Empowering Scientific Discovery

Comet Durranda (Wuxi) Measurement Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDerenda
OriginJiangsu, China
ModelAWS-1RE
Measurement MethodFilter Gravimetry
Measurable ParametersPM₂.₅, PM₁₀, TSP, Low-Concentration Sampling Heads, No. 3 Impingers
Temperature Control Range15–30 °C (±0.5 °C)
Relative Humidity Control Range40–60 %RH (±5 %RH)
Cleanroom ClassISO 14644-1 Class 6
Max Throughput225 × 47 mm filters / 105 × 90 mm filters / 45 × No. 3 impingers per batch
Weighing Time per Filter≤20 s
Electrostatic Dissipation Efficiency≥92%
Balance Readability0.001 mg (optional 0.0001 mg)
Repeatability0.003 mg
Linearity Error0.02 mg
Vibration IsolationFour-Tier Passive Damping System
Filter IdentificationRFID + QR/Barcode
Data ComplianceASTM D1357, ISO 12103-1, US EPA QA/QC Document 2.12, HJ 656–2013, EN 12341:2014, EN 14907:2005
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDerenda
OriginGermany
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelLVS
Flow Range1.0–3.5 m³/h (adjustable)
Vacuum Pressure>800 hPa
Flow Stability<2.0% deviation over 24 h
Maximum Flow Accuracy≤±2%
Operating Duration under Max Flow & Resistance1 min–999 h
Rated Service Life under Max Flow & Resistance>50,000 h
Filter Diameter47 mm
Dimensions300 × 250 × 450 mm
Weight~19.5 kg
Noise Level<62 dB(A) (per DIN 2058, at 8 m distance)
Ambient Operating Temperature−30°C to +50°C
Relative Humidity Range0–100% RH
Ingress Protection RatingIP55
Power Supply220 V ±10%, 50/60 Hz
Max Power Consumption390 W
Data Storage Capacity>1,000,000 records (5-min intervals)
Load Capacity≥50 kPa at 1.0 m³/h
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDerenda
OriginGermany
ModelMVS+AFC
Instrument Type24-Hour Constant-Temperature Constant-Flow Gas Sampler
Instrument ArchitectureMulti-Channel Gas Sampler
Flow Range1.0–4.5 m³/h (adjustable)
Vacuum Pressure Capability>800 hPa
Nominal Flow Rate2.3 m³/h
Flow Stability±2.0% deviation over 24 h
Operating Duration at Max Flow & Backpressure1 min–999 h
Service Life Under Max Flow & Backpressure>50,000 h
Filter Diameter47 mm
Power Supply220 V ±10%, 50 Hz
Power Consumption350 VA
Dimensions (MVS)300 × 250 × 450 mm
Dimensions (AFC)440 × 310 × 700 mm
Weight (MVS)22 kg
Weight (AFC)24.5 kg
Noise Level<62 dB(A) (per DIN 2058, measured at 8 m)
Operating Temperature−30 °C to +50 °C
Operating Humidity0–100 %RH
Ingress Protection RatingIP55
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDerenda
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelAPM-200
Price RangeUSD 13,500 – 40,500 (FOB Hamburg)
Pollutants MeasuredO₃, PM₂.₅, PM₁₀
Measurement PrincipleUV Absorption (O₃), Dual-Stage Laser Light Scattering (PM₂.₅/PM₁₀)
Protection RatingIP65
Operating Temperature−30 °C to +50 °C
Operating Humidity0–100 % RH (with auto-heating dehumidification)
Data Storage>100,000 records (expandable via USB/SD)
O₃ Range0–500 µg/m³ (0–250 ppb), Resolution: 0.1 µg/m³, Accuracy: ±2 µg/m³, LOD: 2.0 µg/m³
PM Range0–2500 µg/m³, Resolution: 0.1 µg/m³, Flow Rate: 3.3 L/min
Sampling Interval2 s (configurable), Data Averaging Options: 10 s, 1 min, 5 min, 1 h
ComplianceHJ 590–2010, HJ 654–2013, GB/T 18204.2–2014, EPA 40 CFR Part 50, VDI 4202 Part 1, VDI 4203 Part 3
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDerenda
OriginGermany
ModelAPM-100
Measurement PrincipleUV Absorption (Beer–Lambert Law)
Measurement Range0–500 µg/m³
Resolution0.1 µg/m³
Accuracy±2 µg/m³
Detection Limit2.0 µg/m³
Baseline Drift<3 µg/m³/day, <6 µg/m³/year
Measurement Interval2 s (0.5 Hz)
Data Averaging Options10 s, 1 min, 5 min, 1 h
Data Storage Capacity>100,000 records (expandable via USB/SD card)
Flow Rate0.6–1.5 L/min (nominal 1.0 L/min)
Operating Temperature0–50 °C
Ambient Pressure CompensationYes
Temperature CompensationYes
Protection RatingIP65
Dimensions300 × 250 × 450 mm
Weight~10 kg
ComplianceHJ 193-2013, HJ 654-2013, HJ 818-2018, HJ 965-2018
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDerenda
OriginGermany
ModelAPM-101
Measurement PrincipleUV Absorption (Beer–Lambert Law)
Measurement Range0–500 µg/m³
Resolution0.1 µg/m³
Accuracy±2 µg/m³
Detection Limit2.0 µg/m³
Baseline Drift<3 µg/m³/day, <6 µg/m³/year
Measurement Interval2 s (0.5 Hz)
Data Averaging Options10 s, 1 min, 5 min, 1 h
Data Storage Capacity>100,000 records (expandable via USB/SD card)
Flow Rate0.6–1.5 L/min (nominal 1.0 L/min)
Operating Temperature0–50 °C
Pressure UnithPa
Temperature Unit°C
Ozone Unitsµg/m³, ppb
Dimensions420 × 320 × 180 mm
Weight~7 kg
Built-in Rechargeable Li-ion Battery>24 h operation
GPS ModuleIntegrated
ComplianceHJ 590–2010, HJ 654–2013, GB/T 18204.2–2014, EPA 40 CFR Part 50, VDI 4202 Part 1, VDI 4203 Part 3
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDerenda
OriginGermany
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelMVS
Flow Range1.0–4.5 m³/h (adjustable)
Rated Flow2.3 m³/h
Maximum Static Pressure>800 hPa
Flow Stability<2.0% deviation over 24 h
Maximum Flow Error≤±2%
Operating Duration at Max Flow & Load1 min–999 h
Rated Lifetime at Max Flow & Load>50,000 h
Filter Diameter47 mm
Dimensions300 × 250 × 450 mm
Weight~17 kg
Noise Level<35 dB(A) (per DIN 2058, measured at 8 m)
Operating Temperature−30°C to +50°C
Operating Humidity0–100% RH
Ingress ProtectionIP55
Power Supply220 V ±10%, 50/60 Hz
Data Storage Capacity>1,000,000 records (5-min intervals)
ComplianceEN 12341:2014 (PM₁₀), EN 14907:2005 (PM₂.₅)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDerenda
OriginGermany
ModelPNS-90
Flow Range80–120 L/min (adjustable)
Rated Flow100 L/min (6 m³/h)
Vacuum Pressure>800 hPa
Flow Stability≤±2.0% deviation over 24 h
Operating Lifetime at Max Flow & Backpressure>50,000 h
Maximum Continuous Run Time per Cycle1 min–999 h
Filter Diameter90 mm
Dimensions590 × 415 × 1100 mm
Weight65 kg
Power Supply220 V ±10%, 50 Hz
Power Consumption470 VA (standby) / 570 VA (operational)
Max. Power600 VA
Data Storage Capacity>1,000,000 records (1-min resolution, configurable)
Operating Temperature−30 °C to +50 °C
Operating Humidity0–100 %RH
Ingress ProtectionIP55
Cooling ModulePeltier-based filter storage unit (≤20 °C)
PositioningDual-mode BeiDou/GPS
Compliant StandardsHJ 618–2011, HJ 93–2013, JJG 943–2011
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDerenda
OriginJiangsu, China
ModelMWS-2
Measurement MethodFilter Gravimetric Method
Measured ParametersTSP / PM₁₀ / PM₂.₅ / PM₁
ComplianceHJ 836–2017, HJ 656–2013, EN 12341:2014, US EPA 40 CFR Part 86/1065, EPA QA Document No. 2.12 (Ambient Air Quality)
Sample Capacity (per batch)80 × 47 mm filters (160 with optional storage tower), 30 × 90 mm filters (60 with tower), 24 × low-concentration samplers (48 with tower), 24 × No.3 impinger tubes (48 with tower)
Temperature Control Range15–30 °C (±0.1 °C stability)
Humidity Control Range40–55 %RH (±2 %RH accuracy)
Dew Point Stability±0.1 °C
Chamber CleanlinessISO 14644 Class 6
Weighing Instrument OptionsAnalytical balance with readability down to 0.01 mg (10 µg) or 0.001 mg (1 µg), integrated anti-vibration platform with decoupling architecture
Electrostatic NeutralizationIonizing air blower (radiation-free, 100% neutralization efficiency per cycle)
IdentificationQR code, barcode, and optional RFID encoding (chip embedded in sample holder ring)
User InterfaceErgonomic front access ports, large transparent viewing panel, built-in control software with audit-trail-capable database
Power220 V ±10%, 50 Hz, 1000 W
Dimensions1180 mm (L) × 800 mm (W) × 2000 mm (H)
Weight400 kg (including climate module)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDerenda
OriginGermany
ModelAWS-1 Automated Filter Weighing System
Flow Range0.2–1.2 m³/h (16.67 L/min)
Vacuum Pressure>40,000 Pa
Flow Stability≤±2% over 24 h
Maximum Flow Error≤±2%
Operating Duration at Max Flow & Resistance1 min–999 h
Rated Service Life at Max Flow & Resistance50,000 h
Balance Resolution0.001 mg
Balance Stabilization Time≤6 s
Temperature Control Range15–32 °C (±0.1 °C accuracy)
Relative Humidity Control Range35–55 %RH (±1 %RH accuracy)
Dew Point Control Accuracy±0.1 °C
Dimensions (L×W×H)1620 × 900 × 2325 mm
System Weight600 kg
Power Consumption1400 W
Ambient Operating Temperature5–40 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDerenda
ModelMDM-2
Measurement PrincipleLaser Light Scattering (Nephelometry)
Measured ParametersPM₁, PM₂.₅, PM₁₀
PM₂.₅ Range0–2500 µg/m³
PM₁₀ Range0–5000 µg/m³ (calculated from PM₂.₅)
Minimum Detection Limit2 µg/m³
Resolution0.1 µg/m³
Sampling Flow Rate≥0.15 L/min (typical 0.3 L/min)
Measurement Interval2 s
Response Time≤5 s
Accuracy (24-hr avg)±15%
Power SupplyRechargeable Li-ion Battery
Battery LifeUp to 8 h
Dimensions220 mm × 90 mm × 85 mm
Weight~600 g
Data Storage & TransmissionmicroSD card, 3G/4G module
Integrated SensorsBarometric Pressure, Altitude
DisplayColor TFT Touchscreen
Expected Photometer Lifetime5 years
ComplianceDesigned for field-deployable ambient air monitoring per ISO 12103-1 reference aerosol compatibility and aligned with EPA EQPM-0709-192 performance expectations for portable PM monitors
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDerenda
OriginGermany
ModelLVS+AFC
Flow Range1.0–3.5 m³/h (adjustable)
Vacuum Pressure>800 hPa
Flow Stability≤2.0% deviation over 24 h
Maximum Flow Error≤±2.0%
Operating Duration at Max Flow & Load1 min–999 h
Service Life at Max Flow & Load>50,000 h
Filter Diameter47 mm
Power Supply220 V ±10%, 50 Hz
Power Consumption350 VA (without Peltier cooling) / 470 VA (with cooling)
Dimensions (LVS)300 × 250 × 450 mm
Dimensions (AFC)440 × 310 × 700 mm
Weight (LVS)19.5 kg
Weight (AFC)24.5 kg
Noise Level<62 dB(A) (per DIN 2058, measured at 8 m)
Operating Temperature−30°C to +50°C
Operating Humidity0–100% RH
Ingress ProtectionIP55 (without Peltier module)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDerenda
OriginGermany
ModelPNS 16T
Flow Range1.5–3.5 m³/h (adjustable)
Vacuum Pressure800 hPa
Flow Stability≤2.0% deviation over 24 h
Maximum Flow Error≤±2.0%
Operating Duration at Max Flow & Load1 min to 999 h
Rated Lifetime at Max Flow & Load50,000 h
Filter Diameter47 mm
Dimensions460 × 270 × 1100 mm
Weight44.5 kg
Power Supply220 V ±10%, 50 Hz
Max Power Consumption420 W
Noise Level<62 dB(A) (per DIN 2058, at 8 m)
Operating Temperature−30°C to +50°C
Operating Humidity0–100% RH
Ingress ProtectionIP55
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDerenda
OriginGermany
ModelAPM-2E
Measurement PrincipleLaser Light Scattering
Measured ParametersPM₁₀ / PM₂.₅
Measurement Range0–2500 µg/m³
Minimum Detection Limit1 µg/m³
Measurement Interval5 s
Flow Stability±5%
Resolution0.1 µg/m³
Operating Temperature−30 °C to +50 °C
Operating Humidity0–100 %RH (with automatic heating dehumidification)
Acoustic Noise<35 dB(A) (per DIN 2058, at 8 m)
Power SupplyAC 220 V ±10 %, 50/60 Hz
Enclosure RatingIP65
Dimensions300 × 250 × 480 mm
Weight15 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDerenda
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPNS16T-10
Typical ConfigurationIntegrated Ambient Air Particulate Sampler
Flow Range1.0–2.3 m³/h (adjustable)
Maximum Vacuum Pressure>800 hPa
Flow Stability<2.0% deviation over 24 h
Maximum Flow Accuracy≤±2%
Operating Duration at Max Flow & Backpressure1 min–999 h
Rated Lifetime at Max Flow & Backpressure>50,000 h
Temperature Control Range (Filter Chamber)≤20 °C (adjustable, via Peltier cooling)
Ambient Operating Temperature−30 °C to +50 °C
Relative Humidity Range0–100% RH
Sampling Time Range1 min–999 h
Power Supply220 V ±10%, 50 Hz
Filter Diameter47 mm
Dimensions330 × 330 × 430 mm
Weight20 kg
Acoustic Noise Level<62 dB(A)
Ingress Protection RatingIP55
Max Power Consumption190 W
Cooling Module Power~70 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDerenda
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic
ModelMWS-3
PriceUSD 1 (FOB)
Measured ParametersTSP / PM₁₀ / PM₂.₅
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDerenda
OriginJiangsu, China
ModelAWS-3S
Flow Range1–3.5 m³/h
Pump Pressure Resistance>50 kPa at 1.0 m³/h
Flow Stability16.7 L/min (1 m³/h)
Max Flow Deviation≤2.0% over 24 h
Operating Duration per Cycle1 min to 999 h
Filter Capacity98 × 47 mm filters (7 trays × 14 positions)
Balance Resolution1 µg (10⁻⁶ g)
Temperature Control Range15–30 °C (±0.1 °C resolution)
Stability≤±0.5 °C over full weighing cycle
Humidity Control Range40–60 %RH (±0.1 %RH resolution)
Stability≤5 %RH over full cycle
Airflow Velocity in Chamber≤0.2 m/s (software-adjustable)
Cleanroom ClassISO 14644 Class 6
Robotic Positioning Accuracy±0.05 mm
Electrostatic Dissipation Time≤20 s (adjustable)
Vibration IsolationFour-stage passive damping
Power Supply220 V ±10%, 50 Hz
Total Power Consumption≤3 kW
Weight≤700 kg
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0