Common Laboratory Equipment
Filter
Showing 3181–3210 of 5014 results
| Brand | Junjin |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | J²-D100T-CERAMICS |
| Build Volume | 96 × 54 × 150 mm |
| Compatible Materials | Photopolymer Resins, Alumina (Al₂O₃), Zirconia (ZrO₂), Silica (SiO₂), Barium Titanate (BaTiO₃), Lead Zirconate Titanate (PZT), Hydroxyapatite (HA), Metal Oxides, Silicon Nitride (Si₃N₄), Silicon Carbide (SiC), Bioactive Glasses |
| Brand | Junjin |
|---|---|
| Origin | Guangdong, China |
| Model | J2-W300TIII |
| Max Build Area | 100 mm × 100 mm |
| Z-Axis Load Capacity | 2 kg |
| Y-Stage Load Capacity | 10 kg |
| XYZ Travel Range | 300 mm × 300 mm × 100 mm |
| Repeatability | ±0.004 mm per axis (X/Y/Z) |
| Max Speed | 500 mm/s |
| Max Acceleration | 0.8 G |
| Drive System | Servo Motors + High-Precision Linear Modules |
| Vision System | 5 MP @ 14 fps |
| Light Source | Single-Channel Red LED Ring Light |
| Input Air Pressure | 0.4–0.7 MPa |
| Total Power Consumption | 1.2 kW |
| Motion Control | 3-Axis Synchronized Interpolation Supporting Linear, Circular, Helical, Elliptical, Involute, Conical, and B-Spline Trajectories |
| Optional Add-ons | UV Curing Lamp, Machine Vision Inspection, Laser Height Probing, Vacuum Bed |
| Brand | JWINS |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DC-3005A |
| Instrument Type | Circulating Constant-Temperature Bath |
| Circulation Mode | Internal & External |
| Temperature Control | Refrigeration & Heating |
| Bath Volume | 5 L |
| Temperature Range | −30 °C to +100 °C |
| Temperature Stability | ±0.05 °C |
| Display Resolution | 0.01 °C |
| Internal Dimensions (L×W×H) | 250 × 200 × 120 mm |
| Depth | 120 mm |
| Pump Flow Rate | 8–12 L/min |
| Opening Size | 180 × 140 mm |
| Construction | Stainless Steel Interior, Cold-Rolled Steel Powder-Coated Exterior |
| Refrigeration System | Hermetically Sealed Compressor |
| Safety Features | Over-Temperature Protection with Audible Alarm & Automatic Load Cut-off |
| Communication Interface | Optional RS232/RS485 |
| Compliance | JJF 1030–1998 (PRC National Metrological Verification Regulation for Constant-Temperature Baths) |
| Brand | JWINS |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DHG-9079A |
| Instrument Type | High-Temperature Drying Oven |
| Temperature Range | RT+30°C to 500°C |
| Temperature Uniformity | ±2°C |
| Interior Dimensions (W×D×H) | 400×400×450 mm |
| Interior Material | Mirror-Finish Stainless Steel |
| Heating Method | Forced-Air Circulation with Centrifugal Blower |
| Brand | JWINS |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SX2-2.5-10N |
| Instrument Type | Box-Type Resistance Furnace |
| Maximum Temperature | 1000 °C |
| Temperature Control Accuracy | ±1 °C |
| Rated Power | 2.5 kW |
| Heating Time to Max Temp | ≤30 min |
| Heating Element | Nickel-Chromium (NiCr) Wire |
| Internal Chamber Dimensions | 120 × 200 × 80 mm |
| Nominal Chamber Volume | 2 L |
| Operating Temperature Range | RT + 50 °C to 1000 °C |
| Supply Voltage | AC 220 V / 50 Hz |
| Chamber Lining Material | Refractory Firebrick |
| Brand | Shanghai Jingxin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JX-ZLJ |
| Pricing | Upon Request |
| Max Design Pressure | 2000 psi |
| Max Operating Pressure | 1000 psi |
| Final Particle Size Range | 50–1000 nm |
| Maximum Chamber Volume | 10 mL |
| Membrane Diameter | 25 mm |
| Operating Temperature Range | 5–80 °C |
| Temperature Control | Jacketed Thermal Management (Heating/Cooling) |
| Construction Material | SUS 316L Stainless Steel |
| Sterilization Compatibility | Steam & Autoclave (<145 °C) |
| Cleaning Temperature Limit | <90 °C |
| Membrane Change | Tool-Free |
| Residual Sample Volume | <0.3 mL |
| Brand | Shanghai Jingxin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Bead Mill Homogenizer |
| Processing Capacity Range | 5 mL – 4 L (selectable) |
| Speed Range | 3000–36,000 rpm |
| Processing Time | 1–9999 s |
| Noise Level | <60 dB(A) |
| Display | 10-inch Full-Color Touchscreen Interface |
| Automation Level | Fully Automated |
| Sample Positions | 1–3 |
| Cleaning System | Dual Independent Ultrasonic Wash Stations (Deionized Water + Organic Solvent) |
| Blade Material | ASTM F138-Grade 316L Stainless Steel |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Safety Features | Sealed chamber with active exhaust ventilation, drip-proof sample tray, cup presence detection, front-access transparent door with integrated LED illumination |
| Brand | ZXYIQI |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | K-PSA-150ML |
| Price | ¥46,000 |
| Usable Volume | 150 mL (Small-scale) |
| Construction Material | Stainless Steel (304/316L standard) |
| Operating Pressure Range | Low-to-Medium Pressure (up to 30 MPa, per series specification) |
| Vacuum Capability | ≤ –0.1 MPa (gauge) |
| Heating Power | 0–2500 W |
| Temperature Range | 0–600 °C |
| Stirring Speed | 0–400 rpm |
| Motor | Brushless DC, 100 W |
| Sealing Options | Soft (PTFE/Gasket) or Hard (Metal-to-Metal) |
| Safety Features | Overpressure rupture disc (Hastelloy), overtemperature/over-time alarm, automatic pressure relief |
| Control System | Dual-loop PID temperature control, programmable ramp-soak profiles (optional), real-time data logging |
| Brand | KaiGe |
|---|---|
| Origin | Germany |
| Model | MAK / MOK |
| Type | Manual/Electric Linear Notching Machine for Charpy/Izod Impact Test Specimens |
| Compliance | ASTM E23, ISO 148-1, ISO 180, DIN 53438, EN ISO 179-1 |
| Max Specimen Height | 30 mm |
| Tool Positioning Tolerance | < 0.01 mm |
| Feed Resolution | 0.001 mm (selectable) |
| MAK Cutting Speed | ~0.3 m/s |
| MOK Cutting Speed | up to 20 m/min |
| Power Supply | 230 V / 50 Hz |
| MOK Power Consumption | 0.4 kVA |
| Dimensions (W×H×D, mm) | MAK: 470 × 215 × 220 |
| MOK | 470 × 540 × 470 |
| Weight | MAK: 16 kg |
| MOK | 43 kg |
| Max Simultaneous Specimens | 7 |
| Safety | Integrated Polycarbonate Shield with Interlocked Safety Switch (MOK only) |
| Tool System | Interchangeable Carbide-Tipped Notching Cutters (V-notch: 45° ± 0.5°, root radius 0.25 mm ± 0.025 mm |
| U-notch | 1 mm ± 0.05 mm radius) |
| Brand | Kamoer |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | KMC57 |
| Instrument Type | Peristaltic Pump |
| Flow Rate Range | 0.01–29 mL/min per channel |
| Motor Type | 57-step Hybrid Stepper Motor |
| Channel Configuration | Configurable for 3- or 4-channel pump heads |
| Rotor Design | 12-roller low-pulsation rotor |
| Mounting | Front-panel flush-mount compatible |
| Tubing Compatibility | PVC, PU, and other chemically resistant elastomeric tubing (including microbore capillary tubing) |
| Application Domain | ICP-OES/ICP-MS sample introduction, analytical instrument fluid handling, microfluidic dispensing, clinical analyzer reagent delivery |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | KAN-7600 |
| Quotation | Upon Request |
| Airflow Range | 100–500 m³/h |
| Max. Cabin Static Pressure | ±2500 Pa (adjustable) |
| Standard Nozzle Diameters | Φ41 mm & Φ39 mm |
| Pressure Measurement Port | Integrated static pressure tap on flange |
| Control Method | Inverter-driven variable-speed blower with real-time feedback loop |
| Compliance | JIS D 1622 (Automotive Ventilation Performance Test), JIS B 8330 (Blower Testing and Inspection) |
| Brand | KARG |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AKM |
| Quotation | Upon Request |
| Blade Travel Speed | 0–800 mm/s |
| Stroke Length | 208 mm |
| Notch Type | V-Notch |
| Feed Rate (Notching) | 0.01–0.3 mm/rev |
| (Fine Adjustment) | 0.01–0.1 mm/rev |
| Saw Cutting Speed | 0.3–1 m/min |
| Saw Rotational Speed | 1000–2000 rpm |
| Notch Depth (Z-axis) | 0.01–0.25 mm |
| Machining Length | ~200 mm |
| Width | 1200 mm |
| Height | 700 mm |
| Depth | 540 mm |
| Weight | 150 kg |
| Power Consumption | ~1 kW |
| Supply Voltage/Frequency | 230 V / 110 V, 50/60 Hz |
| Brand | Karg |
|---|---|
| Origin | Germany |
| Model | MPS 75 / MPS 150 |
| Max Punching Force | 7,500 N (MPS 75) / 15,000 N (MPS 150) |
| Max Stroke | 40 mm |
| Table Dimensions | 250 × 150 mm |
| Weight | 50 kg |
| Footprint (W×D) | 250 × 240 mm (MPS 75) / 250 × 300 mm (MPS 150) |
| Operation | Lever-Actuated or Pneumatic Option Available |
| Compliance | Configurable for ISO 179, ISO 180, ASTM D6110, ASTM D5041, ISO 13802 Notch Geometries |
| Brand | Katanax |
|---|---|
| Origin | Canada |
| Model | X300 |
| Dimensions (L×W×D) | 51×48×63 cm |
| Temperature Control Accuracy | ±1°C |
| Operating Temperature Range | 50–1200°C |
| Sample Throughput | 7–20 samples/hour |
| Brand | Katanax |
|---|---|
| Origin | Canada |
| Model | X600 |
| Dimensions (L×W×D) | 56 × 105 × 69 cm |
| Temperature Control Accuracy | ±1°C |
| Operating Temperature Range | 20–1200°C |
| Sample Capacity | 6 samples per run |
| Brand | KB |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KYXQ-5000 |
| Instrument Type | Hot Mounting Press |
| Heating Power | 4 kW |
| Temperature Range | 0–200 °C (factory preset: 160 °C) |
| Pressure Holding Time | 0–99 min (factory preset: 1 min) |
| Cooling Duration | 0–99 min (factory preset: 0.5 min) |
| Power Supply | 220 V, 50 Hz |
| Total Power Consumption | 2.2 kW |
| Dimensions (W×D×H) | 760 × 580 × 550 mm |
| Weight | 95 kg |
| Standard Mold Diameter | φ30 mm (optional: φ22 mm, φ45 mm |
| Sample Capacity | 4 specimens per cycle (2 stations × 2 molds) |
| Process Memory | >100 user-defined mounting protocols |
| Brand | KD Scientific |
|---|---|
| Origin | USA |
| Model | Legato |
| Instrument Type | Microfluidic Syringe Pump |
| Flow Rate | 0.5 pL/min |
| Accuracy | ±0.35% |
| Repeatability | 0.5 pL/min |
| Brand | Kedao |
|---|---|
| Origin | Shanghai, China |
| Model | SK1200H |
| Capacity | 2 L |
| Ultrasonic Frequency | 50 kHz |
| Ultrasonic Power | 50 W |
| Power Adjustment | Fixed |
| Temperature Control | Not Available |
| Timer Range | Digital, 1–99 min |
| Drain/Inlet | Manual fill and drain only |
| Type | General-purpose benchtop ultrasonic cleaner |
| Brand | Kedao |
|---|---|
| Origin | Shanghai, China |
| Model | SK2200H |
| Capacity | 3 L |
| Ultrasonic Frequency | 53 kHz |
| Ultrasonic Power | 100 W |
| Adjustable Power | No |
| Adjustable Temperature | No |
| Timer Range | 1–99 min |
| Lid Type | None (Open-top) |
| Drain/Inlet | Manual Control |
| Tank Material | 304 Stainless Steel |
| Dimensions (L×W×H) | 240 × 140 × 100 mm (tank) |
| Net Weight | 3.7 kg |
| Gross Weight | 4.5 kg |
| Standard Accessory | Stainless Steel Rack |
| Brand | Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PTL-HT-B |
| Instrument Type | Vertical Dual-Zone Tube Furnace |
| Max Temperature | 1200°C |
| Continuous Operating Temperature | 1100°C |
| Temperature Control Accuracy | ±1°C |
| Max Power | 1.5 kW |
| Heating Rate to Max Temp | 10°C/min |
| Heating Method | PID-Controlled Digital Temperature Controller |
| Internal Chamber Dimensions | 50 mm O.D. × 44 mm I.D. × 450 mm L |
| Dual Heating Zones | 2 × 100 mm length, total 200 mm heated length |
| Max Achievable Axial Temperature Gradient | 1°C/cm |
| Lift Mechanism | Touchscreen-Controlled DC Motor with Programmable Speed (1–500 µm/sec, ±0.05% accuracy), 450 mm total travel |
| Standard Suspension Wires | 3 × Ni-SS (up to 800°C) |
| Quartz Tube | 50 mm O.D. × 44 mm I.D. × 450 mm L |
| Enclosure | CE-certified |
| Warranty | 1 year parts & labor (excludes quartz tubes, seals, heating elements, and suspension wires) |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CFRD |
| Price Range | USD 1,400 – 14,000 (FOB) |
| Maximum Operating Pressure | 10 MPa (100 bar) |
| Maximum Operating Temperature | 800 °C |
| Catalyst Bed Volume | 0.5–5 mL |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FLB-4 |
| Price Range | USD 2,800 – 7,000 (FOB) |
| Chamber Capacity | Small-scale (≤50 mL typical use) |
| Operating Pressure | Low-pressure ambient environment |
| Vacuum Capability | Not applicable |
| Structural Material | Anodized aluminum housing with borosilicate glass viewport |
| Cooling System | Dual axial fans (rear-mounted, thermostatically regulated) |
| LED Mounting | Four fixed-position Kessil A365/A400-series compatible sockets (M4 threaded, 12 V DC input) |
| Power Input | 100–240 V AC, 50/60 Hz |
| IP Rating | IP20 (indoor laboratory use only) |
| Brand | KEWLAB |
|---|---|
| Model | CPS-L350 |
| Pump Type | Peristaltic Pump |
| Flow Rate Range | 0.007–1330 mL/min |
| Speed Range | 0.1–350 rpm (0.01 rpm resolution) |
| Display | 3.2-inch industrial-grade true-color LCD |
| Pressure Output | 0.1 MPa (for tubing wall thickness 0.86–1.0 mm) / 0.1–0.27 MPa (for tubing wall thickness 1.6–2.4 mm) |
| External Control Input | 0–5 V (standard), optional 0–10 V or 4–20 mA |
| Communication Interface | RS232 / RS485 |
| Power Supply | AC 220 V ±10% or AC 110 V ±10%, 50/60 Hz |
| Dimensions (L×W×H) | 261.4 × 157.3 × 236.9 mm |
| Power Consumption | <50 W |
| Operating Environment | 0–40 °C, <80% RH |
| Ingress Protection Rating | IP31 |
| Timer Range | 0.1 s – 9999 h |
| Memory Function | Power-loss retention of operating parameters |
| Brand | KEWLAB |
|---|---|
| Model | CPS-T150 |
| Pump Type | Peristaltic Pump |
| Flow Rate Range | 0.007–570 mL/min |
| Speed Range | 0.1–150 rpm (0.01 rpm resolution) |
| Display | 4.3-inch industrial-grade TFT color LCD |
| Pressure Rating | 0.1 MPa (for tubing wall thickness 0.86–1.0 mm) / 0.1–0.27 MPa (for tubing wall thickness 1.6–2.4 mm) |
| External Control Input | 0–5 V (standard), optional 0–10 V or 4–20 mA |
| Communication Interface | RS232 / RS485 |
| Power Supply | AC 220 V ±10% / 50–60 Hz or AC 110 V ±10% / 50–60 Hz |
| Dimensions (L×W×H) | 261.4 × 157.3 × 236.9 mm |
| Power Consumption | <50 W |
| Operating Environment | 0–40 °C, <80% RH |
| Ingress Protection | IP31 |
| Enclosure Material | UV-resistant ABS engineering plastic |
| PCB Protection | Triple-conformal coating (dust-, moisture-, static-, and corrosion-resistant) |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | Aseeker-100 |
| Instrument Category | Solid-Liquid Extraction System |
| Temperature Range | Ambient to 200 °C (±1 °C) |
| Pressure Range | 0–20 MPa (±0.3 MPa) |
| Extraction Cell Volumes | 11 mL / 22 mL / 33 mL |
| Collection Vial Capacities | 40 mL / 60 mL |
| Solvent Flow Rate | 0.1–50 mL/min |
| Extraction Time | 20–30 min |
| Solvent Consumption | 10 mL per 10 g sample |
| Gas Supply Requirement | Nitrogen, 0.4–1 MPa |
| Power Input | 100–240 VAC ±10 %, 50–60 Hz |
| Max. Power Consumption | 600 W |
| Dimensions (W×D×H) | 450 mm × 500 mm × 530 mm |
| Weight | 30 kg |
| Sample Contact Materials | PEEK, PTFE, 316L stainless steel, ceramic |
| Safety Features | Mechanical overpressure protection, electronic overtemperature cutoff, leak detection with automatic shutdown, liquid-level sensing with overflow prevention, integrated post-extraction filtration |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | Aseeker-200 |
| Instrument Category | Solid-Liquid Extraction |
| Temperature Range | Ambient to 200 °C (±1 °C) |
| Pressure Range | 0–20 MPa (±0.3 MPa) |
| Extraction Cell Volumes | 10 mL / 34 mL / 66 mL / 100 mL |
| Extraction Time | 20–30 min |
| Solvent Consumption | 10 mL per 10 g sample |
| Pump Flow Rate | 0.1–50 mL/min |
| Collection Vial Capacities | 60 mL / 250 mL |
| Gas Supply Requirement | Nitrogen at 0.9–1.2 MPa |
| Power Input | 100–240 VAC ±10 %, 50–60 Hz |
| Max Power Consumption | 1.2 kW |
| Dimensions (W×D×H) | 508 mm × 485 mm × 745 mm |
| Weight | 40 kg |
| Wetted Materials | PEEK, PTFE, 316L stainless steel, ceramic |
| Safety Features | Mechanical overpressure protection, electronic overtemperature cutoff, leak detection, liquid-level sensing, pressure-deficiency alarm, automatic filtration post-extraction, dual-needle purge system to prevent splashing |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | Aseeker-500 |
| Instrument Type | Solid-Liquid Extraction System |
| Temperature Range | Ambient to 200 °C (±0.5 °C) |
| Pressure Range | 10 MPa (±0.5 MPa) |
| Extraction Cell Volume | Standard 34 mL (optional: 1, 5, 10, 22, 66, 100 mL) |
| Extraction Time per Sample | 20 min |
| Instrument Dimensions | 800 mm × 738 mm × 685 mm |
| Sample Capacity | 24 extraction cells |
| Collection Vials | Standard 19 × 250 mL or up to 28 × 60 mL + 5 × 250 mL with adapter |
| Pump Flow Rate | 0.1–50 mL/min |
| Power Consumption | ≤1.2 kW |
| Input Voltage | 100–240 VAC ±10 %, 50–60 Hz |
| Solvent Mixing Capability | Up to 4 solvents |
| Cleaning Stations | 2 |
| Weight | 70 kg |
| Contact Materials | PEEK, PTFE, 316L stainless steel, ceramic |
| Safety Features | Electronic over-pressure/over-temperature protection, leak detection with automatic shutdown and sequence bypass, external air supply pressure monitoring, infrared liquid-level sensing at collection vials |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CoolMax-2000 |
| Price | ¥200,000 |
| Nebulization Method | FocusJet concentric flow design |
| Mobile Phase Flow Rate | 0.2–2 mL/min |
| Construction Materials | 316 stainless steel, PEEK, fused silica, PTFE |
| Digital Data Acquisition Rate (max) | 100 Hz |
| Digital Noise Filtering | 4th-order low-pass Bessel filter |
| Analog Output Option | 0–1 V DC |
| Evaporation Temperature Settings | 35 °C or 50 °C |
| Preheat Time to 35 °C | <15 min |
| Gas Inlet Pressure | 70–80 psi (0.4–0.5 MPa) |
| Gas Consumption | 4 L/min |
| Gas Pressure Control | Manual |
| Control Interface | PC + integrated touchscreen |
| AD Converter Resolution | 24-bit |
| Detection Limit | pg-level |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GelMaster-4000 |
| Flow Rate | 0–50 mL/min |
| Auto-sampler Volume | 5 mL standard loop (customizable), 66-position 20 mL vial tray |
| Fraction Collector Capacity | 96-position 60 mL vial tray (customizable) |
| UV Detection Wavelength Range | 190–800 nm |
| GPC Column | 20 × 300 mm, Bio-Beads S-X3 (200–400 mesh), eluent: ethyl acetate/cyclohexane (3:7, v/v) |
| Compliance | AOAC 984.21, EPA SW-846 Method 3640A, FDA 2905A, EN 12393, EN 1528, S-19, S35L00.00-34 |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GOODSPE-1200 |
| Automation Level | Fully Automatic |
| Channel Count | 1 |
| Extraction Mode | Cartridge-Based SPE |
| Flow Rate Control | 0–30 mL/min |
| Solvent Selection | 5 Independent Solvent Channels |
| Sample Capacity | Up to 288 Samples per Unattended Run |
| Sample Loading Volume | 20 mL – 20 L |
| Wetted Materials | PTFE, Borosilicate Glass |
| Valve Type | Non-Metallic 12-Port Rotary Valve |
| Pressure Output | 0–30 psi (0–1.4 bar) |
| Air Injection | Integrated 10 mL Air Syringe |
| Liquid Injection | Integrated 10 mL Liquid Syringe |
| Positioning Accuracy | 0.1 mm |
| Dispensing Accuracy | ≥99% |
| Data Interface | USB |
| Operating Voltage | 100–240 V AC, 50/60 Hz |
| Compliance | EPA Method-Compliant for Aqueous Matrix Analysis (e.g., EPA 508, 525.3, 8270) |
