nm⁻¹ – 6.3 nm⁻¹ |
| Dimensions (W×D×H) | 840 mm × 750 mm × 700 mm |
| Power Supply | AC 220 V, 50 Hz (single-phase) |
| Supported Techniques | SAXS, WAXS, GIWAXS, GISAXS |
| Brand | MinTech |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | MT-CNE200 |
| Price | Upon Request |
| Functionality | Electrode Fabrication & Thermal Annealing |
| R<sub>G</sub> Ratio | As low as 1.1 |
| Template Material | Fused Silica Quartz |
| Tip Diameter Range | 10 nm – 50 µm (Optimized for 200–500 nm) |
| Electrode Types | Carbon Nanoelectrodes, Carbon Micronelectrodes, Carbon Nanotip Electrodes, Derivative Electrodes (Metallic Nanoelectrodes, Metal Oxide Nanoelectrodes) |
| Dimensions | 480 × 340 × 320 mm |
| Weight | ~20 kg |
| Brand | MinTech |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | MT-PSAM/IMMS100 |
| Pricing | Upon Request |
| Brand | MIPS |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIPS |
| Pricing | Available Upon Request |
| Brand | MITONG |
|---|---|
| Origin | Shanghai, China |
| Model | SYP1015-IV |
| Power Supply | AC 198–242 V, 49–51 Hz |
| Equivalent Output Voltage Range | 0–220 V |
| Heating Power | 350 W |
| Display | 3.5-digit segmented LCD |
| Control Core | 8-bit microcontroller |
| Mains Compensation | Yes (voltage-fluctuation compensation via proportional heating control) |
| Triggering Method | Zero-crossing solid-state switching |
| Compliance | GB/T 260, ASTM D95 |
| Measurement Result Format | mass percent (%) |
| Operating Environment | Ambient temperature |
| Power Consumption | 350 W |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | MS200S |
| Pricing | Available Upon Request |
| Liquid Sample Inlet Pressure Range | 0.69–2.75 MPa |
| Gas Sample Inlet Pressure Range | 0.69–2.07 MPa |
| Temperature Control Range (Heating & Trace Heating) | Ambient +5°C to 230°C |
| Temperature Stability | ±0.1°C |
| Carrier Gas Flow Rate | 0–100 mL/min |
| Flow Resolution | 0.1 mL/min |
| Operating Ambient Temperature | −18°C to +65°C |
| Surface Passivation | SilcoTek® SilcoNert®-treated Stainless Steel Tubing |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | UK |
| Model | Modulab XM PhotoEchem |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±300 mA |
| Current Accuracy | 0.1% reading + 0.05% range + 30 fA |
| Potential Accuracy | 0.1% reading + 0.05% range + 100 µV |
| Potentiostatic Range | ±8 V |
| AC Impedance Frequency Range | 10 µHz – 1 MHz |
| Brand | MOL |
|---|---|
| Origin | Germany |
| Model | CS1000 |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | Resistance Furnace |
| Carbon Range | 0.005–100 wt% |
| Sulfur Range | 0.005–20 wt% |
| Sensitivity | 0.01 ppm |
| Accuracy | ±1% of reading |
| Analysis Time | 60–120 s |
| Furnace Power Output | 1 kW |
| Maximum Furnace Temperature | 1550 °C |
| Detector Configuration | Up to 4-channel NDIR cells |
| Compliance | ASTM E1019, ISO 15350, ISO 4935 |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | QuickDrop |
| Wavelength Accuracy | ±2 nm |
| Wavelength Range | 190–1100 nm |
| Cuvette Compatibility | Yes |
| Brand | Moxtek |
|---|---|
| Origin | USA |
| Model | Monoblock |
| Tube Type | Metal-Ceramic |
| Target Materials | Ag, W, Pd, Rh |
| Operating Voltage Range | 10–50 kV |
| Current Range | 0–0.2 mA |
| Max Output Power | 10 W |
| Focal Spot Size | 400 µm |
| Stability | < 1.0% RSD |
| Beryllium Window Thickness | 0.25 mm |
| Max Input Power | 20 W |
| Operating Temperature | −10 °C to +50 °C |
| Storage Temperature | −40 °C to +60 °C |
| Weight | 500 g |
| Compliance | RoHS, CE (per IEC 61010-1), FDA 21 CFR Part 1020.40 (X-ray equipment) |
| Brand | Moxtek |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TUB00046 |
| Voltage Range | ±4–40 kV |
| Current Range | 0–100 µA |
| Max Power Output | 4 W |
| Anode Target Options | Tungsten (W), Rhodium (Rh), Copper (Cu) |
| Focal Spot Size | 300 µm |
| HV Cable Length Options | 1–11.5 inches |
| Warranty | 12 months |
| Brand | Moxtek |
|---|---|
| Origin | USA |
| Model | XPIN-BT |
| Active Area | 6 mm² or 13 mm² |
| Silicon Thickness | 625 µm |
| Beryllium Window Thickness | 8 µm or 25 µm |
| Collimator Materials | Tungsten / Cobalt / Titanium / Aluminum |
| Energy Resolution (FWHM) | < 170 eV (6 mm²), < 230 eV (13 mm²) |
| Peak-to-Background Ratio | 3600:1 @ 1 keV (6 mm², typical), 3000:1 @ 1 keV (13 mm², typical) |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | MRA-100 |
| Pricing | Upon Request |
| Wetted Materials | Stainless Steel and RPC-8™ |
| Connection | 10-32 External Thread Fittings |
| Flow Path Diameter (Stator Assembly) | 0.71 mm (0.028″) and 0.38 mm (0.015″) |
| Flow Path Volume (Per Port) | Port 1 – 2.96 µL, Port 2 – 3.76 µL, Port 3 – 0.77 µL, Port 4 – 0.46 µL |
| Max Operating Pressure | 6.9 MPa (69 bar, 1000 psi) |
| Dimensions | 19.1 cm × 14.1 cm × 7.8 cm (7.5 in × 5.6 in × 3.1 in) |
| Weight | 2.1 kg (4.6 lb) |
| Control Interface | Digital TTL Signal and RS-232 |