| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany (manufactured in Germany, distributed globally) |
| Model | ASM 340 |
| Detection Principle | Quadrupole Mass Spectrometry with Helium Carrier Gas |
| Minimum Detectable Leak Rate | ≤5 × 10⁻¹² mbar·L/s (helium) |
| Operating Mode | Positive-Pressure Sniffing & Vacuum-Coupled Testing |
| Pumping System | Integrated Turbomolecular Pump + Forepump |
| Mass Filter | 4-amu Resolution Quadrupole Analyzer |
| Response Time | <100 ms (typical) |
| Compliance | CE, RoHS, ISO 9001 Certified |
| Interface | RS-232, Ethernet, Analog Output (0–10 V) |
| Software Compatibility | Pfeiffer VacuGraph® PC Control Suite |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | ASM 340 |
| Instrument Type | Portable |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 5 × 10⁻¹³ Pa·m³/s |
| Startup Time | 3 min |
| Response Time | < 1 s |
| Maximum Inlet Pressure | 2500 Pa |
| Helium Purge Speed | 2.5 L/s |
| Leak Rate Display Range | 1 × 10⁻³ to 1 × 10⁻¹³ Pa·m³/s |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 340WET |
| Detection Principle | Helium-Specific Quadrupole Mass Spectrometry |
| Operating Mode | Vacuum (Hard-Line) Mode |
| Pumping Configuration | Integrated with ACP 28 Dry Scroll Vacuum Pump |
| Compliance | CE, RoHS, ISO 9001 Certified |
| Interface | RS-232 / Ethernet (Optional), Analog Output (0–10 V) |
| Minimum Detectable Leak Rate | ≤5 × 10⁻¹² mbar·L/s (He) |
| Response Time | < 0.5 s (typical) |
| Mass Filter | Quadrupole with 4 amu resolution at 4 He peak |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM-2000 |
| Detection Principle | Helium Mass Spectrometry (Quadrupole) |
| Measurement Methods | Vacuum Mode & Sniffer Mode |
| Quantitative Sensitivity (Vacuum Mode) | 1×10⁻⁸ – 1×10⁻⁵ mbar·L/s |
| Qualitative Sensitivity (Sniffer Mode) | >1×10⁻⁵ mbar·L/s |
| Calibration | Automatic, traceable to NIST-certified standard leak |
| Operating Temperature | 15–25 °C |
| Relative Humidity | 30–80 % RH |
| Power Supply | 90–250 V AC, 50–60 Hz |
| Typical Power Consumption | 3,750 W |
| Compressed Air (ISO 8573-1 Class 1.3.1) | 4.5–10 bar(g) |
| Helium Supply Pressure | 0.5–8 bar(g) |
| Nitrogen Supply Pressure | 0.5–8 bar(g) |
| User Interface | 10" multi-touch full-HD color display |
| Software | GMP-compliant Windows 10 OS with 4-tier user access control, PDF report generation (test, calibration, audit trail), FDA 21 CFR Part 11 readiness |
| Connectivity | 1× LAN, 2× USB 3.0, 1× HDMI |
| Dimensions (L×W×H, incl. trolley) | 1,409 × 575 × 1,194 mm |
| Weight (incl. trolley) | 140 kg |
| Acoustic Noise Level | <53 dB(A) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | OmniStar / ThermoStar |
| Principle | Quadrupole Mass Filter |
| Response Time | ≤2 s |
| Mass Range Options | 1–100 amu, 1–200 amu, 1–300 amu |
| Inlet Capillary Temperature | Up to 350 °C |
| Inlet Material | Stainless Steel (OmniStar) or Fused Silica (ThermoStar) |
| Pumping System | MVP dry diaphragm pump + HiPace turbomolecular pump |
| Software | PV MassSpec (qualitative & quantitative analysis) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HPA 220 / SPM 220 |
| Pricing | Upon Request |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | OMNISTAR™ / THERMOSTAR™ |
| Pricing | Upon Request |
| Brand | Metrohm Autolab |
|---|---|
| Origin | Netherlands |
| Manufacturer | Metrohm Autolab B.V. |
| Type | Single-Channel Potentiostat/Galvanostat |
| Max Current Output | ±100 mA |
| Current Range | 10 nA – 10 mA (7 decades) |
| Current Resolution | 30 fA (at 10 nA range) |
| Current Accuracy | ±0.2% of reading ± 0.2% of range |
| Potential Range | ±10 V |
| Applied Potential Accuracy | ±2 mV ± 0.2% of setting |
| Potential Resolution | 150 µV (applied), 3–300 µV (measured, selectable) |
| Potentiostat Bandwidth | 1 MHz |
| Rise/Fall Time (1 V step, 10–90%) | < 250 ns |
| Input Impedance | > 100 GΩ |
| Bias Current (25°C) | < 1 pA |
| Coulometric Integrator | Built-in, hardware-based |
| iR Compensation | Positive feedback and current-interrupt modes |
| Electrode Configuration | 2-, 3-, or 4-electrode |
| Analog I/O | 16-bit DAC/ADC, programmable voltage/current control and monitoring |
| Software | NOVA 2.1+ (Windows only) |
| Compliance | CE, RoHS, ISO 9001 certified design |
| Data Integrity | Audit-trail enabled in NOVA for GLP/GMP environments |
| Brand | PHI |
|---|---|
| Origin | Japan |
| Model | PHI 700 |
| Type | Scanning Auger Electron Spectrometer |
| Detection Principle | Auger Electron Spectroscopy (AES) |
| Spatial Resolution | <10 nm (beam diameter) |
| Energy Resolution | ≤0.3% at E₀ = 1 keV |
| Ion Sputtering Energy Range | 0.1–5 keV |
| Maximum Magnification | >500,000× |
| Depth Profiling Capability | Sub-nanometer to several micrometers |
| Sample Stage | High-precision motorized XYZ + tilt/rotation |
| Vacuum System | Ultra-high vacuum (UHV), base pressure ≤2×10⁻¹⁰ Torr |
| Brand | PHI |
|---|---|
| Origin | Japan |
| Model | PHI 700 |
| Type | Scanning Auger Electron Spectrometer |
| Detection Principle | Auger Electron Spectroscopy (AES) |
| Spatial Resolution | <10 nm (typical) |
| Beam Energy Range | 1–20 keV (electron gun) |
| Depth Profiling Capability | Sub-nanometer to several micrometers |
| Energy Resolution | ≤0.3% (ΔE/E at E = 1 keV) |
| Imaging Magnification | Up to 500,000× |
| Vacuum System | Ultra-High Vacuum (UHV), ≤5×10⁻¹⁰ Torr base pressure |
| Sample Stage | High-precision motorized XYZ + tilt/rotation |
| Compliance | ASTM E1508, ISO 18115-2, USP <1057>, GLP/GMP-ready data audit trail |
| Brand | ULVAC-PHI |
|---|---|
| Origin | Japan |
| Model | PHI ADEPT-1010 |
| Instrument Type | Quadrupole |
| Primary Beam Energy Range | 0.25–11 keV |
| Mass Range | 1–340 amu |
| Distribution Status | Authorized Distributor (Imported) |
| Brand | PHI |
|---|---|
| Origin | Japan |
| Model | Genesis 500 |
| Type | Fully Automated Scanning Focused XPS System |
| Sample Stage | Motorized 3-Position Carousel (80 mm × 80 mm trays) |
| Microprobe Spot Size | ≤ 5 µm |
| Depth Profiling | Integrated High-Performance Ar⁺ Ion Gun + Dual-Beam Charge Neutralization |
| Optional Techniques | UPS, LEIPS, REELS, AES, HAXPES, GCIB Sputtering |
| Software Platform | PHI SmartSoft Suite with GLP/GMP-Compliant Audit Trail & 21 CFR Part 11 Support |
| Compliance | ASTM E1521, ISO 18118, ISO 21365, USP <1057>, IEC 62304 |
| Brand | ULVAC-PHI |
|---|---|
| Origin | Japan |
| Model | PHI GENESIS 500 |
| Category | Imported Instrument |
| Distribution Status | Authorized Distributor |
| Pricing | Upon Request |
| Brand | PHI |
|---|---|
| Origin | Japan |
| Model | oTOF 3 |
| Instrument Type | Time-of-Flight (TOF) |
| Primary Beam Energy | 30 kV |
| Mass Range | 15,000 u |
| Mass Resolution | 13,500 |
| Configuration | Parallel Imaging MS/MS |
| Charge Neutralization | Dual-beam (low-energy electrons + low-energy inert gas ions), self-regulating, position-resolved |
| Optional Features | Dual-cluster ion source, sub-500 nm HR2 chemical imaging, DE-free acquisition mode, high beam current HR2 imaging, large angular acceptance & depth of field |
| Brand | PHI (Physical Electronics) |
|---|---|
| Model | TRIFT™ |
| Origin | Japan |
| Instrument Type | Time-of-Flight Secondary Ion Mass Spectrometry (TOF-SIMS) |
| Mass Analyzer | Triple-Focusing Reflectron TOF |
| Spatial Resolution | ≤ 100 nm (typical, dependent on primary ion source and sample conditions) |
| Imaging Modes | 256 × 256, 512 × 512, 1024 × 1024 pixel formats |
| Depth Profiling | Sputter-driven sequential layer removal with synchronized mass spectral acquisition |
| 3D Reconstruction | Voxel-based data integration from depth-resolved imaging stacks |
| Sample Stage Temperature Range | –150 °C to +200 °C (LN₂ cooling + resistive heating) |
| Sample Mounting Options | Back-mount (25 mm diameter), front-mount (100 mm × 100 mm planar support) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VersaProbe III |
| Price | USD 950,000 (FOB Yokohama) |
| Brand | ISOTOPX |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Phoenix |
| Instrument Type | Thermal Ionization Mass Spectrometer (TIMS) |
| Resolution | >450 |
| Dynamic Range (ATONA Amplifier) | 100 V |
| Mass Drift | <20 ppm over 40 min |
| Faraday Cup Lifetime | ≥10 years (Phoenix X62) |
| Vacuum Pumping Speed | Highest among commercial TIMS systems |
| Sample Capacity | 20-position rotatable carousel orthogonal to ion beam axis |
| Optional Detectors | Daly detector, Secondary Electron Multiplier (SEM), Multi-Collector Ion Counter with Conversion Dynode technology |
| Optional WARP Retarding Field Filter | Enables abundance sensitivity <1×10⁻⁸ for ²³⁷U/²³⁸U |
| Ion Extraction Slit | Enlarged for enhanced sensitivity |
| Focal Plane Rotation | Motorized, orthogonal to ion trajectory |
| Sample Chamber | Stainless steel with multiple auxiliary ports (pre-heating, cryo-trap, oxygen inlet) |
| Software | Fully integrated, GLP-compliant, remote operation enabled |
| Regulatory Compliance | Designed to support 21 CFR Part 11 audit trails, ISO/IEC 17025 data integrity requirements, and ASTM D7938 (TIMS-based isotope ratio analysis) |
| Brand | Auniontech (HaoLiang) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PR-1050 SpectraScan |
| Pricing | Available Upon Request |
| Brand | Photron |
|---|---|
| Origin | Australia |
| Distributor Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Photron Australia Series |
| Price Range | USD 0 – 9,999 |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PHS-3C |
| Pricing | Available Upon Request |
| Accuracy Class | 0.01 |
| pH Range | 0.00–14.00 pH |
| mV Range | ±1400 mV |
| Resolution | 0.01 pH / 1 mV / 0.1 °C |
| Temperature Compensation | 0–60 °C |
| Basic Error (pH) | ±0.1 pH |
| Input Impedance | ≥3 × 10¹¹ Ω |
| Input Current | ≤1 × 10⁻¹¹ A |
| Repeatability (pH) | ≤0.05 pH |
| Stability | ±0.05 pH ±1 digit / 3 h |
| Dimensions (L×W×H) | 220 × 160 × 65 mm |
| Weight | 0.3 kg |
| Power Supply | DC 6 V |
| Operating Environment | 5–50 °C, RH ≤85%, No Strong Vibration or Magnetic Interference |
| Brand | PHXTEC |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | AA68 A |
| Instrument Type | Flame AAS |
| Monochromator Element | Plane Grating |
| Optical System | Single-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal Method |
| Spectral Resolution | 0.1 nm |
| Sensitivity | >0.3 A (for Cu 0.5 µg/mL) |
| Repeatability (RSD) | ≤0.5% |
| Detection Limit | 0.003 µg/mL (for Cu) |
| Baseline Stability | ≤0.002 A / 30 min |
| Brand | PhysTech |
|---|---|
| Origin | Germany |
| Model | FT1030 |
| Instrument Type | Deep-Level Transient Spectroscopy System |
| Operating Modes | C-DLTS, CC-DLTS, I-DLTS, DD-DLTS, Zerbst-DLTS, O-DLTS, FET-Analysis, MOS-Analysis, ITS, PITS, TSC/TSCAP, DLOS, C/V(T), I/V(T), Richardson Plot, Capture Cross-Section Analysis |
| Key Software Features | 28 simultaneous correlation functions per temperature scan, Fourier-DLTS (F-DLTS), Laplace-DLTS, multi-exponential transient fitting, isothermal transient spectroscopy (ITS), signal overlap deconvolution (temperature-scan & isothermal), automatic contact check, real-time capacitance compensation, three-terminal FET current transient acquisition |
| Cooling Compatibility | Liquid nitrogen, closed-cycle cryocoolers, and programmable temperature controllers (4 K – 500 K typical range) |
| Compliance | Designed for GLP/GMP-aligned semiconductor defect characterization workflows |
| Brand | Picarro |
|---|---|
| Origin | USA |
| Model | G2132-i |
| Measurement Principle | Cavity Ring-Down Spectroscopy (CRDS) |
| δ¹³C Precision (1σ, 1-hour average) | < 0.4‰ at [CH₄] > 10 ppm |
| δ¹³C Drift (24 h, 1-hr avg) | < 1.5‰ at [CH₄] = 10 ppm |
| CH₄ Concentration Precision (30 s, 1σ) | 1 ppb + 0.05% of ¹³CH₄ reading |
| CH₄ Dynamic Range | 1.8–1500 ppm (operational) |
| CO₂ Range | 100–4000 ppm |
| H₂O Range | 0–5% RH |
| Sample Temp. | –10 to 45 °C |
| Sample Pressure | 300–1000 Torr (40–133 kPa) |
| Flow Rate | ≤25 sccm (at 760 Torr) |
| Temperature Stability | ±0.005 °C |
| Pressure Stability | ±0.0002 atm |
| Environmental Operating Range | 10–35 °C, <99% RH (non-condensing) |
| Data Interfaces | RS-232, Ethernet, USB, analog (0–10 V) |
| Dimensions (Analyzer) | 43.2 × 17.8 × 44.6 cm |
| Weight | 27.4 kg (incl. external pump) |
| Brand | Picarro |
|---|---|
| Origin | USA |
| Model | G2201-i |
| Instrument Type | Stable Gas Isotope Ratio Analyzer |
| Measurement Precision | δ¹³C-CO₂ < 0.12‰ (1σ, 1 hr), δ¹³C-CO₂/δ¹³C-CH₄ dual-species mode < 0.16‰ (1σ, 1 hr) |
| Measured Species | CO₂, CH₄, H₂O |
| Operating Principle | Cavity Ring-Down Spectroscopy (CRDS) |
| Temperature Stability | ±0.005 °C (cavity) |
| Pressure Stability | ±0.0002 atm (cavity) |
| Sample Flow Rate | < 50 sccm (typ. 25 sccm at 760 Torr) |
| Dimensions | 43.2 × 17.8 × 44.6 cm (W×H×D) |
| Weight | 25.4 kg (incl. external pump) |
| Brand | Pickering Laboratories |
|---|---|
| Origin | USA |
| Model | PINNACLE PCX DELTA |
| Temperature Range | Ambient to 150 °C (programmable, ±1 °C stability) |
| Derivatization Reagent Flow Rate | 0.01–2.0 mL/min (precision ±0.5% RSD) |
| Reaction Coil Options | PEEK, FEP, or stainless steel (0.25–1.0 mm ID, 1–30 m length) |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Brand | Pickering |
|---|---|
| Origin | USA |
| Model | Onyx PCX |
| Temperature Range | 5 °C to 130 °C (ambient +5 °C) |
| Derivatization Reagent Flow Rate | 50 µL/min – 1500 µL/min |
| Reaction Coil Volume | 0.1–3 mL |
| Brand | Pickering |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Onyx |
| Instrument Type | Post-Column Derivatization System |
| Derivatization Chemistry | Ninhydrin-based (Trione® reagent) |
| Detection Mode | Visible Absorbance (570 nm & 440 nm) |
| Compatible HPLC Platforms | Standard UV/Vis-equipped HPLC systems |
| Amino Acid Coverage | Up to 50 free amino acids |
| Typical Detection Sensitivity | ≤10 pmol (ninhydrin), ≤2 pmol (OPA alternative) |
| Resolution | ≥1.5 for Leu/Ile, ≥1.2 for all other standard amino acids |
| Equilibration Time | 9 min |
| Run Time | 30 min (hydrolysates), 70 min (free amino acids) |
| Reagent Stability | Trione® ninhydrin reagent exhibits enhanced thermal and oxidative stability vs. conventional ninhydrin solutions |
| Brand | Pickering |
|---|---|
| Origin | USA |
| Model | Vector PCX |
| Temperature Range | 5 °C – 130 °C |
| Derivatization Reagent Flow Rate | 0.05 – 2.0 mL/min |
| Reaction Coil Volume | 0.1 – 3.0 mL |
| Construction | PEEK Fluidic Path |
| Flow Control | Electronic, Pulse-Free |
| Safety | Integrated Leak Detection, Over-Temperature & Over-Pressure Protection |
| Compliance | Designed for GLP/GMP environments |
| Brand | LABA (Tianjin Lanbo) |
|---|---|
| Origin | France |
| Model Series | PICLab 100 / 150 / 200 / 600 / 1000 |
| Instrument Type | Preparative SFC System |
| Detector Options | DAD, UV-Vis, Mass Spectrometer (MS) |
| Maximum Operating Pressure | 350 bar |
| CO₂ Flow Rate Range | 10–1000 mL/min |
| Application Modes | Analytical, Semi-Preparative (up to 100 g), and Preparative (gram-to-kilogram scale) |
| CO₂ Recycling Capability | Standard on PICLab 150 and above |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | PIKE |
|---|---|
| Origin | USA |
| Model | 160-1900 |
| Type | Laboratory-Scale IR Sample Preparation Accessory |
| Material | Hardened Stainless Steel |
| Sample Diameter | 13 mm |
| Vacuum Interface | Standard Negative-Pressure Port |
| Includes | Stainless Steel Base with Vacuum Port, 13 mm Die Cavity, Two Polished Pressure Anvils, Precision-Machined Plunger, Two O-Rings (for Plunger Seal and Base Mounting) |
| Surface Finish | Mirror-Polished Contact Surfaces |
| Compliance | Designed for ASTM E1252 and USP <1119> FTIR Sample Preparation Protocols |