Color Difference Meter
Filter
Showing 451–480 of 562 results
| Brand | Konica Minolta |
|---|---|
| Origin | Shanghai, China |
| Model | CR-400 / CR-410 |
| Type | Portable Spectrophotometric Colorimeter |
| Optical Geometry | d/8° integrating sphere (with specular component included) |
| Light Source | Pulsed xenon arc lamp |
| Spectral Range | 300–700 nm |
| Repeatability | ΔE*ab ≤ 0.07 (after white calibration plate measurement, 30 times at 10 s intervals) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CR-400 |
| Type | Portable Color Difference Meter |
| Optical Geometry | d/8° integrating sphere (diffuse illumination, 8° viewing, including specular component) |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | Y Reflectance: 0.01–160.00% |
| Repeatability | ΔE*ab ≤ 0.07 (std. dev., white calibration, 30 measurements at 10 s intervals) |
| Instrument Error | ΔE*ab ≤ 0.6 (BCRA Series II 12-color average, CIE D65 illuminant, 2° standard observer) |
| Measurement Aperture | 8 mm (measuring), 11 mm (illumination) |
| Measurement Time | 1 s |
| Minimum Interval | 3 s |
| Data Storage | 1,000 measurements (instrument only) |
| Display | Backlit dot-matrix LCD (15×9 characters + icon line) |
| Power | 4× AAA alkaline/Ni-MH batteries or AC adapter AC-A17 (120 V / 230 V, 50–60 Hz) |
| Dimensions | 102 × 244 × 63 mm |
| Weight | ~550 g (incl. batteries, excl. cable) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CR-400 / CR-410 |
| Illumination/Reception Geometry | d/0 (diffuse illumination, 0° viewing |
| Detector | Silicon photodiodes (6 channels) |
| Light Source | Pulsed xenon lamp |
| Measurement Time | 1 s |
| Minimum Interval Between Measurements | 3 s |
| Repeatability | ΔE*ab ≤ 0.07 (after white calibration, 30 measurements at 10 s intervals) |
| Instrument Error | ΔE*ab ≤ 0.6 (CR-400), ≤ 0.8 (CR-410) against BCRA Series II 12-color standard set |
| Aperture Size | CR-400: Ø8 mm measurement / Ø11 mm illumination |
| CR-410 | Ø50 mm measurement / Ø53 mm illumination |
| Reflectance Range | Y = 0.01–160.00% |
| Observer Angle | CIE 2° standard observer |
| Illuminants | C, D65 |
| Color Spaces | XYZ, Yxy, L*a*b*, L*C*h, CIELAB, CIELUV, CMC(l:c), CIE 1994, CIE 2000, Hunter Lab, CIE Whiteness (WI) & Yellowness (YI) per ASTM E313/D1925 (C or D65 dependent) |
| Display | Backlit dot-matrix LCD (15 × 9 characters + icon line) |
| Memory Capacity | 1000 measurements (head-only mode) |
| Interface | RS-232C (default baud rate: 9600 bps) |
| Power | 4 × AAA alkaline or Ni-MH batteries |
| Dimensions (W × H × D) | 102 × 244 × 63 mm |
| Weight | ~550 g (CR-400), ~570 g (CR-410), incl. batteries |
| Operating Environment | 0–40 °C, ≤85% RH (non-condensing) |
| Storage Environment | −20–40 °C, ≤85% RH (non-condensing) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CR-400 / CR-410 |
| Instrument Type | Portable |
| Optical Geometry | d/8° integrating sphere (with specular component included) |
| Light Source | Pulsed xenon lamp |
| Spectral Range | Y Reflectance 0.01–160.00% |
| Repeatability | ΔE*ab ≤ 0.07 (standard deviation, after white calibration tile measurement, 30 times at 10-second intervals) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CR-400 / CR-410 |
| Instrument Type | Portable |
| Light Source | Pulsed Xenon Lamp |
| Aperture Options | Φ8 mm (CR-400), Φ50 mm (CR-410) |
| Repeatability | ΔE*ab ≤ 0.07 (after white calibration, 30 measurements at 10-sec intervals) |
| Accuracy | ΔE*ab ≤ 0.6 (CR-400), ≤ 0.8 (CR-410) |
| Memory Capacity | 100 target colors + 1,000 measurement records (standalone) |
| Display | Backlit LCD, 6-language support (English, German, French, Italian, Spanish, Japanese) |
| Power | Rechargeable battery or AC adapter |
| Compliance | Designed for ISO 7724-1, CIE No. 15, ASTM E308, and JIS Z 8722 colorimetric standards |
| Brand | KONICA MINOLTA |
|---|---|
| Origin | Japan |
| Model | CS-100A |
| Type | SLR-type tristimulus spot chroma meter for luminance and colorimetric measurement |
| Luminance Range (Fast) | 0.01–299,000 cd/m² |
| Luminance Range (Slow) | 0.01–49,900 cd/m² |
| Luminance Accuracy | ±2% ±1 digit |
| Chromaticity Accuracy (x,y) | ±0.004 (CIE Illuminant A, 18–28°C) |
| Repeatability (Y) | ±0.2% ±1 digit |
| Repeatability (x,y) | ±0.001 (Y ≥100 cd/m², fast mode) |
| Measurement Angle | 1° |
| Field of View | 9° with 1° measurement area indicator |
| Optical System | 85 mm f/2.8 lens |
| Focus Distance | 1014 mm to infinity |
| Sensor | Three filtered silicon photodiodes approximating CIE 1931 color matching functions |
| Response Time | Fast (sampling: 0.1 s, display: 0.8–1.0 s) |
| Slow (sampling | 0.4 s, display: 1.4–1.6 s) |
| Display | External 3-digit LCD (Y, x, y) |
| Interface | RS-232C (4800 bps) |
| Power | 9 V alkaline battery (included) |
| Dimensions (W×H×D) | 79 × 208 × 154 mm |
| Weight | 890 g (without battery) |
| Operating Environment | 0–40°C, ≤85% RH (non-condensing at ≤35°C) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CS-200 |
| Measurement Angles | 1° / 0.2° / 0.1° |
| Luminance Range | 0.01–20,000,000 cd/m² (at 0.1°) |
| Accuracy (Lv) | ±2% ±1 digit (≥10 cd/m², Source A, slow mode) |
| Accuracy (xy) | ±0.003 (≥10 cd/m², Source A, slow mode) |
| Repeatability (Lv) | ±0.1% ±1 digit (2–200,000 cd/m², 2σ, auto mode) |
| Spectral Method | Grating + Linear Photodiode Array |
| Minimum Measured Area | 0.1 mm (with close-up lens) |
| Interface | USB 1.1 |
| Power | AC adapter or 4× AA batteries (~3 h continuous operation) |
| Dimensions | 95 × 127 × 330 mm |
| Weight | 1.8 kg (body only) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CS-200 |
| Type | Color and Luminance Meter |
| Measurement Principle | Spectral Matching Method (CIE 1931 2° Standard Observer) |
| Photodetector | Silicon Photodiode |
| Luminance Range | 0.01 to 20,000,000 cd/m² (at 0.1° field of view) |
| Illuminance Range | 0.1 to 99,990 lx |
| Chromaticity Accuracy (xy) | ±0.002 (Std. Illuminant A, 800 lx) |
| Repeatability (xy) | ±0.0005 |
| Temporal Stability | 2 measurements/sec (continuous) |
| Output Interface | RS-232C |
| Display | 4-digit LCD with backlight |
| Power | Four AA alkaline batteries (≈72 h continuous use) or AC adapter AC-A10 |
| Dimensions | 69 × 174 × 35 mm |
| Weight | 215 g (body only) |
| Compliance | JIS C 1609-1993 Class AA (fs ≤ 8%), ISO/CIE traceable calibration protocols |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CS-2000 |
| Measurement Wavelength Range | 380–780 nm |
| Wavelength Resolution | 0.9 nm/pixel |
| Spectral Bandwidth (FWHM) | <5 nm |
| Measurement Angles | 1°, 0.2°, 0.1° (interchangeable) |
| Luminance Range (A-source) | 0.003–5,000 cd/m² (1°), 0.075–125,000 cd/m² (0.2°), 0.3–500,000 cd/m² (0.1°) |
| Minimum Displayed Luminance | 0.00002 cd/m² |
| Luminance Accuracy | ±2% (A-source, ≥0.003 cd/m²) |
| Chromaticity Accuracy | x,y ±0.003 to ±0.001 (dependent on luminance level) |
| Repeatability (2σ) | Luminance 0.15–0.4%, Chromaticity 0.0004–0.002 |
| Polarization Error | ≤2% (1°), ≤3% (0.1°/0.2°) |
| Integration Time | Fast mode 0.005–16 s, Normal mode 0.005–120 s |
| Measurement Time | 2–243 s |
| Operating Environment | 5–35°C, RH ≤80% (non-condensing) |
| Dimensions | 158 × 200 × 300 mm (main unit), Ø70 × 95 mm (lens) |
| Weight | 6.2 kg |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | FD-7 |
| Product Type | Spectrodensitometer |
| Instrument Type | Portable |
| Optical Geometry | d/8° integrating sphere |
| Compliance | ISO 13655:2009 M1 condition |
| Key Feature | Virtual Fluorescence Standard (VFS) technology |
| Weight | 350 g (main unit), 430 g (with aperture mask) |
| Spectral Measurement Capability | Supports D50-spectrum-referenced fluorescence evaluation |
| Wavelength Compensation | Automatic, performed during routine white calibration |
| Ambient Light Measurement | Yes, supports illuminance, CCT, and CIE tristimulus values under real-world lighting |
| Software Integration | basICColor catch all for strip scanning (MediaWedge, ECI2002, IT8.7/3) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | FD-9 |
| Product Type | Spectrodensitometer |
| Instrument Type | Desktop |
| Optical Geometry | d/8° integrating sphere |
| Compliance | ISO 5-4, ISO 13655:2017 (M0/M1/M2/M3), ASTM E308, ISO 2846-1 |
| Connectivity | USB 2.0, TCP/IP Ethernet |
| Display | Built-in high-resolution LCD touchscreen |
| Automation Support | Optional auto-feeder (up to 100 sheets) |
| Measurement Mode | Single-spot stop-and-measure (non-scanning) |
| Data Output | Multi-illumination condition simultaneous reporting (M0, M1, M2) |
| Software Interface | Konica Minolta SpectraMagic NX Pro (FDA 21 CFR Part 11 compliant audit trail optional) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | LS-100 |
| Measurement Angle | 1° |
| Optical System | Single-lens reflex (SLR) with f=85 mm, F2.8 lens |
| Field of View (Finder) | 9° with diopter adjustment |
| Minimum Measurement Distance | ∞ to 1,014 mm (∞ to φ14.4 mm) |
| Close-up Lens Options | No.153 (φ18.7–φ8.0 mm), No.135 (φ8.7–φ5.2 mm), No.122 (φ4.3–φ3.2 mm), No.110 (φ1.5–φ1.3 mm) |
| Detector | Silicon photodiode |
| Spectral Match Error (fₛ) vs. CIE V(λ) | ≤8% |
| Response Modes | FAST (display time: 0.8–1.0 s |
| sampling | 0.1 s), SLOW (display time: 1.4–1.6 s |
| sampling | 0.4 s) |
| Luminance Range | FAST: 0.001–299,900 cd/m² |
| SLOW | 0.001–49,990 cd/m² |
| Accuracy | ±2% ±1 digit (>1,000 cd/m²) |
| Repeatability | ±0.2% ±1 digit (>1,000 cd/m²) |
| Temperature Drift | ±3% ±1 digit (0–40°C, referenced to 20°C) |
| Calibration Modes | Konica Minolta standard or user-defined reference (1 channel) |
| Luminance Ratio Mode | 1 channel, manual or measured reference input |
| Measurement Functions | Instant luminance, peak luminance, luminance ratio (%) |
| Display | 4-digit LCD (external & eyepiece-mounted with LED backlight) |
| Digital Interface | RS-232C compliant (4,800 bps), bidirectional control and data logging |
| Power Supply | One 9 V alkaline battery (JIS 6F22) or optional DP-10 data printer |
| Power Consumption | ~16 mA (finder illumination ON, measurement active) |
| Operating Environment | 0–40°C, ≤85% RH (non-condensing), Pollution Degree 2, Overvoltage Category II |
| Storage | −20–55°C, ≤85% RH (non-condensing) |
| Dimensions & Weight | 79 × 208 × 150 mm (W × H × D), 850 g (body only, no battery) |
| Standard Accessories | Lens cap, eyepiece ND filter, eyepiece cap, 9 V battery, carrying case |
| Brand | Konica Minolta |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Portable Colorimetric Luminance Meter |
| Model | LS-150 / LS-160 |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Tungsten-filament lamp |
| Luminance Range | 0.001–999,900 cd/m² (LS-150) |
| Repeatability | ±0.2% + 1 digit (luminance, reference source A) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | Multi Gloss 268 |
| Measurement Angles | 20°, 60°, 85° |
| Measurement Spot Size | 20°: 10 × 10 mm |
| 60° | 9 × 15 mm |
| 85° | 5 × 38 mm |
| Standards Compliance | ISO 2813, ISO 7668, ASTM D523, ASTM D2457, DIN 67530, JIS Z 8741, BS 3900, BS 6161-12 |
| Measurement Range | 20°: 0.0–2000 GU |
| 60° | 0.0–1000 GU |
| 85° | 0.0–160 GU |
| Resolution | 0.1 GU (0.0–99.9 GU), 1 GU (100–2000 GU) |
| Repeatability | ±0.2 GU (0.0–99.9 GU), ±0.2% of reading (100–2000 GU) |
| Instrument Error | ±0.5 GU (0.0–99.9 GU), ±0.5% of reading (100–2000 GU) |
| Data Storage | 999 measurements with timestamp |
| Standard Memory | 50 reference standards |
| Measurement Speed | 0.5 s per reading |
| Power Source | 1.5 V AA (R6) alkaline batteries (approx. 10,000 measurements) |
| Auto Power-Off | Adjustable 10–99 s |
| Operating Environment | 15–40 °C, ≤85% RH (non-condensing at ≤35 °C) |
| Storage Conditions | −10–60 °C, ≤85% RH (non-condensing at ≤35 °C) |
| Dimensions | 155 × 73 × 48 mm |
| Weight | 400 g |
| Interface | RS-232C |
| Supported Languages | English, Spanish, German, French, Italian, Japanese |
| Software | GlossLink data exchange software |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | Novo-Gloss 60 KM |
| Measurement Angle | 60° |
| Compliance | ASTM D523, ASTM D2457, ISO 2813, DIN 67530, JIS Z8741 |
| Data Storage Capacity | 2,000 measurements |
| Interface | Bluetooth 4.0 |
| Display | Graphical LCD with intuitive menu navigation |
| Instrument Type | Portable benchtop gloss meter |
| Application Scope | Medium-gloss coatings, automotive paints, plastic surfaces, lacquers, and industrial finishes |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NR-1 |
| Pricing | Upon Request |
| Measurement Geometry | 0°/45° (JIS Z 8722 compliant) |
| Measured Color Spaces | CIELAB (ΔL* a* b*), CIELCH (ΔL* C* H*), ΔE*ab, ΔEab, ΔLab |
| Pass/Fail Threshold Evaluation | User-definable ΔE*ab or ΔEab |
| Aperture Size | Φ10 mm |
| Illuminant | Tungsten Halogen Lamp (3 V / 1.5 A) |
| Repeatability (ΔE*ab) | ≤0.1 (based on SD of 20 measurements on certified white reference tile) |
| Dimensions (W × D × H) | 200 × 70 × 68 mm |
| Weight | 0.6 kg |
| Power Supply | AC adapter (400 mW) |
| Optional Accessories | Windows-compatible data acquisition & analysis software, RS-232C interface cable, thermal printer |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | Portable |
| Measurement Principle | Di: 8°, De: 8° (Diffuse Illumination / 8° Viewing) with SCI/SCE modes |
| Standard Compliance | ISO 7724-1, CIE No. 15:2004, DIN 5033-7, JIS Z 8722 Condition c, ASTM E1164 (SCI), JIS Z 8741, ISO 2813, ASTM D523-08, ASTM D2457-13 |
| Spectral Range | CM-26dG: 360–740 nm |
| CM-26d/CM-25d | 400–700 nm |
| Spectral Interval | 10 nm |
| FWHM | ~10 nm |
| Aperture Options | MAV (Ø8 mm or Ø12 mm), SAV (Ø3 mm or Ø6 mm) |
| Repeatability | ΔE*ab ≤ 0.02 (CM-26dG), ≤ 0.04 (CM-26d/CM-25d) |
| Gloss Repeatability | ±0.1 GU (0–9.99 GU), ±0.2 GU (10–99.99 GU), ±0.2% of reading (100–200 GU) |
| Inter-instrument Agreement | ΔE*ab ≤ 0.12 (BCRA Series II, MAV SCI) |
| Gloss | ±0.2 GU (0–9.99 GU), ±0.2 GU (10–99.99 GU) |
| Gloss Measurement | 60° geometry, white LED source, 0–200 GU range |
| Display | 2.7" color TFT-LCD with flip-up vertical viewing |
| Data Storage | 1,000 target + 5,100 sample records |
| Battery Life | ~3,000 measurements (SCI/SCE + gloss mode, 10-sec interval, 23°C), ~1,000 with Bluetooth active |
| Interface | USB 2.0, optional Bluetooth SPP module |
| Operating Environment | 5–40°C, ≤80% RH (non-condensing) |
| Dimensions (W×H×D) | ~81×93×229 mm |
| Weight | ~660 g (CM-26dG), ~630 g (CM-26d), ~620 g (CM-25d) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | Rhopoint IQ-S |
| Instrument Type | Benchtop |
| Measurement Angles | 20°, 60°, 85° |
| Gloss Metrics | Gloss (20°/60°/85°), Reflected Image Quality (RIQ), Reflection Haze (logHaze), Specular Peak Reflectance (Rspec), Distinctness of Image (DOI) |
| Reflectance Curve Acquisition | Yes (20° incident, ±30° angular scan) |
| Compliance | ISO 2813, ASTM D523, ASTM E430, ISO 13803, ISO 10216, ISO 17299 |
| Software | Rhopoint IQ Software v5.0+ with GLP-compliant audit trail, data export (CSV, PDF, XML), statistical reporting (mean, SD, min/max, n≥2), curve overlay & comparative analysis |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Rhopoint TAMS |
| Product Type | Spectrophotometric Color & Texture Analyzer |
| Instrument Type | Benchtop |
| Measurement Principle | Phase Measuring Deflectometry (PMD) + Multi-Angle Spectrophotometry |
| Compliance | ISO 16610, DIN EN ISO 4287, DIN EN ISO 25178, ASTM D7113 |
| Data Export Format | *.res, CSV, PNG, TIFF |
| Software Compatibility | OptiMap Reader v5.2+, Rhopoint Analysis Suite |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | T-10 |
| Compliance | JIS C 1609-1993 Class AA (T-10/T-10M), JIS Precision Grade (T-10P) |
| Photodetector | Silicon photodiode |
| Spectral mismatch (fₛ) | ≤4% (T-10P), ≤8% (T-10/T-10M) |
| Cosine error | ±1% at 10°, ±2% at 30°, ±6% at 50°, ±7% at 60°, ±25% at 80° |
| Illuminance range | 0.01–299,900 lx |
| Integrated illuminance range | 0.01–999,900×10³ lx·h |
| Measurement functions | NORM (illuminance), Δ (difference/ratio), Σ (integrated illuminance, duration, hourly average) |
| Accuracy | ±2% ±1 digit |
| Temp./humidity drift | ±3% ±1 digit |
| Output | RS-232C digital, analog (1 mV/digit, max 3 V, 10 kΩ output impedance) |
| Display | 3-digit (some 4-digit) LCD with auto-backlight |
| Power | Two AA alkaline batteries (≥72 h continuous use) or optional AC adapter |
| Dimensions | 69 × 174 × 35 mm |
| Weight (excl. batteries) | 200 g |
| Operating environment | −10–40 °C, ≤85% RH (non-condensing), Pollution Degree 2, Equipment Class II |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | Uni-Gloss 60 |
| Measurement Angle | 60° |
| Measurement Spot Size | 9 × 15 mm |
| Standards Compliance | ISO 2813, ISO 7668, ASTM D523, ASTM D2457, DIN 67530, JIS Z 8741, BS 3900, BS 6161-12 |
| Measurement Range (60°) | 0.0–1000 GU |
| Resolution | 0.1 GU (0.0–99.9 GU), 1 GU (100–1000 GU) |
| Repeatability | ±0.2 GU (0.0–99.9 GU), ±0.2% of reading (100–1000 GU) |
| Instrument Error | ±0.5 GU (0.0–99.9 GU), ±0.5% of reading (100–1000 GU) |
| Memory Capacity | 999 measurements with timestamp |
| Reference Standards Storage | 50 user-defined standards |
| Battery Life | ~10,000 measurements (with 1.5 V AA alkaline cells) |
| Measurement Interval | 0.5 s |
| Auto Power-Off | Adjustable 10–99 s |
| Operating Language | English, Spanish, German, French, Italian, Japanese |
| Operating Environment | 15–40 °C, ≤85% RH (non-condensing at ≤35 °C) |
| Storage Conditions | −10–60 °C, ≤85% RH (non-condensing at ≤35 °C) |
| Power Supply | 1.5 V AA (R6) alkaline batteries (4 pcs) |
| Dimensions | 155 × 73 × 48 mm (W × H × D) |
| Weight | 400 g |
| Interface | RS-232C |
| Included Accessories | 60° calibration tile (high-gloss ceramic), RS-232C cable, carrying case, GlossLink data exchange software, 4 × AA batteries |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VSR-300A |
| Pricing | Available Upon Request |
| Measurement Areas | Φ0.05 mm, Φ0.1 mm, Φ0.2 mm, Φ0.5 mm |
| Illumination/Reception Geometry | 45°–0° (45° annular illumination, perpendicular detection) |
| Sample Stage Travel Range | X: 120 mm, Y: 90 mm, Z: 50 mm |
| Light Source | 12 V / 4 A Halogen Lamp |
| Detector | Color CCD Camera |
| Compliance Standards | JIS Z 8722, ASTM E 308 |
| Display | 14" Color Monitor |
| Power Consumption | 90 W AC |
| Optical Unit Dimensions | 360 × 360 × 460 mm (W × D × H) |
| Measurement Unit Dimensions | 350 × 360 × 110 mm (W × D × H) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CR-10 |
| Instrument Type | Portable |
| Optical Geometry | d/8° integrating sphere (with specular component included) |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 360 nm – 750 nm |
| Repeatability | ΔE*ab ≤ 0.1 (standard deviation, measured on certified white tile under D65/10°) |
| Brand | Konika-Minolta |
|---|---|
| Origin | Japan |
| Model | CF-300 |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | In-Line |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | High-CRI White LED |
| Spectral Range | 400–700 nm |
| Repeatability | Chromaticity ΔE*ab ≤ 0.02 (standard deviation) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CM-3700A |
| Instrument Type | Desktop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 360 nm – 740 nm |
| Wavelength Interval | 10 nm |
| FWHM | ~14 nm |
| Reflectance Range | 0–200% (resolution: 0.001%) |
| Repeatability | ΔE*ab ≤ 0.005 (after white calibration, 30 measurements at 10 s intervals) |
| Transmittance Geometry | d/0° |
| UV Control | Motorized filter, 1000-step adjustable |
| Measurement Apertures | LAV Φ25.4 mm / Φ28 mm, MAV Φ8 mm / Φ11 mm, SAV 3 mm × 5 mm / 5 mm × 7 mm |
| Measurement Time | 0.6–0.8 s |
| Minimum Interval | 3 s |
| Inter-instrument Agreement | Avg. ΔE*ab ≤ 0.08, Max. ΔE*ab ≤ 0.3 (BCRA Series II 12-color tile set) |
| Temperature Drift | ΔE*ab ≤ 0.05 / °C |
| Dimensions | 271 × 274 × 500 mm |
| Weight | 18 kg |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CR-10plus |
| Instrument Type | Portable |
| Optical Geometry | 8°/diffuse (8/d) |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Repeatability | σ(ΔE*ab) ≤ 0.1 |
| Display Languages | English, Chinese, Japanese |
| Measurement Aperture | Ø8 mm (standard), Ø5 mm (optional) |
| Observer Angle | 10° |
| Illuminant | D65 |
| Color Spaces | CIE L*a*b*, L*C*H*, CIE 1976 ΔE*ab |
| Data Storage | Up to 1,000 measurements (including reference standards) |
| Interface | USB 2.0 |
| Power Supply | 4 × AA alkaline/Ni-MH batteries, USB bus power, or AC adapter (optional) |
| Dimensions | 66 × 158 × 85 mm |
| Weight | 420 g (without batteries) |
| Operating Environment | 0–40°C, ≤85% RH (non-condensing at 35°C) |
| Compliance | DIN 5033-7, JIS Z 8722 (Condition d), ISO 7724-1, CIE No. 15, ASTM E1164 |
| Brand | Konika-Minolta |
|---|---|
| Origin | Japan |
| Instrument Type | Portable |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 360 nm – 750 nm |
| Repeatability | ΔE*ab ≤ 0.1 (standard deviation) |
| Product Category | Color Difference Meter |
| Compliance | Designed for ISO 7724, CIE No. 15, ASTM E308, and JIS Z 8722 |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Instrument Type | Portable |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | Y Reflectance 0.01–160.00% |
| Repeatability | ΔE*ab ≤ 0.07 (std. dev., white calibration, 30 measurements at 10 s intervals) |
| Measurement Aperture | Ø50 mm / Illumination Area: Ø53 mm |
| Measurement Time | 1 s |
| Minimum Interval | 3 s |
| Battery Life | ~800 measurements (AAA alkaline/Ni-MH, Konica Minolta specified conditions) |
| Display | Backlit dot-matrix LCD (15×9 characters + icon line), 6 language options (EN/DE/FR/IT/ES/JP) |
| Data Storage | 1,000 measurements (instrument-only) |
| Standard Calibration | CR-A44 white calibration tile |
| Compliance | CIE 1931 2° standard observer, CIE No. 15:2004, ISO 7724-1, ASTM E308, JIS Z 8722 |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Instrument Type | Portable |
| Measurement Angles | 20°, 60°, 85° (Multi Gloss 268A) |
| Repeatability | 0.0–99.9 GU: ±0.2 GU |
| 100–2,000 GU | ±0.2% of reading |
| Inter-instrument Agreement (60CT) | 0.0–19.9 GU: ±0.2 GU |
| Spot Size (60S) | 2 mm × 4 mm |
| Spot Size (60A) | 9 mm × 15 mm |
| Display | Full-color LCD |
| Power | Single AA alkaline battery (~4,000 measurements) |
| Compliance | ISO 2813, ASTM D523, DIN 67530, JIS Z8741 (except GM-60S) |
| Software | smart-lab Gloss & smart-chart |
| Languages | 10 selectable UI languages |
| Brand | Lasertec |
|---|---|
| Origin | Japan |
| Instrument Type | Portable |
| Optical Geometry | 45°c:0° (45° circumferential illumination / 0° vertical viewing) |
| Spectral Range | 360–740 nm |
| Wavelength Interval | 10 nm (FWHM ≈ 10 nm) |
| Measurement Areas | MAV Ø8.0 mm / SAV Ø3.0 mm |
| Gloss Measurement | 60°, 0–200 GU |
| Repeatability | ΔE*ab ≤ 0.04 (std dev, white tile, n=30) |
| Inter-instrument Agreement | ΔE*ab ≤ 0.15 (BCRA Series II, 12 tiles) |
| Display | 2.7″ TFT color LCD |
| Battery Life | ~3,000 measurements (standalone, 10 s interval) |
| Compliance | CIE No.15, ISO 7724-1, ISO 2813, ASTM E179, ASTM D523, JIS Z 8722, JIS Z 8741 |
