Chemical Analysis Instruments
Filter
Showing 2791–2820 of 10680 results
| Brand | EPROI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SiriusT3 |
| Price Range | USD 280–425 |
| Brand | STT |
|---|---|
| Origin | Beijing, China |
| Manufacturer | STT Senfu Technology |
| Model | EQ STT-5000 |
| Detection Limit | 0.1 ppb for benzene (0.0003 mg/m³) |
| Weight | 2.2 kg |
| Dimensions | 267 × 197 × 308 mm |
| Column | MEMS-based microfabricated capillary column |
| Detector | 10.6 eV Photoionization Detector (PID) |
| Measurement Range | 0.1–300 ppb (low-range mode) or 50 ppb–10 ppm (high-range mode) for benzene |
| Accuracy | ±1% FS |
| Carrier Gas | Ambient air (filtered via activated carbon + molecular sieve) |
| Battery Life | >9 h |
| Analysis Time | ≤10 min per sample |
| Compliance | GB/T 18883–2022 Annex C.3, EPA Method 5035, EPA Method 8021 |
| Brand | Eraly & Associés |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HELIOS CL |
| Price | Upon Request |
| Measurement Principle | Coulometric Titration (Absolute Method) |
| Sample Types | Liquids (including viscous), Gases (incl. LPG), Solids, Slurries, Polymers, Fuels, Environmental Matrices |
| Compliance | ASTM D4929, ASTM D5808, ASTM D5194, ASTM D6721, GB/T 18612, SH/T 1757, GB/T 23971-B, SH/T 0677-A, UOP 779, ISO 9562, NF EN 12260, NF EN 14077 |
| Detection Range | 0.1 ppm to 80 wt% Cl (matrix-dependent, no dilution required) |
| Electrolyte Options | Three grades for low-, medium-, and high-concentration applications |
| Dual-Cell Architecture | Two independent coulometric titration cells |
| Furnace | F2-type high-temperature combustion furnace, max. 1100 °C |
| Carrier Gases | O₂ (99.998%, 3 bar) and Ar (99.995%, 3 bar) |
| Sample Introduction | 20–80 µL liquid |
| Power Supply | 110/230 V, 50/60 Hz, 800 W |
| Dimensions (W×H×D) | 66 × 83 × 56 cm |
| Weight | 32 kg |
| Warranty | 5-year hardware warranty |
| Language Interface | English, French, Spanish, German, Russian, Chinese |
| Safety Features | Automated acid-free dry/wash system, light-shielded semi-pressurized titration cell, integrated gas flow control and pressure monitoring |
| Brand | Eraly & Associés |
|---|---|
| Origin | France |
| Model | HELIOS N |
| Measurement Element | Nitrogen |
| Measurement Principle | Chemiluminescence Detection |
| Detection Limit | 5 ppb |
| Quantitation Range | 10 ppb – 10 % |
| Furnace Temperature Range | Up to 1100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Volume | 20–80 µL (liquid), 10 mL (gas), 20 µL (LPG) |
| Carrier Gases | O₂ (99.998%, 3 bar), Ar (99.995%, 3 bar) |
| Power Supply | 110/230 V, 50/60 Hz, 800 W |
| Dimensions (W×H×D) | 51 × 78 × 56 cm |
| Weight | 32 kg |
| Brand | Eraly & Associés |
|---|---|
| Origin | France |
| Model | HELIOS S |
| Measurement Element | Sulfur |
| Measurement Principle | Ultraviolet Fluorescence (UVF) |
| Detection Limit | 5 ppb |
| Quantitation Limit | 10 ppb |
| Measurement Range | 5 ppb – 10% w/w |
| Combustion Furnace Temperature | Up to 1100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Volume | 20–80 µL (liquid), 10 mL (gas), 20 µL (LPG) |
| Gas Requirements | O₂ ≥99.998% at 3 bar, Ar ≥99.995% at 3 bar |
| Power Supply | 110/230 V, 50/60 Hz, 800 W |
| Dimensions (W×H×D) | 51 × 78 × 56 cm |
| Weight | 32 kg |
| Brand | Eraly & Associés |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HELIOS S&N |
| Measurement Elements | Sulfur (S), Nitrogen (N) |
| Measurement Principle | UV Fluorescence (S) / Chemiluminescence (N) |
| Detection Limit | 5 ppb (S), 5 ppb–10% (N) |
| Quantitation Range | 10 ppb–10% (S & N) |
| Furnace Temperature Range | Up to 1100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Volume | 20–80 µL (liquid), 10 mL (gas), 20 µL (LPG) |
| Carrier Gases | O₂ (99.998%, 3 bar), Ar (99.995%, 3 bar) |
| Display | 7-inch touchscreen interface |
| Languages | English, French, Spanish, German, Russian, Chinese |
| Compliance | ASTM D5453, D6667, D7183, D7551, D4629, D6069, D5762 |
| Brand | Eraly & Associés |
|---|---|
| Origin | France |
| Model | HELIOS SN&CL |
| Measurement Elements | Sulfur (S), Nitrogen (N), Chlorine (Cl) |
| Measurement Principles | UV Fluorescence (S), Chemiluminescence (N), Coulometric Titration (Cl) |
| Detection Limits | 5 ppb (S), 5 ppb–10% (N), 50 ppb–80+% (Cl) |
| Quantitation Ranges | 10 ppb–100 ppm (S), 10 ppb N–10% (N), <0.1 ppm–80+% (Cl) |
| Combustion Furnace Temperature | Up to 1100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Volume | 20–80 µL (liquid), 10 mL (gas), 20 µL (LPG) |
| Carrier Gases | O₂ (99.998%, 3 bar), Ar (99.995%, 3 bar) |
| Built-in Languages | English, French, Spanish, German, Russian, Chinese |
| Brand | ERALYTICS |
|---|---|
| Origin | France |
| Model | SulfUV |
| Measurement Principle | UV Fluorescence Detection of SO₂ |
| Heating System | High-Frequency Combustion Furnace (1000 °C) |
| Measurement Range | 10 ppb – ~10 wt% S |
| Sensitivity | 0.001 ppm |
| Accuracy | ±0.05 ppm at 0.5 ppm |
| Analysis Time | 5 min (liquids/gases), 5–10 min (solids) |
| Sample Introduction | Liquid (20–100 µL syringe), Gas/LPG (1–10 mL via gas injector), Solid (0.5–100 mg in sample boat) |
| Dimensions | 80 cm × 55 cm × 30 cm (L×H×D) |
| Weight | 35 kg |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERAOIL |
| Type | Rotating Disk Electrode Optical Emission Spectrometer (RDE-OES) |
| Detection Principle | Arc Spark Optical Emission Spectrometry |
| Measurement Time | ≤30 s per sample |
| Elements Quantified | Up to 32 metallic elements |
| Detection Limit (LOD) | Sub-ppm for most elements (standard configuration) |
| Sample Types | Lubricants, fuels, coolants, process water, hydraulic fluids |
| Compliance | ASTM D6728, ASTM D6595, NB/SH/T 0865 |
| Integrated System | Built-in 10-inch color touchscreen, embedded industrial PC, automated electrode dresser, and active ventilation unit |
| Dimensions & Portability | Compact benchtop footprint |
| Sample Preparation | None required — direct liquid analysis |
| Gas Requirement | None (no carrier gas, no plasma gas) |
| Brand | ESI |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CS995 |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | 20 MHz High-Frequency Induction Furnace |
| Power Output | 2200 W |
| Carbon Range | 0.00006–6.0000 wt% (extendable to 99.999%) |
| Sulfur Range | 0.00006–0.5000 wt% (extendable to 99.999%) |
| Sensitivity | 0.001 ppm for both C and S |
| Precision | RSD < 0.5% |
| Compliant with GB/T 20123–2006 and ISO 15350 | 2000 |
| Analysis Time | 20–100 s (typical: 35 s) |
| Sample Mass (steel standard) | 0.5 g nominal |
| Dust Filter Pore Size | 0.4 µm metallic sintered filter |
| Optical Path | Gold-plated CO₂/SO₂ absorption cells |
| IR Source | Platinum-based thermal emitter (800 °C operating temperature) |
| Detection Wavelengths | CO₂ at 4.26 µm, SO₂ at 7.4 µm |
| Modulation Frequency | 64 Hz |
| Data Acquisition | 24-bit ADS1224 ADC, 20 Hz real-time sampling |
| Communication | USB 2.0 host interface + Agilent 1521/2521 optical fiber link between furnace and detector |
| Software Platform | Windows-based Delphi application with ACCESS database backend |
| Brand | ESI |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | EdibleOil ICP |
| Pricing | Available Upon Request |
| Brand | ESI |
|---|---|
| Model | EDX9000A |
| Element Range | Na (11) – U (92) |
| Detection Limit | 1 ppm |
| Quantification Range | 1 ppm – 99.99 wt% |
| Excitation Source | 50 W Rh-target X-ray tube, 0–50 kV |
| Detector | AmpTek high-resolution silicon drift detector (SDD) |
| DPP Analyzer | 4096-channel digital pulse processor |
| Sample Chamber Dimensions | 460 × 310 × 95 mm |
| Vacuum Chamber | Φ150 mm × 75 mm |
| Instrument Dimensions | 560 × 380 × 410 mm |
| Weight | 45 kg |
| Operating Environment | −10 °C to 35 °C |
| Power Supply | 220 V AC, 50/60 Hz |
| Brand | ESI |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | EDX9000B PLUS |
| Configuration | Benchtop/Floor-standing |
| Industry-Specific Application | Non-Ferrous Metals |
| Elemental Range | Na (Z=11) to U (Z=92) |
| Quantification Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV (Mn Kα) |
| Repeatability (RSD) | ≤0.05% |
| Detector | Peltier-Cooled Fast Silicon Drift Detector (FSDD) |
| Brand | ESI/ESL |
|---|---|
| Origin | France |
| Manufacturer | ESL (Elemental Scientific Lasers) |
| Type | Imported |
| Model | ESL193HE |
| Pricing | Upon Request |
| Brand | ESS |
|---|---|
| Origin | United Kingdom |
| Model | Ecosys-P |
| Power Supply | 100–240 V AC, 170 W |
| Battery | 24 V DC, 8 h continuous operation |
| I/O Ports | 4 analog outputs, 2 analog inputs, 2 digital inputs, 2 digital outputs |
| Detection Limit | sub-ppt (parts-per-quadrillion) for selected VOCs |
| Sample Introduction | Integrated thermal desorption unit with long-distance sampling capability |
| Operational Mode | Fully autonomous, unattended field deployment |
| Data Handling | Per-point data file generation, automated reporting, optional auto-calibration |
| Brand | EST |
|---|---|
| Origin | USA |
| Model | Centurion |
| Sample Positions | 100 |
| Injection Precision | RSD < 3% |
| Trap Tube Temperature Range | Ambient to 280 °C |
| Purge Sample Heating Temperature | Ambient to 120 °C |
| Sample Vial Cooling Temperature | 4–10 °C |
| Brand | SOC/SurfaceOptics |
|---|---|
| Origin | USA |
| Model | ET100 |
| Measurement Principle | Integrating Sphere-Based Reflectance Method |
| Imaging Mode | 3D Surface-Referenced Optical Sampling |
| Operating State | Ground-Based Field & Lab Use |
| Spectral Bands | 6 Non-Contiguous IR Bands (1.5–2, 2–3.5, 3–4, 4–5, 5–10.5, 10.5–21 µm) |
| Incidence Angles | 20° and 60° (relative to surface normal) |
| Measurement Type | Directional-Hemispherical Reflectance (DHR), converted to spectral and broadband emissivity |
| Measurement Time | ≤7 s per acquisition (after 90 s IR source stabilization) |
| Sample Geometry Support | Flat, convex (≥6″ radius), concave (≥12″ radius) surfaces |
| Power Supply | Dual Rechargeable NiMH Batteries |
| Operating Temperature | 0–40 °C (non-condensing) |
| Storage Temperature | −25–70 °C |
| Weight | 2.1 kg (inclusive of batteries) |
| Compliance | ASTM E408-22, NIST-Traceable Calibration Available |
| Data Storage | Internal SD card with timestamped reflectance/emissivity records |
| Brand | EuroVector |
|---|---|
| Origin | Italy |
| Model | EA3017 |
| Analysis Principle | Dumas Combustion Method |
| Automation Level | Fully Automated Nitrogen Determinator |
| Nitrogen Range | 0–100% |
| Repeatability | ±0.5% RSD |
| Sample Mass Capacity | ≤5 g (solid) |
| Dimensions (L×W×H) | 480 mm × 480 mm × 600 mm |
| Brand | EuroVector |
|---|---|
| Origin | Italy |
| Model | EA3100 |
| Measurable Elements | C, H, N, S, O |
| Analysis Time | CN ≤ 3 min |
| Detection Limit | ppm-level |
| Measurement Accuracy | ±0.1% (relative) |
| Sample Introduction | Tin or silver capsules, filled to capacity |
| Detector Type | Thermal Conductivity Detector (TCD) |
| Combustion Temperature | TurboFlash dynamic combustion up to 1800 °C |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Eutech CON2700 |
| Price | Upon Request |
| Measured Parameter | Conductivity (Single-Parameter) |
| Form Factor | Benchtop |
| Conductivity Range | 0.050 μS/cm to 500.0 mS/cm |
| TDS Range | 0.050 ppm to 500 ppt (at TDS factor = 1.00) |
| Resistivity Range | 2.000 Ω to 20.0 MΩ |
| Salinity Range | 0–80 ppt |
| Temperature Range | 0.0–100.0 °C |
| Accuracy | ±1% of full scale |
| Minimum Resolution | 0.01 / 0.1 μS/cm |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Eutech Instruments (a Thermo Fisher brand) |
| Type | Imported |
| Model | COND 6+ |
| Price | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Eutech Instruments (a Thermo Fisher brand) |
| Model | pH110 |
| pH Range | -2.00 to 16.00 |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.01 pH |
| Calibration Points | Up to 6-point, auto-buffer recognition (USA, NIST, DIN, PWB) |
| ORP Range | ±1999.0 mV |
| ORP Resolution | 0.1 mV (±199.9 mV), 1 mV (>±199.9 mV) |
| ORP Accuracy | ±0.2 mV / ±2 mV ±1 LSD |
| Temperature Range | -10.0 to 110.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Compensation | Auto/manual (0.0–100.0 °C) |
| Data Storage | 100 measurement sets + calibration records |
| Display | Dual-line LCD (5.8 × 3.3 cm) |
| Interface | BNC, 2.5 mm phono, DC socket, RS232C |
| Power | 4 × 1.5 V AA alkaline batteries (life >700 h) or 9 V regulated adapter (200 mA) |
| Dimensions (instrument) | 18 × 9 × 4 cm |
| Weight (instrument) | 220 g |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Eutech Instruments (a Thermo Fisher brand) |
| Model | pH510 |
| Type | Benchtop Electrochemical Meter |
| Compliance | CE, RoHS, IP54 |
| Calibration | Up to 5-point, auto-buffer recognition (USA/NIST) |
| pH Range | 0.00–14.00 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.01 pH |
| Temperature Range | 0.0–100.0 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.3 °C |
| ORP/mV Range | ±1999 mV |
| mV Resolution | 0.1 mV (≤±199.9 mV), 1 mV (>±199.9 mV) |
| mV Accuracy | ±0.2 mV (≤±199.9 mV), ±2 mV (>±199.9 mV) |
| Temperature Compensation | Auto/manual (0–100 °C) |
| Data Storage | 100 readings with timestamp & temperature |
| Display | LCD (5.9 × 3.2 cm) |
| Input | BNC pH input, phono ATC input, DC socket |
| Output | Analog recorder output (0–1 V or 0–20 mA configurable) |
| Power | 9 V DC regulated adapter (100–220 VAC, linear supply) |
| Dimensions (H×W×D) | 23 × 18 × 6 cm |
| Weight | 750 g (unit), 1100 g (packaged) |
| Operating Environment | 0–50 °C, ≤85% RH non-condensing |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Eutech Instruments (a Thermo Fisher brand) |
| Model | pH6500 |
| Type | Dual-Channel Benchtop Electrochemical Analyzer |
| Measurement Modes | pH, mV (ORP/RmV), Ion Concentration (ISE), Temperature |
| pH Range | –2.000 to 20.000 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.002 pH + 1 LSD (at 25 °C) |
| Ion Range | 1×10⁻⁶ to 9.99×10¹⁰ ppm |
| Ion Accuracy | ±0.17% of full scale (monovalent), ±0.34% (divalent) |
| ORP/RmV Range | ±2000.0 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±0.2 mV |
| Temperature Range | –5.0 to 105.0 °C |
| Temp. Accuracy | ±0.2 °C |
| Calibration Points | up to 5-point pH, 2–5-point ISE |
| Buffer Recognition | USA, NIST, Euro, Custom |
| Temperature Compensation | Auto/Manual (0.0–100.0 °C) |
| GLP Compliance | Yes |
| Data Storage | 1000 entries with timestamp, electrode ID, calibration history |
| Display | 11.43 × 15.24 cm (4.5 × 6 in) Windows CE–based color touchscreen |
| Connectivity | USB host/device, RS232, IrDA, RJ45 Ethernet, SD card slot, BNC, DIN, phono inputs |
| Power | 9 V DC, 3.3 A (100–240 VAC SMPS) |
| Dimensions (W×D×H) | 16.5 × 23.5 × 8.9 cm |
| Weight | 1.1 kg |
| Brand | Eutech |
|---|---|
| Origin | USA |
| Model | ORPTEST10 |
| Instrument Type | Laboratory & Field-Portable ORP Meter |
| Measurement Range | −999 to +1000 mV |
| Resolution | 1 mV |
| Accuracy | ±2 mV |
| Calibration | Manual 1-point |
| Electrode Type | Replaceable Double-Junction Ag/AgCl |
| Power Supply | 4 × A76/LR44 batteries |
| Battery Life | >500 hours |
| Auto-Off | 8.5 min idle |
| Operating Temperature | 5–45 °C |
| IP Rating | IP67 |
| Display | Dual-line LCD (2.1 × 2.7 cm) |
| Dimensions | 16.5 × 3.8 cm |
| Weight | 90 g |
| Data Hold & Low-Battery Indication | Yes |
| Temperature Compensation | None (ORP-only measurement) |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Eutech PH2700 |
| Instrument Type | Benchtop |
| Parameter Types | Dual (pH + ORP) |
| pH Measurement Range | -2.000 to 20.000 pH |
| pH Resolution | 0.1 / 0.01 / 0.001 pH |
| pH Accuracy | ±0.002 pH + 1 LSD |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| ORP/mV Range | ±2000.0 mV |
| ORP/mV Resolution | 0.1 mV |
| ORP/mV Accuracy | ±0.2 mV |
| Calibration Points | Up to 6-point, auto-buffer recognition (USA, NIST, DIN, User 1, User 2, Custom) |
| Electrode Diagnostics | Slope & Offset Display |
| Data Storage | 500 GLP-compliant entries with timestamp |
| Temperature Compensation | Automatic or Manual (0–100 °C) |
| Display | Backlit LCD (5.9 × 7.8 cm) |
| Connectivity | BNC (pH/ORP), Phono (ATC probe), Phono (Reference), RS232C output |
| Power | 9 V DC regulated adapter (100–240 VAC SMPS) |
| Dimensions (W×D×H) | 17.5 × 15.5 × 6.9 cm |
| Weight | 650 g (unit only) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer | Eutech Instruments (a Thermo Fisher Scientific brand) |
| Type | Portable Multi-parameter Electrochemical Analyzer |
| Model | pH450 |
| Measurement Range | –2.00 to 16.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Points | Up to 5 (USA/NIST), up to 6 (DIN), or up to 5 user-defined points |
| Buffer Recognition | Automatic (USA/NIST/DIN) |
| Calibration Expiry Alert | Configurable |
| Data Storage | 500 datasets with timestamp (RTC) |
| Connectivity | USB and RS232 |
| Power | 2 × AA batteries (typical life >2000 hours) or optional AC adapter |
| Enclosure Rating | IP67 |
| Electrode Interface | BNC |
| Temperature Unit | °C/°F selectable |
| GLP Compliance | Yes (time-stamped calibration & measurement records) |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Eutech pH700 |
| Instrument Type | Benchtop |
| Parameter Channels | Dual (pH + ORP) |
| pH Range | -2.00 to 16.00 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.01 pH + 1 LSD |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| ORP/mV Range | ±2000 mV |
| ORP Resolution | 0.1 mV (within ±199.9 mV), 1 mV (elsewhere) |
| ORP Accuracy | 0.1 mV (within ±199.9 mV), 1 mV (elsewhere) |
| Calibration Points | Up to 5-point pH calibration |
| Buffer Standards | USA and NIST traceable |
| Temperature Compensation | Automatic or Manual (0–100 °C, pH only) |
| Data Storage | 100 measurement records |
| GLP Compliance | Yes (slope/offset display, timestamped calibration logs) |
| Display | Dual-line LCD (5.6 × 7.5 cm) |
| Input Interfaces | BNC (pH/ORP), Phono (ATC probe), Phono (reference electrode), DC socket |
| Power Supply | 9 V DC regulated adapter (100–240 VAC SMPS) |
| Dimensions (W×D×H) | 17.5 × 15.5 × 6.9 cm |
| Weight | 650 g (instrument only) |