Empowering Scientific Discovery

Comet Durranda (Wuxi) Measurement Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDerenda
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelAPM-200
Price RangeUSD 13,500 – 40,500 (FOB Hamburg)
Pollutants MeasuredO₃, PM₂.₅, PM₁₀
Measurement PrincipleUV Absorption (O₃), Dual-Stage Laser Light Scattering (PM₂.₅/PM₁₀)
Protection RatingIP65
Operating Temperature−30 °C to +50 °C
Operating Humidity0–100 % RH (with auto-heating dehumidification)
Data Storage>100,000 records (expandable via USB/SD)
O₃ Range0–500 µg/m³ (0–250 ppb), Resolution: 0.1 µg/m³, Accuracy: ±2 µg/m³, LOD: 2.0 µg/m³
PM Range0–2500 µg/m³, Resolution: 0.1 µg/m³, Flow Rate: 3.3 L/min
Sampling Interval2 s (configurable), Data Averaging Options: 10 s, 1 min, 5 min, 1 h
ComplianceHJ 590–2010, HJ 654–2013, GB/T 18204.2–2014, EPA 40 CFR Part 50, VDI 4202 Part 1, VDI 4203 Part 3
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDerenda
OriginGermany
ModelAPM-100
Measurement PrincipleUV Absorption (Beer–Lambert Law)
Measurement Range0–500 µg/m³
Resolution0.1 µg/m³
Accuracy±2 µg/m³
Detection Limit2.0 µg/m³
Baseline Drift<3 µg/m³/day, <6 µg/m³/year
Measurement Interval2 s (0.5 Hz)
Data Averaging Options10 s, 1 min, 5 min, 1 h
Data Storage Capacity>100,000 records (expandable via USB/SD card)
Flow Rate0.6–1.5 L/min (nominal 1.0 L/min)
Operating Temperature0–50 °C
Ambient Pressure CompensationYes
Temperature CompensationYes
Protection RatingIP65
Dimensions300 × 250 × 450 mm
Weight~10 kg
ComplianceHJ 193-2013, HJ 654-2013, HJ 818-2018, HJ 965-2018
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDerenda
OriginGermany
ModelAPM-101
Measurement PrincipleUV Absorption (Beer–Lambert Law)
Measurement Range0–500 µg/m³
Resolution0.1 µg/m³
Accuracy±2 µg/m³
Detection Limit2.0 µg/m³
Baseline Drift<3 µg/m³/day, <6 µg/m³/year
Measurement Interval2 s (0.5 Hz)
Data Averaging Options10 s, 1 min, 5 min, 1 h
Data Storage Capacity>100,000 records (expandable via USB/SD card)
Flow Rate0.6–1.5 L/min (nominal 1.0 L/min)
Operating Temperature0–50 °C
Pressure UnithPa
Temperature Unit°C
Ozone Unitsµg/m³, ppb
Dimensions420 × 320 × 180 mm
Weight~7 kg
Built-in Rechargeable Li-ion Battery>24 h operation
GPS ModuleIntegrated
ComplianceHJ 590–2010, HJ 654–2013, GB/T 18204.2–2014, EPA 40 CFR Part 50, VDI 4202 Part 1, VDI 4203 Part 3
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0