- All
- Favorite
- Popular
- Most rated
| Brand | Derenda |
|---|---|
| Origin | Jiangsu, China |
| Model | AWS-1RE |
| Measurement Method | Filter Gravimetry |
| Measurable Parameters | PM₂.₅, PM₁₀, TSP, Low-Concentration Sampling Heads, No. 3 Impingers |
| Temperature Control Range | 15–30 °C (±0.5 °C) |
| Relative Humidity Control Range | 40–60 %RH (±5 %RH) |
| Cleanroom Class | ISO 14644-1 Class 6 |
| Max Throughput | 225 × 47 mm filters / 105 × 90 mm filters / 45 × No. 3 impingers per batch |
| Weighing Time per Filter | ≤20 s |
| Electrostatic Dissipation Efficiency | ≥92% |
| Balance Readability | 0.001 mg (optional 0.0001 mg) |
| Repeatability | 0.003 mg |
| Linearity Error | 0.02 mg |
| Vibration Isolation | Four-Tier Passive Damping System |
| Filter Identification | RFID + QR/Barcode |
| Data Compliance | ASTM D1357, ISO 12103-1, US EPA QA/QC Document 2.12, HJ 656–2013, EN 12341:2014, EN 14907:2005 |
| Brand | Derenda |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | LVS |
| Flow Range | 1.0–3.5 m³/h (adjustable) |
| Vacuum Pressure | >800 hPa |
| Flow Stability | <2.0% deviation over 24 h |
| Maximum Flow Accuracy | ≤±2% |
| Operating Duration under Max Flow & Resistance | 1 min–999 h |
| Rated Service Life under Max Flow & Resistance | >50,000 h |
| Filter Diameter | 47 mm |
| Dimensions | 300 × 250 × 450 mm |
| Weight | ~19.5 kg |
| Noise Level | <62 dB(A) (per DIN 2058, at 8 m distance) |
| Ambient Operating Temperature | −30°C to +50°C |
| Relative Humidity Range | 0–100% RH |
| Ingress Protection Rating | IP55 |
| Power Supply | 220 V ±10%, 50/60 Hz |
| Max Power Consumption | 390 W |
| Data Storage Capacity | >1,000,000 records (5-min intervals) |
| Load Capacity | ≥50 kPa at 1.0 m³/h |
| Brand | Derenda |
|---|---|
| Origin | Germany |
| Model | MVS+AFC |
| Instrument Type | 24-Hour Constant-Temperature Constant-Flow Gas Sampler |
| Instrument Architecture | Multi-Channel Gas Sampler |
| Flow Range | 1.0–4.5 m³/h (adjustable) |
| Vacuum Pressure Capability | >800 hPa |
| Nominal Flow Rate | 2.3 m³/h |
| Flow Stability | ±2.0% deviation over 24 h |
| Operating Duration at Max Flow & Backpressure | 1 min–999 h |
| Service Life Under Max Flow & Backpressure | >50,000 h |
| Filter Diameter | 47 mm |
| Power Supply | 220 V ±10%, 50 Hz |
| Power Consumption | 350 VA |
| Dimensions (MVS) | 300 × 250 × 450 mm |
| Dimensions (AFC) | 440 × 310 × 700 mm |
| Weight (MVS) | 22 kg |
| Weight (AFC) | 24.5 kg |
| Noise Level | <62 dB(A) (per DIN 2058, measured at 8 m) |
| Operating Temperature | −30 °C to +50 °C |
| Operating Humidity | 0–100 %RH |
| Ingress Protection Rating | IP55 |
| Brand | Derenda |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | APM-200 |
| Price Range | USD 13,500 – 40,500 (FOB Hamburg) |
| Pollutants Measured | O₃, PM₂.₅, PM₁₀ |
| Measurement Principle | UV Absorption (O₃), Dual-Stage Laser Light Scattering (PM₂.₅/PM₁₀) |
| Protection Rating | IP65 |
| Operating Temperature | −30 °C to +50 °C |
| Operating Humidity | 0–100 % RH (with auto-heating dehumidification) |
| Data Storage | >100,000 records (expandable via USB/SD) |
| O₃ Range | 0–500 µg/m³ (0–250 ppb), Resolution: 0.1 µg/m³, Accuracy: ±2 µg/m³, LOD: 2.0 µg/m³ |
| PM Range | 0–2500 µg/m³, Resolution: 0.1 µg/m³, Flow Rate: 3.3 L/min |
| Sampling Interval | 2 s (configurable), Data Averaging Options: 10 s, 1 min, 5 min, 1 h |
| Compliance | HJ 590–2010, HJ 654–2013, GB/T 18204.2–2014, EPA 40 CFR Part 50, VDI 4202 Part 1, VDI 4203 Part 3 |
| Brand | Derenda |
|---|---|
| Origin | Germany |
| Model | APM-100 |
| Measurement Principle | UV Absorption (Beer–Lambert Law) |
| Measurement Range | 0–500 µg/m³ |
| Resolution | 0.1 µg/m³ |
| Accuracy | ±2 µg/m³ |
| Detection Limit | 2.0 µg/m³ |
| Baseline Drift | <3 µg/m³/day, <6 µg/m³/year |
| Measurement Interval | 2 s (0.5 Hz) |
| Data Averaging Options | 10 s, 1 min, 5 min, 1 h |
| Data Storage Capacity | >100,000 records (expandable via USB/SD card) |
| Flow Rate | 0.6–1.5 L/min (nominal 1.0 L/min) |
| Operating Temperature | 0–50 °C |
| Ambient Pressure Compensation | Yes |
| Temperature Compensation | Yes |
| Protection Rating | IP65 |
| Dimensions | 300 × 250 × 450 mm |
| Weight | ~10 kg |
| Compliance | HJ 193-2013, HJ 654-2013, HJ 818-2018, HJ 965-2018 |
| Brand | Derenda |
|---|---|
| Origin | Germany |
| Model | APM-101 |
| Measurement Principle | UV Absorption (Beer–Lambert Law) |
| Measurement Range | 0–500 µg/m³ |
| Resolution | 0.1 µg/m³ |
| Accuracy | ±2 µg/m³ |
| Detection Limit | 2.0 µg/m³ |
| Baseline Drift | <3 µg/m³/day, <6 µg/m³/year |
| Measurement Interval | 2 s (0.5 Hz) |
| Data Averaging Options | 10 s, 1 min, 5 min, 1 h |
| Data Storage Capacity | >100,000 records (expandable via USB/SD card) |
| Flow Rate | 0.6–1.5 L/min (nominal 1.0 L/min) |
| Operating Temperature | 0–50 °C |
| Pressure Unit | hPa |
| Temperature Unit | °C |
| Ozone Units | µg/m³, ppb |
| Dimensions | 420 × 320 × 180 mm |
| Weight | ~7 kg |
| Built-in Rechargeable Li-ion Battery | >24 h operation |
| GPS Module | Integrated |
| Compliance | HJ 590–2010, HJ 654–2013, GB/T 18204.2–2014, EPA 40 CFR Part 50, VDI 4202 Part 1, VDI 4203 Part 3 |
| Brand | Derenda |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | MVS |
| Flow Range | 1.0–4.5 m³/h (adjustable) |
| Rated Flow | 2.3 m³/h |
| Maximum Static Pressure | >800 hPa |
| Flow Stability | <2.0% deviation over 24 h |
| Maximum Flow Error | ≤±2% |
| Operating Duration at Max Flow & Load | 1 min–999 h |
| Rated Lifetime at Max Flow & Load | >50,000 h |
| Filter Diameter | 47 mm |
| Dimensions | 300 × 250 × 450 mm |
| Weight | ~17 kg |
| Noise Level | <35 dB(A) (per DIN 2058, measured at 8 m) |
| Operating Temperature | −30°C to +50°C |
| Operating Humidity | 0–100% RH |
| Ingress Protection | IP55 |
| Power Supply | 220 V ±10%, 50/60 Hz |
| Data Storage Capacity | >1,000,000 records (5-min intervals) |
| Compliance | EN 12341:2014 (PM₁₀), EN 14907:2005 (PM₂.₅) |
| Brand | Derenda |
|---|---|
| Origin | Germany |
| Model | PNS-90 |
| Flow Range | 80–120 L/min (adjustable) |
| Rated Flow | 100 L/min (6 m³/h) |
| Vacuum Pressure | >800 hPa |
| Flow Stability | ≤±2.0% deviation over 24 h |
| Operating Lifetime at Max Flow & Backpressure | >50,000 h |
| Maximum Continuous Run Time per Cycle | 1 min–999 h |
| Filter Diameter | 90 mm |
| Dimensions | 590 × 415 × 1100 mm |
| Weight | 65 kg |
| Power Supply | 220 V ±10%, 50 Hz |
| Power Consumption | 470 VA (standby) / 570 VA (operational) |
| Max. Power | 600 VA |
| Data Storage Capacity | >1,000,000 records (1-min resolution, configurable) |
| Operating Temperature | −30 °C to +50 °C |
| Operating Humidity | 0–100 %RH |
| Ingress Protection | IP55 |
| Cooling Module | Peltier-based filter storage unit (≤20 °C) |
| Positioning | Dual-mode BeiDou/GPS |
| Compliant Standards | HJ 618–2011, HJ 93–2013, JJG 943–2011 |
| Brand | Derenda |
|---|---|
| Origin | Jiangsu, China |
| Model | MWS-2 |
| Measurement Method | Filter Gravimetric Method |
| Measured Parameters | TSP / PM₁₀ / PM₂.₅ / PM₁ |
| Compliance | HJ 836–2017, HJ 656–2013, EN 12341:2014, US EPA 40 CFR Part 86/1065, EPA QA Document No. 2.12 (Ambient Air Quality) |
| Sample Capacity (per batch) | 80 × 47 mm filters (160 with optional storage tower), 30 × 90 mm filters (60 with tower), 24 × low-concentration samplers (48 with tower), 24 × No.3 impinger tubes (48 with tower) |
| Temperature Control Range | 15–30 °C (±0.1 °C stability) |
| Humidity Control Range | 40–55 %RH (±2 %RH accuracy) |
| Dew Point Stability | ±0.1 °C |
| Chamber Cleanliness | ISO 14644 Class 6 |
| Weighing Instrument Options | Analytical balance with readability down to 0.01 mg (10 µg) or 0.001 mg (1 µg), integrated anti-vibration platform with decoupling architecture |
| Electrostatic Neutralization | Ionizing air blower (radiation-free, 100% neutralization efficiency per cycle) |
| Identification | QR code, barcode, and optional RFID encoding (chip embedded in sample holder ring) |
| User Interface | Ergonomic front access ports, large transparent viewing panel, built-in control software with audit-trail-capable database |
| Power | 220 V ±10%, 50 Hz, 1000 W |
| Dimensions | 1180 mm (L) × 800 mm (W) × 2000 mm (H) |
| Weight | 400 kg (including climate module) |
| Brand | Derenda |
|---|---|
| Origin | Germany |
| Model | AWS-1 Automated Filter Weighing System |
| Flow Range | 0.2–1.2 m³/h (16.67 L/min) |
| Vacuum Pressure | >40,000 Pa |
| Flow Stability | ≤±2% over 24 h |
| Maximum Flow Error | ≤±2% |
| Operating Duration at Max Flow & Resistance | 1 min–999 h |
| Rated Service Life at Max Flow & Resistance | 50,000 h |
| Balance Resolution | 0.001 mg |
| Balance Stabilization Time | ≤6 s |
| Temperature Control Range | 15–32 °C (±0.1 °C accuracy) |
| Relative Humidity Control Range | 35–55 %RH (±1 %RH accuracy) |
| Dew Point Control Accuracy | ±0.1 °C |
| Dimensions (L×W×H) | 1620 × 900 × 2325 mm |
| System Weight | 600 kg |
| Power Consumption | 1400 W |
| Ambient Operating Temperature | 5–40 °C |
| Brand | Derenda |
|---|---|
| Model | MDM-2 |
| Measurement Principle | Laser Light Scattering (Nephelometry) |
| Measured Parameters | PM₁, PM₂.₅, PM₁₀ |
| PM₂.₅ Range | 0–2500 µg/m³ |
| PM₁₀ Range | 0–5000 µg/m³ (calculated from PM₂.₅) |
| Minimum Detection Limit | 2 µg/m³ |
| Resolution | 0.1 µg/m³ |
| Sampling Flow Rate | ≥0.15 L/min (typical 0.3 L/min) |
| Measurement Interval | 2 s |
| Response Time | ≤5 s |
| Accuracy (24-hr avg) | ±15% |
| Power Supply | Rechargeable Li-ion Battery |
| Battery Life | Up to 8 h |
| Dimensions | 220 mm × 90 mm × 85 mm |
| Weight | ~600 g |
| Data Storage & Transmission | microSD card, 3G/4G module |
| Integrated Sensors | Barometric Pressure, Altitude |
| Display | Color TFT Touchscreen |
| Expected Photometer Lifetime | 5 years |
| Compliance | Designed for field-deployable ambient air monitoring per ISO 12103-1 reference aerosol compatibility and aligned with EPA EQPM-0709-192 performance expectations for portable PM monitors |
| Brand | Derenda |
|---|---|
| Origin | Germany |
| Model | LVS+AFC |
| Flow Range | 1.0–3.5 m³/h (adjustable) |
| Vacuum Pressure | >800 hPa |
| Flow Stability | ≤2.0% deviation over 24 h |
| Maximum Flow Error | ≤±2.0% |
| Operating Duration at Max Flow & Load | 1 min–999 h |
| Service Life at Max Flow & Load | >50,000 h |
| Filter Diameter | 47 mm |
| Power Supply | 220 V ±10%, 50 Hz |
| Power Consumption | 350 VA (without Peltier cooling) / 470 VA (with cooling) |
| Dimensions (LVS) | 300 × 250 × 450 mm |
| Dimensions (AFC) | 440 × 310 × 700 mm |
| Weight (LVS) | 19.5 kg |
| Weight (AFC) | 24.5 kg |
| Noise Level | <62 dB(A) (per DIN 2058, measured at 8 m) |
| Operating Temperature | −30°C to +50°C |
| Operating Humidity | 0–100% RH |
| Ingress Protection | IP55 (without Peltier module) |
| Brand | Derenda |
|---|---|
| Origin | Germany |
| Model | PNS 16T |
| Flow Range | 1.5–3.5 m³/h (adjustable) |
| Vacuum Pressure | 800 hPa |
| Flow Stability | ≤2.0% deviation over 24 h |
| Maximum Flow Error | ≤±2.0% |
| Operating Duration at Max Flow & Load | 1 min to 999 h |
| Rated Lifetime at Max Flow & Load | 50,000 h |
| Filter Diameter | 47 mm |
| Dimensions | 460 × 270 × 1100 mm |
| Weight | 44.5 kg |
| Power Supply | 220 V ±10%, 50 Hz |
| Max Power Consumption | 420 W |
| Noise Level | <62 dB(A) (per DIN 2058, at 8 m) |
| Operating Temperature | −30°C to +50°C |
| Operating Humidity | 0–100% RH |
| Ingress Protection | IP55 |
| Brand | Derenda |
|---|---|
| Origin | Germany |
| Model | APM-2E |
| Measurement Principle | Laser Light Scattering |
| Measured Parameters | PM₁₀ / PM₂.₅ |
| Measurement Range | 0–2500 µg/m³ |
| Minimum Detection Limit | 1 µg/m³ |
| Measurement Interval | 5 s |
| Flow Stability | ±5% |
| Resolution | 0.1 µg/m³ |
| Operating Temperature | −30 °C to +50 °C |
| Operating Humidity | 0–100 %RH (with automatic heating dehumidification) |
| Acoustic Noise | <35 dB(A) (per DIN 2058, at 8 m) |
| Power Supply | AC 220 V ±10 %, 50/60 Hz |
| Enclosure Rating | IP65 |
| Dimensions | 300 × 250 × 480 mm |
| Weight | 15 kg |
| Brand | Derenda |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PNS16T-10 |
| Typical Configuration | Integrated Ambient Air Particulate Sampler |
| Flow Range | 1.0–2.3 m³/h (adjustable) |
| Maximum Vacuum Pressure | >800 hPa |
| Flow Stability | <2.0% deviation over 24 h |
| Maximum Flow Accuracy | ≤±2% |
| Operating Duration at Max Flow & Backpressure | 1 min–999 h |
| Rated Lifetime at Max Flow & Backpressure | >50,000 h |
| Temperature Control Range (Filter Chamber) | ≤20 °C (adjustable, via Peltier cooling) |
| Ambient Operating Temperature | −30 °C to +50 °C |
| Relative Humidity Range | 0–100% RH |
| Sampling Time Range | 1 min–999 h |
| Power Supply | 220 V ±10%, 50 Hz |
| Filter Diameter | 47 mm |
| Dimensions | 330 × 330 × 430 mm |
| Weight | 20 kg |
| Acoustic Noise Level | <62 dB(A) |
| Ingress Protection Rating | IP55 |
| Max Power Consumption | 190 W |
| Cooling Module Power | ~70 W |
| Brand | Derenda |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | MWS-3 |
| Price | USD 1 (FOB) |
| Measured Parameters | TSP / PM₁₀ / PM₂.₅ |
| Brand | Derenda |
|---|---|
| Origin | Jiangsu, China |
| Model | AWS-3S |
| Flow Range | 1–3.5 m³/h |
| Pump Pressure Resistance | >50 kPa at 1.0 m³/h |
| Flow Stability | 16.7 L/min (1 m³/h) |
| Max Flow Deviation | ≤2.0% over 24 h |
| Operating Duration per Cycle | 1 min to 999 h |
| Filter Capacity | 98 × 47 mm filters (7 trays × 14 positions) |
| Balance Resolution | 1 µg (10⁻⁶ g) |
| Temperature Control Range | 15–30 °C (±0.1 °C resolution) |
| Stability | ≤±0.5 °C over full weighing cycle |
| Humidity Control Range | 40–60 %RH (±0.1 %RH resolution) |
| Stability | ≤5 %RH over full cycle |
| Airflow Velocity in Chamber | ≤0.2 m/s (software-adjustable) |
| Cleanroom Class | ISO 14644 Class 6 |
| Robotic Positioning Accuracy | ±0.05 mm |
| Electrostatic Dissipation Time | ≤20 s (adjustable) |
| Vibration Isolation | Four-stage passive damping |
| Power Supply | 220 V ±10%, 50 Hz |
| Total Power Consumption | ≤3 kW |
| Weight | ≤700 kg |
Show next