Chemical Analysis Instruments
Filter
Showing 2941–2970 of 4337 results
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop Ion Chromatograph |
| Application Scope | Universal (Anions & Cations) |
| Maximum Pump Pressure | 0–42.0 MPa (Stainless Steel), 0–36 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max System Operating Pressure | 10 MPa (1500 psi) |
| Column Oven Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.004 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | PIC-20 |
| Instrument Type | Laboratory Benchtop |
| Application Scope | General-Purpose Ion Analysis |
| Pump Maximum Pressure | 0–42.0 MPa (stainless steel), 0–35 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min (adjustable in 0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| System Operating Pressure Limit | 10 MPa (1500 psi) |
| Column Oven Temperature Range | 5–65 °C |
| Temperature Stability | ±0.004 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Model | PIC-20 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Class | Laboratory Benchtop Ion Chromatograph |
| Application Scope | General-Purpose Anion/Cation Analysis |
| Maximum Pump Pressure | 0–36.0 MPa |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max Operating Pressure | 10 MPa (1500 psi) |
| Operating Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.1 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Detector Configuration | Dual Conductivity Detectors + Optional Amperometric Detector |
| Column Oven | Integrated Peltier-heated Column/Suppressor Compartment (Patent No. ZL200820019630.3) |
| Data Storage | Local SSD + Cloud Synchronization |
| Connectivity | USB 2.0, Wi-Fi, Mobile App Remote Control (iOS/Android) |
| Compliance | Designed for ISO/IEC 17025 environments |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | PIC-30 |
| Instrument Type | Laboratory Benchtop System |
| Application Scope | General-Purpose Anion/Cation Analysis |
| Maximum Pump Pressure | 36 MPa |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Operating Pressure | 10 MPa |
| Operating Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.04 °C |
| Eluent Concentration Range | 0–20 mM |
| Detector Options | Dual-Channel Conductivity Detector / Single-Channel Voltammetric Detector / Dual-Channel UV-Vis Detector |
| Fluidic Path | All-PEEK Non-Metallic Flow Path |
| Integrated Components | Embedded Chromatography Workstation, Auto-Sampler Interface, Onboard Dilution Module, Eluent Generator Compatibility (Optional), Internal Degasser, CO₂ Suppressor, Column Oven with Integrated Conductivity Cell & Suppressor |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable Ion Chromatograph |
| Model | PIC-60 |
| Pump Pressure Rating | 42 MPa |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Operating Temperature Range | 0–65 °C |
| Temperature Reproducibility | ±0.01 °C |
| Eluent Concentration Range | 0–80 mmol/L |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | PIC-80 |
| Instrument Type | Laboratory Benchtop |
| Application Scope | General-Purpose |
| Pump Max Pressure | 0–42.0 MPa (Stainless Steel) / 0–36 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Maximum Operating Pressure | 10 MPa (1500 psi) |
| Operating Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.004 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | PIC-80B |
| Instrument Type | Laboratory |
| Application Scope | General-purpose |
| Pump Pressure Rating | 0–42.0 MPa (stainless steel), 0–36 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max Operating Pressure | 10 MPa |
| Operating Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.004 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Online Analyzer |
| Application | General-Purpose Environmental & Industrial Process Monitoring |
| Pump Pressure Rating | 0–42.0 MPa (Stainless Steel) / 0–35 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max Operating Pressure | 10 MPa (1500 psi) |
| Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.1 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Mini β |
| Pricing | Available Upon Request |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Model | puriFlash® Active Splitter |
| Flow Path Architecture | Active Valve-Based Splitting |
| Split Ratio Control | Software-Defined Switching Frequency |
| Pressure Management | Zero Backpressure Generation |
| Compatibility | Interchim puriFlash® Systems & All Interchim HPLC/UHPLC Columns |
| Detection Integration | Simultaneous UV + MS Trigger Logic |
| Software Control | Intersoft® X Platform (FDA 21 CFR Part 11 Compliant Audit Trail Optional) |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | PuriMaster-3500C1 |
| Application Level | Laboratory-grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Pump Pressure Rating | 300 bar |
| Flow Rate Range | 0–50 mL/min per pump |
| Flow Stability | ≤2% RSD |
| UV-Vis Detection Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Detector Light Source | Dual-lamp system (Deuterium + Tungsten) |
| Fraction Collection | 6-port switching valve (standard) |
| Auto-sampler Quantitative Loop | 3 mL |
| Gradient Capability | Binary high-pressure mixing |
| Brand | Purkinje |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC1100 |
| Temperature Control Range | Ambient +6°C to 399°C |
| Oven Ramp Rate | 0–30°C/min |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–970 kPa |
| Injector Maximum Temperature | 200°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Column Oven Temperature Accuracy | ±0.1°C |
| Column Oven Temperature Gradient | ±1.5% |
| TCD Sensitivity | ≥4000 mV·mL/mg (n-hexadecane) |
| TCD Noise | ≤0.04 mV |
| TCD Baseline Drift | ≤0.2 mV/30 min |
| FID Detection Limit | ≤8×10⁻¹² g/s (n-hexadecane) |
| FID Noise | ≤0.02 mV |
| FID Baseline Drift | ≤0.2 mV/30 min |
| Dimensions (L×W×H) | 562×550×492.5 mm |
| Weight | 44 kg |
| Brand | Purkinje |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 185–900 nm |
| Wavelength Accuracy | ±0.1 nm (at D₂ line, 656.1 nm) |
| Wavelength Repeatability | ≤0.05 nm (at D₂ line, 656.1 nm) |
| Spectral Bandwidth | Continuously Adjustable from 0.1 to 5.0 nm |
| Stray Light | ≤0.00004%T (NaI, 220 nm) |
| Stray Light | ≤0.00002%T (NaNO₂, 360 nm) |
| Photometric Range | –8 to +8 Abs |
| Baseline Flatness | ±0.0005 Abs |
| Photometric Accuracy | ±0.002 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs), ±0.3%T (>1.0 Abs) |
| Photometric Repeatability | ≤0.001 Abs (0–0.5 Abs), ≤0.002 Abs (0.5–1.0 Abs), ≤0.1%T (>1.0 Abs) |
| Drift | ≤0.1%T/h |
| Brand | Purkinje |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TU-1901 / TU-1900 |
| Optical System | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190 nm – 900 nm |
| Wavelength Accuracy | ±0.3 nm (auto-calibrated at startup) |
| Wavelength Repeatability | ≤0.15 nm |
| Spectral Bandwidth | 0.1 nm, 0.2 nm, 0.5 nm, 1.0 nm, 2.0 nm, 5.0 nm |
| Stray Light | ≤0.01%T at 220 nm (NaI), ≤0.05%T at 360 nm (NaNO₂) |
| Photometric Accuracy | ±0.002 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs), ±0.3%T (0–100%T) |
| Photometric Range | –4.0 to +4.0 Abs |
| Baseline Flatness | ±0.001 Abs |
| Baseline Drift | 0.0004 Abs/h (at 500 nm, 0 Abs, after 2 h warm-up) |
| Photometric Noise | ±0.0004 Abs |
| Brand | Purkinje |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ±0.3 nm (auto-calibrated at startup) |
| Wavelength Repeatability | ≤0.15 nm |
| Spectral Bandwidth | Continuously Variable from 0.1 to 5.0 nm (0.1 nm increments) |
| Stray Light | ≤0.01% T at 220 nm (NaI), ≤0.05% T at 360 nm (NaNO₂) |
| Baseline Flatness | ±0.001 Abs |
| Drift | ≤0.1%/h |
| Dimensions | 610 × 570 × 300 mm |
| Weight | 39 kg |
| Brand | PUSH |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Model | PS-3003 |
| Measurement Range | pH 3.8–7.0 |
| Minimum Display Resolution | 0.1 pH unit |
| Temperature Control Accuracy | ±2 °C |
| Measurement Accuracy | ≤ ±0.1 pH |
| Operating Environment | 5–45 °C, ≤85% RH, AC 220 V ±10%, 50 Hz ±1 Hz |
| Sample Throughput | 1–3 samples per run |
| Interface | USB for PC connectivity |
| Compliance | Designed per GB/T 7598–2008 (Determination of Water-Soluble Acids in In-Service Transformer Oil) |
| Brand | Pyreos |
|---|---|
| Origin | United Kingdom |
| Model | PYR-TP Series (Thin-Film PZT) |
| Detector Material | Lead Zirconate Titanate (PZT) Ferroelectric Film |
| Film Thickness | 1 µm |
| Spectral Range | 1.2–20 µm |
| Detectivity (D*) | >1 × 10⁹ cm·√Hz/W @ 10 Hz (typ.), ~3.5 × 10⁸ cm·√Hz/W @ 10 Hz (1 mm × 1 mm element) |
| Responsivity | Up to 150,000 V/W @ 500 K, 10 Hz |
| Noise Equivalent Power (NEP) | ~0.4 mV·√Hz/W |
| Response Time | <5 ms (bandwidth up to 3.3 kHz) |
| Curie Temperature | ~600 °C |
| Operating Temperature Range | –40 °C to +85 °C (uncooled) |
| Pixel Configurations | Single-point, 128×1, 128×2, 512×1 linear arrays |
| Active Area Options | 150 µm × 150 µm to 3 mm × 2 mm |
| Filter Integration | Optional integrated linear variable filters (LVF) for NIR: 1.3–3.2 µm |
| MIR/FIR | 2–20 µm |
| Compliance | RoHS, REACH, ISO 9001-manufactured |
| Brand | LABA (Tianjin Lanbo) |
|---|---|
| Origin | USA |
| Model | Q-Grad |
| Pump Type | Quaternary High-Pressure Gradient Pump |
| Flow Range | 1 µL/min – 20 mL/min |
| Gradient Composition | Up to 4 Solvents, Independently Controlled |
| Mixing Architecture | High-Pressure Binary/Quaternary Blending (No Low-Pressure Mixer or Online Degasser Required) |
| Dead Volume | Minimized via Integrated Direct High-Pressure Mixing |
| Bubble-Free Operation | Achieved through Positive-Displacement Plunger Design and Solvent Compressibility Compensation |
| Brand | Ocean Insight |
|---|---|
| Origin | USA |
| Detector Type | Back-Illuminated CCD |
| Spectral Range | Configurable from 185–1100 nm |
| Resolution | 18-bit ADC |
| Peak Quantum Efficiency | 90% |
| Signal-to-Noise Ratio | 1000:1 (full well, single acquisition) |
| Dynamic Range | 85,000 (typical, at full well capacity) |
| Stray Light | <0.08% at 600 nm |
| Cooling | Thermoelectrically cooled to –15 °C (stabilized ±0.1 °C) |
| Onboard Memory | 15,000 spectra buffer |
| Interface | USB 2.0 / USB 3.0 compatible |
| Slit Options | 5–200 µm (interchangeable) |
| Grating Options | Multiple groove densities and blaze wavelengths available |
| Internal Shutter | Optional for dark current optimization |
| Brand | Qilin (QL) |
|---|---|
| Model | BS1000G |
| Origin | Jiangsu, China |
| Type | Benchtop Photometric Elemental Analyzer |
| Optical System | Adjustable-Wavelength Self-Collimating Diffraction Grating (Right-Exit) |
| Wavelength Accuracy | ±3 nm |
| Measurable Elements (typical) | Mn (0.10–65.00 wt%), Si (0.10–75.00 wt%), P (0.005–1.00 wt%), Cu (0.02–85.00 wt%), Cr (0.01–45.00 wt%), Ni (0.01–50.00 wt%), Mo (0.101–6.00 wt%), Mg (0.010–0.100 wt%), Rare Earths (0.01–0.100 wt%) |
| Analytical Method | Photometric Colorimetry with Computer-Controlled Wavelength Selection |
| Measurement Time per Sample | ≤5 s |
| Weighing Device | 0.0001 g Precision Electronic Balance (1/10,000 g resolution) |
| Compliance | GB/T 223 series (Chinese national standards for metallurgical analysis) |
| Operating Environment | 10–30 °C, RH <75% |
| Data Output | Integrated thermal printer (Chinese-language interface), PC-based data logging |
| Brand | Qilin / QL |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QL-BS3B |
| Price | USD 1,380 (FOB Nanjing) |
| Measurement Principle | Photometric Colorimetry with Cold Light Sources |
| Elements Measured | Si, Mn, P, Ni, Cr, Cu, Rare Earths, Mg, Fe, Al, V, W, Ti |
| Typical Range (w/w) | Mn 0.10–15.00%, Si 0.10–5.00%, P 0.005–0.80%, Cr 0.010–25.0%, Mo 0.010–6.00%, Mg 0.010–0.99% |
| Detection Method | Dual-beam photometry using imported silicon photodiodes |
| Calibration | Automatic zero & full-scale self-calibration |
| Curve Storage | 15 user-programmable calibration curves |
| Input Interface | Touch-sensitive membrane keypad with audible feedback |
| Sample Preparation | External fusion (crucible-based), valve-free and tubing-free design |
| Optical Source | Interchangeable cold-light sources for spectral adaptability |
| Brand | QL |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HW2000B |
| Price | USD 13,800 (FOB Nanjing) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | 2.5 kVA High-Frequency Induction Furnace (18–20 MHz) |
| Carbon Range | 0.00001–10.0000 wt% (extendable to 99.999 wt%) |
| Sulfur Range | 0.00001–0.5000 wt% (extendable to 99.999 wt%) |
| Sensitivity | 0.1 ppm (minimum display resolution) |
| Precision | Carbon RSD ≤ 0.5% |
| Analysis Time | 25–60 s (user-adjustable) |
| Compliance | GB/T 20123–2006, ISO 15350:2000 |
| Weighing Accuracy | 0.0001 g (external analytical balance required) |
| Optical Detection | High-stability pyroelectric IR detectors with narrow-band interference filters |
| Gas Handling | Precision mass flow control |
| Mechanical Drive | Aerospace-grade synchronous motor in IR absorption cell (MTBF > 100,000 h) |
| Compensation | Real-time temperature, pressure, and flow compensation algorithms |
| Brand | Qilin (QL) |
|---|---|
| Model | QL-BS1000 |
| Origin | Jiangsu, China |
| Wavelength Range | 400–800 nm (continuously adjustable) |
| Absorbance Range | 0–1.999 A |
| Concentration Display Range | 0.000–99.99% (auto-ranging) |
| Wavelength Accuracy | ±3 nm |
| Data Storage | Onboard EEPROM (retains data for ≥10 years without power) |
| Power Supply | AC 220 V ±10%, 50 Hz ±5% |
| Power Consumption | ≤45 W |
| Net Weight | ≤15 kg |
| Display | 1-inch numeric LED display |
| Calibration | Auto-zero and full-scale calibration using cold light source and imported photodetectors |
| Curve Storage | Up to 9 pre-programmed calibration curves |
| Sample Handling | External dissolution |
| Optical System | Adjustable-wavelength monochromatic light source with microprocessor-controlled spectral selection |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | QL-HW2000B |
| Measurement Principle | Infrared Absorption Spectroscopy |
| Heating System | 2.5 kVA High-Frequency Induction Furnace (18–20 MHz) |
| Carbon Range | 0.00001–10.0000 wt% (extendable to 99.999 wt%) |
| Sulfur Range | 0.00001–0.5000 wt% (extendable to 99.999 wt%) |
| Sensitivity | 0.1 ppm (minimum display resolution) |
| Precision | Carbon RSD ≤ 0.5%, Sulfur RSD ≤ 1.0% |
| Analysis Time | 25–60 s (user-adjustable) |
| Compliance | GB/T 20123–2006, ISO 15350:2000 |
| Sample Weighing Accuracy | 0.0001 g |
| Detector Type | High-Stability Pyroelectric Infrared Detector with Narrow-Band Interference Filters |
| Gas Control | Precision Mass Flow Controllers + Airtac (Taiwan) Solenoid Valves (rated for ≥100,000 cycles) |
| Optical Drive | Aerospace-Grade Synchronous Motor (MTBF > 100,000 h) |
| Brand | Qilin |
|---|---|
| Model | TS-3 |
| Origin | Jiangsu, China |
| Measurement Time | 240 s |
| CE Range | 3.2–4.8 wt% (±0.1%) |
| C Range | 2.8–4.2 wt% (±0.05%) |
| Si Range | 0.9–3.0 wt% (±0.08%) |
| Display Height | 50 mm |
| Temperature Compensation | 0–40 °C |
| Cup Types | S, R, B, K |
| Compliance | EN 50081-2, EN 50082-2 |
| Temperature Unit | Selectable (°C/°F) |
| Status Indicators | Green (Ready), Yellow (Measuring), Red (Complete) |
| Brand | Qilin / QL |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | QL-TS-6 |
| Price Range | USD 2,800 – 7,000 |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | QL-TS-6 |
| Measurement Principle | Thermal Analysis (Solidification Curve Monitoring via Immersion Thermocouple) |
| Measurement Time | ≤90 s per sample |
| CE Range | 3.2–4.8 wt%, ±0.08 wt% accuracy |
| C Range | 2.8–4.2 wt%, ±0.04 wt% accuracy |
| Si Range | 0.9–3.0 wt%, ±0.04 wt% accuracy |
| Data Storage Capacity | 3,000 measurements with timestamped sequence |
| Output Interface | USB flash drive export optional |
| Compliance | Designed for foundry floor deployment under ISO 9001 and ASTM E1157 (Standard Practice for Sampling and Testing Cast Iron) environments |
| Operating Environment | Industrial-grade embedded PC with fanless motherboard, 17″ ruggedized LCD display, EMI-hardened signal acquisition architecture |
| Brand | RADOM |
|---|---|
| Model | Altair / Mira / Sirius |
| Origin | Imported |
| Plasma Gas Compatibility | Air, N₂, CO₂, H₂, H₂O vapor |
| Max. Plasma Temperature | >5500 °C (Altair/Mira), >6000 °C (Sirius core) |
| Power Options | Up to 100 kW (Sirius) |
| Cooling | Electrodeless, water-free operation |
| Compliance | Designed for ISO/IEC 17025 laboratories, compatible with GLP/GMP data integrity requirements |
| Interface | Modular ICP-MS sampler cone adapters (Agilent, Thermo Fisher, PerkinElmer, Nu Instruments) |
| Brand | Endress+Hauser |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RAMANRXN2 |
| Instrument Type | Grating-Based Raman Spectrometer |
| Excitation Wavelength Options | 532 nm, 785 nm, or 1000 nm |
| Channel Configuration | Single-Channel (Standard), Optional 4-Channel Multiplexing |
| Probe Compatibility | Rxn-10 (with accessory optics), Rxn-30, Rxn-40, Rxn-41, Rxn-45, Rxn-46 |
| Hazardous Area Certifications | ATEX, IECEx, North American Class I Div 1/2, Class II Div 1/2 |
| Installation Form Factor | Benchtop or Mobile Cart-Mounted |
| Regulatory Compliance | Designed for cGMP/GLP environments, supports FDA 21 CFR Part 11–compliant audit trails when integrated with validated software platforms |
| Software Interface | Embedded touchscreen control with optional remote web-based access via Ethernet/Wi-Fi |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Nanophoton RAMANdrive |
| Instrument Type | Fourier Transform Raman Spectrometer |
| Spatial Resolution | 350 nm (X), 500 nm (Y), 1 µm (Z) |