Chemical Analysis Instruments
Filter
Showing 2761–2790 of 10680 results
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Model | 1152 |
| Measurement Range | 0–1999 pS/m |
| Resolution | 1 pS/m |
| Probe Type | Removable Stainless Steel Electrode |
| Display | LCD |
| Design | Portable, Field- and Lab-Compatible |
| Compliance | ASTM D2624, GB/T 6539 |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | 1154 |
| Detection Parameter | Single (Conductivity) |
| Portability | Benchtop |
| Application Environment | Laboratory |
| Conductivity Range | 0–20,000 pS/m |
| Accuracy | ±½% of reading |
| Minimum Resolution | 0.01 pS/m |
| Brand | Endress+Hauser |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RAMAN RXN HYBRID |
| Instrument Type | Grating-Based Raman Spectrometer |
| Excitation Wavelength | 785 nm |
| Probe Compatibility | Rxn-20 Solid-Phase Probe + Secondary E+H Raman Probe |
| Hazardous Area Certifications | ATEX, IECEx, North America (Class I Div 1/2, Class II Div 1) |
| Installation Options | Benchtop, Mobile Cart, or In-Line Process Skid Mounting |
| Sample Phase Support | Simultaneous Solid & Liquid Analysis Channels |
| Spatial Sampling Flexibility | Micron- to Millimeter-Scale Spot Sizes (up to 6 mm diameter) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | PQMS Elite |
| Instrument Type | Quadrupole ICP-MS |
| Sensitivity (7Li) | >90 Mcps/mg·L⁻¹ |
| Sensitivity (115In) | >1500 Mcps/mg·L⁻¹ |
| Sensitivity (232Th) | >1000 Mcps/mg·L⁻¹ |
| Vacuum System | Dual 300 L/s Turbo Molecular Pumps + High-Capacity Rotary Vane Pump |
| Typical Analysis Cycle Time to Operational Vacuum | <5 min |
| Base Pressure | 1×10⁻⁸–1×10⁻⁹ mbar |
| Brand | Dongxi Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Multi-Channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Peristaltic Pump |
| Detectable Elements | As, Sb, Bi, Se, Sn, Pb, Ge, Te, Zn, Cd, Hg |
| Relative Standard Deviation (RSD) | <1.0% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | As, Sb, Se, Pb, Sn, Bi, Te < 0.01 ng |
| Brand | Dongxi Analytical |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Concave Grating (1800 lines/mm) |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Self-Absorption Method |
| Resolution | <0.2 nm |
| Sensitivity | Cu 0.015 µg/mL (Flame), Cd 0.5 pg (Graphite Furnace) |
| Repeatability (RSD) | Flame RSD ≤0.6% (Cu), Graphite Furnace RSD ≤2% (Cd) |
| Detection Limit | Flame: 0.002–0.005 mg/L (e.g., Cu) |
| Graphite Furnace | 0.1–5 pg (e.g., Cd, Pb, As) |
| Brand | Dongxi Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | EL-100 |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength | 450 nm (blue LED) |
| Detection Method | Photomultiplier Tube (PMT) |
| Light Source | High-Stability Blue LED |
| Evaporation Zone Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±1 °C |
| Solvent Flow Rate Compatibility | 10 µL/min – 3 mL/min |
| Nebulizing Gas Flow Rate | 300 mL/min – 1.5 L/min |
| Nebulizing Gas Pressure | 0.2–0.5 MPa |
| Detection Limit | <1 ng (glucose, direct injection) |
| Baseline Noise | <0.1 mV (at 1 mL/min mobile phase flow) |
| Dimensions (W×D×H) | 165 × 470 × 580 mm |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | MIA-4 |
| Instrument Type | Mercaptan Sulfur & Basic Nitrogen Analyzer |
| Measurement Range | ≥3 µg/g |
| Potentiometric Range | 0 to ±1999.9 mV, Resolution: 0.1 mV |
| Accuracy | ±0.025% of reading + 2 digits |
| Input Impedance | ≥1 × 10¹² Ω |
| Burette Capacity | 10 mL, Minimum Dispensing Volume: 0.01 mL |
| Relative Error | ≤5% |
| Repeatability | Compliant with GB/T 1792 and ASTM D3227 |
| Dimensions (W×D×H) | 240 × 120 × 210 mm |
| Weight | 5 kg |
| Power Consumption | ≤10 W |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petroleum & Petrochemical Industry |
| Oven Temperature Range | 8 °C to 400 °C (above ambient) |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cooling Time | ≤4 min (from 400 °C to 50 °C) |
| Carrier Gas Flow Range | 0–100 mL/min |
| Carrier Gas Pressure Range | 0–250 kPa |
| Injector Max Temp | 300 °C |
| Injector Pressure Setpoint Range | 0–250 kPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| FID Detection Limit | ≤5×10⁻¹² g/s (n-C₁₆ in iso-octane) |
| FID Baseline Noise (packed column) | <10×10⁻¹⁴ A |
| FID Baseline Drift (packed column, 30 min) | <6×10⁻¹³ A |
| Column Oven Stability at 70 °C | <0.5% RSD |
| Temperature Display Resolution | 0.1 °C |
| Programmable Temperature Ramping | 8-step, min increment 0.1 °C/min |
| Repeatability (50–250 °C at 10 °C/min) | ≤1% RSD |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | High-Purity Gas Analysis |
| Oven Temperature Range | Ambient + 3 °C to 450 °C |
| Maximum Ramp Rate | 120 °C/min (adjustable in 0.1 °C/min increments) |
| Cooling Rate | 350 °C → 50 °C in ≤5 min (with motorized rear door) |
| Carrier Gas Pressure Control Range | 0–100 psi (0–689 kPa) |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Inlet Temperature Max | 300 °C |
| Inlet Pressure Setting Range | 0–100 psi |
| Electronic Pressure/Flow Control (EPC/EFC) Precision | ±0.001 psi / ±0.001 mL/min |
| Temperature Stability | ±0.1% of setpoint |
| Temperature Display Resolution | 0.01 °C |
| Programmable Temperature Steps | Up to 16 stages (expandable to unlimited via firmware) |
| Retention Time RSD | <0.008% |
| Peak Area RSD | <1.0% |
| Power Supply | 220 V ±10%, 50 Hz ±5% |
| Dimensions (W×D×H) | 570 × 570 × 506 mm |
| Weight | ≤55 kg |
| Max Power Consumption | ≤3000 W |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | GC910 |
| Price | USD 2,800 (FOB Shanghai) |
| Brand | Jinpu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-7890 Touchscreen |
| Application Field | Environmental Monitoring & Food & Beverage Quality Control |
| Column Oven Temperature Range | +5 °C to 450 °C (0.1 °C increments) |
| Temperature Accuracy | ±0.1 °C |
| Max Heating Rate | 40 °C/min |
| Cooling Capability | Down to –80 °C with cryogenic coolant (dry ice or liquid nitrogen) |
| Detector Options | Dual FID, Dual TCD, FID+TCD, plus ECD, NPD, FPD |
| Simultaneous Column Configuration | Two packed columns + one capillary column, or two capillary columns |
| Independent Injector & Detector Zones | Six temperature-controlled zones |
| Programmed Temperature Ramping | Up to 7 steps |
| Power Supply | AC 220 V ±10%, 50 Hz, 2.2 kW |
| Dimensions | 660 × 460 × 465 mm |
| Weight | 60 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | RLTD-05 / RLTD-10 |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | AA-7090 |
| Price Range | USD 4,200–7,000 (FOB) |
| Instrument Type | Flame and Graphite Furnace AAS (Parallel Configuration) |
| Monochromator | Holographic Grating |
| Optical System | Dual-Beam |
| Detector | Solid-State CCD Array |
| Background Correction | Automatic D₂ and Transverse AC Zeeman |
| Magnetic Field Strength | 0.6–1.1 T (0.1 T Adjustable Steps) |
| Lamp Turret | 8-Position Motorized |
| Lamp Recognition | Encoded Hollow Cathode Lamp Support |
| Graphite Furnace Imaging | Integrated Visual Monitoring System |
| Gas Control | Dual-Path Programmable Gas Supply (Main + Auxiliary) |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Domestic (China-Made) |
| Model | SP6900 GC + JK-01 Auto-Headspace Sampler |
| Price Range | USD 7,000–14,000 |
| Primary Application | Residual Solvent Testing in Pharmaceutical APIs and Finished Dosage Forms |
| Detection Methods | Static Headspace GC-FID/TCD |
| Compliant With | USP <467>, ICH Q3C(R8), EP 2.4.24, ISO/IEC 17025 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | AA-7000 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating (1800 lines/mm) |
| Optical System | Double-Beam |
| Detector Type | Solid-State Photodiode Array |
| Background Correction | D₂ Lamp + Self-Reversal (Self-Absorption) Method |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1 / 0.2 / 0.4 / 1.0 / 2.0 nm (motorized switching) |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ≤±0.1 nm |
| Static Baseline Stability | ≤±0.002 A/30 min |
| Dynamic Baseline Stability | ≤±0.004 A/30 min |
| Resolution | <0.3 nm |
| Cu Characteristic Concentration (Flame) | ≤0.02 µg/mL |
| Cu Detection Limit (Flame) | ≤0.005 µg/mL |
| RSD (Flame) | ≤1% |
| Atomizer Options | 50 mm & 100 mm Interchangeable Titanium Burner Heads |
| Graphite Furnace Power Supply | Integrated (4 kW) |
| Dimensions (W×D×H) | 880 × 540 × 450 mm |
| Weight | 125 kg |
| Power Supply | 220 V, 50 Hz, Single Phase (Host: 200 W |
| GF Module | 4 kW) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EST |
| Instrument Type | Water & Soil VOC Analysis |
| Sample Tray Capacity | 84 positions |
| Injection Precision | RSD ≤ 10% |
| Trap Temperature Range | 180–300 °C |
| Purge Sample Heating Temperature | Ambient to 90 °C |
| Vial Cooling Temperature | 4–10 °C |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | PM8202 I |
| Measurement Range | 0.00–20,000 ppm Ca²⁺ |
| Resolution | 0.0 / 0.1 / 1 ppm (selectable) |
| Accuracy | ±0.01 / ±0.1 / ±1 ppm (depending on range) |
| Temperature Compensation | –10 to 130 °C (manual or automatic |
| Operating Temperature | –10 to 70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Display | Backlit large-dot-matrix LCD |
| Language Support | English & Chinese |
| Data Storage Capacity | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Analog Outputs | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS, configurable for hardness or temperature) |
| Enclosure Rating | IP67-rated sealed housing |
| Electrode | BSENS740 calcium-selective electrode (solid-state, polymer membrane) |
| Origin | United Kingdom |
|---|---|
| Distribution Model | Authorized Distributor |
| Import Status | Imported |
| Model | sCMOS_4MP |
| Pricing | Available Upon Request |
| Active Area (Single Module) | 22.5 × 22.5 mm to 95.5 × 95.5 mm |
| Multi-Module Array Configurations | 134 × 134 mm, 268 × 67 mm, 191 × 191 mm, 382 × 95.5 mm |
| Scintillator Options | Gd₂O₂S:Tb (1–55 keV), CsI:Tl (20–300 keV) |
| Pixel Array | 2048 × 2048 |
| Pixel Size | 11 × 11 µm |
| Full-Well Capacity | 80,000 e⁻ |
| Read Noise | 1.8 e⁻ rms |
| Dark Current | <1 e⁻/pixel/s |
| Quantum Efficiency (Peak) | 58% @ scintillator emission wavelength (no microlens) |
| Exposure Time Range | 50 µs – 60 s |
| Operating Sensor Temperature | −20 °C (water-cooled) |
| Bit Depth | 16-bit |
| Dynamic Range | 20,000:1 |
| Spatial Resolution | Gd₂O₂S:Tb — 25 lp/mm |
| CsI | Tl — 20 lp/mm |
| Frame Rate | 18 fps (full frame), 4.5 fps (full frame, no binning) |
| Interface | Gigabit Ethernet / GenICam-compliant |
| Brand | Zhongjiaojinyuan |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ICA-3000 |
| Pricing | Upon Request |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | WAHS-20A Plus |
| Sample Positions | 20 |
| Heating Range (Sample/Valve/Transfer Line) | 40–220 °C (configurable up to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | <±0.5 °C |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Purge Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Pressurization Pressure | 0–0.25 MPa (continuously adjustable) |
| Quantitative Loop Volume | 1 mL (customizable: 0.5/2/5 mL) |
| Vial Capacity | 10 mL or 20 mL (customizable: 50/100 mL) |
| Simultaneous Heating | 1 or 2 vials |
| RSD | <1.0% (100 ppm ethanol in water) |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Interface | USB |
| Compliance | ASTM D6866, ISO 17025-compatible operation, GLP/GMP-ready audit trail via software logging |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-9860III |
| Temperature Control Range | Ambient to 400 °C |
| Maximum Ramp Rate | 40 °C/min |
| Cooling Rate | 40 °C/min |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–970 kPa |
| Injector Maximum Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Region of Origin | Domestic (China) |
| Model | ALHS-20A PLUS |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Sample Capacity | 20 positions |
| Compatible Vial Sizes | 10 mL or 20 mL |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CMH-01 |
| Application | Laboratory-grade dew point measurement |
| Principle | Chilled-mirror hygrometry |
| Operating Temperature | 0–50 °C |
| Accuracy | ±0.2 °C dew point |
| Repeatability | ±0.1 °C dew point |
| Measurement Range (at 101.3 kPa) | −70 to +20 °C dew point (dependent on ambient temperature) |
| Cooling Capacity | >95 °C differential (4-stage Peltier) |
| Gas Flow Rate | 15–60 L/h (typical: 25–30 L/h) |
| Sample Pressure Range | 1 kPa–1 MPa |
| Display | 320×240 true-color TFT LCD |
| Power Supply | 20 V DC / 6.0 A (host) |
| Battery Life | >8 h continuous operation |
| Dimensions | 320 × 330 × 150 mm |
| Weight | ~4 kg |
| Brand | HSPX |
|---|---|
| Origin | China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Pharmaceutical Residue Analysis |
| Temperature Control Range | Ambient +5°C to 400°C |
| Oven Ramp Rate | 0.1–39.9°C/min |
| Cool-down Time | ~6 min (from 400°C to 50°C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | ModuLab XM ECS |
| Instrument Type | Electrochemical Workstation |
| Channel Configuration | Multi-Channel Expandable Architecture |
| Current Range | ±2 A to ±100 A |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of reading |
| Potentiostatic Range | ±100 V |
| AC Impedance Frequency Range | 10 µHz to 1 MHz |
| Origin | Shandong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | AA-7020 |
| Price Range | USD 7,000–14,000 (FOB) |
| Instrument Type | Dual-Mode Flame/Graphite Furnace AAS |
| Monochromator | Plane Grating (1800 lines/mm) |
| Optical System | Single-Beam Czerny-Turner |
| Detector | Solid-State Photomultiplier Tube (Hamamatsu R928) |
| Background Correction | Deuterium Lamp + Self-Reversal (Auto-Adjusting) |
| Spectral Resolution | ≤0.3 nm |
| Cu Sensitivity (Flame) | ≥0.3 A at 5 ppm |
| Relative Standard Deviation (RSD) | ≤0.3% (Flame), ≤1% (Graphite Furnace) |
| Detection Limit (Flame) | ≤0.003 µg/mL (Cu) |
| (Graphite Furnace) | ≤0.5×10⁻¹³ g (Cd) |
| Brand | ENSOUL |
|---|---|
| Model | MHSS-2 |
| Sample Positions | 2 |
| Heating Temperature Range | Ambient to 100 °C |
| Temperature Accuracy | ±3 °C |
| Timer Range | 0–999 min |
| Power Supply | AC 220 V |
| Power Consumption | 420 W |
| Compatibility | PEN-series electronic nose systems |
| Application | Headspace volatile profiling for sensory intelligent analysis |
| Brand | ENSOUL |
|---|---|
| Model | MHSS-9 |
| Sample Positions | 9 |
| Heating Temperature Range | Ambient to 100 °C |
| Temperature Accuracy | ±0.1 °C |
| Power Supply | AC 220 V |
| Power Consumption | 650 W |
| Compatibility | PEN-series electronic nose instruments |
| Origin | Beijing, China |
| Brand | EONTECH |
|---|---|
| Origin | Beijing, China |
| Model | MT 1000 |
| Measurement Principle | Electrolytic Method |
| Operating Temperature | -10°C to +50°C |
| Accuracy | ±1% of full scale |
| Range Options | 0–10 / 0–100 / 0–1000 / 0–2500 ppm (user-selectable) |
| Resolution | 0.1 ppm |
| Display | Touchscreen LCD |
| Alarm Outputs | 2 relay outputs |
| Analog Output | 4–20 mA |
| Power Supply | 220 VAC, 50–60 Hz + internal rechargeable Li-ion battery |
| Power Consumption | 8 W |
| Enclosure Rating | IP65 |
| Dimensions (Analyzer) | 340 × 290 × 220 mm |
| Weight (Analyzer) | ~3 kg |
| Sensor Model | TMS-H/P/100 |
| Sensor Housing Material | Hastelloy |
| Electrode Material | Platinum |
| Electrolyte | Phosphoric acid (H₃PO₄) membrane |
| Sample Flow Rate | 100 NL/h |
| Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | +5°C to +150°C (recommended ≤50°C) |
| Sensor Response Time (T₅₀) | <8 s |
| Detection Limit | 0.1 ppm |
| Sealing Material | FEP |
| Gas Fitting | 6 mm compression fitting |
| Cable Length | Standard 3 m (up to 300 m optional) |
| Electrical Connector | LEMO waterproof |
| Sensor Mounting | Vertical via three M4 screws |
| Sensor Dimensions | Ø43 × 120 mm |
| Sensor Weight | ~1.15 kg |