BrandFangZhou
OriginSichuan, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelDDS-307+ Wastewater Conductivity Meter
Conductivity Range0.000–200.0 μS/cm and 0.200–200.0 mS/cm (7 auto-ranging spans)
Temperature Range−5.0 to +105.0 °C
Accuracy±1.0% FS ±1 digit
Resolution0.001 μS/cm (lowest range)
Temp. CompensationAutomatic/Manual (−5.0 to +105.0 °C), ATC-enabled
Temp. Coefficient2.0%/°C
Electrode CompatibilityDJS-0.01, DJS-0.1, DJS-1.0, DJS-10.0 cells
InterfaceBNC electrode port, Pt1000 or thermistor temperature input, RS232 serial output
IP RatingIP65-rated housing (corrosion- and splash-resistant)
ComplianceISO 9001 certified manufacturing & quality control
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFangZhou
OriginSichuan, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelDDS-609 Aluminum Chloride-Specific Conductivity Meter
Detection ParametersMulti-parameter (Conductivity, Resistivity, TDS, Salinity, Conductivity Ash, Temperature)
PortabilityBenchtop
Application EnvironmentLaboratory
Conductivity Range(0–2×10⁵) µS/cm
TDS Range(0.00–300.0) g/L
Resistivity Range(5.00–10⁸) Ω·cm
Salinity Range(0.00–80.00) ppt
Temperature Range(−25.0–135.0) °C
Accuracy±0.5% FS
Minimum Conductivity Resolution0.0001 µS/cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFangZhou
OriginSichuan, China
ModelDDS-302+
Form FactorBenchtop
ApplicationLaboratory
Conductivity Range(0–2×10⁵) µS/cm
TDS Range(0.00–300.0) g/L
Resistivity Range(5.00–10⁸) Ω·cm
Salinity Range0 ppt
Temperature Range(−25.0–135.0) °C
Accuracy±0.5% FS
Minimum Conductivity Resolution0.0001 µS/cm
Instrument Class0.5
Data Storage Capacity≥100,000 records
Calibration Points4 Chinese standard, 6 US/EU standard, 1 custom solution
Temperature CompensationAutomatic (ATC) and Manual (MTC), with adjustable reference temperature (15.0–25.0 °C)
ComplianceGLP-compliant data logging, ISO 9001 certified manufacturing
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: FangZhou
OriginSichuan, China
ModelDDS-609
Form FactorBenchtop
ApplicationLaboratory
Conductivity Range(0–2×10⁵) µS/cm
TDS Range(0.00–300.0) g/L
Resistivity Range(5.00–10⁸) Ω·cm
Salinity Range(0.00–80.00) ppt
Temperature Range(−25.0–135.0) °C
Accuracy±0.5% FS
Minimum Conductivity Resolution0.0001 µS/cm
Calibration Points4 Chinese standard, 6 international (ASTM/ISO), 1 custom
GLP ComplianceYes
Data Storage Capacity≥100,000 measurement records
InterfaceRS-232, USB, 0–20 mV analog output
Temperature CompensationATC/MTC, linear & nonlinear modes
Electrode Constants Supported0.01, 0.1, 1.0, 10.0 cm⁻¹
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFangZhou
OriginSichuan, China
ModelDDS-609 Seawater Conductivity Meter
Form FactorBenchtop
Application EnvironmentLaboratory
Conductivity Range(0–2×10⁵) µS/cm
TDS Range(0.00–300.0) g/L
Resistivity Range(5.00–10⁸) Ω·cm
Salinity Range(0.00–80.00) ppt
Temperature Range(−25.0–135.0) °C
Accuracy±0.5% FS
Minimum Conductivity Resolution0.0001 µS/cm
Instrument Class0.5
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFangZhou
OriginSichuan, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelDDS-609 Purified Water Conductivity Meter
Detection ParametersMulti-parameter (Conductivity, Resistivity, TDS, Salinity, Conductive Ash, Temperature)
PortabilityBenchtop
Application EnvironmentLaboratory
Conductivity Range(0–2×10⁵) µS/cm
TDS Range(0.00–300.0) g/L
Resistivity Range(5.00–10⁸) Ω·cm
Salinity Range(0.00–80.00) ppt
Temperature Range(−25.0–135.0) °C
Accuracy±0.5% FS
Minimum Resolution0.0001 µS/cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFangZhou
OriginSichuan, China
ModelDDS-307+ (New Version)
Form FactorBenchtop
ApplicationLaboratory Use
Conductivity Range0.000 µS/cm to 200.0 mS/cm
TDS Range0.000 mg/L to 200.0 g/L
Resistivity Range5.00 Ω·cm to 100.0 MΩ·cm
Salinity Range(0.00–80.00) ppt
Temperature Range(−9.9–135.0) °C
Accuracy±1.0% of Full Scale
Minimum Resolution0.001 µS/cm
Temperature CompensationAutomatic (ATC) and Manual (MTC)
CalibrationBuilt-in 4 standard points + 1 user-defined point
Data Storage2000 GLP-compliant records
InterfaceUSB, RS-232, 0–20 mV analog output
ComplianceISO 9001 certified
Instrument Class1.0
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFangZhou
OriginSichuan, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelDDS-609 Sulfuric Acid Conductivity Meter
Detection ParametersMulti-parameter (Conductivity, Resistivity, TDS, Salinity, Conductivity Ash, Temperature)
PortabilityBenchtop
Application EnvironmentLaboratory
Conductivity Range(0–2×10⁵) µS/cm
TDS Range(0.00–300.0) g/L
Resistivity Range(5.00–10⁸) Ω·cm
Salinity Range(0.00–80.00) ppt
Temperature Range(−25.0–135.0) °C
Accuracy±0.5% FS
Minimum Resolution0.0001 µS/cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFangZhou
OriginSichuan, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelDDS-609 Multi-Parameter Conductivity Meter
Price RangeUSD 700–1,400
Measurement ParametersConductivity, Resistivity, TDS, Salinity, Conductivity Ash, Temperature
PortabilityBenchtop
Application EnvironmentLaboratory
Conductivity Range(0–2×10⁵) µS/cm
TDS Range(0.00–300.0) g/L
Resistivity Range(5.00–10⁸) Ω·cm
Salinity Range(0.00–80.00) ppt
Temperature Range(−25.0–135.0) °C
Accuracy±0.5% FS
Minimum Conductivity Resolution0.0001 µS/cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFangZhou
OriginSichuan, China
ModelDDS-11A
Measurement ParameterSingle (Conductivity)
Form FactorBenchtop
Application EnvironmentLaboratory
Conductivity Range0–2×10⁵ µS/cm
Temperature Range−5.0 to 105.0 °C
Accuracy±1.5% FS ±1 digit
Resolution0.001 µS/cm (lowest range)
Temperature CompensationManual
Cell Constants Supported0.01, 0.1, 1.0, 10.0 cm⁻¹
InterfaceBNC electrode port, Pt100/NTC temperature input, RS232 serial output
ComplianceISO 9001 certified manufacturing
Instrument Class1.5
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFangZhou
OriginSichuan, China
ModelDDS-200
Detection ParameterSingle-parameter (Conductivity/TDS/Resistivity/Salinity/Temperature)
PortabilityPortable
Application EnvironmentLaboratory & Field
Conductivity Range0–2×10⁵ µS/cm
TDS Range0.00–200.0 g/L (TDS factor = 1.00)
Resistivity Range5.00–10⁸ Ω·cm
Salinity Range0.00–80.00 ppt
Temperature Range−15.0–125.0 °C
Accuracy±1.0% FS ±1 digit (Conductivity, TDS, Resistivity), ±2.0 ppt ±1 digit (Salinity), ±0.3 °C ±1 digit (Temperature)
Resolution0.001 µS/cm (min), auto-ranging across 7 scales
Temperature CompensationAutomatic (ATC) or Manual, Adjustable β coefficient (2.0%/°C default), Compensation Range: −15.0–125.0 °C
Data Storage200 measurement records with timestamp
Electrode CompatibilityFour-cell constant options (0.01, 0.1, 1.0, 10.0 cm⁻¹)
Enclosure RatingIP65
Power SupplyDual-mode (AC adapter + rechargeable Li-ion battery)
Auto-off DelayConfigurable (default 10 min)
Calibration MemoryNon-volatile storage of calibration constants
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFangZhou
OriginSichuan, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelDDS-609 Sugar-Specific Conductivity Analyzer
Conductivity Range(0–2×10⁵) µS/cm
TDS Range(0.00–300.0) g/L
Resistivity Range(5.00–10⁸) Ω·cm
Salinity Range(0.00–80.00) ppt
Temperature Range(−25.0–135.0) °C
Accuracy±0.5% FS
Minimum Resolution0.0001 µS/cm
ComplianceISO 9001 certified
GLP SupportFull audit trail, user authentication, method versioning, electronic signature-ready data export (GLP, Standard, Simplified formats)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFangZhou
OriginSichuan, China
Instrument TypeBenchtop Conductivity Meter
ApplicationLaboratory-grade Ultra-Pure Water Monitoring
Conductivity Range(0–2×10⁵) µS/cm
Resistivity Range(5.00–10⁸) Ω·cm
TDS Range(0.00–300.0) g/L
Salinity Range0 ppt
Temperature Range(−25.0–135.0) °C
Accuracy±0.5% FS
Minimum Conductivity Resolution0.0001 µS/cm
Temperature CompensationAutomatic (ATC) and Manual (MTC)
Calibration Points4 Chinese Standard, 6 US/EU Standard, 1 Custom Solution
Data Storage Capacity≥100,000 records
ComplianceGLP-compliant data logging with audit trail, ISO 9001 certified manufacturing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFangZhou
OriginSichuan, China
ModelDDS-608
Measurement ParametersConductivity, Resistivity, TDS, Salinity, Temperature
Form FactorBenchtop
Application EnvironmentLaboratory
Conductivity Range0–2×10⁵ µS/cm
TDS Range0.00–200.0 g/L (TDS factor = 1)
Resistivity Range5.00–10⁸ Ω·cm
Salinity Range0.00–80.00 ppt
Temperature Range−9.9 to 135.0 °C
Accuracy±0.5% FS (conductivity, resistivity, TDS)
Minimum Conductivity Resolution0.001 µS/cm
Temperature CompensationAutomatic (ATC) or Manual (MTC)
CalibrationInternal 4-point standard + 1 custom point
Data Storage4096 GLP-compliant records with timestamp
InterfaceRS232 serial port + 0–20 mV analog output
ComplianceISO 9001 certified manufacturing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFangZhou
OriginSichuan, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelDDS-309+
Detection ParametersConductivity, Resistivity, TDS, Salinity, Temperature
PortabilityBenchtop
Application EnvironmentLaboratory
Conductivity Range(0–2×10⁵) µS/cm
TDS Range0–200.0 g/L (calculated from conductivity)
Resistivity Range(0.005–∞) Ω·cm (derived inversely)
Salinity Range0–100.0 ppt (NaCl equivalent)
Temperature Range(−5.0–105.0) °C
Accuracy±0.5% FS (Conductivity), ±0.3 °C ±1 digit (Temperature)
Minimum Resolution0.001 µS/cm
Temperature CompensationAutomatic (ATC) or Manual, Adjustable Coefficient (0.0–10.0)%/°C
Cell Constant Range0.007–15.00 cm⁻¹ (auto/manual)
Calibration Points3 built-in standard points (e.g., 84.0 µS/cm, 1.413 mS/cm, 12.88 mS/cm)
InterfaceBNC electrode port, Pt1000 temperature sensor input, RS232 serial port, 0–20 mV analog output
IP RatingIP65 front panel (dust-tight, water-jet resistant)
ComplianceISO 9001 certified manufacturing process, conforms to JJG 376–2007 (Chinese national verification regulation for conductivity meters)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFangZhou
OriginSichuan, China
ModelDDS-200 Portable Wastewater Conductivity Meter
PortabilityHandheld
Application EnvironmentLaboratory & Field
Conductivity Range0–1×10⁵ µS/cm
TDS Range (at coefficient = 1)0.00–200.0 g/L
Resistivity Range5.00–10⁸ Ω·cm
Salinity Range0.00–80.00 ppt
Temperature Range−15.0–125.0 °C
Accuracy±1.0% FS
Minimum Resolution0.001 µS/cm
IP RatingIP65
Data Storage200 measurement sets
Auto-Temperature Compensation (ATC)Yes
Electrode CompatibilityDJS-0.01 / 0.1 / 1.0 / 10.0 cells
Power SupplyAC/DC dual-mode
Default Auto-Off10 min (user-adjustable)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFangZhou
OriginSichuan, China
ModelDDS-609
Form FactorBenchtop
ApplicationLaboratory
Conductivity Range(0–2×10⁵) µS/cm
TDS Range(0.00–300.0) g/L
Resistivity Range(5.00–10⁸) Ω·cm
Salinity Range(0.00–80.00) ppt
Temperature Range(−25.0–135.0) °C
Accuracy±0.5% FS
Minimum Conductivity Resolution0.0001 µS/cm
Calibration Points4 Chinese Standard, 6 US/EU Standard, 1 Custom Solution
Temperature CompensationAutomatic (ATC) & Manual (MTC), Adjustable Reference Temp (15.0–25.0 °C)
Data Storage≥100,000 measurement records
InterfacesRS-232, USB, 0–20 mV analog output
ComplianceGLP-compliant data logging with full audit trail, ISO 9001 certified manufacturing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFangZhou
OriginSichuan, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelDDS-309+
PriceUSD 520 (FOB)
Measured ParametersConductivity, Resistivity, TDS, Temperature
Form FactorBenchtop
Intended UseLaboratory
Conductivity Range(0–2×10⁵) µS/cm
TDS Range0–199.9 g/L (calculated from conductivity, NaCl equivalence)
Resistivity Range(0.00–19.99) MΩ·cm
Salinity Range0–80.0 ppt (NaCl scale)
Temperature Range(−5.0–105.0) °C
Accuracy±0.5% FS (conductivity), ±0.3 °C ±1 digit (temperature)
Minimum Resolution0.001 µS/cm
Temperature CompensationAutomatic (ATC) or Manual, Adjustable Coefficient (0.0–10.0)%/°C (default 2.0%/°C)
Cell Constant RangeAuto-detect 0.007–15.0 cm⁻¹ or manual entry
Calibration Points3 built-in standard points (e.g., 84 µS/cm, 1413 µS/cm, 12.88 mS/cm)
Data OutputRS-232 serial interface + 0–20 mV analog output
Environmental RatingIP65 front panel (splash-resistant, corrosion-resistant housing)
ComplianceISO 9001 certified manufacturing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFangZhou
OriginSichuan, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelDDS-307
Detection ParameterSingle-parameter (Conductivity)
Form FactorBenchtop
Intended UseLaboratory
Conductivity Range0–2×10⁵ µS/cm
TDS RangeNot Supported
Resistivity RangeNot Supported
Salinity RangeNot Supported
Temperature Range−5.0 to 105.0 °C
Accuracy±1.0% FS
Minimum Resolution0.001 µS/cm
Instrument Class1.0
Temperature CompensationManual
Auto-ranging7-step
Electrode CompatibilityDJS-0.01, DJS-0.1, DJS-1.0, DJS-10.0
InterfaceBNC electrode port, Pt1000 temperature input, RS232 serial output
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFangZhou
OriginSichuan, China
ModelDDS-609 Wine Conductivity Meter
Form FactorBenchtop
Application EnvironmentLaboratory
Conductivity Range(0–2×10⁵) µS/cm
TDS Range(0.00–300.0) g/L
Resistivity Range(5.00–10⁸) Ω·cm
Salinity Range(0.00–80.00) ppt
Temperature Range(−25.0–135.0) °C
Accuracy±0.5% FS
Minimum Conductivity Resolution0.0001 µS/cm
Instrument Class0.5 Grade
Calibration Points4 Chinese Standard, 6 US/EU Standard, 1 Custom Solution
Temperature CompensationAutomatic (ATC) / Manual (MTC), Adjustable Reference Temp (15.0–25.0 °C)
Data Storage Capacity≥100,000 measurement records
InterfaceRS-232, USB, 0–20 mV analog output
ComplianceGLP-compliant data logging with audit trail metadata (user ID, electrode ID, method ID, timestamp, calibration history)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFangZhou
OriginSichuan, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelDDS-609 Wastewater Conductivity Analyzer
Price RangeUSD 700–1,400 (FOB)
Measured ParametersConductivity, Resistivity, TDS, Salinity, Conductive Ash, Temperature
PortabilityBenchtop
Application EnvironmentLaboratory
Conductivity Range(0–2×10⁵) µS/cm
TDS Range(0.00–300.0) g/L (TDS factor = 1.0)
Resistivity Range(5.00–10⁸) Ω·cm
Salinity Range(0.00–80.00) ppt
Temperature Range(−25.0–135.0) °C
Accuracy±0.5% FS
Minimum Conductivity Resolution0.0001 µS/cm
Temperature CompensationAutomatic (ATC) or Manual (MTC), Linear/Nonlinear, Reference Temp Adjustable (15.0–25.0 °C)
CalibrationUp to 4 Chinese standard points, 6 US/EU standard points, 1 custom solution
Data Storage≥100,000 measurement records
InterfaceRS-232, USB, 0–20 mV analog output
GLP ComplianceFull audit trail, user authentication, method traceability, electronic signature support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFangZhou
OriginSichuan, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelDDS-609
PriceUSD 920 (FOB)
Measurement ParametersConductivity, Resistivity, TDS, Salinity, Conductivity Ash, Temperature
PortabilityBenchtop
Application EnvironmentLaboratory
Conductivity Range(0–2×10⁵) µS/cm
TDS Range(0.00–300.0) g/L
Resistivity Range(5.00–10⁸) Ω·cm
Salinity Range(0.00–80.00) ppt
Temperature Range(−25.0–135.0) °C
Accuracy±0.5% FS
Minimum Conductivity Resolution0.0001 µS/cm
Instrument Class0.5 Grade
Calibration Points4 Chinese Standard, 6 US/EU Standard, 1 Custom Solution
TDS Factor Adjustment0.2–1.00 (default 0.5)
Temperature CompensationAutomatic (ATC) / Manual (MTC), Reference Temp Adjustable (15.0–25.0 °C)
Data Storage Capacity≥100,000 measurement records
InterfaceRS-232, USB, 0–20 mV analog output
GLP ComplianceFull audit trail, user ID/password, method & electrode management, timestamped data export
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFangZhou
OriginSichuan, China
ModelDDS-302+
Form FactorBenchtop
ApplicationLaboratory
Conductivity Range(0–2×10⁵) µS/cm
TDS Range(0.00–300.0) g/L
Resistivity Range(5.00–10⁸) Ω·cm
Salinity Range0 ppt
Temperature Range(−25.0–135.0) °C
Accuracy±0.5% FS
Minimum Conductivity Resolution0.0001 µS/cm
Instrument Class0.5
Data Storage Capacity≥100,000 records
Calibration Points4 Chinese standard, 6 US/EU standard, 1 custom solution
Temperature CompensationAutomatic (ATC) & Manual (MTC), adjustable reference temperature (15.0–25.0 °C)
ComplianceGLP-compliant data logging with audit trail, ISO 9001 certified manufacturing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFangZhou
OriginSichuan, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelDDS-609 Power Plant Water Conductivity Analyzer
Detection ParametersConductivity, Resistivity, TDS, Salinity, Conductivity Ash, Temperature
PortabilityBenchtop
Application EnvironmentLaboratory
Conductivity Range(0–2×10⁵) µS/cm
TDS Range(0.00–300.0) g/L
Resistivity Range(5.00–10⁸) Ω·cm
Salinity Range(0.00–80.00) ppt
Temperature Range(−25.0–135.0) °C
Accuracy±0.5% FS
Minimum Resolution0.0001 µS/cm