Color Difference Meter
Filter
Showing 541–562 of 562 results
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | Ci7600 |
| Geometry | d/8° (SPIN & SPEX) |
| Short-Term Repeatability | ≤ 0.03 ΔE*ab RMS on white tile |
| Inter-instrument Agreement | ≤ 0.15 ΔE*ab avg. |
| Aperture Sizes (Reflectance) | 25 mm, 17 mm*, 10 mm, 6 mm, 3.5 mm* |
| Aperture Sizes (Transmittance) | 3 standard + 2 optional |
| Measurement Spot Sizes | 20 mm, 12 mm, 5 mm, 2.7 mm |
| Measurement Time | ≈ 2.5 s |
| Spectral Range | 360–750 nm |
| Spectral Interval | 10 nm (default), 20 nm selectable |
| Optical System | 2D CCD array with holographic grating |
| Illuminant | Pulsed xenon lamp, D65 calibrated |
| UV Control | Integrated UV filters (up to 3) |
| Photometric Resolution | 0.01% |
| Lamp Lifetime | ≥ 1,000,000 measurements |
| Operating Temperature | 5–40 °C |
| Storage Temperature | −20–50 °C |
| Relative Humidity | 5–85%, non-condensing |
| Dimensions (L×W×H) | 56 × 22 × 31 cm |
| Weight | 20.5 kg |
| Shipping Dimensions | 71 × 38 × 53 cm |
| Shipping Weight | 25 kg |
| Interface | USB 2.0 |
| Software Development Kit | XDS4 |
| Embedded NetProfiler | Yes |
| Internal Temp/Humidity Sensor | Yes |
| Laser Targeting | Yes |
| Sample Preview Camera | Yes |
| Status Panel | LED-based |
| Power | 100–240 VAC, 50–60 Hz |
| Warm-up Time | None required |
| Calibration Standards | Included white tile, black trap, UV calibration kit |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | Ci7600 |
| Product Type | Spectrophotometric Color Measurement Instrument |
| Instrument Form Factor | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 360–750 nm |
| Repeatability (ΔE*₀₀ RMS) | 0.03 |
| UV Control Option | Available |
| Internal Environmental Sensors | Temperature & Relative Humidity |
| Compliance | ASTM E308, CIE No. 15, ISO/CIE 11664, USP <85> (Colorimetric Assay Guidance) |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | Ci7800 |
| Geometry | d/8° (diffuse illumination, 8° viewing) |
| Short-term Repeatability (White Tile) | ≤ 0.01 ΔE*ab RMS |
| Inter-instrument Agreement | ≤ 0.08 ΔE*ab avg. |
| Spot Sizes | 25 mm, 17 mm, 10 mm, 6 mm, 3.5 mm |
| Aperture Sizes | 20 mm, 12 mm, 5 mm, 2.7 mm |
| Measurement Time | ≈ 2.5 s |
| Spectral Range | 360–780 nm |
| Spectral Interval | 10 nm (default), 5 nm, 20 nm |
| Spectral Reporting | 10 nm, 5 nm, 20 nm |
| Illuminant | Pulsed Xenon (D65 calibrated) |
| Photometric Range | 0–200% |
| Photometric Resolution | 0.00% |
| Detector | 2D CCD Array with Holographic Grating |
| Reflectance Apertures | 4 standard + 1 optional |
| Transmittance Apertures | 4 |
| UV Control | Up to 3 UV filters |
| Operating Humidity | 5–85% RH (non-condensing) |
| Operating Temperature | 5–40 °C |
| Storage Temperature | −20–50 °C |
| Dimensions (L×W×H) | 56 × 22 × 31 cm |
| Weight | 20.5 kg |
| Shipping Dimensions | 71 × 38 × 53 cm |
| Shipping Weight | 25 kg |
| Interface | USB 2.0 |
| Software Development Kit | XDS4 |
| Built-in Camera | Yes (preview + active laser target positioning) |
| Embedded NetProfiler Support | Yes |
| Internal Temp/Humidity Sensors | Yes |
| Lamp Timer | Yes |
| UV Calibration Tools | White tile, black trap, UV reference standards |
| Compliance | ASTM E308, ISO/CIE 11664, ISO 7724, ISO 13655, USP <1061>, FDA 21 CFR Part 11 (via compatible software) |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | Ci7800 |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Xenon flash lamp |
| Spectral Range | 360–780 nm |
| Repeatability (ΔE* RMS) | 0.01 |
| UV Control Option | Yes |
| Internal Temperature & Humidity Sensors | Yes |
| Transmission Apertures | 27, 17, 10, 6 mm |
| Reflectance Apertures | 25, 17, 10, 6, 3.5 mm |
| Compliance | ASTM E308, CIE No. 15, USP <857> |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | Ci7860 |
| Product Type | Benchtop Spectrophotometer |
| Instrument Type | Benchtop |
| Optical Geometry | 0/45° Integrating Sphere |
| Illuminant | UV-Enabled |
| Spectral Range | 360–780 nm |
| Repeatability (RMS ΔE*) | 0.01 |
| Inter-instrument Agreement (Avg. ΔE* SCI) | 0.06 |
| Spectral Resolution | 10 nm |
| Photometric Resolution | 0.001% |
| UV Filter Options | Standard 400 nm, Optional 420 nm & 460 nm |
| Reflectance Apertures | 25 mm, 17 mm, 10 mm, 6 mm, 3.5 mm (optional) |
| Transmittance Apertures | 27 mm, 17 mm, 10 mm, 6 mm |
| Dual-Mode Measurement | SPIN & SPEX Simultaneous |
| Compliance | CIE 15:2018, ASTM D2244, ASTM E308, ISO 7724-1, ISO 13655, ISO 17972-1 (PantoneLIVE), FDA 21 CFR Part 11 (with Color iQC v6.0+) |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | CiF3200 |
| Aperture Options | 2 mm, 4 mm, 8 mm, 12 mm (virtual) |
| Illumination Geometry | d/8° (diffuse illumination, 8° viewing) |
| Spectral Range | 400–700 nm at 10 nm intervals |
| Optical Resolution | 10 nm |
| Measurement Time | ~15 s |
| Measurement Distance | 0 mm (contact mode) |
| Repeatability (White Tile) | ≤0.025 ΔE* (SPIN) |
| Inter-instrument Agreement (BCRA Tiles) | ≤0.15 ΔE* (SPIN) |
| Light Source | LED (≥500,000 measurements lifespan) |
| Spectral Report Output | Full reflectance spectrum (400–700 nm, 10 nm step) |
| Display | Integrated high-resolution touchscreen |
| Connectivity | USB |
| Operating Temperature | 10–40 °C |
| Storage Temperature | −20–70 °C |
| Humidity Range | 0–85% RH (non-condensing) |
| Power Supply | Universal AC input (100–240 VAC) |
| Weight | ~4 kg |
| Enclosure Color | Black & silver |
| Warranty | 12 months |
| Software Integration | Compatible with X-Rite Color iQC, supported SDK for custom integration |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | Ci™4200 / Ci™4200UV |
| Optical Geometry | d/8° with DRS spectral engine |
| Illumination/Measurement Apertures | 14 mm illuminating / 8 mm measuring |
| Light Source | Tungsten-halogen lamp (Ci™4200) |
| Detector | Blue-enhanced silicon photodiode |
| Spectral Range | 400–700 nm |
| Spectral Interval | 10 nm (acquisition and output) |
| Reflectance Range | 0–200% |
| Inter-instrument Agreement | Avg. 0.20 ΔE*ab (CIE L*a*b*, BCRA Series II, SCI mode, including specular component) |
| Short-term Repeatability | 0.05 ΔE*ab (white tile, SCI) |
| Measurement Time | ~2 s (simultaneous SCI/SCE) |
| UV Calibration Support | Yes (Ci™4200UV only) |
| Gloss Measurement | 60° gloss data output |
| Transform Support | Yes |
| Lamp Lifetime | ~500,000 measurements |
| Power Supply | 90–130 VAC or 100–240 VAC, 50–60 Hz, max 15 W |
| Interface | USB |
| Operating Temp. | 10–40°C, ≤85% RH (non-condensing) |
| Storage Temp. | −20–50°C |
| Weight | 5.2 kg |
| Dimensions | 22.0 × 19.0 × 26.4 cm (H × W × L) |
| Accessories | Black trap, white/green calibration tiles, UV calibration standard (Ci™4200UV), power adapter, USB cable, user manual |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | Color iMatch / Color iQC Version 6.2 |
| Software Version | 6.2 |
| Compliance | ASTM D2244, ISO 11664-4, CIE No. 15:2018, CxF3 v3.0 Support |
| Data Export | Spectral Reflectance (360–740 nm), CIE L*a*b*, L*C*h°, ΔE00, ΔE76, Tolerancing (Asymmetric LABtol & LCHtol) |
| Hardware Integration | Compatible with X-Rite eXact, Ci7x00, SP series spectrophotometers |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | 7000A |
| Repeatability (White Tile) | 0.01 RMS ΔE (CIE Lab) |
| Inter-instrument Agreement (LAV) | 0.08 avg. ΔE (CIE Lab) |
| Light Source | Pulsed Xenon Arc |
| Measurement Time | < 1 s |
| Spectral Range | 360–700 nm |
| Wavelength Accuracy | ±0.1 nm (400–700 nm) |
| Wavelength Precision | ±0.05 nm (400–700 nm) |
| Wavelength Interval | 10 nm |
| Reflectance Range | 0–200% |
| Resolution | 0.01% |
| Apertures | LAV (25.4 mm), MAV (15.2 mm), SAV (7.5 × 10 mm), VSAV (3.0 × 8.0 mm) |
| Geometry | d/8° (diffuse illumination / 8° viewing) with 152 mm integrating sphere |
| Transmission Mode | Direct & Diffuse |
| UV Control | Motorized, D65-matched UV compensation with two preset UV bands |
| Mirror Finish Compensation | Motor-driven specular component exclusion (SCI/SCE) |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | eXact™ |
| Aperture Options | 1.5 mm, 2 mm, 4 mm, 6 mm |
| Battery | Li-ion, 7.4 VDC, 2200 mAh |
| Color Difference Metrics | CIE ∆E* (1976), ∆ECMC, CIE ∆E* (2000), CIE ∆E* (1994) |
| Color Spaces | CIE L*a*b*, CIE L*C*h° |
| Density Range | 0.0 D – 3.0 D |
| Density Standards | Status A, E, I, T, G |
| Dimensions | 18 cm × 7.8 cm × 7.6 cm (7.1" × 3.1" × 3.0") |
| Illuminants | A, C, D50, D55, D65, D75, F2, F7, F11, F12 |
| Communication | USB 2.0 |
| Measurement Geometry | 45°/0° annular illumination per ISO 5-4:2009(E) |
| Observer Angles | 2° and 10° |
| Spectral Range | 400–700 nm |
| Spectral Interval | 10 nm |
| Measurement Time | < 1 sec |
| Inter-instrument Agreement | Avg. 0.25 ΔEab, Max 0.45 ΔEab (M0/M2), 0.55 ΔEab (M3) |
| Short-term Repeatability | ±0.01 D (density, CMYK), 0.05 ΔEab (white BCRA std dev) |
| Operating Temp | 10–35°C (50–95°F) |
| Storage Temp | −20–50°C (−4–122°F) |
| Relative Humidity | 30–85% RH (non-condensing) |
| Embedded Capabilities | G7 Certification, NetProfiler, PantoneLIVE, BestMatch Auto-Calibration |
| Software Compatibility | X-Rite ColorCert, Color iQC, InkFormulation, NetProfiler, SDK support |
| Compliance | ISO 5-4:2009(E), ISO 13655:2009, ISO 12233 (for M-mode spectral validation) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | X-Rite IntelliTrax |
| Pricing | Available Upon Request |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | MA-5 QC |
| Measurement Angles | 5 (r45as15, r45as25, r45as45, r45as75, r45as110) |
| Illuminant Options | D65, A, C, D50, F2, F7, F11, F12 |
| Observer Angle | 2° & 10° |
| Spectral Range | 400–700 nm |
| Spectral Interval | 10 nm |
| Aperture Size | Ø ≈ 12 mm |
| Measurement Time | 2.5 s |
| Repeatability (White Tile) | ≤ 0.02 ΔE* |
| Inter-instrument Agreement (BCRA Set) | 0.18 ΔE* avg |
| Display | 2.8″ QVGA TFT resistive touchscreen (240 × 320) |
| Operating Temp. | 10–40 °C |
| Storage Temp. | −20–50 °C |
| Relative Humidity | ≤ 85 % RH |
| Weight | 0.6 kg |
| Dimensions (L×W×H) | 180 × 70 × 95 mm |
| Light Source | White LED (10-year lifetime) |
| Battery | Rechargeable Li-ion (≥2000 cycles) |
| Connectivity | USB 2.0 |
| Software Mode | MA-94 Emulation |
| Data Storage | 1000 samples |
| Supported Languages | English, French, Italian, Spanish, German, Portuguese, Chinese, Japanese, Korean |
| Compliance | ISO 13655:2017, ASTM E308, CIE No. 15:2018, DIN 6175-2, ISO 12647-2 |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | MA-T6 / MA-T12 |
| Product Type | Multi-Angle Spectrophotometer |
| Instrument Type | Portable |
| Optical Geometry | 0/45° integrating sphere |
| Light Source | Full-spectrum white LED with blue-enhancement |
| Spectral Range | 400–700 nm |
| Spectral Interval | 10 nm (31 data points) |
| Reflectance Range | 0–600% |
| Repeatability | ΔE* < 0.10 (gray BCRA tiles), ΔE* < 0.25 (colored BCRA tiles) |
| Inter-instrument Agreement | 0.18 ΔE2000 (BCRA reference tiles) |
| Measurement Angles | MA-T6 — 6 angles (15° illumination, 6 receiver positions) |
| Effect Parameters | Sparkle, Graininess, Distinctness of Image (DOI)-equivalent flop index |
| Sparkle Reproducibility | ±1.9% (mean error) |
| Graininess Reproducibility | ±1.4% (mean error) |
| Sparkle Repeatability | ±0.12% (mean error) |
| Graininess Repeatability | ±0.09% (mean error) |
| Display | 3.5-inch color touchscreen (8.9 cm) |
| Measurement Time | 4 s acquisition + 1.5 s calculation |
| Calibration | Internal black trap & white tile |
| Calibration Interval | Recommended every 30 days |
| Connectivity | USB 2.0, Wi-Fi |
| Storage Capacity | >2,000 samples + 600 images |
| Power | Rechargeable Li-ion battery (7.4 VDC, 2400 mAh) |
| Operating Temperature | 10–50 °C, ≤85% RH (non-condensing) |
| Storage Temperature | −20–50 °C, ≤85% RH (non-condensing) |
| Dimensions | 26.6 × 9.5 × 12.8 cm (L×W×H) |
| Weight | 1.2 kg |
| Compliance | ASTM D2244, E308, E1164, E2194, E2539 |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | MetaVue VS3200 |
| Measurement Geometry | 45/0 |
| Spectral Range | 400–700 nm @ 10 nm resolution |
| Inter-instrument Agreement | Avg. ΔE*ab ≤ 0.15 |
| Repeatability (White Tile) | ≤ 0.025 ΔE*ab |
| Aperture Sizes | 2 mm, 4 mm, 6 mm, 8 mm, 10 mm, 12 mm |
| Sample Position Sensing | Yes |
| Lamp Lifetime | ≥ 350,000 measurements |
| Measurement Cycle Time | < 10 s |
| Compliance Standards | ASTM D2244, ASTM E179, ASTM E308, ASTM E1164, CIE 15, DIN 5033-7, DIN 5036, DIN 6174, ISO 7724-1/2/3, JIS Z 8722 |
| Backward Compatibility | X-Rite VS450 and 964 data formats |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | RM200QC |
| Instrument Type | Portable |
| Optical Geometry | d/8° integrating sphere (with 45/0 imaging mode) |
| Light Source | Tungsten-halogen lamp + UV LEDs (Ci4200UV) |
| Spectral Range | 400–700 nm |
| Repeatability | 0.05 ΔE*ab (typical, white tile, D65/10°) |
| Measurement Apertures | 4 mm and 8 mm |
| Measurement Time | 1.8 s |
| Standard Memory | 20 |
| Sample Memory | 350 |
| Display | 4.5 cm color TFT LCD |
| Interface | USB Mass Storage Class |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −20–60 °C |
| Relative Humidity | 20–80 % RH (non-condensing) |
| Altitude Limit | 2000 m |
| Pollution Degree | 2 |
| Overvoltage Category | II |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 964 |
| Pricing | Upon Request |
| Measurement Geometry | 0°/45° |
| Spectral Sensor | DRS (Diffuse Reflectance Spectrometer) |
| Aperture Options | 4 mm measuring / 6.5 mm illuminating |
| Light Source | Pulsed Tungsten-Halogen Lamp |
| Standard Illuminants | C, D50, D65, D75, A, F2, F7, F11, F12 |
| Standard Observer Angles | 2° and 10° |
| Detector | Blue-Enhanced Silicon Photodiode |
| Spectral Range | 400–700 nm |
| Spectral Interval | 10 nm (acquisition & output) |
| Memory Capacity | 1,024 standards (with tolerances), 2,000 sample measurements |
| Inter-instrument Agreement (7 mm/15 mm) | Avg. 0.15 ΔE*ab (BCRA II avg.), Max. 0.30 ΔE*ab (any BCRA II) |
| (4 mm) | Avg. 0.20 ΔE*ab (12 BCRA II), Max. 0.40 ΔE*ab |
| Short-Term Repeatability | 0.05 ΔE*ab (white tile, SD of 20 readings) |
| Reflectance Range | 0–200% |
| Measurement Time | ~2 s |
| Lamp Lifetime | ~500,000 measurements |
| Power | Removable NiMH rechargeable battery pack |
| AC Adapter | 90–130 VAC or 100–240 VAC, 50–60 Hz, max. 15 W |
| Charge Time | ~4 h to full capacity |
| Measurements per Charge | ~1,000 (within 8 h) |
| Display | 128 × 256 pixel monochrome LCD |
| Data Interface | Bidirectional RS-232, baud rate 300–57,600 |
| Operating Temperature | 10–40 °C (50–104 °F) |
| Max. Relative Humidity | 85% RH (non-condensing) |
| Storage Temperature | −20–50 °C (−4–122 °F) |
| Weight | 1.1 kg (2.4 lb) |
| Dimensions (H×W×L) | 10.9 × 8.4 × 19.6 cm (4.3″ × 3.3″ × 7.7″) |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | WSC-1B / WSC-2B / WSC-3B |
| Optical Geometry | 8°/d (diffuse illumination, 8° viewing) |
| Illuminant Options | D65, D50, A |
| Observer Angle | 10° standard observer |
| Spectral Response | Silicon photodiode array |
| Repeatability | ≤0.07 ΔE*ab (WSC-1B), ≤0.06 ΔE*ab (WSC-2B & WSC-3B), measured on white calibration tile (n=30) |
| Inter-instrument Agreement | ≤0.80 ΔE*ab (WSC-1B), ≤0.50 ΔE*ab (WSC-2B), ≤0.40 ΔE*ab (WSC-3B) |
| Measurement Aperture | Φ4 mm (WSC-1B), Φ8 mm (WSC-2B), dual Φ8 mm / Φ4 mm (WSC-3B) |
| Display | 2.8″ TFT true-color LCD |
| Color Spaces | CIE L*a*b*, L*C*h*, XYZ, RGB, L*u*v*, YI (Yellowness Index), WI (Whiteness Index), Color Fastness |
| Color Difference Formulas | ΔE*ab, ΔE*C*h*, ΔE*94, ΔE*CMC, ΔE*00, ΔE*Hunter |
| Storage Capacity | 100 reference standards + 20,000 sample measurements |
| Power | Rechargeable lithium-polymer battery (3.7 V, 3200 mAh) |
| charging time | 8 h |
| Operating Environment | −10 °C to 40 °C, 0–85% RH (non-condensing) |
| Dimensions & Weight | 205 × 67 × 80 mm / 450 g (WSC-1B) |
| Compliance | GB/T 3977–2008, GB/T 5698–2001, GB/T 7921–2008, JJG 595–1989 |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | WSC-2S |
| Instrument Type | Desktop |
| Optical Geometry | 0°/45° integrating sphere |
| Illuminant | CIE Standard Illuminant D65 (10° observer) |
| Spectral Response | Equivalent to CIE 1964 10° standard observer tristimulus values X, Y, Z |
| Repeatability | δu(Y) ≤ 0.2, δu(x) ≤ 0.003, δu(y) ≤ 0.003 |
| Display | 7-inch capacitive touch screen |
| Color Spaces | CIE XYZ, CIE Yxy, CIELAB (L*a*b*), CIELCh, CIELUV, Hunter Lab |
| Whiteness Indices | Ganz, CIE Blue-Reflectance (W = B), ASTM E313 Yellowness Index (YI), Hunter Whiteness (Wh), Building Materials Whiteness (Wj), Taber (W = 4B − 3G) |
| Data Storage | 1,000 measurement sets with recall capability |
| Interfaces | USB host/device, USB flash drive support |
| Compliance | JJG 595–2002 (Class I), GB/T 13173–2021, GB/T 5950–2008, GB/T 17644–1998, ASTM E313, ISO 2470–1 |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | WSF-1S |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Tungsten Halogen Lamp |
| Spectral Range | 400–700 nm |
| Repeatability | σu(Y) ≤ 0.5, σu(x), σu(y) ≤ 0.003 |
| Wavelength Accuracy | ±2 nm |
| Transmittance Accuracy | ±1.5% |
| Stability | ΔY ≤ 0.4 |
| Colorimetric Accuracy | ΔY ≤ 2, Δx/Δy ≤ 0.02 |
| Measurement Aperture | Φ20 mm |
| Display | 7-inch Touchscreen (Chinese UI) |
| Compliance | GBT 3978–2008 (equivalent to CIE No. 15:2004 under D65/A/C illuminants and 2°/10° standard observer) |
| Color Spaces | CIE XYZ, Yxy, CIELAB (L*a*b*), CIELUV (L*u*v*), CIELCH, Hunter Lab, Munsell, MI, CMYK, YI, Whiteness (Ganz, CIE, Blue Light, Taubel) |
| Color Difference Metrics | ΔE*ab, ΔEab, ΔE*uv |
| Communication | USB, RS232, USB Flash Drive Support |
| Power Supply | 220 V ± 22 V, 50 Hz ± 1 Hz, 70 W |
| Dimensions | 475 × 280 × 152 mm |
| Net Weight | 8 kg |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | Chame-IH100 |
| Price | USD 5,600 (FOB Beijing) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | Chame-LH200 |
| Pricing | Available Upon Request |
| Integration Sphere Diameter | 200 mm / 500 mm |
| Radiometric Range | 16–100 W |
| Photometric Range (White Light) | 3,500–21,875 lm |
| Red LED Luminous Flux Range | 600–3,750 lm |
| Green LED Luminous Flux Range | 1,800–11,250 lm |
| Blue LED Luminous Flux Range | 800–5,000 lm |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | LB-700 |
| Dimensions (W×D×H) | 1500 × 700 × 1500 mm |
| Luminous Intensity Range | 100–50,000 mcd |
| Photometric Accuracy (Luminous Intensity) | < ±5% |
| Repeatability (Luminous Intensity) | < ±3% |
| CIE x,y Chromaticity Accuracy (CIE 127-B) | < ±0.004 |
| CIE x,y Repeatability | < ±0.003 |
| Spectrometer | Chameleon Series, 380–780 nm, Optical Resolution: 1 nm, A/D: 16-bit |
| XY Translation Stage | 2-axis, X: 600 mm, Y: 145 mm, Positioning Accuracy: ±0.02 mm |
| Power Supply | 0–250 V, 0–1 A |
| Voltage Accuracy | 0.05% + 2 LSB |
| Current Accuracy | 0.15% + 5 LSB |
| Data Export Format | Excel |